Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Atomic and molecular gas in interstellar cirrus clouds

The dust, atomic gas, and molecular gas content of a sample of 26 of isolated, degree-sized infrared clouds are compared. Half of the clouds have an infrared excess indicating the presence of H2, and 14 contain compact CO-emitting regions. Complete, high angular resolution H I and CO maps of one cloud, G236+39, resolve the transition between atomic and molecular H, as well as the location of CO formation. Assuming the infrared emission traces the total column density, H2 is inferred to be much more widely distributed than the CO. The CO rotational levels are subthermally excited, and the (2 - 1)/(1 - 0) line ratios suggest a density n(H2) approximately 200/cm(exp 3) where CO was detected. A model of H2 formation on grain surfaces balanced by self-shielded photodissociation fits the variation of infrared brightness with H I column density. Assuming a temperature of 80 K, typical of diffuse H2 (Savage et al. 1977), the H2 chemistry requires an average density n(H + 2H2) approximately 50/cm(exp 3). For G236+39, if the distance is 100 pc, the H I and H2 masses are estimated to be 90 and 70 solar mass, respectively. High-resolution H I and infrared maps of a smaller cloud, G249.0+73.7, reveal no evidence for molecular gas, which is likely due to the low total column density through this cloud. These results suggest the H2 and H I content are comparable for some interstellar cirrus clouds with column densities N(H I) greater than 4 x 10(exp 20)/cm(exp 2), even where CO was not detected.

Reach, William T.↗

Studies on lasers and laser devices

The goal of this grant was to study lasers, laser devices, and uses of lasers for investigating physical phenomena are studied. The active projects included the development of a tunable, narrowband XUV light source and its application to the spectroscopy of core excited atomic states, and the development of a technique for picosecond time resolution spectroscopy of fast photophysical processes.

Harris, S. E.↗

Detection of shocked atomic gas in the Kleinmann-Low nebula

The 63 micrometer (3)p(1)-(3)P(2) fine structure line emission of neutral atomic oxygen at the center of the Orion nebula with a resolution of 30" is presented. There are three main emission peaks. One is associated with the region of strongest thermal radio continuum radiation close to the Trapezium cluster, and probably arises at the interface between the HII region and the dense Orion molecular cloud. The other two line emission peaks, associated with the Kleinmann Low nebula, are similar in both distribution and velocity to those of the 2 micrometer S(1) line of molecular hydrogen and of the high velocity wings of rotational CO emission. The OI emission from the KL nebula can be produced in the shocked gas associated with the mass outflows in this region and is an important coolant of the shocked gas.

Werner, M.↗

Non-Imaging Remote Sensing Data

Spectrometric, radiometric and polarimetric remote sensing observations of wavelengths from gamma-rays to microwaves are addressed. The basic form of the data is one dimensional arrays. At the high energy end of the spectrum, data are typically presented as pulse count versus energy, and at lower energies, as intensity versus wavelength. High spectral resolution measurements (better 1% of wavelength) are particularly useful for identifying atomic, molecular, and ionic species while broader band measurements are adequate for identifying minerals and for determining total energy fluxes. Polarization data permit the study of finely divided material such as clouds and surfaces.

Source record↗

Detection of shocked atomic gas in the Kleinmann-Low nebula

The 63 micrometer (3)P(1)-(3)P(2) fine structure line emission of neutral atomic oxygen at the center of the Orion nebula with a resolution of 30'' is presented. There are three main emission peaks. One is associated with the region of strongest thermal radio continuum radiation close to the Trapezium cluster, and probably arises at the interface between the H II region and the dense Orion molecular cloud. The other two line emission peaks, associated with the Kleinmann-Low nebula, are similar in both distribution and velocity to those of the 2 micrometer S(1) line of molecular hydrogen and of the high velocity wings of rotational CO emission. The OI emission from the KL nebula can be produced in the shocked gas associated with the mass outflows in this region and is an important coolant of the shocked gas.

Werner, M. W.↗

Observations of Comet Levy (1990c) with the Hopkins Ultraviolet Telescope

Observations of Comet Levy (1990c) were made with the Hopkins Ultraviolet Telescope during the Astro-1 Space Shuttle mission on December 10, 1990. The spectrum, covering the wavelength range 415-1850 A at a spectral resolution of 3 A, shows the presence of carbon monoxide and atomic hydrogen, carbon, and sulfur in the coma. Aside from H I Lyman-beta, no cometary features are detected below 1200 A, although cometary O I and O II would be masked by the same emissions present in the day airglow spectrum. The 9.4 x 116 arcsecond aperture corresponds to 12,000 x 148,000 km at the comet. The derived production rate of CO relative to water is 0.11 + or - 0.02, compared with 0.04 + or - 0.01 derived from IUE observations (made in September 1990) which sample a much smaller region of the coma. This suggests the presence of an extended source of CO, as was found in comet Halley. Upper limits on Ne and Ar abundance are within one order of magnitude of solar abundances.

Feldman, P. D.↗

Density wave triggered star formation in grand design spirals

In normal spiral galaxies the arms are the main sites for star formation. This is the cause of their optical contrast compared with the rest of the disc. The spiral structure can be observed as a higher concentration of H2 regions, neutral gas (both atomic and molecular via CO), dust and stars than in the interarm disc. It seens generally accepted that, at least in grand design spirals, there are density waves in the discs. However, several questions are not clear yet and still under discussion. An important question could be termed the triggering dilemma (by analogy with the 'winding dilemma' raised in the forties): Is the enhanced star formation in the spiral arms triggered by the passage of a system of density waves or is it simply due to the presence of a higher column density of gas there? In the present work, we use triggering in the same sense as the moderate to strong triggering defined by Elmegreen (1992), that is to say that star formation in the arms occurs at a rate faster than that in the interarm zone, relative to the available placental gas. Our group has designed several tests to elucidate whether or not star formation is triggered in the arms with respect to the interarm region and we summarize one of them, that of the ratio of the star formation efficiency in the arms divided by that of the interarm zone at the same galactocentric distance which we may call the relative massive star formation efficiency, where the efficiency is defined using the ratio of the mass of stars (evaluated via the H alpha flux) to the mass of neutral gas, atomic plus molecular (which must be measured with the adequate angular resolution). If the relative efficiency is of order unity, the star formation is proportional to the mass of gas, if some kind of induced star formation is present, the relative efficiency should be considerably larger than unity.

Cepa, J.↗

Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System

Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.

Wiberg, D. V.↗

Crystallization Physics in Biomacromolecular Systems

The crystals are built of molecules of protein, nucleic acid and their complexes, like viruses, approx. 5x10(exp 3)+ 3x10(exp 6) Da in weight and 2 + 20 nm in effective diameter. This size strongly exceeds action range of molecular forces and makes a big difference with inorganic crystals. Intermolecular contacts form patches on the biomacromolecular surface. Each patch may occupy only a small percent of the whole surface and vary from polymorph to polymorph of the same protein. Thus, under different conditions (pH, solution chemistry, temperature, any area on the macromolecular surface may form a contact. The crystal Young moduli, E approx. equals 0.1 + 0.5 GPa are more than 10 times lower than that of inorganics and the biomolecules themselves. Water within biocrystals (30-70%) is unable to flow unless typical deformation time is longer than approx. 10(exp -5)s. This explains the discrepancy between light scattering and static measurements of E. Nucleation and Growth requires typically concentrations exceeding the equilibrium ones up to 100 times - because of the new size scale results in 10 - 10(exp 3) times lower kinetic coefficients than that needed for inorganic solution growth. All phenomena observed in the latter occur with protein crystallization and are even better studied by AFM. Crystals are typically facetted. Among unexpected findings of general significance are - net molecular exchange flux at kinks is much lower than that expected from supersaturation, steps with low (< approx. 10(exp -2)) kink density at steps follow Gibbs-Thomson law only at very low supersaturations, step segment growth rate may be independent of step energy. Crystal perfection is a must of biocrystallization to achieve the major goal to find 3-D atomic structure of biomacromolecules by x-ray diffraction. Poor diffraction resolution (> 3Angstrom) makes crystallization a bottleneck for structural biology. All defects typical of small molecule crystals are found in biocrystals, but the defects responsible for poor resolution are not identified. Conformational changes are one of them. Biocrystallization in microgravity reportedly results in 20% cases of better crystals. The mechanism of how lack of convection can do this is still not clear. Lower supersaturation, self-purification &om preferentially trapped homologous impurities and step bunching are viable hypotheses.

Chernov, A. A.↗

An X-Ray Spectroscopic Search For Dark Matter And Unidentified Line Signatures In The Perseus Cluster With Hitomi

The reported detection of a 3.5 keV emission signal in the Perseus cluster core by Bulbulet al. (2014, ApJ, 789, 13) was ruled out at high confidence in analysis conducted by Aharonian et al. (2017, ApJ, 837, L15) of X-ray spectra at 5 eV energy resolution obtained with the Hitomi observatory Soft X-ray Spectrometer (SXS). Using the same data, we search the full 2–12 keV SXS energy band for previously unidentified emission and absorption features. No significant unidentified line emission or absorption is found. Line flux upper limits (1σper resolution element) vary with photon energy and assumed intrinsic width, decreasing from∼100 at 2 keV to<10 photons cm−2s−1sr−1over most of the 5–10 keV energy range for a Gaussian line with Doppler broadening of 640 kms−1. Limits for narrower and broader lines have a similar energy dependence and are systematically smaller and larger, respectively. These line flux limits are used to constrain the decay rate of hypothetical dark matter candidates. For the sterile neutrino decay rate, we place new constraints over the mass range of 4–24 keV with mass resolution better than any previous X-ray analysis. Additionally, the accuracy of relevant thermal spectral models and atomic data are evaluated. The Perseus cluster spectra may be described by a composite of multi-temperature thermal and active galactic nuclei (AGN) power-law continua. Superposed on these, a few line emission signals possibly originating from unmodeled atomic processes (including SiXIV and FeXXV)are marginally detected and tabulated. Comparisons with previous X-ray upper limits and future prospects for dark matter searches using high-energy resolution spectroscopy are discussed.

Takayuki Tamura↗

Improved Process for Fabricating Carbon Nanotube Probes

An improved process has been developed for the efficient fabrication of carbon nanotube probes for use in atomic-force microscopes (AFMs) and nanomanipulators. Relative to prior nanotube tip production processes, this process offers advantages in alignment of the nanotube on the cantilever and stability of the nanotube's attachment. A procedure has also been developed at Ames that effectively sharpens the multiwalled nanotube, which improves the resolution of the multiwalled nanotube probes and, combined with the greater stability of multiwalled nanotube probes, increases the effective resolution of these probes, making them comparable in resolution to single-walled carbon nanotube probes. The robust attachment derived from this improved fabrication method and the natural strength and resiliency of the nanotube itself produces an AFM probe with an extremely long imaging lifetime. In a longevity test, a nanotube tip imaged a silicon nitride surface for 15 hours without measurable loss of resolution. In contrast, the resolution of conventional silicon probes noticeably begins to degrade within minutes. These carbon nanotube probes have many possible applications in the semiconductor industry, particularly as devices are approaching the nanometer scale and new atomic layer deposition techniques necessitate a higher resolution characterization technique. Previously at Ames, the use of nanotube probes has been demonstrated for imaging photoresist patterns with high aspect ratio. In addition, these tips have been used to analyze Mars simulant dust grains, extremophile protein crystals, and DNA structure.

Stevens, R.↗

Far ultraviolet excitation processes in comets

Recent observations of atomic oxygen and carbon in the far ultraviolet spectrum of comet Kohoutek have demonstrated the existence of these atomic species in the cometary coma. However, in order to identify the source of their origin, it is necessary to relate the observed ultraviolet flux to the atomic production rate. Analyses of observed OI wavelength 1304 and CI wavelength 1657 A multiplets have been carried out using high resolution solar spectra. Also examined is the possibility of observing ultraviolet fluorescence from molecules such as CO and H2, as well as resonance scattering either from atomic ions for which there are strong corresponding solar lines (CII) or from atoms for which there is an accidental wavelength coincidence (SI).

Feldman, P. D.↗

An e.s.c.a. study of atomic oxygen interactions with phosphazene-coated polyimide films

Metallic as well as most nonmetallic materials experience oxidation and mass loss via surface erosion in low earth orbit as shown in previous Space Shuttle flights. This study is an evaluation of select polyphosphazene polymers and their resistance to atomic oxygen attack. Electron spectroscopy for chemical analysis examinations of the surfaces of polyphosphazene coatings were monitored for microstructural changes induced during exposures to atomic oxygen. Sample exposures in oxygen plasmas and O(3P) beam were compared as to their effect on surface compositional changes in the polyphosphazene coating. High resolution line scans revealed rearrangements in the polymer backbone and scissioning reactions involving fluorocarbon units of long chain fluoroalkoxy pendant groups. Atom percents and peak areas of all species provided a detailed profile of the microstructural changes induced in phosphazene polymers as a result of exposures to atomic oxygen.

Fewell, Larry L.↗

Tokamak Spectroscopy for X-Ray Astronomy

This paper presents the measured x-ray and Extreme Ultraviolet (XUV) spectra of three astrophysically abundant elements (Fe, Ca and Ne) from three different tokamak plasmas. In every case, each spectrum touches on an issue of atomic physics that is important for simulation codes to be used in the analysis of high spectral resolution data from current and future x-ray telescopes. The utility of the tokamak as a laboratory test bed for astrophysical data is demonstrated. Simple models generated with the HULLAC suite of codes demonstrate how the atomic physics issues studied can affect the interpretation of astrophysical data.

Fournier, Kevin B.↗

Need for high resolution in VUV Rydberg state spectroscopy

The paper emphasizes the necessity of high energy resolution (resolving powers greater than 100,000) in VUV spectroscopic determinations of atomic and molecular Rydberg electronic structures. Attention is given to spectral observations of Rydberg levels in Ge I near the 4p 2P(0)1/2 limit, in Sr I near the 4d 2D3/2 limit, and in diatomic hydrogen halides (especially H I) below the X2Pi3/2 limit.

Ginter, M. L.↗

Observation of a Rydberg series of CO in the two-electron excited region

Using synchrotron radiation as a continuum background, the absorption spectrum of CO in the 380-470 A range was taken by using a double ion chamber. A Rydberg series in the 450 A (27.5 eV) region has been observed to converge to the F 2Pi, a two-electron excited state of CO(+). The series limit determined at 28.11 eV is in excellent agreement with the vertical ionization potential of the F 2Pi state measured by the high resolution photoelectron spectroscopy. A few dissociation processes leading to the productions of atomic ions and excited atomic fragments are also discussed.

Wu, C. Y. R.↗

Characteristics of annealed p/n junctions between GaAs and Si(100)

Electrical characteristics of a GaAs(p)/Si(n) interface were determined from capacitance-voltage, current-voltage, and secondary ion mass spectroscopy (SIMS) measurements and compared to those on GaAs(p) epitaxial layers on GaAs(n) substrates. The comparison was made between the junctions as grown, and after an anneal at 850 C for 20 min in 10 percent forming gas under an As overpressure. For the GaAs/Si junction the ideality factor changed from 2 or larger to 1.5 and the apparent intercept voltage changed from 2.5 to 1.3 V after annealing. For the GaAs homojunction, the intercept voltage increased from 1.1 to 1.3 V. In addition, the excess current in the forward and reverse bias conditions dropped drastically in the heterojunction. No movement of the metallurgical junction was discernible to within the resolution capability of SIMS. The junction properties obtained by annealing suggest an atomic restructuring of the Si(100) interface during growth or annealing. These new results raise the possibility that the GaAs/Si interface can be made into an electrically viable junction and incorporated into active devices.

Unlu, M. S.↗

Optical probing of cold trapped atoms

Transitions between excited states of laser-cooled and laser-trapped rubidium and cesium atoms are probed by use of fiber and diode lasers. High-resolution Doppler-free spectra are detected by observation of the absorption and fluorescence of light from the intermediate level of two-step cascade systems. The optical double-resonance spectra show Autler-Townes splitting in the weak probe limit and more complicated spectra for a strongly coupled three-level system.

Fox, R. W.↗