Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

User's guide to noise data acquisition and analysis programs for HP9845: Nicolet analyzers

A software interface package was written for use with a desktop computer and two models of single channel Fast Fourier analyzers. This software features a portable measurement and analysis system with several options. Two types of interface hardware can alternately be used in conjunction with the software. Either an IEEE-488 Bus interface or a 16-bit parallel system may be used. Two types of storage medium, either tape cartridge or floppy disc can be used with the software. Five types of data may be stored, plotted, and/or printed. The data types include time histories, narrow band power spectra, and narrow band, one-third octave band, or octave band sound pressure level. The data acquisition programming includes a front panel remote control option for the FFT analyzers. Data analysis options include choice of line type and pen color for plotting.

Mcgary, M. C.↗

Wind energy system time-domain (WEST) analyzers

A portable analyzer which simulates in real time the complex nonlinear dynamics of horizontal axis wind energy systems was constructed. Math models for an aeroelastic rotor featuring nonlinear aerodynamic and inertial terms were implemented with high speed digital controllers and analog calculation. This model was combined with other math models of elastic supports, control systems, a power train and gimballed rotor kinematics. A stroboscopic display system graphically depicting distributed blade loads, motion, and other aerodynamic functions on a cathode ray tube is included. Limited correlation efforts showed good comparison between the results of this analyzer and other sophisticated digital simulations. The digital simulation results were successfully correlated with test data.

Dreier, M. E.↗

Pioneer 10/11 data analysis of the plasma analyzer experiment

The Pioneer 10 plasma analyzer detected the 10 plasma torus. Evidence was found of corotating ions which appear to be primarily S (++) and O (++) in the Pioneer 10 plasma data as the spacecraft moved inward from 6.9 to 5.4 R sub J. The Pioneer plasma analyzer was effective in obtaining information on the heavy ion populations in the Jovian magnetosphere. Interplanetary solar wind plasma shocks can trap energetic particles (cosmic rays) for weeks and out to distances of 17 AU. Energetic particles (o.5 MeV to 20 MeV) were confined between two plasma shocks from solar flares as the shocks propagated outward in the solar system.

Intriligator, D. S.↗

Automated analyzer for aircraft measurements of atmospheric methane and total hydrocarbons

An automated methane/total hydrocarbon analyzer is presented, which can produce alternate methane/total hydrocarbon measurements every 7 seconds to provide the spatial resolution required for regional hydrocarbon measurements at aircraft speeds. The construction and sampling techniques developed for the aircraft mounted system are discussed. A technique to periodically measure atmosphere oxygen is incorporated into the analyzer to ensure accurate hydrocarbon measurements, and a data collection methodology is developed to minimize errors resulting from changes in flame ionization detector sensitivity at different altitudes. Aircraft data acquired at the 1979 Southeastern Virginia Urban Plume Study are also presented, which illustrate the application of the instrument to a troposphere pollution plume.

Cofer, W. R., III↗

Thermal Radiation Analyzer System

Thermal Radiation Analyzer System, TRASYS/II, is computer software system with generalized capability to solve radiation-related aspects of thermal-analysis problems. When used in conjunction with generalized thermalanalysis program, such as Systems Improved Numerical Differencing Analyzer (SINDA) program, any thermal problem expressed in terms of lumped-parameter RC thermal network solved.

Skladany, J.↗

A revised version of the transfer matrix method to analyze one-dimensional structures

A new and general method to analyze both free and forced vibration characteristics of one-dimensional structures is discussed in this paper. This scheme links for the first time the classical transfer matrix method with the recently developed integrating matrix technique to integrate systems of differential equations. Two alternative approaches to the problem are presented. The first is based upon the lumped parameter model to account for the inertia properties of the structure. The second releases that constraint allowing a more precise description of the physical system. The free vibration of a straight uniform beam under different support conditions is analyzed to test the accuracy of the two models. Finally some results for the free vibration of a 12th order system representing a curved, rotating beam prove that the present method is conveniently extended to more complicated structural dynamics problems.

Nitzsche, F.↗

Thermal Radiation Analyzer

Thermal Radiation Analyzer System TRASYS II solves radiation related aspects of thermal analysis problems. TRASYS II provides for calculation of internode radiation interchange data and for calculation of incident and absorbed heat rate data originating from environmental radiant heat sources. When TRASYS II used in conjunction with generalized thermal analysis program such as Systems Improved Numerical Differencing Analyzer (SINDA), any thermal problem expressed in terms of lumped parameter RC thermal network solved.

Vogt, R. A.↗

A portable x-ray analyzer for wearmetal particles in lubricants

An extensive program exists for the systematic sampling and analysis of lubricants in U.S. Air Force aircraft engines. The sudden development of excessive engine wear can usually be detected on the basis of monitoring the concentration of several key metallic elements for each aircraft engine. In many cases even the specific fault within an engine can be recognized. The two types of equipment which are currently being employed for the conduction of oil analyses make use of atomic emission or atomic absorption spectroscopy. In both cases, heavy, large, and relatively fragile pieces of equipment are involved. Difficulties concerning the transportation of these devices have led to the development of a small, sturdy, and easily portable wearmetal analyzer. The analyzer makes use of an X-ray fluorescence technique.

Clark, B. C.↗

The Statistical Loop Analyzer (SLA)

The statistical loop analyzer (SLA) is designed to automatically measure the acquisition, tracking and frequency stability performance characteristics of symbol synchronizers, code synchronizers, carrier tracking loops, and coherent transponders. Automated phase lock and system level tests can also be made using the SLA. Standard baseband, carrier and spread spectrum modulation techniques can be accomodated. Through the SLA's phase error jitter and cycle slip measurements the acquisition and tracking thresholds of the unit under test are determined; any false phase and frequency lock events are statistically analyzed and reported in the SLA output in probabilistic terms. Automated signal drop out tests can be performed in order to trouble shoot algorithms and evaluate the reacquisition statistics of the unit under test. Cycle slip rates and cycle slip probabilities can be measured using the SLA. These measurements, combined with bit error probability measurements, are all that are needed to fully characterize the acquisition and tracking performance of a digital communication system.

Lindsey, W. C.↗

Numerical methods for analyzing electromagnetic scattering

Numerical methods to analyze electromagnetic scattering are presented. The dispersions and attenuations of the normal modes in a circular waveguide coated with lossy material were completely analyzed. The radar cross section (RCS) from a circular waveguide coated with lossy material was calculated. The following is observed: (1) the interior irradiation contributes to the RCS much more than does the rim diffraction; (2) at low frequency, the RCS from the circular waveguide terminated by a perfect electric conductor (PEC) can be reduced more than 13 dB down with a coating thickness less than 1% of the radius using the best lossy material available in a 6 radius-long cylinder; (3) at high frequency, a modal separation between the highly attenuated and the lowly attenuated modes is evident if the coating material is too lossy, however, a large RCS reduction can be achieved for a small incident angle with a thin layer of coating. It is found that the waveguide coated with a lossy magnetic material can be used as a substitute for a corrugated waveguide to produce a circularly polarized radiation yield.

Lee, S. W.↗

Response characteristics of laser diffraction particle size analyzers - Optical sample volume extent and lens effects

The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.

Hirleman, E. D.↗

The Medium-energy particle analyzer (MEPA) on the AMPTE CCE spacecraft

A major objective in the design of the Charge Composition Explorer (CCE) is related to the measurement of small fluxes of ions (lithium and barium) injected in the solar wind and the deep magnetotail. A second important objective is concerned with the comprehensive measurement of the composition and dynamics of the natural-particle population. The medium-energy particle analyzer (MEPA) in the CCE is designed to cover an energy range which is normally covered by electrostatic analyzers. In order to prevent saturation by the large magnetospheric fluxes of low-energy protons, the MEPA sensor was designed to have a low efficiency for protons, but a high efficiency for the rarer heavier nuclei. The considered aims could be achieved by developing a technology, new to space flight, for measuring energetic ion composition. Particle mass is determined on the basis of the measurement of particle time of flight and total energy.

Mcentire, R. W.↗

A wide-band, high-resolution spectrum analyzer

A million-channel, 20 MHz-bandwidth, digital spectrum analyzer under evelopment for use in the SETI Sky Survey and other applications in the Deep Space Network is described. The analyzer digitizes an analog input, performs a 2(20)-point Radix-2, Fast Fourier Transform, accumulates the output power, and normalizes the output to remove frequency-dependent gain. The effective speed of the real-time hardware is 2.2 GigaFLOPS.

Wilck, H. C.↗

Comparison of vertical velocities analyzed by a numerical model and measured by a VHF wind profiler

The use of wind profilers for measuring vertical velocities in the troposphere and lower stratosphere is potentially of great interest for verification of forecasts, diagnosis of mesoscale circulations, and studies of wave motions. The studies of profiler vertical velocities to date have shown that the observed patterns of ascent and subsidence are reasonable when compared to the synoptic conditions. However, difficulties arise when a direct verification of the profiler vertical winds is sought. Since no other technique can measure the vertical velocities over the same height range and with the same claimed accuracy as the profilers, direct comparisons are impossible. The only alternative is to compare the measurements to analyzed vertical velocity fields. Here, researchers compare vertical measurements made with the SOUSY VHF radar over a period of 11 days at the beginning of November 1981 to the analyzed vertical velocities produced by the European Center for Medium-range Weather Forecasting (ECMWF) model for grid points near the radar site.

Larsen, M. F.↗

A study of methods to predict and measure the transmission of sound through the walls of light aircraft. Numerical method for analyzing the optimal performance of active noise controllers

An optimal active noise controller is formulated and analyzed for three different active noise control problems. The first problem formulated is the active control of enclosed or partially enclosed harmonic sound fields where the noise source strengths and enclosure boundary description are known. The enclosure boundary is described by either pressure, velocity, or impedance boundary conditions. The second problem formulated is the active control of the free field power radiated from a distributed noise source with a known time harmonic surface velocity. The third problem formulated is the active control of enclosed or partially enclosed harmonic sound field where the noise source strengths of enclosure boundary description may not be known. All three formulations are derived using an indirect boundary element technique. Formulation and verification of an indirect boundary element method is presented. The active noise controller formulations for enclosures are capable of analyzing systems with generalized enclosure shapes, point noise sources, and/or locally reacting impedance boundary conditions. For each formulation, representative results of optimal active noise controller case studies are presented, and some general conclusions are drawn.

Mollo, Christopher G.↗

Stigmatically focusing partial pressure analyzer with dual chamber ion source

The partial pressure analyzer developed has a high absolute sensitivity and high resolution. Interaction effects, as they occur in conventional partial pressure analyzers between the heating filament for the emission of electrons and the residual gas, are suppressed by removing the heating filament from the measurement area. The electron beam is generated in an auxiliary vacuum compartment, and passes subsequently through an aperture into the ionization compartment. The probability is small, therefore, that the presence of substances produced at the heating filament by chemical reactions and thermal decompositions will have disturbing effects. The high sensitivity and resolution of the instrument are obtained with the aid of an electron path configuration of unconventional characteristics.

Rasskopf, Klaus F.↗

Experimental tests of a toroidal electrostatic analyzer

A toroidal electrostatic analyzer of a design suitable for space plasma instrumentation has been constructed and tested. Experimental results are compared with second-order ion optical theory and are in good agreement. Verifying the ion optics of the toroid was simplified by use of a position-sensing microchannel-plate detector mounted on a positioning system with three translational degrees of freedom located at the toroid exit. The toroidal analyzer described here is the first optical element in a fully toroidal mass spectrograph intended for analysis of kilovolt magnetospheric plasmas.

Young, D. T.↗