Search NASA⌕ Search

SEARCH · Search NASA

Results for “Apparent consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

132 records · Page 8

Fluidized-Bed Gasification of Coal-Biomass-Plastics for Hydrogen Production

Coal is one of the most abundant fossil energy resources in the United States and in the world. The recoverable reserves in the United States are estimated to be about 252 billion tons – more than 350 years of supply at current rates of usage. However, the share of coal in total primary energy consumption in the US has been declining over the years. The decline of coal is mainly attributed to cheap natural gas and precipitous declines in the cost of electricity production from renewable technologies such as wind and solar. Coal can potentially be used if it is coupled with carbon-neutral feedstock such as biomass-agricultural residues, forest biomass, and forest residues. Co-gasification of coal and biomass can become a negative carbon emission technology if the carbon dioxide (CO 2 ) is captured and sequestered. Although the biomass gasification process has a lot of similarities to coal gasification, the large-scale adaptation of power production sourced from biomass has not come to fruition. The main reason is that the power production from biomass is still expensive when compared with natural gas or coal power technologies. To address the feedstock cost, one approach is to use low-cost feedstocks, such as municipal solid wastes (MSW) or plastics, for gasification. Gasification involves the partial oxidation of coal and/or biomass feedstocks to produce a combustible fuel called synthesis gas (syngas) which is composed of carbon monoxide (CO), hydrogen (H 2 ), CO 2 , methane (CH 4 ), nitrogen (N 2 ), water (H 2 O), and other compounds that might be considered as contaminants. Raw syngas from gasification must go through multiple steps to produce high-purity hydrogen. The specific steps depend upon the quality (gas composition, contaminants, and their concentration) and condition (pressure and temperature) of syngas. The long-term goal of the project was to utilize coal and plastics together with biomass to produce energy and fuels using a gasification platform while reducing greenhouse gas emissions. The main objective of this research was to examine gasification performance in a laboratory-scale fluidized-bed gasifier for hydrogen production. The specific objectives of the research were to: (i) study coal-plastic-biomass mixture flowability for consistent feeding in the gasifier; (ii) understand the gasification behavior of the mixture in steam and oxygen environments; (iii) perform thermal property characterization of ash and slag from the mixture feedstock and refractory-ash interface of the mixture under gasification conditions; and (iv) develop process models to determine the technology needed for syngas cleanup and contaminants. The study found that there was no apparent segregation when biomass, coal, and waste plastics were mixed together during feeding. Although there were differences in hydrogen production when individual feedstock were fed, the hydrogen concentration remained almost constant with various blends. Therefore, blending waste plastics with biomass and coal, which are all abundant, is a better approach for energy production. Results of the techno-economic analysis suggested that integration of advanced gasification (GTI’s R-GAS™) and syngas cleanup and conditioning technologies (RTI’s WDP and AFWGS) for clean hydrogen production resulted in substantial benefits, including significant capital cost and operating cost reductions. Advanced technologies resulted in 16% reduction in the hydrogen production cost (COH) from 2.94 $\$$/kg to 2.47 $\$$/g, with further scope for optimization and cost reduction. These advanced technologies also result in lower emissions, and improved energy efficiency.

01 COAL, LIGNITE, AND PEAT↗

Zeta potential measurements of SiO 2 and TiO 2 particles in anionic and cationic surfactant solutions

Zeta potential measurements can provide valuable insights into colloidal stability and may reflect changes in the electrochemical double layer that influence electrocatalysis. In this study, we used zeta potential measurements to monitor and investigate the adsorption behavior of anionic sodium dodecyl sulfate (SDS), cationic dodecyl trimethyl ammonium bromide (DTAB), and cationic cetyl trimethyl ammonium bromide (CTAB) surfactants on SiO 2 and TiO 2 particles in DI water. The zeta potentials of SiO 2 and TiO 2 particles were measured as a function of particle concentration in 1.0 mM, 5.0 mM, and 10.0 mM surfactant solutions. Results indicate that there is no significant adsorption of DS - ions on SiO 2 particles across all SDS concentrations investigated in this study. The zeta potential of TiO 2 particles shifts from negative to positive as particle concentration increases at 1.0 mM SDS, indicating a decrease in DS - ions adsorption per TiO 2 particle. Adsorption plateaus at 5.0 mM SDS for all TiO 2 concentrations studied. In contrast, DTA + and CTA + ions showed clear adsorption on SiO 2 particles, but DTA + exhibited no apparent adsorption on TiO 2 particles. Interestingly, CTA + adsorption on TiO 2 was only evident at higher surfactant concentrations. This study presents a systematic investigation of zeta potential behavior as a function of particle and surfactant concentration, highlighting adsorption saturation and electrostatic reversal. Unlike prior work that was limited to single particle concentration measurements, our approach reveals how surfactant adsorption per particle decreases with increasing surface area. Despite the structural similarity between DTAB and CTAB, this study captured the different adsorption behaviors of both surfactants on SiO 2 and TiO 2 , emphasizing the role of the overall structure of the surfactant on surfactant adsorption behavior. These insights refine the interpretation of zeta potential data and advance understanding of surfactant adsorption on oxide particles. The insight provided in this study about surfactant adsorption on SiO 2 and TiO 2 particles could have important implications for the design of more effective colloidal and catalytic systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Differences in Phase 1 and Phase 2 Test Observations for Waste Treatment Plant Pulse Jet Mixer Tests with Non-Cohesive Solids

The purpose of this work was to assess the apparent discrepancy in critical suspension velocity (UCS) between M3 Phase 1 (Meyer et al. 2009) and Phase 2 testing conducted by Energy Solutions (ES) at Mid-Columbia Engineering (MCE) and to address the applicability of Phase 1 scale-up laws to Phase 2 test results. Three Phase 2 test sequences were analyzed in detail. Several sources of discrepancy were identified including differences in nominal versus actual velocity, definition of model input parameters, and definition of UCS. A remaining discrepancy was shown to not be solely an artifact of Phase 1 data correlations, but was fundamental to the tests. The non-prototypic aspects of Phase 1 testing were reviewed and assessed. The effects of non-prototypic refill associated with the closed loop operation of the jets, previously known to affect cloud height, can be described in terms of a modified settling velocity. When the modified settling velocity is incorporated into the Phase 1 “new” physical model the adjusted new physical model does a better job of predicting the Phase 2 test results. The adjusted new physical model was bench marked with data taken during three prototypic drive tests. Scale-up behavior of the Phase 1 tests was reviewed. The applicability of the Phase 1 scale-up behavior to Phase 2 prototypic testing was analyzed. The effects of non-prototypic refill caused measured values of UCS to be somewhat reduced at larger scales. Hence the scale-up exponents are believed to be smaller than they would have been had there been prototypic refill. Estimated scale-up exponents for the Phase 2 testing are 0.40 for 8-tube tests and 0.36 for 12-tube tests.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Integration of the Mini-Sulfide Sulfite Anthraquinone (MSS-AQ) Pulping Process and Black Liquor Gasification in a Pulp Mill

As many of the recovery boilers and other pieces of large capital equipment of U.S. pulp mills are nearing the end of their useful life, the pulp and paper industry will soon need to make long-term investments in new technologies. The ability to install integrated, complete systems that are highly efficient will impact the industry’s energy use for decades to come. Developing a process for these new systems is key to the adoption of state-of-the-art technologies in the Forest Products industry. This project defined an integrated process model that combines mini-sulfide sulfite anthraquinone (MSS-AQ) pulping and black liquor gasification with a proprietary desulfurization process developed by the Research Triangle Institute. Black liquor gasification is an emerging technology that enables the use of MSS-AQ pulping, which results in higher yield, lower bleaching cost, lower sulfur emissions, and the elimination of causticization requirements. The recently developed gas cleanup/absorber technology can clean the product gas to a state suitable for use in a gas turbine and also regenerate the pulping chemicals needed to for the MSS-AQ pulping process. The combination of three advanced technologies into an integrated design will enable the pulping industry to achieve a new level of efficiency, environmental performance, and cost savings. Because the three technologies are complimentary, their adoption as a streamlined package will ensure their ability to deliver maximum energy and cost savings benefits. The process models developed by this project will enable the successful integration of new technologies into the next generation of chemical pulping mills. When compared to the Kraft reference pulp, the MSS-AQ procedures produced pulps with a 10-15 % yield benefit and the ISO brightness was 1.5-2 times greater. The pulp refined little easier and had a slightly lower apparent sheet density (In both the cases). At similar levels of tear index the MSS-AQ pulps also produced a comparable tensile and burst index pulps. Product gas composition determined using computer simulations The results demonstrate that RVS-1 can effectively remove > 99.8% of the H2S present in simulated synthesis gas generated from the gasification of black liquor. This level of sulfur removal was consistent over simulated synthesis gas mixtures that contained from 6 to 9.5 vol % H2S.A significant amount of the sulfur in the simulated syngas was recovered as SO2 during regeneration. The average recovery of sulfur as SO2 was about 75%. Because these are first cycle results, this sulfur recovery is expected to improve. Developed WINGems model of the process.The total decrease in variable operating costs for the BLG process compared to the HERB was in excess of $6,200,000 per year for a mill producing 350,000 tons of pulp per year. This represents a decrease in operating cost of about $17.7/ton of oven dry pulp produced. There will be additional savings in labor and maintenance cost that has not been taken into account. The capital cost for the MSSAQ based gasifier system was estimated at $164,000,000, which is comparable to a High Efficiency Recovery Boiler. The return on investment was estimated at 4%. A gasifier replacement cannot be justified on its own, however if the recovery boiler needs to be replaced the MSSAQ gasifier system shows significantly higher savings. Before black liquor based gasifer technology can be commercialized more work is necessary. The recovery of the absorbed sulfur in the absorbent as sulfur dioxide is only 75%. This needs to be greater than 90% for economical operation. It has been suggested that as the number of cycles is increased the sulfur dioxide recovery might improve. Further research is necessary. Even though a significant amount of work has been done on a pilot scale gasifiers using liquors containing sulfur, both at low and high temperatures the lack of a commercial unit is an impediment to the implementation of the MSSAQ technology. The implementation of a commercial unit needs to be facilated before the benefits of the MSSAQ technology with ZnO absorbtion will become acceptable to the paper industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗