Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic resolution imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bragg Spot Finder (BSF): a new machine-learning-aided approach to deal with spot finding for rapidly filtering diffraction pattern images

Macromolecular crystallography contributes significantly to understanding diseases and, more importantly, how to treat them by providing atomic resolution 3D structures of proteins. This is achieved by collecting X-ray diffraction images of protein crystals from important biological pathways. Spotfinders are used to detect the presence of crystals with usable data, and the spots from such crystals are the primary data used to solve the relevant structures. Having fast and accurate spot finding is essential, but recent advances in synchrotron beamlines used to generate X-ray diffraction images have brought us to the limits of what the best existing spotfinders can do. This bottleneck must be removed so spotfinder software can keep pace with the X-ray beamline hardware improvements and be able to see the weak or diffuse spots required to solve the most challenging problems encountered when working with diffraction images. In this paper, we first present Bragg Spot Detection (BSD), a large benchmark Bragg spot image dataset that contains 304 images with more than 66 000 spots. We then discuss the open source extensible U-Net-based spotfinder Bragg Spot Finder (BSF), with image pre-processing, a U-Net segmentation backbone, and post-processing that includes artifact removal and watershed segmentation. Finally, we perform experiments on the BSD benchmark and obtain results that are (in terms of accuracy) comparable to or better than those obtained with two popular spotfinder software packages ( Dozor and DIALS ), demonstrating that this is an appropriate framework to support future extensions and improvements.

36 MATERIALS SCIENCE↗

Open Reproducible Electron Microscopy Data Analysis

Electron microscopy (EM) is a cornerstone technique in the materials and biological sciences capable of imaging structures at nano- to atomic-scale resolution. Advances in technologies mean that one acquires datasets at increasing data rates and sizes. These advancements present enormous opportunities for researchers to understand complex systems. However, processing the resulting large-scale, complex data in a reproducible and shareable way is a real challenge for researchers. The building, managing, and maintaining complex workflows in a reproducible manner requires extensive knowledge in several areas outside the researchers’ core skill sets, such as software engineering, data science, and high-performance computing (HPC). Our work demonstrates an innovative approach to solving these problems, enabling reproducible EM data analysis through container encapsulated pipelines. Using modern container technologies, we encapsulate processing elements and connect them using shared memory. We expose user-friendly, advanced algorithms and tools to allow end users to utilize without expert programming skills. The platform enables reproducible, scalable, shareable pipelines for the analysis and visualization of EM data. Focusing on interoperability, we leverage the DOE and other agencies’ existing investments to provide a powerful software platform for EM data analysis.

Harris, Christopher↗

The Evolution of the Deformation Substructure in a Ni-Co-Cr Equiatomic Solid Solution Alloy

The equiatomic NiCoCr alloy exhibits an excellent combination of strength and ductility, even greater than the FeNiCrCoMn high entropy alloy, and also displays a simultaneous increase in strength and ductility with decreasing the testing temperature. To systemically investigate the origin of the exceptional properties of NiCoCr alloy, which are related to the evolution of the deformation substructure with strain, interrupted tensile testing was conducted on the equiatomic NiCoCr single-phase solid solution alloy at both cryogenic and room temperatures at five different plastic strain levels of 1.5%, 6.5%, 29%, 50% and 70%. The evolution of deformation substructure was examined using electron backscatter diffraction (EBSD), transmission Kikuchi diffraction (TKD), conventional transmission electron microscopy (CTEM), diffraction contrast imaging using STEM (DCI-STEM) and atomic resolution scanning transmission electron microscopy. While the deformation substructure mainly consisted of planar dislocation slip and the dissociation of dislocations into stacking faults at small strain levels (≤6.5%), at larger strain levels, additional substructures including nanotwins and a new phase with hexagonal close packed (HCP) lamellae also appeared. The volume fraction of the HCP lamellae increases with increasing deformation, especially at cryogenic temperature. First principles calculations at 0 K indicate that the HCP phase is indeed energetically favorable relative to FCC for this composition. The effects of the nanotwin and HCP lamellar structures on hardening rate and ductility at both cryogenic and room temperature are qualitatively discussed.

Twinning↗

Uncovering the three-dimensional structure of upconverting core–shell nanoparticles with multislice electron ptychography

In photon upconverting core–shell nanoparticles, structure strongly dictates performance. Typical imaging in scanning transmission electron microscopy has sufficient resolution to probe the atomic structure of these nanoparticles, but contrast, dose, and projection limitations make conventional methods insufficient for fully characterizing these structures. Phase retrieval techniques provide a promising alternative imaging mode, and, in particular, multislice electron ptychography can recover depth-dependent information. Here, we study beam-sensitive photon upconverting core–shell nanoparticles with a multislice ptychography approach using a low electron dose to avoid damage. Large strain fields arise in these heterostructures due to the mismatch in lattice parameter between the core and the shell. We reconstruct both a nanoparticle that appears defect-free and one that has a large break in the side and map the distribution of strain in 3D by computing distortion fields from high-resolution potential images of each slice. In the defect-free nanoparticle, we observe twisting of the shell, while in the broken nanoparticle, we measure the 3D position of the crack, the core, and dislocations. These results highlight the advantage of multislice electron ptychography to recover 3D information from a single scan, even under strict electron dose requirements from beam-sensitive samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

Revealing the Atomic Structures of Exposed Lateral Surfaces for Polymorphic Manganese Dioxide Nanowires

Polymorphic 1D MnO 2 nanostructures are widely applied in fields such as catalysis, sensing, and energy storage with the functionality mainly determined by the atomic patterns of their laterally exposed facets, which largely remain unclear so far. Herein, by high‐resolution transmission electron microscopy (HRTEM) imaging directly along their axial directions, the atomic structures of the outmost lateral facets of polymorphic MnO 2 nanowires are disclosed. To generalize the findings, four most commonly seen phases with characteristic tunnel structures are targeted, i.e., β‐, γ‐, α‐, and todorokite(t)‐MnO 2 , which are synthesized conventionally using a hydrothermal method reported in the literature. Axially imaging these MnO 2 nanowires via HRTEM, the {hkl} facets covering the lateral surfaces are accurately indexed, the atomic pattern of each {hkl} facet is revealed, and it is further coupled with the outmost tunnel configuration that can significantly affect the physicochemical property of MnO 2 materials via tunnel‐driven mass adsorption/transport. This work provides a reliable reference for atomic modeling of MnO 2 to benefit the pursuit of its structure–property relationship; in addition, it can benefit surface engineering strategies to better rationalize the facet growth control with optimized functionality.

Yuan, Yifei↗

Determination of the Maturation Status of Dendritic Cells by Applying Pattern Recognition to High-Resolution Images

The maturation or activation status of dendritic cells (DCs) directly correlates with their behavior and immunofunction. A common means to determine the maturity of dendritic cells is from high-resolution images acquired via scanning electron microscopy (SEM) or atomic force microscopy (AFM). While direct and visual, the determination has been made by directly looking at the images by researchers. Here we report a machine learning approach using pattern recognition in conjunction with cellular biophysical knowledge of dendritic cells to determine the maturation status of dendritic cells automatically. The determination from AFM images reaches 100% accuracy. The results from SEM images reaches 94.9%. The results demonstrate the accuracy of using machine learning for accelerating data analysis, extracting information, and drawing conclusions from high-resolution cellular images, paving the way for future applications requiring high-throughput and automation, such as cellular sorting and selection based on morphology, quantification of cellular structure, and DC-based immunotherapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mars Environmental Compatibility Assessment (MECA): Identifying the Hazards of the Martian Soil

Sometime in the next decade NASA will decide whether to send a human expedition to explore the planet Mars. The Mars Environmental Compatibility Assessment (MECA) has been selected by NASA to evaluate the Martian environment for soil and dust hazards to human exploration. The integrated MECA payload contains three elements: a wet-chemistry laboratory, a microscopy station, and enhancements to a lander robot-arm system incorporating arrays of material patches and an electrometer to identify triboelectric charging during soil excavation. The wet-chemistry laboratory will evaluate samples of Martian soil in water to determine the total dissolved solids, redox potential, pH, and quantify the concentration of many soluble ions using ion-selective electrodes. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. MECA's microscopy station combines optical and atomic-force microscopy with a robot-arm camera to provide imaging over nine orders of magnitude, from meters to nanometers. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined on the microscope stage using an ar-ray of sample receptacles and collection substrates, and an abrasion tool,. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Although selected by NASA's Human Exploration and Development of Space Enterprise, the MECA instrument suite also has the capability to address basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogical, petrological, and reactivity of Martian surface materials should be constrained: the NMCA experiment will shed light on these quantities through its combination of chemistry and microscopy. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond.

Meloy, T. P.↗

Quantitative three-dimensional imaging of chemical short-range order via machine learning enhanced atom probe tomography

Abstract Chemical short-range order (CSRO) refers to atoms of specific elements self-organising within a disordered crystalline matrix to form particular atomic neighbourhoods. CSRO is typically characterized indirectly, using volume-averaged or through projection microscopy techniques that fail to capture the three-dimensional atomistic architectures. Here, we present a machine-learning enhanced approach to break the inherent resolution limits of atom probe tomography enabling three-dimensional imaging of multiple CSROs. We showcase our approach by addressing a long-standing question encountered in body-centred-cubic Fe-Al alloys that see anomalous property changes upon heat treatment. We use it to evidence non-statistical B 2 -CSRO instead of the generally-expected D0 3 -CSRO. We introduce quantitative correlations among annealing temperature, CSRO, and nano-hardness and electrical resistivity. Our approach is further validated on modified D0 3 -CSRO detected in Fe-Ga. The proposed strategy can be generally employed to investigate short/medium/long-range ordering phenomena in different materials and help design future high-performance materials.

36 MATERIALS SCIENCE↗

Atomic-Scale Structure and Non-Stoichiometry of Meteoritic Hibonite: A Transmission Electron Microscope Study

Hibonite (CaAl_12O_19) is a common refractory mineral in Ca-Al-rich inclusions (CAIs) in primitive meteorites. Transmission electron microscope (TEM) studies have identified enigmatic planar defects in different occurrences of hibonite in the Allende meteorite that give rise to strong streaking along c* in electron diffraction patterns. Atomic resolution high-angle annular dark-field (HAADF) imaging and energy-dispersive X-ray (EDX) analyses were used to determine the nature and origin of these planar features. HAADF images of hibonite grains reveal lamellar intergrowths of common 1.6 nm spacing, and less commonly 2.0 and 2.5 nm spacings, interspersed in stoichiometric hibonite showing 1.1 nm (002) spacing. Stoichiometric hibonite consists of alternating Ca-containing (“R”) and spinel-structured (“S”) blocks stacked in a sequence RS. In contrast, the 1.6 nm layers result from a doubled S block such that the stacking sequence is RSS, while in the widest defect observed, the stacking sequence is RSSSS. These intergrowths are epitaxial and have coherent, low-strain boundaries with the host hibonite Meteoritic hibonite shows common Ti and Mg substitution for Al in its structure. Atomic-resolution EDX maps of hibonite grains in the Allende CAI confirm the preferred site occupancy of Mg on tetragonal M3 sites in S blocks and of Ti on trigonal bipyramidal M2 and octahedral M4 sites in R blocks. Mg is highly concentrated, but Ti is absent in the planar defects where wider S blocks show Al-rich compositions compared to stoichiometric MgAl_2O_4 spinel. Therefore, Mg likely played the major role in the formation and metastability of planar defects in hibonite. Electron energy loss spectroscopy data from the Ti L_2,3 edge show the presence of mixed Ti oxidation states with ~ 15–20% of Ti as Ti^(3+) in hibonite, suggesting a direct substitution of Ti^(3+) ↔ Al^(3+) in hibonite. The remaining ~ 80–85% of Ti is present as Ti^(4+) and corresponding EDX analyses are consistent with the well-known coupled substitution 2Al^(3+) ↔ Ti^(4+) + Mg^(2+) being the major mechanism for Ti and Mg substitution in hibonite. The formation of planar defects in hibonite occurred during high-temperature nebular condensation or melting/crystallization processes. The occurrence of non-stoichiometric hibonite in the Allende CAI deviates from the mineral formation sequence predicted from equilibrium condensation models. Overall, our atomic resolution TEM observations signify non-equilibrium, kinetic-controlled crystal growth during the high-temperature formation of refractory solids in the early solar nebula.

hibonite↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Radiation damage study of POCO ZXF-5Q graphite for neutrino production targets using 4.5 MeV helium ions

To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.

43 PARTICLE ACCELERATORS↗

Fast Preparation and Detection of a Rydberg Qubit Using Atomic Ensembles

Here, we demonstrate a new approach for fast preparation, manipulation, and collective readout of an atomic Rydberg-state qubit. By making use of Rydberg blockade inside a small atomic ensemble, we prepare a single qubit within 3 μs with a success probability of $F_p$ = 0.93 ± 0.02, rotate it, and read out its state in 6 μs with a single-shot fidelity of $F_d$ = 0.92 ± 0.04. The ensemble-assisted detection is 10 3 times faster than imaging of a single atom with the same optical resolution, and enables fast repeated nondestructive measurement. We observe qubit coherence times of 15 μs, much longer than the π rotation time of 90 ns. Potential applications ranging from faster quantum information processing in atom arrays to efficient implementation of quantum error correction are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-time sparse-sampled Ptychographic imaging through deep neural networks

Ptychography has rapidly grown in the fields of X-ray and electron imaging for its unprecedented ability to achieve nano or atomic scale resolution while simultaneously retrieving chemical or magnetic information from a sample. A ptychographic reconstruction is achieved by means of solving a complex inverse problem that imposes constraints both on the acquisition and on the analysis of the data, which typically precludes real-time imaging due to computational cost involved in solving this inverse problem. In this work we propose PtychoNN, a novel approach to solve the ptychography reconstruction problem based on deep convolutional neural networks. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. The presented results demonstrate how PtychoNN can effectively be used on experimental data, being able to generate high quality reconstructions of a sample up to hundreds of times faster than state-of-the-art ptychography reconstruction solutions once trained. By surpassing the typical constraints of iterative model-based methods, we can significantly relax the data acquisition sampling conditions and produce equally satisfactory reconstructions. Besides drastically accelerating acquisition and analysis, this capability can enable new imaging scenarios that were not possible before, in cases of dose sensitive, dynamic and extremely voluminous samples.

Cherukara, Mathew J↗

Low Temperature Oxygen Activation on the NiAg(100) Single-Atom Alloy Surface

Silver-catalyzed ethylene epoxidation remains the only industrially viable route for ethylene oxide (EO) production. However, this process requires chlorine and other promoters to achieve a high EO selectivity while still generating substantial CO 2 emissions. A recent theory-guided approach identified Ni, in single-atom alloy (SAA) form, as a new promoter of this reaction. Specifically, the addition of Ni to Ag nanoparticles supported on α-Al 2 O 3 at a highly diluted ratio (1 Ni per 200 Ag atoms) increased catalyst selectivity to EO by ∼25%, the same increase afforded by the ubiquitous industrial promoter chlorine. To better understand the effect of Ni, we investigated the interaction of O 2 with NiAg(100) SAA surfaces by using scanning tunneling microscopy (STM) and density functional theory (DFT). While only molecular O 2 was present when pure Ag(100) was exposed to O 2 at 78 K, a distinct NiO 2 species, indicative of O 2 dissociation at Ni atom sites, was identified on the NiAg(100) SAA under the same conditions. High-resolution STM imaging backed by DFT simulations elucidated the formation of an O−Ni−O species with the oxygen atoms in 4-fold hollow sites. These findings provide direct experimental evidence that Ni atoms are very effective at O 2 activation, even at cryogenic temperatures. This suggests that, in addition to the known role of Ni in stabilizing the unselective nucleophilic oxygen on Ag, it could also accelerate O 2 dissociation, which can be rate limiting.

Catalysts↗

Identification of the glassy state in nanoparticles by transmission electron microscopy

Identification of amorphous phases in nanoparticles by atomic-resolution transmission electron microscopy (TEM) requires analyses such as tilt-angle-dependent TEM imaging and single-nanoparticle electron diffraction, rather than relying on a single TEM image. Here, the disordered structures of amorphous nanoparticles offer unique atomic configurations and properties that differ from the properties of their crystalline counterparts. These characteristics have motivated the exploration of such materials for mechanical, sensing and catalytic applications. In addition, the formation of amorphous metal nanoparticles is an important endeavour to understand the process of vitrification and the nature of the glassy state. Atomic-resolution transmission electron microscopy (TEM) is increasingly being used as a tool for characterizing structures of nanoparticles produced by vitrification. In this Comment, we discuss the pitfalls of using TEM for ascertaining whether nanoparticles are amorphous. We also make recommendations of best practices.

Alcorn, Francis M. [Sandia National Laboratories (↗

Atomic-scale cryogenic electron microscopy imaging of self-assembled peptoid nanostructures

Amphiphilic polypeptoids with defined sequences, versatile in forming various nanostructures, are ideal for mimicking biomacromolecular structures. The predictive design of nanostructures depends on our understanding of the relationship between molecular structure and the locations of atoms in the nanostructure. Factors of importance include chain conformation, crystal motifs, and the arrangement of the molecules within the nanostructure. Here, this review introduces the cryogenic transmission electron microscopy (cryo-TEM) method, sorting and averaging unit cells in nanosheets for resolution enhancement and identifying structural heterogeneity. The resulting atomic-scale images reveal the presence of two types of crystal motifs. The impact of processing conditions, capping group chemistry, and side chain chemistry on structural heterogeneity and crystal motifs can be quantified. The 3D reconstruction of nanosheets, wherein atomic-scale corrugations were revealed, is introduced in this review. New developments in cryo-TEM, such as phase retrieval reconstruction, hold great promise for atomic-scale imaging of soft nanostructures.

36 MATERIALS SCIENCE↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗