Search NASA⌕ Search

SEARCH · Search NASA

Results for “Assay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Predicting the sensitivity and specificity of published real-time PCR assays

Background: In recent years real-time PCR has become a leading technique for nucleic acid detection and quantification. These assays have the potential to greatly enhance efficiency in the clinical laboratory. Choice of primer and probe sequences is critical for accurate diagnosis in the clinic, yet current primer/probe signature design strategies are limited, and signature evaluation methods are lacking. Methods: We assessed the quality of a signature by predicting the number of true positive, false positive and false negative hits against all available public sequence data. We found real-time PCR signatures described in recent literature and used a BLAST search based approach to collect all hits to the primer-probe combinations that should be amplified by real-time PCR chemistry. We then compared our hits with the sequences in the NCBI taxonomy tree that the signature was designed to detect. Results: We found that many published signatures have high specificity (almost no false positives) but low sensitivity (high false negative rate). Where high sensitivity is needed, we offer a revised methodology for signature design which may designate that multiple signatures are required to detect all sequenced strains. We use this methodology to produce new signatures that are predicted to have higher sensitivity and specificity. Conclusion: We show that current methods for real-time PCR assay design have unacceptably low sensitivities for most clinical applications. Additionally, as new sequence data becomes available, old assays must be reassessed and redesigned. A standard protocol for both generating and assessing the quality of these assays is therefore of great value. Real-time PCR has the capacity to greatly improve clinical diagnostics. The improved assay design and evaluation methods presented herein will expedite adoption of this technique in the clinical lab.

59 BASIC BIOLOGICAL SCIENCES↗

Biomarkers, Proteoforms, and Mass Spectrometry–Based Assays for Diabetes Clinical Research

Abstract The prevalence of diabetes, particularly type 2 diabetes, has reached epidemic proportions globally. The number of patients with type 1 diabetes (T1D) is also increasing rapidly. Despite advancements in understanding the pathogenesis of diabetes, the lack of circulating pancreatic biomarkers and reliable clinical-grade assays remains a major gap in diabetes research, often hindering the ability to adequately assess disease progression and therapeutic responses. This mini-review discusses emerging pancreatic biomarkers, with an emphasis on T1D, the limitations of current immunoassays, and the expanding role of mass spectrometry–based assays. Highlights include the recent work within the NIDDK-funded “Targeted Mass Spectrometry Assays for Diabetes and Obesity Research (TaMADOR)” consortium, which aims to develop robust, quantitative, and transferable assays for translational research. The review also emphasizes the importance of proteoform-specific assays for monitoring pancreatic function, including prohormone processing during disease progression or in responses to therapy.

Endocrinology & Metabolism↗

Membrane insertion for the detection of lipopolysaccharides: Exploring the dynamics of amphiphile-in-lipid assays

Shiga toxin-producing Escherichia coli is an important cause of foodborne illness, with cases attributable to beef, fresh produce and other sources. Many serotypes of the pathogen cause disease, and differentiating one serotype from another requires specific identification of the O antigen located on the lipopolysaccharide (LPS) molecule. The amphiphilic structure of LPS poses a challenge when using classical detection methods, which do not take into account its lipoglycan biochemistry. Typically, detection of LPS requires heat or chemical treatment of samples and relies on bioactivity assays for the conserved lipid A portion of the molecule. Our goal was to develop assays to facilitate the direct and discriminative detection of the entire LPS molecule and its O antigen in complex matrices using minimal sample processing. To perform serogroup identification of LPS, we used a method called membrane insertion on a waveguide biosensor, and tested three serogroups of LPS. The membrane insertion technique allows for the hydrophobic association of LPS with a lipid bilayer, where the exposed O antigen can be targeted for specific detection. Samples of beef lysate were spiked with LPS to perform O antigen specific detection of LPS from E. coli O157. To validate assay performance, we evaluated the biophysical interactions of LPS with lipid bilayers both in- and outside of a flow cell using fluorescence microscopy and fluorescently doped lipids. Our results indicate that membrane insertion allows for the qualitative and reliable identification of amphiphilic LPS in complex samples like beef homogenates. In addition, we also demonstrated that LPS-induced hole formation does not occur under the conditions of the membrane insertion assays. Together, these findings describe for the first time the serogroup-specific detection of amphiphilic LPS in complex samples using a membrane insertion assay, and highlight the importance of LPS molecular conformations in detection architectures.

59 BASIC BIOLOGICAL SCIENCES↗

Lead Slowing-Down Spectrometry for Spent Fuel Assay: FY11 Status Report

Executive Summary Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. This document is a progress report for FY2011 collaboration activities. Progress made by the collaboration in FY2011 continues to indicate the promise of LSDS techniques applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model demonstrated the potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space. Similar results were obtained using a perturbation approach developed by LANL. Benchmark measurements have been successfully conducted at LANL and at RPI using their respective LSDS instruments. The ISU and UNLV collaborative effort is focused on the fabrication and testing of prototype fission chambers lined with ultra-depleted 238U and 232Th, and uranium deposition on a stainless steel disc using spiked U3O8 from room temperature ionic liquid was successful, with improving thickness obtained. In FY2012, the collaboration plans a broad array of activities. PNNL will focus on optimizing its empirical model and minimizing its reliance on calibration data, as well continuing efforts on developing an analytical model. Additional measurements are planned at LANL and RPI. LANL measurements will include a Pu sample, which is expected to provide more counts at longer slowing-down times to help identify discrepancies between experimental data and MCNPX simulations. RPI measurements will include the assay of an entire fresh fuel assembly for the study of self-shielding effects as well as the ability to detect diversion by detecting a missing fuel pin in the fuel assembly. The development of threshold neutron sensors will continue, and UNLV will calibrate existing ultra-depleted uranium deposits at ISU.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Targeted Sequencing Assay for Serotyping Escherichia coli Using AgriSeq Technology

The gold standard method for serotyping Escherichia coli has relied on antisera-based typing of the O- and H-antigens, which is labor intensive and often unreliable. In the post-genomic era, sequence-based assays are potentially faster to provide results, could combine O-serogrouping and H-typing in a single test, and could simultaneously screen for the presence of other genetic markers of interest such as virulence factors. Whole genome sequencing is one approach; however, this method has limited multiplexing capabilities, and only a small fraction of the sequence is informative for subtyping or identifying virulence potential. A targeted, sequence-based assay and accompanying software for data analysis would be a great improvement over the currently available methods for serotyping. The purpose of this study was to develop a high-throughput, molecular method for serotyping E. coli by sequencing the genes that are required for production of O- and H-antigens, as well as to develop software for data analysis and serotype identification. To expand the utility of the assay, targets for the virulence factors, Shiga toxins ( stx 1 , and stx 2 ) and intimin ( eae ) were included. To validate the assay, genomic DNA was extracted from O-serogroup and H-type standard strains and from Shiga toxin-producing E. coli , the targeted regions were amplified, and then sequencing libraries were prepared from the amplified products followed by sequencing of the libraries on the Ion S5™ sequencer. The resulting sequence files were analyzed via the SeroType Caller™ software for identification of O-serogroup, H-type, and presence of stx 1 , stx 2 , and eae . We successfully identified 169 O-serogroups and 41 H-types. The assay also routinely detected the presence of stx 1a,c,d (3 of 3 strains), stx 2c−e,g (8 of 8 strains), stx 2f (1 strain), and eae (6 of 6 strains). Taken together, the high-throughput, sequence-based method presented here is a reliable alternative to antisera-based serotyping methods for E. coli .

Elder, Jacob R.↗

Developing A Miniaturized Biology Assay for the Astrobiology Search Kit

Partnering with Retego Labs we will develop an acetate assay to use in the Astrobiology Search Kit advanced spectrometer. Our current knowledge of metabolic pathways (methanogeneis, and acetogenesis) both produce acetate. There is no known method of producing acetate abiotically, therefore the detection of acetate indicates the presence of biology. There is no current assays to directly detect acetate. We would be developing the first assay. Our development plan is based on the development of previous assays. We start with EPA standards then modify and increase the sensitivity based on our detection needs. In this case the detection is 10^2 cells/ml equivalent. This assay would be useful on Titan where if life exists the biogeochemistry is methane based instead of water based like Earth (possibly Mars, Europa).

H. Smith↗

Multiplexed lateral flow microarray assay for detection of citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis pv citri

The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.

59 BASIC BIOLOGICAL SCIENCES↗

The Role of Piece Monitors for the Assay of Plutonium Waste in Alpha Plant Decommissioning Operations

Plutonium contaminated (TRU) wastes arising during decommissioning and waste retrievals operations at a UK reprocessing facility include small process items, strippable coatings, size-reduced pieces of glove box and metal pipes, etc. These waste materials are generally assayed in a 'Piece Monitor' employing neutron coincidence counting and gamma assay technologies. The major function of the TRU D{sup R} Piece Monitor is to provide an accurate assay of the TRU content of waste pieces/packages, primarily for nuclear safety purposes. The Piece Monitor follows each waste measurement by calculating the cumulative plutonium content of a waste drum as it is filled with this waste, allowing maximum filling of the drum whilst ensuring it remains within fissile content limits. TRU Piece Monitors are deployed at the interface between clean-air (C2) and the active decommissioning (C5) areas by attaching them to the wall of removable modular containment structures (MCSs). In the C5 area, the plant operator uses a variety of cold-cutting processes to size-reduce plant equipment and then places waste items in the monitor chamber for assay, prior to placing the waste in a 200 litre drum. The 're-entrant bulge' design of the assay chamber provides access from the active operations side, whilst the detection equipment remains in the C2 area. This ensures that the Piece Monitor equipment does not become contaminated and remains readily accessible for maintenance or repair. Piece monitors measure and report the plutonium content of each waste item immediately prior to placing in the waste drum, and provides a continuous 'tally' of the drum content. Warnings are shown when a drum is close to exceeding its allowable plutonium content and the waste drum can therefore be changed when either physically full or nearing its nuclear safety limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Approach in Fissile Assay Using LSDS - 17076

A quantitative assay of isotopic fissile materials (U{sup 235}, Pu{sup 239}, Pu{sup 241}) was conducted at the Korea Atomic Energy Research Institute (KAERI), using a lead slowing down spectrometer (LSDS). Using a uranium rod and plutonium, the actual measurement of induced fission neutrons was performed in the RPI (Rensselaer Polytechnic Institute) LSDS facility. In the simulation, a content of U{sup 235}, Pu{sup 239}, and Pu{sup 241} was changed. The detected signal has a direct relationship with the mass of the existing fissile isotopes. The mathematical model for fissile assay was applied to the measured and simulated detection data. The assay results show that the isotopic content was consistent with 2 to 3% uncertainty for Pu{sup 239}. The simulation indicated that the assay result was affected by the self-shielding correction. Usually, in highly enriched plutonium, the correction plays an important role and good understanding of it is required in order to increase assay accuracy. The combination of LSDS technique measurement and simulation is a very powerful and direct way to analyze the isotopic fissile content. The information provided by such analysis is applicable to nuclear fuel cycle development and spent fuel management for safety and economics. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ Gamma-Ray Assay of the 235-F Plutonium Fuel Form Facility at the Savannah River Site - 16293

The Plutonium Fuel Form (PuFF) Facility is located in Building 235-F near the geographic center of the Savannah River Site. Between 1978 and 1984, the facility was used to produce approximately 165 kilograms of iridium-encapsulated Pu-238 spheres and pellets for use as radioisotope thermal generators, primarily for the space program. The facility is divided between two cell lines, the east cell line used to process powdered Pu-238 oxide raw material into fuel forms and the west cell line used to encapsulate the fuel forms in iridium. Scoping in-situ gamma-ray assays were performed in the PuFF Facility in 2006 and estimated that hundreds of grams of Pu-238 holdup were within the facility. Using this holdup estimate as a source term, SRS has performed a risk analysis that indicated a seismic event that induces a full-facility fire in 235-F could lead to a 28,800 rem dose to a co-located worker. Based on this risk assessment, SRS is taking steps to decontaminate the facility. One of the first steps taken has been to improve upon the quality of the in-situ gamma-ray assay data. Carts and collimators were specially designed to survey the equipment in the PuFF Facility. The cell interiors were assayed along with the furnaces and storage coolers that protrude beneath the cells. While the previous scoping work consisted of 32 measurements, the current series of measurements included nearly 400 measurements using both high-purity germanium and lanthanum bromide detectors. Data analysis for the current set of measurements was conducted with greater rigor as well. MCNP5 was used to evaluate a variety of possible physical distributions for the Pu-238 source term and estimate cross-talk between neighboring cells. Data analysis was performed using three gamma-rays emitted by Pu-238 (99.85 keV, 152.7 keV, and 766.4 keV) providing three independent estimates of the mass of Pu-238 holdup in each of the cells. This also allowed the application of matrix correction factors to adjust gamma-ray attenuation. The weighted mean of these three results was used as the best estimate of Pu-238 holdup in the PuFF facility. This work lowered the estimate of holdup in the PuFF facility by approximately 100 grams compared to the previous estimate, a 0.55's difference. The uncertainty in the Pu-238 holdup was also reduced substantially relative to the 2006 scoping assay. Further radiological measurements are planned for the near future including in-situ gamma-ray assays of wing cabinets in the east cell line maintenance area, the transfer tube between the two cell lines, and some of the furnaces and storage coolers. A germanium gamma imager, the GeGI, will also be used to map out the distribution of the Pu-238 source term in the PuFF Facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE)

Uranium hexafluoride (UF6) is the uranium compound typically involved in uranium enrichment process. As the first line of defense against nuclear proliferation, accurate determinations of the uranium enrichment ratio in UF6 are critical for materials verification, accounting and safeguards. Shipping gaseous UF6 samples off-site for analysis with mass spectrometry is cumbersome and costly, and results are not available for some time (months). In-field UF6 enrichment assay has the potential to substantially reduce the time, logistics and expense of sample handling. At present, COMPUCEA is the only accepted method for UF6 enrichment assay in the field. Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE) is an all-optical (based on laser induced plasma emission) analytical technique intended for fieldable, accurate, precise and rapid UF6 enrichment assay. In its operation, laser induced plasma is created directly in the gaseous UF6 sample. Because different U isotopes emit at slightly different wavelengths, the isotopic information of the UF6 sample is inherently encoded in the atomic emission from the plasma. Isotopic emissions from 235U and 238U are measured simultaneously, which eliminate correlated noise from the laser induced plasma. Isotopic information of the UF6 sample can be extracted from the acquired spectrum with theoretical multi-variable non-linear spectral fitting. To date, advances made by the LISA-UE research team include optimization of the spectral window for direct gaseous UF6 enrichment assay with laser induced plasma, development of data reduction algorithms, and demonstrations of the LISA-UE technique with gaseous UF6 samples. In this presentation, the technical aspect of LISA-UE will be overviewed, the data reduction algorithm will be described, and performance of the technique will be discussed.

Chan, George↗

A nanostructure-initiator mass spectrometry-based enzyme activity assay

We describe a Nanostructure-Initiator Mass Spectrometry (NIMS) enzymatic (Nimzyme) assay in which enzyme substrates are immobilized on the mass spectrometry surface by using fluorous-phase interactions. This 'soft' immobilization allows efficient desorption/ionization while also enabling the use of surface-washing steps to reduce signal suppression from complex biological samples, which results from the preferential retention of the tagged products and reactants. The Nimzyme assay is sensitive to subpicogram levels of enzyme, detects both addition and cleavage reactions (sialyltransferase and galactosidase), is applicable over a wide range of pHs and temperatures, and can measure activity directly from crude cell lysates. The ability of the Nimzyme assay to analyze complex mixtures is illustrated by identifying and directly characterizing {beta}-1,4-galactosidase activity from a thermophilic microbial community lysate. The optimal enzyme temperature and pH were found to be 65 C and 5.5, respectively, and the activity was inhibited by both phenylethyl-{beta}-d-thiogalactopyranoside and deoxygalactonojirimycin. Metagenomic analysis of the community suggests that the activity is from an uncultured, unsequenced {gamma}-proteobacterium. In general, this assay provides an efficient method for detection and characterization of enzymatic activities in complex biological mixtures prior to sequencing or cloning efforts. More generally, this approach may have important applications for screening both enzymatic and inhibitor libraries, constructing and screening glycan microarrays, and complementing fluorous-phase organic synthesis. The interest in leveraging mass spectrometry for studying enzyme activities in complex biological samples derives from its high sensitivity and specificity; however, signal suppression and significant sample preparation requirements limit its overall utility (1). Here we describe a Nanostructure-Initiator Mass Spectrometry (NIMS) enzymatic (Nimzyme) assay, which uses the fluorous liquid-coated surface of NIMS (2) to noncovalently attach enzyme substrates by means of fluorous tags. Enzymes play essential roles in a wide range of cellular processes and account for >20% of all drug targets (3). In addition, enzymes have found great utility in organic synthesis because they can efficiently catalyze chemical transformations that are difficult and inefficient to catalyze using conventional synthetic approaches. Furthermore, enzymatic transformations are particularly useful in reactions requiring multiple functional groups or stereo/regiochemically defined products (4). These properties make them particularly well suited for the synthesis and degradation of carbohydrates (5). Indeed, enzymatic approaches have found widespread applications in glycobiology (6, 7) and are of intense interest for the utilization of plant biomass for biofuels (8).

59 BASIC BIOLOGICAL SCIENCES↗

Signatures and Methods for the Automated Nondestructive Assay of UF6 Cylinders at Uranium Enrichment Plants

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility’s entire cylinder inventory. These measurements are time-consuming, expensive, and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of manpower and assay accuracy. Such a station would use sensors that can be operated in an unattended mode at an industrial facility: medium-resolution scintillators for gamma-ray spectroscopy (e.g., NaI(Tl)) and moderated He-3 neutron detectors. This sensor combination allows the exploitation of additional, more-penetrating signatures beyond the traditional 185-keV emission from U-235: neutrons produced from F-19(α,n) reactions (spawned primarily from U 234 alpha emission) and high-energy gamma rays (extending up to 8 MeV) induced by neutrons interacting in the steel cylinder. This paper describes a study of these non-traditional signatures for the purposes of cylinder enrichment verification. The signatures and the radiation sensors designed to collect them are described, as are proof-of-principle cylinder measurements and analyses. Key sources of systematic uncertainty in the non-traditional signatures are discussed, and the potential benefits of utilizing these non-traditional signatures, in concert with an automated form of the traditional 185-keV-based assay, are discussed.

36 MATERIALS SCIENCE↗

A cost-effective colorimetric assay for phenolic O-methyltransferases and characterization of caffeate 3-O-methyltranferases from Populus trichocarpa

S-Adenosyl-L-methionine (AdoMet)-dependent O-methyltransferases (OMTs) catalyze the transmethylation of a variety of phenolics in bacteria, plants, and humans. To rapidly characterize phenolic OMT activities, we adapted Gibbs reagent, the dye originally used for detecting phenols, to develop a convenient assay method for measuring the catalytic properties of enzymatic transmethylation of phenolics. We demonstrated that Gibbs reagent reacted with phenolics yielding distinct absorptive characters that we used to further develop the assay to monitor the reactivities of phenolic OMTs. To validate the method, we identified two caffeate/5-hydroxyferulate 3/5-O-methyltransferases (COMTs) from the black cottonwood, Populus trichocarpa. Together with a few other plant type I OMTs, we demonstrated that our Gibbs reagent-mediated colorimetric assay could reliably determine the functions and kinetic parameters of phenolic OMTs. Because Gibbs reagent reacting with different regioselectively modified phenolics displays different colorimetric properties, the assay method can be used to monitor both substrate specificity and the regioselectivity of phenolic OMTs.

59 BASIC BIOLOGICAL SCIENCES↗

Towards replacement of animal tests with in vitro assays: a gene expression biomarker predicts in vitro and in vivo estrogen receptor activity

High-throughput transcriptomics (HTTr) has the potential to support efforts to reduce or replace some animal tests. In past studies, we described a computational approach utilizing a gene expression biomarker consisting of 46 genes to predict estrogen receptor (ER) activity after chemical exposure in ER-positive human breast cancer cells including the MCF-7 cell line. We hypothesized that the biomarker model could identify ER activities of chemicals examined by Endocrine Disruptor Screening Program (EDSP) Tier 1 screening assays in which transcript profiles of the same chemicals were examined in MCF-7 cells. For the 62 chemicals examined including 5 chemicals examined in this study using RNA-Seq, the ER biomarker model accuracy was 1) 97% for in vitro reference chemicals, 2) 76–85% for guideline uterotrophic assays, and 3) 87–88% for guideline and nonguideline uterotrophic assays. For the same chemicals, these accuracies were similar or slightly better than those of the ToxCast ER model based on 18 in vitro assays. The performance of the ER biomarker model indicates that HTTr interpreted using the ER biomarker correctly identifies active and inactive ER reference chemicals. Finally, as part of the HTTr screening program the approach could rapidly identify chemicals with potential ER bioactivities for additional screening and testing.

60 APPLIED LIFE SCIENCES↗

Assaying Used Nuclear Fuel Assemblies Using Lead Slowing-Down Spectroscopy and Singular Value Decomposition

This study investigates the use of a Lead Slowing-Down Spectrometer (LSDS) for the direct and independent measurement of fissile isotopes in light-water nuclear reactor fuel assemblies. The current study applies MCNPX, a Monte Carlo radiation transport code, to simulate the measurement of the assay of the used nuclear fuel assemblies in the LSDS. An empirical model has been developed based on the calibration of the LSDS to responses generated from the simulated assay of six well-characterized fuel assemblies. The effects of self-shielding are taken into account by using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the self-shielding functions from the assay of assemblies in the calibration set. The performance of the empirical algorithm was tested on version 1 of the Next-Generation Safeguards Initiative (NGSI) used fuel library consisting of 64 assemblies, as well as a set of 27 diversion assemblies, both of which were developed by Los Alamos National Laboratory. The potential for direct and independent assay of the sum of the masses of Pu-239 and Pu-241 to within 2%, on average, has been demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and validation of a next-generation sequencing-based multigene assay to predict the prognosis of estrogen receptor-positive, HER2-negative breast cancer

Purpose: Multigene assays provide useful prognostic information regarding hormone receptor (HR)-positive breast cancer. Next-generation sequencing (NGS)-based platforms have numerous advantages including reproducibility and adaptability in local laboratories. Here we aimed to develop and validate an NGS-based multigene assay to predict the distant recurrence risk. Experimental Design: In total, 179 genes including 30 reference genes highly correlated with the 21-gene recurrence score (RS) algorithm were selected from public databases. Targeted RNA-sequencing was performed using 250 and 93 archived breast cancer samples with a known RS in the training and verification sets, respectively, to develop the algorithm and NGS–Prognostic Score (NGS-PS). The assay was validated in 413 independent samples with long-term follow-up data on distant metastasis. Results: In the verification set, the NGS-PS and 21-gene RS displayed 91.4% concurrence (85/93 samples). In the validation cohort of 413 samples, area under the receiver operating characteristic curve plotted using NGS-PS values classified for distant recurrence was 0.76. The best NGS-PS cut-off value predicting distant metastasis was 20. Furthermore, 269 and 144 patients were classified as low- and high-risk patients in accordance with the cut-off. Five- and 10-year estimates of distant metastasis–free survival (DMFS) for low- versus high-risk groups were 97.0% versus 77.8% and 93.2% versus 64.4%, respectively. The age-related HR for distant recurrence without chemotherapy was 9.73 (95% CI, 3.59–26.40) and 3.19 (95% CI, 1.40–7.29) for patients aged ≤50 and >50 years, respectively. Conclusions: The newly developed and validated NGS-based multigene assay can predict the distant recurrence risk in ER-positive, HER2-negative breast cancer.

60 APPLIED LIFE SCIENCES↗

A novel assay to measure low-density lipoproteins binding to proteoglycans

Background: The binding of low-density lipoprotein (LDL) to proteoglycans (PGs) in the extracellular matrix (ECM) of the arterial intima is a key initial step in the development of atherosclerosis. Although many techniques have been developed to assess this binding, most of the methods are labor-intensive and technically challenging to standardize across research laboratories. Thus, sensitive, and reproducible assay to detect LDL binding to PGs is needed to screen clinical populations for atherosclerosis risk. Objectives: The aim of this study was to develop a quantitative, and reproducible assay to evaluate the affinity of LDL towards PGs and to replicate previously published results on LDL-PG binding. Methods: Immunofluorescence microscopy was performed to visualize the binding of LDL to PGs using mouse vascular smooth muscle (MOVAS) cells. An in-cell ELISA (ICE) was also developed and optimized to quantitatively measure LDL-PG binding using fixed MOVAS cells cultured in a 96-well format. Results: We used the ICE assay to show that, despite equal APOB concentrations, LDL isolated from adults with cardiovascular disease bound to PG to a greater extent than LDL isolated from adults without cardiovascular disease (p<0.05). Conclusion: We have developed an LDL-PG binding assay that is capable of detecting differences in PG binding affinities despite equal APOB concentrations. Future work will focus on candidate apolipoproteins that enhance or diminish this interaction.

59 BASIC BIOLOGICAL SCIENCES↗