Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comparison of vertical velocities analyzed by a numerical model and measured by a VHF wind profiler

The use of wind profilers for measuring vertical velocities in the troposphere and lower stratosphere is potentially of great interest for verification of forecasts, diagnosis of mesoscale circulations, and studies of wave motions. The studies of profiler vertical velocities to date have shown that the observed patterns of ascent and subsidence are reasonable when compared to the synoptic conditions. However, difficulties arise when a direct verification of the profiler vertical winds is sought. Since no other technique can measure the vertical velocities over the same height range and with the same claimed accuracy as the profilers, direct comparisons are impossible. The only alternative is to compare the measurements to analyzed vertical velocity fields. Here, researchers compare vertical measurements made with the SOUSY VHF radar over a period of 11 days at the beginning of November 1981 to the analyzed vertical velocities produced by the European Center for Medium-range Weather Forecasting (ECMWF) model for grid points near the radar site.

Larsen, M. F.↗

A study of methods to predict and measure the transmission of sound through the walls of light aircraft. Numerical method for analyzing the optimal performance of active noise controllers

An optimal active noise controller is formulated and analyzed for three different active noise control problems. The first problem formulated is the active control of enclosed or partially enclosed harmonic sound fields where the noise source strengths and enclosure boundary description are known. The enclosure boundary is described by either pressure, velocity, or impedance boundary conditions. The second problem formulated is the active control of the free field power radiated from a distributed noise source with a known time harmonic surface velocity. The third problem formulated is the active control of enclosed or partially enclosed harmonic sound field where the noise source strengths of enclosure boundary description may not be known. All three formulations are derived using an indirect boundary element technique. Formulation and verification of an indirect boundary element method is presented. The active noise controller formulations for enclosures are capable of analyzing systems with generalized enclosure shapes, point noise sources, and/or locally reacting impedance boundary conditions. For each formulation, representative results of optimal active noise controller case studies are presented, and some general conclusions are drawn.

Mollo, Christopher G.↗

Stigmatically focusing partial pressure analyzer with dual chamber ion source

The partial pressure analyzer developed has a high absolute sensitivity and high resolution. Interaction effects, as they occur in conventional partial pressure analyzers between the heating filament for the emission of electrons and the residual gas, are suppressed by removing the heating filament from the measurement area. The electron beam is generated in an auxiliary vacuum compartment, and passes subsequently through an aperture into the ionization compartment. The probability is small, therefore, that the presence of substances produced at the heating filament by chemical reactions and thermal decompositions will have disturbing effects. The high sensitivity and resolution of the instrument are obtained with the aid of an electron path configuration of unconventional characteristics.

Rasskopf, Klaus F.↗

Experimental tests of a toroidal electrostatic analyzer

A toroidal electrostatic analyzer of a design suitable for space plasma instrumentation has been constructed and tested. Experimental results are compared with second-order ion optical theory and are in good agreement. Verifying the ion optics of the toroid was simplified by use of a position-sensing microchannel-plate detector mounted on a positioning system with three translational degrees of freedom located at the toroid exit. The toroidal analyzer described here is the first optical element in a fully toroidal mass spectrograph intended for analysis of kilovolt magnetospheric plasmas.

Young, D. T.↗

Compact wide-aperture hyperbolic analyzers

Compact electrostatic analyzers that employ a new geometry are described. They accept collimated beams of ions through relatively wide (non-slit-like) inlet apertures and focus them at various locations, depending on the ion energy per charge, along rectangular position-sensing detectors. Each analyzer has a dynamic range of 10 or more for a fixed deflection voltage. The focal line width at a given energy is a small fraction of the inlet aperture width, and the focal lines are approximately coplanar.

Curtis, C. C.↗

Miniature PCM compatible wideband spectral analyzer for hypersonic flight research

The design concept and prototype performance of a 10-400-kHz wideband spectral analyzer being developed at NASA Langley as part of the Hypersonic Flight Instrumentation Research Experiment are described and illustrated with diagrams and graphs. The analyzer is intended to compress the bandwidth of data from up to 20 hot-film anemometers, so that the analog PSD waveform from each sensor can be encoded for serial PCM telemetry. Components include an analog multiplier, digital waveform generator, sine-wave VCO, digital VCO, analog low-pass filter, switched-capacitor filter, and rms-dc detector. The prototype demonstrated 1-percent accuracy (referred to a 5-V full-scale output) for sweep rates up to 3/sec over the 10-400-kHz spectrum.

Diamond, John K.↗

W-band six-port network analyzer for two-port characterization of millimeter wave transistors

A W-band (75-100 GHz) six-port junction network analyzer was constructed from commercially available descrete waveguide components and was used for the direct two-port S-parameter measurement of active three-terminal devices. A comparison between the six-port and a down-converter-type frequency extender for a conventional network analyzer revealed the superior performance of the six-port. The application of the six-port to characterize a 0.1-micron gate-length HEMT at W-band is described, and representative results are presented.

Moeller, Karl J.↗

Modal techniques for analyzing airplane dynamics

A series of techniques are presented for analyzing airplane control and output characteristics. State-space matrix equations describing the linear perturbation dynamics are transformed from physical coordinates into scaled, modal coordinates. Techniques for analyzing the impacts of system inputs on the fundamental modes of motion and the appearance of these modes in the system outputs are explained. Scaled modal matrices are used to compute steady-state control inputs which optimize the steady-state response of selected system outputs. Graphics which promote quick understanding of the analysis are presented to display the resulting vectors and matrices. The defined analysis techniques are applied to an example airplane model, illustrating the insight which can be acquired using the described modal techniques.

Arbuckle, P. Douglas↗

Some easily analyzable convolutional codes

Convolutional codes have played and will play a key role in the downlink telemetry systems on many NASA deep-space probes, including Voyager, Magellan, and Galileo. One of the chief difficulties associated with the use of convolutional codes, however, is the notorious difficulty of analyzing them. Given a convolutional code as specified, say, by its generator polynomials, it is no easy matter to say how well that code will perform on a given noisy channel. The usual first step in such an analysis is to computer the code's free distance; this can be done with an algorithm whose complexity is exponential in the code's constraint length. The second step is often to calculate the transfer function in one, two, or three variables, or at least a few terms in its power series expansion. This step is quite hard, and for many codes of relatively short constraint lengths, it can be intractable. However, a large class of convolutional codes were discovered for which the free distance can be computed by inspection, and for which there is a closed-form expression for the three-variable transfer function. Although for large constraint lengths, these codes have relatively low rates, they are nevertheless interesting and potentially useful. Furthermore, the ideas developed here to analyze these specialized codes may well extend to a much larger class.

Mceliece, R.↗

Two-Dimensional Acousto-Optical Spectrum Analyzer

State-of-the-art two-dimensional acousto-optical spectrum analyzer processes input radio-frequency signal in real time into components in any number of spectral channels up to about 10(Sup5). Input radio-frequency signal to be analyzed launched via transducer into acousto-optical device along x axis. Acousto-optical device becomes Bragg cell. Pulsed plane waves of light from laser aimed at Bragg cell, which spatially modulates phases of plane waves and diffracts waves according to pattern of acoustic signal.

Ansari, Homayoon↗

Simplified Digital Spectrum Analyzer

Spectrum analyzer computes approximate cross-correlations between noisy input signal and reference signal of known frequency, yielding measure of amplitude of sinusoidal component of input. Complexity and power consumed less than other digital spectrum analyzers. Performs no multiplications, and because processes data on each frequency independently, focuses on narrow spectral range without processing data on rest of spectrum.

Cole, Steven W.↗

Combined Backscatter Moessbauer Spectrometer and X Ray Fluorescence analyzer (BaMS/XRF) for planetary surface materials

A backscatter Moessbauer spectrometer (BaMS) with included x ray fluorescence (XRF) capability for the Mars Environment Survey (MESUR) Mission, which has been proposed by NASA for 1998, is being developed. The instrument will also be suitable for other planetary missions such as those to the Moon, asteroids, and other solid solar-system objects. The BaMS would be unique for MESUR in providing information about iron mineralogy in rocks, clays, and other surface materials, including relative proportions of iron-bearing minerals. It requires no sample preparation and can identify all the normal oxidation states of iron (3+, 2+, 0). Thus, BaMS is diagnostic for weathering and other soil-forming processes. Backscatter design allows the addition of XRF elemental analysis with little or no modification. The BaMS/XRF instrument complements the thermal analyzer with evolved gas analyzer (TA-EGA) and the alpha-proton x-ray spectrometer (APXS) proposed (along with BaMS) for geochemical analysis on MESUR.

Agresti, D. G.↗

A 640-MHz 32-megachannel real-time polyphase-FFT spectrum analyzer

A polyphase fast Fourier transform (FFT) spectrum analyzer being designed for NASA's Search for Extraterrestrial Intelligence (SETI) Sky Survey at the Jet Propulsion Laboratory is described. By replacing the time domain multiplicative window preprocessing with polyphase filter processing, much of the processing loss of windowed FFTs can be eliminated. Polyphase coefficient memory costs are minimized by effective use of run length compression. Finite word length effects are analyzed, producing a balanced system with 8 bit inputs, 16 bit fixed point polyphase arithmetic, and 24 bit fixed point FFT arithmetic. Fixed point renormalization midway through the computation is seen to be naturally accommodated by the matrix FFT algorithm proposed. Simulation results validate the finite word length arithmetic analysis and the renormalization technique.

Zimmerman, G. A.↗

Finite grid radius and thickness effects on retarding potential analyzer measured suprathermal electron density and temperature

The effect of finite grid radius and thickness on the electron current measured by planar retarding potential analyzers (RPAs) is analyzed numerically. Depending on the plasma environment, the current is significantly reduced below that which is calculated using a theoretical equation derived for an idealized RPA having grids with infinite radius and vanishingly small thickness. A correction factor to the idealized theoretical equation is derived for the Pioneer Venus (PV) orbiter RPA (ORPA) for electron gasses consisting of one or more components obeying Maxwell statistics. The error in density and temperature of Maxwellian electron distributions previously derived from ORPA data using the theoretical expression for the idealized ORPA is evaluated by comparing the densities and temperatures derived from a sample of PV ORPA data using the theoretical expression with and without the correction factor.

Knudsen, William C.↗

BETA: Behavioral testability analyzer and its application to high-level test generation and synthesis for testability

In this thesis, a behavioral-level testability analysis approach is presented. This approach is based on analyzing the circuit behavioral description (similar to a C program) to estimate its testability by identifying controllable and observable circuit nodes. This information can be used by a test generator to gain better access to internal circuit nodes and to reduce its search space. The results of the testability analyzer can also be used to select test points or partial scan flip-flops in the early design phase. Based on selection criteria, a novel Synthesis for Testability approach call Test Statement Insertion (TSI) is proposed, which modifies the circuit behavioral description directly. Test Statement Insertion can also be used to modify circuit structural description to improve its testability. As a result, Synthesis for Testability methodology can be combined with an existing behavioral synthesis tool to produce more testable circuits.

Chen, Chung-Hsing↗

Theory and operation of a three-gate time-of-flight velocity analyzer

Theoretical considerations and test results are presented for a new-type velocity analyzer for incident fast neutral particles, positive ions, and negative ions. Velocity analysis is carried out by means of a pulsed, three-gate time-of-flight (TOF) technique capable of eliminating alias velocities (harmonics) to sixth order. In addition the design and operation are presented of a four-element ion lens system, with small spherical and chromatic aberrations, suitable for interfacing a large-diameter ion beam from the TOF section with a subsequent mass analyzer.

Martus, K. E.↗

Analyzing high dimensional data

Problems encountered in analyzing high dimensional data are discussed and possible solutions are proposed. The increased importance of second-order statistics in analyzing high dimensional data and the shortcoming of the minimum distance classifier in high dimensional data are recognized. By investigating characteristics of high dimensional data, it is shown that second-order statistics must be taken into account in high dimensional data. There is a need to represent second order statistics effectively. As the data dimensionality increases, it becomes more difficult to perceive and compare information present in statistics derived from data. In order to overcome this problem, a method to visualize statistics using color code is proposed. By representing statistics using a color code, the first and the second statistics can be more readily compared.

Lee, Chulhee↗

The NACA mixture analyzer and its application to mixture-distribution measurement in flight

The NACA mixture analyzer was developed as a research instrument for the continuous indication of fuel-air ratios of aircraft engine installations throughout the range of engine operation. It has been evaluated by using it to measure the mixture distribution of a nine-cylinder radial aircraft engine in flight. The mixture distribution among the cylinders in flight was obtained at normal operating conditions for the engine at an altitude of 5000 feet. Some limited data was also obtained at an altitude of 20,000 feet. Results of these flight tests showed that the NACA mixture analyzer is a satisfactory and dependable instrument for continuous indication of the mixture in flight at all engine conditions regardless of altitude and temperature.

Gerrish, Harold C↗