Search NASA⌕ Search

SEARCH · Search NASA

Results for “Anonymization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner

Purpose: The highest photon fluence rate that a computed tomography (CT) detector must be able to measure is an important parameter. The authors calculate the maximum transmitted fluence rate in a commercial CT scanner as a function of patient size for standard head, chest, and abdomen protocols. Methods: The authors scanned an anthropomorphic phantom (Kyoto Kagaku PBU-60) with the reference CT protocols provided by AAPM on a GE LightSpeed VCT scanner and noted the tube current applied with the tube current modulation (TCM) system. By rescaling this tube current using published measurements on the tube current modulation of a GE scanner [N. Keat, “CT scanner automatic exposure control systems,” MHRA Evaluation Report 05016, ImPACT, London, UK, 2005], the authors could estimate the tube current that these protocols would have resulted in for other patient sizes. An ECG gated chest protocol was also simulated. Using measured dose rate profiles along the bowtie filters, the authors simulated imaging of anonymized patient images with a range of sizes on a GE VCT scanner and calculated the maximum transmitted fluence rate. In addition, the 99th and the 95th percentiles of the transmitted fluence rate distribution behind the patient are calculated and the effect of omitting projection lines passing just below the skin line is investigated. Results: The highest transmitted fluence rates on the detector for the AAPM reference protocols with centered patients are found for head images and for intermediate-sized chest images, both with a maximum of 3.4 ⋅ 10{sup 8} mm{sup −2} s{sup −1}, at 949 mm distance from the source. Miscentering the head by 50 mm downward increases the maximum transmitted fluence rate to 5.7 ⋅ 10{sup 8} mm{sup −2} s{sup −1}. The ECG gated chest protocol gives fluence rates up to 2.3 ⋅ 10{sup 8} − 3.6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} depending on miscentering. Conclusions: The fluence rate on a CT detector reaches 3 ⋅ 10{sup 8} − 6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} in standard imaging protocols, with the highest rates occurring for ECG gated chest and miscentered head scans. These results will be useful to developers of CT detectors, in particular photon counting detectors.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

SU-F-J-84: Comparison of Quantitative Deformable Image Registration Evaluation Tools: Application to Prostate IGART

Purpose: Errors in displacement vector fields (DVFs) generated by Deformable Image Registration (DIR) algorithms can give rise to significant uncertainties in contour propagation and dose accumulation in Image-Guided Adaptive Radiotherapy (IGART). The purpose of this work is to assess the accuracy of two DIR algorithms using a variety of quality metrics for prostate IGART. Methods: Pelvic CT images were selected from an anonymized database of nineteen prostate patients who underwent 8–12 serial scans during radiotherapy. Prostate, bladder, and rectum were contoured on 34 image-sets for three patients by the same physician. The planning CT was deformably-registered to daily CT using three variants of the Small deformation Inverse Consistent Linear Elastic (SICLE) algorithm: Grayscale-driven (G), Contour-driven (C, which utilizes segmented structures to drive DIR), combined (G+C); and also grayscale ITK demons (Gd). The accuracy of G, C, G+C SICLE and Gd registrations were evaluated using a new metric Edge Gradient Distance to Agreement (EGDTA) and other commonly-used metrics such as Pearson Correlation Coefficient (PCC), Dice Similarity Index (DSI) and Hausdorff Distance (HD). Results: C and G+C demonstrated much better performance at organ boundaries, revealing the lowest HD and highest DSI, in prostate, bladder and rectum. G+C demonstrated the lowest mean EGDTA (1.14 mm), which corresponds to highest registration quality, compared to G and C DVFs (1.16 and 2.34 mm). However, demons DIR showed the best overall performance, revealing lowest EGDTA (0.73 mm) and highest PCC (0.85). Conclusion: As expected, both C- and C+G SICLE more accurately reproduce manually-contoured target datasets than G-SICLE or Gd using HD and DSI metrics. In general, the Gd appears to have difficulty reproducing large daily position and shape changes in the rectum and bladder. However, Gd outperforms SICLE in terms of EGDTA and PCC metrics, possibly at the expense of topological quality of the estimated DVFs.

60 APPLIED LIFE SCIENCES↗

SU-F-T-115: Uncertainty in the Esophagus Dose in Retrospective Epidemiological Study of Breast Cancer Radiotherapy Patients

Purpose: Epidemiological studies of second cancer risks in breast cancer radiotherapy patients often use generic patient anatomy to reconstruct normal tissue doses when CT images of patients are not available. To evaluate the uncertainty involved in the dosimetry approach, we evaluated the esophagus dose in five sample patients by simulating breast cancer treatments. Methods: We obtained the diagnostic CT images of five anonymized adult female patients in different Body Mass Index (BMI) categories (16– 36kg/m2) from National Institutes of Health Clinical Center. We contoured the esophagus on the CT images and imported them into a Treatment Planning System (TPS) to create treatment plans and calculate esophagus doses. Esophagus dose was calculated once again via experimentally-validated Monte Carlo (MC) transport code, XVMC under the same geometries. We compared the esophagus doses from TPS and the MC method. We also investigated the degree of variation in the esophagus dose across the five patients and also the relationship between the patient characteristics and the esophagus doses. Results: Eclipse TPS using Analytical Anisotropic Algorithm (AAA) significantly underestimates the esophagus dose in breast cancer radiotherapy compared to MC. In the worst case, the esophagus dose from AAA was only 40% of the MC dose. The Coefficient of Variation across the patients was 48%. We found that the maximum esophagus dose was up to 2.7 times greater than the minimum. We finally observed linear relationship (Dose = 0.0218 × BMI – 0.1, R2=0.54) between patient’s BMI and the esophagus doses. Conclusion: We quantified the degree of uncertainty in the esophagus dose in five sample breast radiotherapy patients. The results of the study underscore the importance of individualized dose reconstruction for the study cohort to avoid misclassification in the risk analysis of second cancer. We are currently extending the number of patients up to 30.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases

Purpose: To validate dose calculation and delivery accuracy of a recently introduced mono-isocentric technique for the treatment of multiple brain metastases in a realistic clinical case. Methods: Anonymized CT scans of a patient were used to model a hollow phantom that duplicates anatomy of the skull. A 3D printer was used to construct the phantom of a radiologically bone-equivalent material. The hollow phantom was subsequently filled with a polymer gel 3D dosimeter which also acted as a water-equivalent material. Irradiation plan consisted of 5 targets and was identical to the one delivered to the specific patient except for the prescription dose which was optimized to match the gel dose-response characteristics. Dose delivery was performed using a single setup isocenter dynamic conformal arcs technique. Gel dose read-out was carried out by a 1.5 T MRI scanner. All steps of the corresponding patient’s treatment protocol were strictly followed providing an end-to-end quality assurance test. Pseudo-in-vivo measured 3D dose distribution and calculated one were compared in terms of spatial agreement, dose profiles, 3D gamma indices (5%/2mm, 20% dose threshold), DVHs and DVH metrics. Results: MR-identified polymerized areas and calculated high dose regions were found to agree within 1.5 mm for all targets, taking into account all sources of spatial uncertainties involved (i.e., set-up errors, MR-related geometric distortions and registration inaccuracies). Good dosimetric agreement was observed in the vast majority of the examined profiles. 3D gamma index passing rate reached 91%. DVH and corresponding metrics comparison resulted in a satisfying agreement between measured and calculated datasets within targets and selected organs-at-risk. Conclusion: A novel, pseudo-in-vivo QA test was implemented to validate spatial and dosimetric accuracy in treatment of multiple metastases. End-to-end testing demonstrated that our gel dosimetry phantom is suited for such QA procedures, allowing for 3D analysis of both targeting placement and dose.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-07: Medical Physics 1.0 Versus Medical Physics 2.0: A Case Study

Purpose: To illustrate how performance analytics can identify performance decrement in digital radiography systems. Methods: Subsequent to a radiologist’s image quality complaint, four different advanced methods contributed to root cause analysis. Our system was a GE Revolution XQi digital radiography unit. Initially, we reviewed weekly GE Quality Assurance Procedures (QAP) results in a database dating from 2001. Next, we evaluated objective image quality metrics of individual PA Chest radiographs acquired. These images were anonymized, securely transferred, and analyzed by the Duke University Clinical Imaging Physics Group with software previously described{sup 1} and validated{sup 2}. Third, we compared the exposure-dependent SNR{sup 2} (NEQ) of the unit with previously established confidence limits{sup 3}. Finally, we explored our service database to reveal events that might affect detector performance. Results: QAP reported a decrease in CNR reflected in a significant increase in lung noise(Ln), mediastinum noise(Mn), and subdiaphragm-lung contrast(Slc) with a significant decrease in lung grey level(Lgl) after detector replacement. Most change occurred during week 1, before the QAP indicated one-half the ultimate decrease in CNR. After detector recalibration, QAP CNR improved, but was not restored to previous levels. Lgl and Slc were no longer significantly different from before, however Ln and Mn remained significantly different. Exposure-dependent SNR2 show the detector to be operating within limits in October 2006 but subsequently became miscalibrated sometime before acquisition of the 2011–2014 data. Service records revealed catastrophic failure of the Image Detection Controller that contained the 2007 calibration. Traditional metrics did not indicate that the system was performing outside of normal limits. Conclusion: Performance analytics are powerful tools whose proper application could allow early intervention in degraded system performance. The image-quality metrics appear to be highly sensitive to system performance and are reported with every acquisition rather than at arbitrary intervals. Confidence intervals may require customization for individual systems or detectors.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 06: An Evaluation of Incident Reporting and Learning using the Canadian National System for Incident Reporting – Radiation Treatment

We report on the development and clinical deployment of an in-house incident reporting and learning system that implements the taxonomy of the Canadian National System for Incident Reporting – Radiation Treatment (NSIR-RT). In producing our new system, we aimed to: Analyze actual incidents, as well as potentially dangerous latent conditions. Produce recommendations on the NSIR-RT taxonomy. Incorporate features to divide reporting responsibility among clinical staff and expedite incident categorization within the NSIR-RT framework. Share anonymized incident data with the national database. Our multistep incident reporting workflow is focused around an initial report and a detailed follow-up investigation. An investigator, chosen at the time of reporting, is tasked with performing the investigation. The investigation feature is connected to our electronic medical records database to allow automatic field population and quick reference of patient and treatment information. Additional features include a robust visualization suite, as well as the ability to flag incidents for discussion at monthly Risk Management meetings and task ameliorating actions to staff. Our system was deployed into clinical use in January 2016. Over the first three months of use, 45 valid incidents were reported; 31 of which were reported as actual incidents as opposed to near-misses or reportable circumstances. However, we suspect there is ambiguity within our centre in determining the appropriate event type, which may be arising from the taxonomy itself. Preliminary trending analysis aided in revealing workflow issues pertaining to storage of treatment accessories and treatment planning delays. Extensive analysis will be undertaken as more data are accrued.

60 APPLIED LIFE SCIENCES↗

Using AI tools to analyze periodic phenomena

Here, in this report, we describe how students can use natural language to prompt ChatGPT to conduct the analysis of complex periodic acceleration data collected using their smartphones. Students may use this approach to characterize human physiological tremor frequency. Students can choose to use their own data, or, for privacy purposes, use an anonymized set of data provided to them.

Klay, Jennifer L. [California Polytechnic State Un↗

The price of privately releasing contingency tables, and the spectra of random matrices with correlated rows

Contingency tables are the method of choice of government agencies for releasing statistical summaries of categorical data. In this paper, we consider lower bounds on how much distortion (noise) is necessary in these tables to provide privacy guarantees when the data being summarized is sensitive. We extend a line of recent work on lower bounds on noise for private data analysis [10, 13. 14, 15] to a natural and important class of functionalities. Our investigation also leads to new results on the spectra of random matrices with correlated rows. Consider a database D consisting of n rows (one per individual), each row comprising d binary attributes. For any subset of T attributes of size |T| = k, the marginal table for T has 2{sup k} entries; each entry counts how many times in the database a particular setting of these attributes occurs. Imagine an agency that wishes to release all (d/k) contingency tables for a given database. For constant k, previous work showed that distortion {tilde {Omicron}}(min{l_brace}n, (n{sup 2}d){sup 1/3}, {radical}d{sup k}{r_brace}) is sufficient for satisfying differential privacy, a rigorous definition of privacy that has received extensive recent study. Our main contributions are: (1) For {epsilon}- and ({epsilon}, {delta})-differential privacy (with {epsilon} constant and {delta} = 1/poly(n)), we give a lower bound of {tilde {Omega}}(min{l_brace}{radical}n, {radical}d{sup k}{r_brace}), which is tight for n = {tilde {Omega}}(d{sup k}). Moreover, for a natural and popular class of mechanisms based on additive noise, our bound can be strengthened to {Omega}({radical}d{sup k}), which is tight for all n. Our bounds extend even to non-constant k, losing roughly a factor of {radical}2{sup k} compared to the best known upper bounds for large n. (2) We give efficient polynomial time attacks which allow an adversary to reconstruct sensitive infonnation given insufficiently perturbed contingency table releases. For constant k, we obtain a lower bound of {tilde {Omega}}(min{l_brace}{radical}n, {radical}d{sup k}{r_brace}) that applies to a large class of privacy notions, including K-anonymity (along with its variants) and differential privacy. In contrast to our bounds for differential privacy, this bound (a) is shown only for constant k, but (b) is tight for all values of n when k is constant. (3) Our reconstruction-based attacks require a new lower bound on the least singular values of random matrices with correlated rows. For a constant k, consider a matrix M with (d/k) rows which are formed by taking all possible k-way entry-wise products of an underlying set of d random vectors. We show that even for nearly square matrices with d{sup k}/log d columns, the least singular value is {Omega}({radical}d{sup k}) with high probability - asymptotically, the same bound as one gets for a matrix with independent rows. The proof requires several new ideas for analyzing random matrices and could be of independent interest.

97 MATHEMATICS AND COMPUTING↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tomopy: A Python toolbox to perform X-Ray data proessing and image reconstruction.

Tomopy is a Python toolbox to perform x-ray data processing, image reconstruction and data exchange tasks at synchrotron facilities. The dependencies of the software are currently as follows: -Python related python standard library (http://docs.python.org/2/library/) numpy (http://www.numpy.org/) scipy (http://scipy.org/) matplotlib (http://matplotlip.org/) sphinx (http://sphinx-doc.org) pil (http://www.pythonware.com/products/pil/) pyhdf (http://pysclint.sourceforge.net/pyhdf/) h5py (http://www.h5py.org) pywt (http://www.pybytes.com/pywavelets/) file.py (https://pyspec.svn.sourceforge.net/svnroot/pyspec/trunk/pyspec/ccd/files.py) -C/C++ related: gridec (anonymous?? C-code written back in 1997 that uses standard C library) fftw (http://www.fftw.org/) tomoRecon (multi-threaded C++ verion of gridrec. Author: Mark Rivers from APS. http://cars9.uchicago.edu/software/epics/tomoRecon.html) epics (http://www.aps.anl.gov/epics/)

Source record↗

Concurrent Relaxation through Accelerated Deep Learning

CRADL captures performance metrics of machine learning algorithms operating on mesh data from multiphysics codes This proxy application is a tool to explore scalability of inference on HPC platforms, and also gather performance metrics for inference on new machine learning specific hardware. CRADL is designed to give users as fine a control as possible over an inference simulation. Users may select the number of cycles, amount of data, and batch size to pass to the accelerator of choice. Additionally the user may select a number of performance optimization libraries and flags. CRADL comes packaged with a repository of anonymized multi-physics simulation data, as well as a pretrained model for inference. The code allows a user to load their own pre-trained model and data if they wish. The code can operate in multiple parallelization schemes, with performance enhancing options such as half-precision libraries, PyTorch benchmarking, and pinned memory with non-blocking data transfers.

Zieb, KristoferJ.↗

Location Generalizer

This software produces general location descriptions from time-series location data collected from mobile devices that record global positioning system (GPS) coordinates over time. The purpose of this software is to convert detailed location history data, which is considered personally identifiable information (PII), into non-traceable, anonymized, generic information that is useful to researchers but does not contain PII. The software is specifically designed for use with trigger-based data that describe the parked locations and dwell times of automobiles.

Smart, John↗

Building Performance Database API (BPD API) v2.1

The Building Performance Database (BPD) is the largest publicly-available source of measured energy performance data for buildings in the United States. It contains information about the building's energy use, location, and physical and operational characteristics. The BPD can be used by building owners, operators, architects and engineers to compare a building's energy efficiency against customized peer groups, identify energy efficiency opportunities, and set energy efficiency targets. It can also be used by energy efficiency program implementers and policymakers to analyze energy efficiency features and trends in the building stock. The BPD compiles data from various data sources, converts it into a standard format, cleanses and quality checks the data, and provides users with access to the data in a way that maintains anonymity for data providers. This software is the database and the Application Programming Interface (API). Users can utilize the BPD's data to develop their own applications using the API. Version 2.1 included a major update for multiple years of data and refactoring of code for faster queries.

Mathew, Paul↗

Survey Administration Tool

This software allows a student/user at some point during the flow of content on a web page to input comments and rate the content with things such as: 1) True false 2) Text Comments 3) Ratings 1-5 4) etc. This information is stored anonymously in the database and can be retrieved and reported on.

Sharp, Jesse↗

EyeON

EyeON: Eye on Operational technology Software Supply Chain attacks have risen drastically over the past few years, none more well-known and impactful than the SolarWinds compromise. Criminal organizations inserted an attack vector into a specific version of the source code, giving themselves an air of credibility. Once news broke on SolarWinds, identifying compromised sites was very difficult, even knowing the culprit update. Software Bills of Materials (SBOM) have been touted as the solution to reclaiming control of your software supply chain. Deployment of SBOMs has been slow, however, due to conflicting standards, opaque storage requirements, and vendor adoption. Additionally, the path from obtaining an SBOM and securing your supply chain is unclear; how can an SBOM library be leveraged to provide insight to your attack surface? The EyeON tool, sponsored by Department of Energy Cybersecurity, Energy Security, and Emergency Response (DoE CESER), aims to address these gaps by providing an encapsulated solution to tracking which updates have been installed in an enterprise, and alerting system administrators to vulnerabilities as they become known. Similar to a virus scanner, EyeON is a command line tool to parse either a single file, nested directory structure, or filesystem. It collects data such as signature (hashes), version information, VirusTotal tags, compiler, compilation date, and code signing information. Users will anonymously submit scan data periodically to DoE CESER, who will then compile a database of known software products employed by Critical Infrastructure and broadcast alerts based on discovered flaws as they arise.

Tenzing, Wangmo↗

Differentially Private Adaptive Noise Injection (DP-ANI) v1.0

Location data is collected from users continuously to understand their mobility patterns. Releasing the user trajectories may compromise user privacy. Therefore, the general practice is to release aggregated location datasets. However, private information may still be inferred from an aggregated version of location trajectories. Differential privacy (DP) protects the query output against inference attacks regardless of background knowledge. This software implements a differential privacy-based privacy model that protects the user's origins and destinations from being inferred from aggregated mobility datasets. This is achieved by injecting Planar Laplace noise to the user origin and destination GPS points. The noisy GPS points are then transformed into a link representation using a link-matching algorithm. Finally, the link trajectories form an aggregated mobility network. The injected noise level is selected using the Sparse Vector Mechanism. This DP selection mechanism considers the link density of the location and the functional category of the localized links. Compared to the different baseline models, including a k-anonymity method, our differential privacy-based aggregation model offers query responses that are close to the raw data in terms of aggregate statistics at both the network and trajectory-levels with maximum 9% deviation from the baseline in terms of network length.

Peisert, Sean [Lawrence Berkeley National Laborato↗

REDI – Readiness Engine for Data Integration

The Readiness Engine for Data Integration (REDI) is an open-source framework for automating, standardizing, and assessing the process of preparing scientific data for AI training. REDI implements a five-stage pipeline (ingest, preprocess, transform, structure, output) with per-stage provenance instrumentation via Flowcept, domain-aware transformation logic (PII anonymization, regridding, graph encoding, and more), and built-in readiness assessment and validation modes. REDI has been evaluated across climate, proteomics, materials science, and nuclear fusion datasets, demonstrating near-ideal parallel scaling to 100 nodes on OLCF's Frontier system. REDI is deployable as an agent-callable skill in coding environments such as Claude Code and OpenAI Codex, and is complemented by SetGo for FAIR compliance and catalog publication.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗