At least 145 records · Page 8

A Solar-assisted Voltage Optimization Method for Transmission Solar Network Power System

This paper proposes a new formulation and solution algorithm that uses transmission level solar inverters to address the security-constrained optimal power flow (SCOPF) problem. The goal is to stabilize voltage fluctuations in transmission networks in base case and contingency scenarios, by using bulk solar power plant with a minimal number of post-contingency corrections. To achieve this goal, a two-stage volt/var optimization method is proposed to first correct all voltage violations with the volt-var alternating current optimal power flow (ACOPF) algorithm for a base case. Then a linearized SCOPF volt-var control algorithm is proposed to identify the corrective actions for all potential voltage violations in all contingency scenarios. The proposed method was tested and validated on a modified IEEE 118-bus system with solar photovoltaic (PV) data.

Photovoltaic, Volt/Var Control↗

First harmonic measurements of the spin Seebeck effect

We present measurements of the spin Seebeck effect (SSE) by a technique that combines alternating currents (AC) and direct currents (DC). The method is applied to a ferrimagnetic insulator/heavy metal bilayer, Y 3 Fe 5 O 12 (YIG)/Pt. Typically, SSE measurements use an AC current to produce an alternating temperature gradient and measure the voltage generated by the inverse spin-Hall effect in the heavy metal at twice the AC frequency. Here, we show that when Joule heating is associated with AC and DC bias currents, the SSE response occurs at the frequency of the AC current drive and can be larger than the second harmonic SSE response. We compare the first and second harmonic responses and show that they are consistent with the SSE. The field dependence of the voltage response is used to distinguish between the damping-like and field-like torques. This method can be used to explore nonlinear thermoelectric effects and spin dynamics induced by temperature gradients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro-inverter assembly for use in a photovoltaic system and method of making same

A micro-inverter assembly for use in a photovoltaic system includes a housing, a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing, and a DC connector electrically coupled to the DC-to-AC micro-inverter. The DC connector is positioned within a recess formed in a bottom surface of the housing such that at least one electrical contact of the DC connector is accessible from outside the housing. According to alternative embodiments, the DC connector comprises a plug-and-play connector constructed for one of a rotational engagement and a translational engagement with a DC connector of a photovoltaic (PV) panel.

Cioffi, Philip Michael↗

Electromagnetic form factors of the {lambda} and {sigma} baryons in an alternative baryonic current approach

Light-cone sum rules are used to investigate the electromagnetic form factors of the {lambda} and {sigma} baryons by using the Ioffe-type interpolating currents. The sum rules are affected to some extent by the choice of the interpolating currents from a comparison. Numerical calculations show that the magnetic form factor can be well fitted by the dipole formula for {sigma} but not for {lambda}. The magnetic form factor of {lambda} approaches zero with the momentum transfer faster than the dipole formula estimation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Penetration Power Electronics Grid: Modeling and Simulation Gap Analysis

Increased penetration of power electronics in the grid is happening through development of high-power drives (like in Type 3 or 4 wind turbines, industrial drives, etc.), high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTS), energy storage systems (ESSs), inverter-based renewables like solar and wind, electric vehicle chargers, and other technologies. Ongoing research and development in new power electronic technologies including, but not limited to, solid-state power substations (SSPS), extreme fast charging (XFC), solid-state transformers, and multi-port power electronics that integrate multiple sources/loads will further increase penetration levels. To ensure stakeholders can integrate high penetration of power electronic technologies safely and reliably requires tools and methods to assess and evaluate their impact on the grid. Objectives: This report surveys, assesses, and analyzes commercially available and open-source tools that can support the assessment and evaluation of power electronics in future grids with high penetration levels. The study includes aspects that range from power flow analysis to dynamics evaluation (including hardware-in-the-loop – HIL testing) for such systems. The challenges and gaps associated with the current generation of toolsets available to assess the technical impact of introducing high penetration of power electronics are reported. The method is summarized in Figure ES-1.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic system with improved DC connections and method of making same

A micro-inverter assembly includes a housing having an opening formed in a bottom surface thereof, and a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing at a position adjacent to the opening. The micro-inverter assembly further includes a micro-inverter DC connector electrically coupled to the DC-to-AC micro-inverter and positioned within the opening of the housing, the micro-inverter DC connector having a plurality of exposed electrical contacts.

14 SOLAR ENERGY↗

Advanced High-Fidelity Lumped EMT Grid Modelling & Comparison

There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.

Debnath, Suman↗

Field and current distributions and ac losses in superconducting strips

In this paper I discuss analytic and numerical calculations of the magnetic-field and sheet-current distributions in superconducting strips of width 2a and arbitrary thickness 2b at the center when the cross-section is an ellipse, a rectangle, and a shape intermediate between these limits. Using critical-state theory, I use several methods to determine the functional dependence of the ac transport-current losses upon F=I/I{sub c}, where I is the peak alternating current and I{sub c} is the critical current, and I discuss how this dependence can be affected by the cross-sectional shape, aspect ratio, and a flux-density-dependent critical current density J{sub c}(B).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oscillation phenomena of a plasma produced by an AC driven hot cathode

Amplitude of oscillating discharge current has been measured for Bernas-type ion source equipped with an alternating current heated hot tungsten filament cathode. Measurements have been made by changing the filament diameter from 0.2 mm to 0.7 mm, and by changing the DC discharge current from 0.1 A to 1.5 A. The fluctuation amplitude of the discharge current was found decreased as the diameter of the filament was enlarged. The fluctuation amplitude took the minimum value at a frequency from several hundred Hz to 1 kHz depending upon the filament diameter and DC discharge current. For example, the relative oscillation amplitude was the smallest at 1 kHz for 0.7 mm diameter filament. Increase in discharge current had reduced the minimum oscillation amplitude, and increased the frequency at which the oscillating amplitude took the minimum. Fundamental mechanisms relevant to these characteristics of oscillation amplitude of discharge current from an AC driven hot cathode filament are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fidelity Analysis of Complex Large-Scale Simulation Models of PEs (MARS) in Future Power Grids

With the proliferation of power electronic (PE)-based resources in the electric grid, there have been numerous different kinds of simulation models developed and studied to understand their dynamic behavior. Study of PE-based resources using each simulation model has its own distinct advantages and disadvantages. Therefore it is very important to carefully select the appropriate model for the evaluation of the PE-based resources. In this paper, one such effort is made to analyze the different types of models in the case of a multi-port autonomous reconfigurable solar power plant (MARS). The MARS integrates a hybrid photovoltaic (PV)-energy storage system (ESS) plant to high-voltage direct current (HVdc) system and transmission alternating current (ac) grid. The dynamic models are evaluated under different test cases varying the short-circuit ratio (SCR) and control algorithms. Recommendations are provided on the equipment study needs based on the analysis completed.

Marthi, Phani Ratna Vanamali↗

Locational Marginal Pricing in the Campus Power System at the Power Distribution Level

In the development of smart grid at distribution level, the realization of real-time nodal pricing is one of the key challenges. The research work in this paper implements and studies the methodology of locational marginal pricing at distribution level based on a real-world distribution power system. The pricing mechanism utilizes optimal power flow to calculate the corresponding distributional nodal prices. Both Direct Current Optimal Power Flow and Alternate Current Optimal Power Flow are utilized to calculate and analyze the nodal prices. The University of Denver campus power grid is used as the power distribution system test bed to demonstrate the pricing methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HOT PLASMA FROM SOLAR ACTIVE REGION CORES: A TEST OF AC AND DC CORONAL HEATING MODELS?

Direct current (DC) models of solar coronal heating invoke magnetic reconnection to convert magnetic free energy into heat, whereas alternating current (AC) models invoke wave dissipation. In both cases the energy is supplied by photospheric footpoint motions. For a given footpoint velocity amplitude, DC models predict lower average heating rates but greater temperature variability when compared to AC models. Therefore, evidence of hot plasma (T > 5 MK) in the cores of active regions could be one of the ways for current observations to distinguish between AC and DC models. We have analyzed data from the X-Ray Telescope (XRT) and the Atmospheric Imaging Assembly for 12 quiescent active region cores, all of which were observed in the XRT Be-thick channel. We did Differential Emission Measure (DEM) analysis and achieved good fits for each data set. We then artificially truncated the hot plasma of the DEM model at 5 MK and examined the resulting fits to the data. For some regions in our sample, the XRT intensities continued to be well-matched by the DEM predictions, even without the hot plasma. This truncation, however, resulted in unacceptable fits for the other regions. This result indicates that the hot plasma is present in these regions, even if the precise DEM distribution cannot be determined with the data available. We conclude that reconnection may be heating the hot plasma component of these active regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of AC Current Density on the Stress Corrosion Cracking Behavior and Mechanism of E690 High-Strength Steel in Simulated Seawater

In this work, we studied the impact of alternating current (AC) density on the stress corrosion cracking (SCC) behavior and mechanism of E690 high-strength steel in simulated seawater with electrochemical measurements, U-bend immersion tests and slow strain rate tensile tests. Results demonstrate that AC enhances both anodic and cathodic processes, especially localized anodic dissolution and hydrogen evolution, which manifests as the increase in i{sub corr} with AC current density rising. Therefore, AC leads to higher SCC susceptibility. Accordingly, SCC is dominated by anodic dissolution (AD) at low AC current density while in a mixed control of AD and hydrogen embrittlement (HE) at high AC current density as a result of increasing hydrogen concentration. Besides, 50 A/m{sup 2} corresponds to the threshold hydrogen concentration of the “hydrogen-induced plasticity to HE” transformation, which is due to the different interactions of dislocation and hydrogen.

36 MATERIALS SCIENCE↗

Investigation on Effect of Magnetic Field Dependency Coefficient of Critical Current Density on the AC Magnetizing Loss in HTS Tapes Exposed to External Field

High-temperature superconducting (HTS) technology is the most promising, advanced, and beneficial technological developments of the last two decades in terms of fabricating more efficient, compact, and reliable electrical power apparatus. The second-generation HTS wires are now quite competitive with traditional conductors from the cost point of view. In addition, they are of high interest in electrical machine manufacturing due to their unique merits such as high current density, high magnetic field, and low loss. The most significant issue for any superconducting devices which work with alternating current or magnetic field is the AC loss of the HTS tapes. Since HTS tapes are always exposed to an external magnetic field in electrical machine applications, it is vital to consider the effect of this external field on their AC magnetizing (ACMG) loss. It is well-known that external magnetic field decreases the current carrying capability of the wire. In real life, critical current density of HTS tapes is dependent to magnetic field but this dependency sometime was not considered in modeling stage in order to make it faster and simple. In this paper, the electromagnetic properties of HTS tapes for use in superconducting electric machines have been investigated with a particular focus on the ACMG loss of YBCO tapes. For this purpose, a two-dimensional finite element model has been implemented based on the H formulation in order to study the effect of dependency of critical current density to magnetic field on the variation of ACMG loss. The modeling results will be helpful for electrical machine designers to have a better understanding about this effect and have a more accurate estimate of ACMG loss in design stage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current-driven antivortex core resonance measured by the rectifying effect

We demonstrate the current-driven resonance of a single antivortex core confined in a cross-shaped Ni{sub 81}Fe{sub 19} wire. The antivortex core dynamics can be excited purely by spin transfer torque; therefore, it is significant to understand the current-induced magnetization dynamics. The antivortex core resonance can be measured from the frequency dependence of a rectified voltage generated by an alternating current application. We found that the resonance frequency and peak amplitude greatly depend on the external magnetic field. This result is in good agreement with micromagnetic simulation.

36 MATERIALS SCIENCE↗

Air pollution control residues from waste incineration: Current UK situation and assessment of alternative technologies

Current disposal options for APC residues in the UK and alternative treatment technologies developed world-wide have been reviewed. APC residues are currently landfilled in the UK where they undergo in situ solidification, although the future acceptability of this option is uncertain because the EU waste acceptance criteria (WAC) introduce strict limits on leaching that are difficult to achieve. Other APC residue treatment processes have been developed which are reported to reduce leaching to below relevant regulatory limits. The Ferrox process, the VKI process, the WES-PHix process, stabilisation/solidification using cementitious binders and a range of thermal treatment processes are reviewed. Thermal treatment technologies convert APC residues combined with other wastes into inert glass or glass-ceramics that encapsulate heavy metals. The waste management industry will inevitably use the cheapest available option for treating APC residues and strict interpretation and enforcement of waste legislation is required if new, potentially more sustainable technologies are to become commercially viable.

54 ENVIRONMENTAL SCIENCES↗

Dependence of the magnitude and direction of the persistent current on the magnetic flux in superconducting rings

The obtained periodic magnetic-field dependences I{sub c+}({phi}/{phi}{sub 0}) and I{sub c-}({phi}/{phi}{sub 0}) of the critical current measured in opposite directions on asymmetric superconducting aluminum rings has made it possible to explain previously observed quantum oscillations of dc voltage as a result of alternating current rectification. It was found that a higher rectification efficiency of both single rings and ring systems is caused by hysteresis of the current-voltage characteristics. The asymmetry of current-voltage characteristics providing the rectification effect is due to the relative shifts of the magnetic dependences I{sub c-}({phi}/{phi}{sub 0}) = I{sub c+}({phi}/{phi}{sub 0} + {delta}{phi}) of the critical current measured in opposite directions. This shift means that the position of I{sub c+}({phi}/{phi}{sub 0}) and I{sub c-}({phi}/{phi}{sub 0}) minima does not correspond to n + 0.5 magnetic flux {phi} quanta, which is in direct contradiction to measured Little-Parks resistance oscillations. Despite this contradiction, the amplitude I{sub c,an}({phi}/{phi}{sub 0}) = I{sub c+}({phi}/{phi}{sub 0}) - I{sub c-}({phi}/{phi}{sub 0}) of critical current anisotropy oscillations and its variations with temperature correspond to the expected amplitude of persistent current oscillations and its variations with temperature.

36 MATERIALS SCIENCE↗

Conceptual design of ELM control coils for the TCABR tokamak

An upgrade of the Tokamak à Chauffage Alfvén Brésilien (TCABR) is being designed to make it capable of creating a well controlled environment where the impact of resonant magnetic perturbation (RMP) fields on edge localised modes can be addressed over a wide range of (i) plasma shapes, (ii) divertor configurations, (iii) RMP coil geometries and (iv) perturbed magnetic field spectra. To this end, a unique set of in-vessel RMP coils is being designed and, in this work, their conceptual design is presented. This unique set of coils is composed of three toroidal arrays of coils on the low field side and three toroidal arrays of coils on the high field side. Each of these six toroidal arrays is composed of 18 coils thus allowing for the creation of RMP fields with toroidal mode numbers n ≤ 9 and with increased control of the poloidal mode number spectrum. To study dynamical effects of RMP fields of different toroidal mode numbers, all rotating simultaneously with different velocities, each of the 108 RMP coils will be powered independently by power supplies that can provide voltages of up to 4 kV and electric currents of up to 2 kA, with frequencies varying continuously from 0Hz up to 10kHz. A set of physical criteria were used to determine the optimal coil geometry and their respective number of turns to reduce the coil currents and voltages during operation with alternate current. Further, the conceptual design was carried out using both the vacuum approach (no plasma response) and the single-fluid response approach, which accounts for the response of a linear, single-fluid, visco-resistive plasma calculated using the M3D-C 1 code.