Energy resolution of the photoemission analyzer
Photoemission analyzer with finite emitter in spherically symmetric retarding field with magnetic field present, analyzing energy resolution
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Photoemission analyzer with finite emitter in spherically symmetric retarding field with magnetic field present, analyzing energy resolution
Automated fluid chemical analyzer for microchemical analysis of small quantities of liquids by use of selected reagents and analyzer units
Scientific requirements necessary to develop a spectral analyzer for monitoring mammalian subjects, are discussed. The analyzer measures dynamic or time dependent data as a measure of the subjects operating status. Measurable data include metabolic rate, body temperature, and blood constituents like glucose, oxygen, and carbon dioxide, and lactic acid. Metabolic cycles were found with periodicities in the range of minutes and hours; longer cycles in body weight (3 1/2 days and 60 days), indicative of metabolic processes, were also found.
Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.
A flight-worthy pulse height analyzer that has a quadratic transfer function is described. This quadratic function permits optimum usage of the entire PHA dynamic range due to the quadratic nature of the gamma ray spectrometer's resolution vs energy. After the theoretical design discussion, the implementation of the design is examined and test results described. The analyzer is part of the University of New Hampshire gamma ray monitor for OSO-H.
The Modular Thermal Analyzer Routine (MOTAR) is a general thermal analysis routine with strong capabilities for performing thermal analysis of systems containing flowing fluids, fluid system controls (valves, heat exchangers, etc.), life support systems, and thermal radiation situations. Its modular organization permits the analysis of a very wide range of thermal problems for simple problems containing a few conduction nodes to those containing complicated flow and radiation analysis with each problem type being analyzed with peak computational efficiency and maximum ease of use. The organization and programming methods applied to MOTAR achieved a high degree of computer utilization efficiency in terms of computer execution time and storage space required for a given problem. The computer time required to perform a given problem on MOTAR is approximately 40 to 50 percent that required for the currently existing widely used routines. The computer storage requirement for MOTAR is approximately 25 percent more than the most commonly used routines for the most simple problems but the data storage techniques for the more complicated options should save a considerable amount of space.
The analysis of ion data from retarding potential analyzers (RPA's) is generally done under the planar approximation, which assumes that the grid transparency is constant with angle of incidence and that all ions reaching the plane of the collectors are collected. These approximations are not valid for situations in which the ion thermal velocity is comparable to the vehicle velocity, causing ions to enter the RPA with high average transverse velocity. To investigate these effects, the current-voltage curves for H+ at 4000 K were calculated, taking into account the finite collector size and the variation of grid transparency with angle. These curves are then analyzed under the planar approximation. The results show that only small errors in temperature and density are introduced for an RPA with typical dimensions; and that even when the density error is substantial for non-typical dimensions, the temperature error remains minimal.
A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.
The primary electron spectrometer used to detect auroral electrons on sounding rocket 18:63 UE is described. The spectrometer used exponentially decaying positive and negative voltages applied to spherical deflection plates for energy analysis. A method for determining the analyzer response which does not require the assumptions that the ratio of plate separation to mean radius, the entrance or the exit apertures are small is described. By comparison with experiment it is shown that the effect of neither entrance nor exit collimation can be ignored. The experimental and calculated values of the limiting orbits agree well. A non-iterative technique of unfolding the electron differential energy spectrum is described. This method does not require the usual assumption of a flat or histogram-type energy spectrum. The unfolded spectra using both this technique and one which assumes a flat spectrum are compared to actual input spectra. This technique is especially useful in analyzing peaked auroral electron energy spectra.
The operation and properties of various mass-spectrometer residual gas analyzers for use in vacuum measurements were analyzed in terms of efficiencies of ion extraction, ion separation and transmission, and ion collection. Types of instruments studied were magnetic sector, omegatron, quadrupole, and monopole. Experimental results presented include absolute sensitivity to argon, relative sensitivity to 10 gases, and cracking patterns for these gases. It is shown that the properties are strongly dependent on instrument range, resolution, and the particular voltages, currents, or field intensities used to control the instrument.
The electron collecting efficiency of a cylindrical mirror energy analyzer incorporating retardation of the electrons prior to analysis has been determined over the range 0 to 30 eV by two methods. The first method requires the use of a vacuum ultraviolet monochromator to produce monoenergetic electrons of different energies; the second method involves measuring the energy-brightness relationship of the retarding optics and should be applicable to any deflection analyzer with pre-retarding optics. The results of the two methods are compared and the limitations of the latter method are discussed.
Analyzer employs chemical-sensing electrodes for determination of blood, gas, and ion concentrations. It is rugged, easily serviced, and comparatively simple to operate. System can analyze up to eight parameters and can be modified to measure other blood constituents including nonionic species, such as urea, glucose, and oxygen.
A computer program was developed which has the ability to analyze the performance of most light suppression systems so as to predict the amount of scattered light which will reach the image plane for various conditions of unwanted light input from the sun, earth, or moon. This program was used to analyze three different configurations of the large space telescope (LST): an LST with a truncated sunshield, an LST with an extended cylindrical sunshield, and an LST with a conical sunshield which is tilted upwards. The computer program gives the user detailed information as to the paths taken by the unwanted stray light to reach the image plane, and pinpoints those portions of the light suppression system which contribute most of the stray light, so that areas requiring improvements are evident. Certain design guide lines were formulated for any light suppression system selected for the LST, and one which meets these requirements (the tilted sunshade) is described in detail.
This paper describes the application of a numerical differencing analyzer computer program to the thermal analyzation of a MIUS model. The MIUS model which was evaluated is one which would be required to support a 648-unit Garden Apartment Complex. This computer program was capable of predicting the thermal performance of this MIUS from the impressed electrical, heating, and cooling loads.
The electron collecting efficiency of a cylindrical mirror energy analyzer incorporating retardation of the electrons prior to analysis has been determined over the range 0 to 30 eV by two methods. The first method requires the use of a vacuum ultraviolet monochromator to produce monoenergetic electrons of different energies; the second method involves measuring the energy-brightness relationship of the retarding optics and should be applicable to any deflection analyzer with pre-retarding optics. The results of the two methods are compared and the limitations of the latter method are discussed.
The theoretical model accounts for drift and cyclotron components of ion motion in a partially ionized plasma. Density and velocity distributions are systematically prescribed. The flux into the neutral particle analyzer (NPA) from this plasma is determined by summing over all charge exchange neutrals in phase space which are directed into apertures. Calculation of the process is continued through the NPA using appropriate cross section data to obtain analyzer output distributions. Theoretical results were compared with NPA measurements on four plasma heating devices having radial electric, E, and axial magnetic, B, fields. Drift velocity, in the azimuthal direction is identified with E/B. Selection of randomized cyclotron velocity distributions about mean azimuthal drift yield energy distributions which compare well with experiment.
The effects of the grid transparency and finite collector size on the values of thermal ion density and temperature determined by the standard RPA (retarding potential analyzer) analysis method are investigated. The current-voltage curves calculated for varying RPA parameters and a given ion mass, temperature, and density are analyzed by the standard RPA method. It is found that only small errors in temperature and density are introduced for an RPA with typical dimensions, and that even when the density error is substantial for nontypical dimensions, the temperature error remains minimum.
A cascade particulate analyzer was developed for nearly real time measurement of the contaminating particulate size distribution in the spacecraft interior ambient environment and as a real time total impacting particulate mass monitor under vacuum conditions. The analyzer has four stages, the first stage is a basic 10 MHz quartz crystal microbalance used widely on spacecraft (such as Skylab) for contamination monitoring purposes. In this application the front sensing crystal is coated with a low vapor pressure adhesive grease which captures impacting particles. This first stage has a wide viewing angle and measures total particulate mass impacting the crystal while the unit is exposed to the vacuum environment. The remaining three states form an aerodynamic impaction cascade with individual quartz crystal microbalances at each stage acting as accumulated mass sensing elements. These three stages thus give relative mass distribution of particulates in three ranges, particles having effective diameter greater than 5 micron, particles between 1 and 5 micron diameter and particles 0.3 to 1 micron diameter.