Search NASA⌕ Search

SEARCH · Search NASA

Results for “Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

AVIRIS as a tool for carbonatite exploration: Comparison of SPAM and Mbandmap data analysis methods

Data acquired with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) of the Mountain Pass, San Bernadino County, California, area were analyzed to evaluate the use of narrow-band imaging data for carbonatite exploration. Carbonatites are igneous carbonate-rich rocks that are economically important in part because they are the major source for rare-earth minerals. Because the 224 AVIRIS spectral channels have a nominal spectral resolution of 10 nm, narrow absorption features such as those displayed by the rare-earth elements neodymium (Nd) and samarium (Sm) may be detected. The Mountain Pass region encompasses a well-exposed sequence of sedimentary, metamorphic, and igneous rocks, including an alkalic carbonatite intrusion. The carbonatite was emplaced in Precambrian granitic rocks that are fault bounded by a thick suite of Paleozoic, sedimentary rock, predominantly dolomite. The carbonatite stock, the major source of light rare-earth elements (REE) in the United States, affords the opportunity to test AVIRIS capabilities for detecting REE absorption features. Nd-bearing minerals display narrow, sharp and distinctive spectral features at 580, 740, 800, and 870 nm. Minerals bearing Sm display similarly sharp features near 1090, 1250, 1410, and 1550 nm. The more common REE, lanthanum and cerium, do not display absorption features in the visible/near-infrared region in their natural oxidation states.

Kingston, Marguerite J.↗

AVIRIS Reflectance Retrievals: UCSB Users Manual

The following write-up is designed to help students and researchers take Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) radiance data and retrieve surface reflectance. In the event that the software is not available, but a user has access to a reflectance product, this document is designed to provide a better understanding of how AVIRIS reflectance was retrieved. This guide assumes that the reader has both a basic understanding of the UNIX computing environment, and that of spectroscopy. Knowledge of the Interactive Data Language (IDL) and the Environment for Visualizing Images (ENVI) is helpful. This is a working document, and many of the fine details described in the following pages have been previously undocumented. After having read this document the reader should be able to process AVIRIS to reflectance, provided access to all of the code is possible. The AVIRIS radiance data itself is pre-processed at the Jet Propulsion Laboratory (JPL) in Pasadena, California. The first section of this paper describes how to read data from tape and byte-swap the data. Section 2 describes the procedure in preparing support files before running the 'h2o' suite of programs. Section 3 describes the four programs used in the process, h2olut9.f, h2ospl9.f, vlsfit9.f and rfl9.f.

Roberts, Dar A.↗

Summaries of the Fifth Annual JPL Airborne Earth Science Workshop. Volume 2: TIMS Workshop

This publication is the second volume of the summaries for the Fifth Annual JPL Airborne Earth Science Workshop, held in Pasadena, California, on January 23-26, 1995. The main workshop is divided into three smaller workshops as follows: (1) The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) workshop on January 23-24. The summaries for this workshop appear in Volume 1; (2) The Airborne Synthetic Aperture Radar (AIRSAR) workshop on January 25-26. The summaries for this workshop appear in volume 3; and (3) The Thermal Infrared Multispectral Scanner (TIMS) workshop on January 26. The summaries for this workshop appear in this volume.

Realmuto, Vincent J.↗

Summaries of the Fifth Annual JPL Airborne Earth Science Workshop. Volume 3: AIRSAR Workshop

This publication is the third containing summaries for the Fifth Annual JPL Airborne Earth Science Workshop, held in Pasadena, California, on January 23-26, 1995. The main workshop is divided into three smaller workshops as follows: (1) The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) workshop, on January 23-24. The summaries for this workshop appear in Volume 1; (2) The Airborne synthetic Aperture Radar (AIRSAR) workshop, on January 25-26. The summaries for this workshop appear in this volume; and (3) The Thermal Infrared Multispectral Scanner (TIMS) workshop, on January 26. The summaries for this workshop appear in Volume 2.

Vanzyl, Jakob↗

Summaries of the 4th Annual JPL Airborne Geoscience Workshop. Volume 1: AVIRIS Workshop

This publication contains the summaries for the Fourth Annual JPL Airborne Geoscience Workshop, held in Washington, D. C. October 25-29, 1993 The main workshop is divided into three smaller workshops as follows: The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) workshop, October 25-26 (the summaries for this workshop appear in this volume, Volume 1); The Thermal Infrared Multispectral Scanner (TMIS) workshop, on October 27 (the summaries for this workshop appear in Volume 2); and The Airborne Synthetic Aperture Radar (AIRSAR) workshop, October 28-29 (the summaries for this workshop appear in Volume 3).

Green, Robert O.↗

Derivation of scaled surface reflectances from AVIRIS data

A method for retrieving 'scaled surface reflectances' assuming horizontal surfaces having Lambertian reflectances from spectral data collected by Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is presented here. In this method, the integrated water vapor amount on a pixel by pixel basis is derived from the 0.94 micron and 1.14 micron water vapor absorption features. The transmission spectra of H2O, CO2, O3, N2O, CO, CH4, and O2 in the 0.4-2.5 micron region are simulated. The scattering effect due to atmospheric molecules and aerosols is modeled with the 5S computer code. The AVIRIS radiances are divided by solar irradiances above the atmosphere to obtain the apparent reflectances. The scaled surface reflectances are derived from the apparent reflectances using the simulated atmospheric gaseous transmittances and the simulated molecular and aerosol scattering data. The scaled surface reflectances differ from the real surface reflectances by a multiplicative factor. In order to convert the scaled surface reflectances into real surface reflectances, the slopes and aspects of the surfaces must be known.

Gao, Bo-Cai↗

Software for the derivation of scaled surface reflectances from AVIRIS data

An operational software program is now available for deriving 'scaled surface reflectances' from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The program simulates both the atmospheric scattering and absorption effects. Brief descriptions of the algorithm, inputs, outputs, the limitations of the software, and procedures for obtaining the software are given.

Gao, Bo-Cai↗

Estimation of Biomass Fire Temperature and Areal Extent from Calibrated AVIRIS Spectra

This paper describes an approach to derive a range of biomass fire parameters from spectra measured by NASA's Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS measures images of the upwelling spectral radiance from 400 to 2500 nm at 10nm intervals. Images are measured of 11 by up to 100 km with 20 by 20 m spatial resolution.

Biomass AVRIS biomass fire smoke cloud aerosol and↗

Lossless compression of AVIRIS data: Comparison of methods and instrument constraints

A family of lossless compression methods, allowing exact image reconstruction, are evaluated for compressing Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) image data. The methods are used on Differential Pulse Code Modulation (DPCM). The compressed data have an entropy of order 6 bits/pixel. A theoretical model indicates that significantly better lossless compression is unlikely to be achieved because of limits caused by the noise in the AVIRIS channels. AVIRIS data differ from data produced by other visible/near-infrared sensors, such as LANDSAT-TM or SPOT, in several ways. Firstly, the data are recorded at a greater resolution (12 bits, though packed into 16-bit words). Secondly, the spectral channels are relatively narrow and provide continuous coverage of the spectrum so that the data in adjacent channels are generally highly correlated. Thirdly, the noise characteristics of the AVIRIS are defined by the channels' Noise Equivalent Radiances (NER's), and these NER's show that, at some wavelengths, the least significant 5 or 6 bits of data are essentially noise.

Roger, R. E.↗

AVIRIS ground data processing system

During the last year and a half, Feb. 1991 to Jun. 1992, a major upgrade of the Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) ground data processing system took place. Both the hardware and software components were changed significantly to improve the processing capacity and performance and to structure a data facility capable of handling the projected work load into the near future. A summary report of these changes and some projections for the future are provided. The objectives of the AVIRIS data facility are to decommutate and archive AVIRIS data and to provide raw or radiometrically calibrated data products to the science investigator. These primary objectives have not changed from the initial concepts. The upgrade effort has greatly improved the processing system. These objectives can now be accomplished in a more timely fashion at a reasonable cost and there is sufficient capacity to manage the current processing load and provide for future growth. The method of implementation added the flexibility to provide better service to the investigator and allow for future changes.

Hansen, Earl G.↗

Estimating The SNR Of AVIRIS Data

Combination of established statistical and filtering techniques yields improved estimates of signal-to-noise ratio (SNR) of multispectral imagery produced by Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). Method yields more accurate estimate of random variability in AVIRIS imagery. Combination of techniques called "geostatistical" method. In first step of method, periodic noise removed by notch filtering in frequency domain. In subsequent steps, sensor noise and variability within picture elements isolated by use of semi-variance of picture elements.

Curran, Paul J.↗

In-flight calibration of the spectral and radiometric characteristics of AVIRIS in 1991

On 7 Mar. 1991, an in-flight calibration experiment was held at the Ivanpah Playa in southeastern California for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imaging spectrometer. Five AVIRIS overflights were acquired of a calibration target designated on the Ivanpah Playa surface. At the time of the overflights, the reflectance of the calibration target was measured with a field spectrometer. In addition, the atmospheric optical depths and water vapor abundance were measured from a radiometer station adjacent to the calibration target. These in-situ measurements were used to constrain the MODTRAN radiative transfer code to model the upwelling spectral radiance incident to the sensor aperture during the overflights. Analyses of this modeled radiance in conjunction with the laboratory-calibrated radiance were used to determine the spectral and radiometric calibration of AVIRIS while in flight.

Green, Robert O.↗

Proceedings of the Tenth JPL Airborne Earth Science Workshop

This publication contains the proceedings of the AVIRIS Earth Science and Applications Workshop - a forum held to report science research and applications results with spectral images measured by the NASA Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). These papers were presented at the Jet Propulsion Laboratory on February 27 and 28 and March 1 and 2, 2001.

Green, Robert O.↗

Mineral Mapping Using AVIRIS Data at Ray Mine, AZ

Imaging Spectroscopy enables the identification and mapping of surface mineralogy over large areas. This study focused on assessing the utility of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data for environmental impact analysis over the Environmental Protection Agency's (EPA) high priority Superfund site Ray Mine, AZ. Using the Spectral Angle Mapper (SAM) algorithm to analyze AVIRIS data makes it possible to map surface materials that are indicative of acid generating minerals. The improved performance of the AVIRIS sensor since 1996 provides data with sufficient signal to noise ratio to characterize up to 8 image endmembers. Specifically we employed SAM to map minerals associated with mine generated acid waste, namely jarositc, goethite, and hematite, in the presence of a complex mineralogical background.

McCubbin, Ian↗

The Hyperspectral Imager Aboard the SSTI's Lewis Spacecraft: A Comparison with AVIRIS

This paper compares the performance and operational parameters of the Hyperspectral Imager (HSI), scheduled for launch aboard the Lewis spacecraft in July 1996, with those of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The HSI is a pushbroom, imaging spectrometer with 30 meter spatial resolution, generating 384 spectral channels over the range 400 to 2500 nm at 5.0 to 6.4 nm resolution for each of its 256 crosstrack pixels.

Sokolowski, James K.↗

AVIRIS Measurements of Spectral Reflectance Characteristics of Whitecaps

The spectral reflectance of oceanic whitecaps in the visible and near infrared was investigated using high-altitude, 20 m resolution Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measurements off the Southern California coast. The whitecap effect on surface reflectance was expressed as a function of the difference between the reflectance of pixels contaminated by whitecaps and of adjacent pixels free of whitecaps. Whitecap reflectance was found to decrease substantially in the near infrared, by about 40% at 850 nm and 80% at 1,600 nm, in agreement with previous measurements in the coastal zone and the open ocean. The spectral dependence of whitecap reflectance appears to be fairly independent of environmental conditions, making it easy to take into account the resulting and significant effects in ocean color and aerosol remote sensing algorithms.

Frouin, Robert↗