Search NASA⌕ Search

SEARCH · Search NASA

Results for “Autonomous Power Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Robotics for Energy Infrastructure Construction on Earth and Beyond: Pilot Study Exploring Level 3-4 Semi-Autonomous Installation of a Reduced-Scale Photovoltaic Power Plant Prototype: Preprint

There is a growing need to build energy infrastructure at massive scale on both Earth and in space. On Earth, increasing electricity demand from applications such as AI data centers is driving rapid expansion of power systems, while in space, long-duration missions such as lunar operations require reliable and resilient energy infrastructure that can be deployed quickly. These needs outpace the capabilities of conventional construction methods. Robotic construction offers a path to faster, lower-cost, and more consistent deployment, yet most existing approaches focus on automating individual tasks rather than end-to-end assembly. The Industrialized Construction Innovation (ICI) team at the National Laboratory of the Rockies (NLR), in collaboration with the Colorado School of Mines, has been investigating robotics and automation strategies for rapid end-to-end energy infrastructure construction. This paper presents a pilot study demonstrating level 3-4 semi-autonomous, end-to-end robotic assembly of a reduced-scale photovoltaic power plant prototype under terrestrial conditions. The approach combines hardware redesign of photovoltaic components for robotic compatibility, discrete-event and physics-based robotic simulations in synthetic environments, and sim-to-real deployment to execute end-to-end robotic assembly of[NM1.1][NM1.2] tracking components, structural members, photovoltaic modules, and embedded electrical connections. The pilot identifies key limitations like tolerance management, perception and localization, end effector capability, fastening methods, and multi-physics simulation fidelity, that must be addressed to enable end-to-end robotic assembly of full-scale energy infrastructure. The study highlights how these insights inform scaling strategies for terrestrial energy infrastructure and adaptation to unstructured and extreme environments, including off-world scenarios such as robotic assembly of vertical tall lunar towers.

14 SOLAR ENERGY↗

Synchrophasor spoofing detection and remediation for wide-area damping control

Evolving cyber-attack threats put at risk automatic closed-loop systems to be incorporated in the smart grid. Wide-area control systems are particularly vulnerable to signal spoofing attacks due to sensor remoteness and dependence on satellite communication for time synchronization. A successful cyber-attack on a wide-area controller has the potential to reduce relative stability of the power system or worse, destabilize it. As such, detection algorithms must be deployed as defense against such attacks with the ability to autonomously correct for detected tampering or misoperation. The Spoof Catch and Restore Routine (SCR 2 ), a combination of three real-time spoof detectors, each requiring limited information about the plant, is reported here. Nonlinear simulations of a compromised wide-area control system deployed in the Western Interconnection show the effectiveness of SCR 2 in detecting both delay-type and counterfeit-type spoofing attacks on wide-area sensors.

42 ENGINEERING↗

Meeting the Challenges of Modern Transit through the Integration of Traditional Transit, On-Demand Micro-Transit Services and Vehicle Automation - A Case Study in Chandler, Arizona

Current technology trends of vehicle automation, electrification and on-demand transit are providing new tools to develop effective public mobility services, yet need to be balanced with traditional modes to serve the spectrum of demand effectively and efficiently. Automated vehicle transportation network company (TNC) services, better known as 'Robotaxis' are beginning to proliferate and scale across the US, with Waymo as the lead commercial entity. Chandler, AZ was the first fully automated deployment of Waymo technology. Chandler was also one of the first municipalities in Arizona to roll out micro-transit service to its citizens in 2022. At present the Chandler Flex micro-transit program is beginning to partner with Waymo to augment micro-transit services during peak demands, another first in the nation. However, the mix of services in Chandler relies not only on new technology, but also on traditional modes including fixed route transit and para-transit services. These are blended and balanced such that both old and new modes are applied within the context in which each excel. This presentation will provide background on the Chandler, AZ public mobility services, and the performance metrics that govern their use and selection within the spectrum of development and population density as well as socio-demographics within Chandler. Additionally, the behavioral response of the use of unmanned, automated vehicles employed to augment micro-transit is novel, the first in the nation - and initial feedback from public transit constituents in Chandler will be shared.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WM26 Paper Multi-Robot Collaboration for Hazardous Environments

Hazardous nuclear and industrial facilities are rarely designed for robots. Work in these domains demand precise manipulation and robust mobility in cluttered, constrained spaces where off-the-shelf platforms struggle and “one-size-fits-all” machines become costly and complex. Idaho National Laboratory (INL) is developing an autonomous, multi-robot inspection system that coordinates task-specific platforms rather than relying on a single omni-tool robot. An electric truck serves as a power and compute hub for a custom manipulator co-developed with Florida International University (FIU), a commercial mini crawler, a pan–tilt–zoom camera, and a Nexxis Argus LiDAR mapping system. Working in concert, these robots generate spatial, radiation, and temperature maps of the pit environments at the Hanford Waste Tank Farms. These systems will capture visual records and environmental telemetry to allow for analysis post inspection. The system architecture uses Robot Operating System 2 (ROS 2) for publish/subscribe integration, NVIDIA Isaac Sim and Unity for simulation and visualization, and algorithms such as NVBlox to fuse data into unified 3D overlays. This robot-agnostic approach reduces operator burden by enabling autonomy across heterogeneous platforms and lets each robot be used where it is strongest. Having autonomous functions means operators don’t have to fully control multiple different components. The ease of use could allow for more widespread adoption of advanced robotics at waste management sites that see continued use. By coordinating simpler, purpose-built mechanisms, the approach lowers design and manufacturing complexity, reduces capital risk in contaminated settings, and improves controllability for complex inspection and manipulation tasks. We present the architecture, early results, and lessons learned from building and deploying this coordinated multi-robot system, with the goal of accelerating safe, cost-effective adoption of advanced robotics at waste-management sites.

42 - ENGINEERING↗

The Future of Renewable Energy Transmission: An Autonomous Energy Grid

The drastic price reduction in variable renewable energy, such as wind and solar, coupled with the ease of use of smart technologies at the consumer level, is driving dramatic changes to the power system that will significantly transform how power is made, delivered, and used. Distributed energy resources (DERs)—which can include solar photovoltaic (PV), fuel cells, microturbines, gensets, distributed energy storage (e.g., batteries, ice storage), and new loads (e.g., electric vehicles (EVs), light-emitting diode (LED) lighting, smart appliances, and electric heat pumps)—are being added to electric grids and causing bidirectional power flows and voltage fluctuations that can impact optimal control and system operation. Residential solar installations, customer battery systems, and EVs are all seeing rapid increases in deployments. With DER seeing such increased use, it is not unreasonable to imagine a residential electricity customer having at least five controllable DERs. In future electric grids, as more DERs are integrated, the number of active control points will be too much for current control approaches to effectively manage.

30 DIRECT ENERGY CONVERSION↗

Final Technical Report Wireless Microsensors System for Monitoring Deep Subsurface Operations

This final technical report describes the main findings of the project Wireless Microsensors System for Monitoring Deep Subsurface Operations (FE0031850). The project was part of the U.S. Department of Energy National Energy Technology Laboratory FOA 1998 program to develop new sensor systems for direct observation of parameters associated with CO2 injection and to provide data collection without being disruptive to operations. The overall DOE program was aimed at developing and validating innovative transformational sensor systems, amenable for integration with autonomous intelligent monitoring systems, that are capable of being deployed within the casing annulus and do not have casing perforation or wires/cables in the annulus for installation, power supply, or data transmission needs. Project accomplishments included 1) design and fabrication of a wireless downhole sensor system to monitor parameters for CO2 storage, 2) field testing of the sensor system in two legacy oil & gas wells, and 3) development of an analysis approach that validates the measurements and demonstrates the application of the technology to depict CO2 movement in the subsurface. The project leveraged new sensor technologies along with specialized wellbore telemetry, deployment, and analysis methods designed to address the challenges and risks related to CO2 storage in the subsurface. Results from field testing were a mixture of successes and challenges. The temperature sensor rings, installation procedures in legacy oil & gas wells, wireless powering demonstration, automated data collection, and material compatibility were successful. The wireless data transfer through cement to the wellhead via the sensor relays was not functional beyond the first relay. Consequently, work in the last year of the project included some additional testing of data transmission through different materials along with modeling and analysis of field data for CO2 monitoring applications. This work suggested there are options like polymer cements and open hole annuli that may allow point-to-point transmission along the borehole. The techno-economic analysis suggests that the sensor system is ~40% less expensive than fiber optic distributed temperature system. Modeling of CO2 storage applications suggests temperature can provide an indicator of CO2 saturation but would be best combined with pressure sensors.

47 OTHER INSTRUMENTATION↗

Development of an Unmanned Mobile Current Turbine Platform: Preprint

The design and development of a prototype unmanned mobile floating platform, equipped with a custom low-flow marine current turbine for autonomously seeking and harnessing tidal/coastal currents is described. The platform is an unmanned surface vehicle in the form of a catamaran with two electric outboard motors and capabilities for autonomous navigation. An undershot water wheel, aided by a custom flow concentrator, has been selected as the basic design for the marine current turbine, which is mounted on the stern of the unmanned surface vehicle platform. The concept of operation is that the platform would navigate to a designated marine current resource, autonomously anchor at the location, align itself in the current and deploy the current turbine using a custom cable-lift deployment mechanism. As the turbine harnesses the local current, an onboard power-take-off device converts the harnessed mechanical energy to electricity which is stored in onboard batteries. Considerations of deployment in tidal and coastal waters required obtaining the necessary environmental permits for conducting in-water testing; developing required mitigation measures in protecting local wildlife and their habitats; and identifying potential in-water test sites and surveying them for their suitability in terms of the current resource, bottom type, water depth, and local boat traffic. The design and development of the turbine and the results of initial in-water testing are discussed. The potential for scaling up the system for extended capacity is presented.

ENGINEERING,TIDAL AND WAVE POWER↗

Robust Decentralized Secondary Control Scheme for Inverter-based Power Networks

Inverter-dominated microgrids are quickly becoming a key building block of future power systems. They rely on centralized controllers that can provide reliability and resiliency in extreme events. Nonetheless, communication failures due to cyber-physical attacks or natural disasters can make autonomous operation of islanded microgrids challenging. This paper examines a unified decentralized secondary control scheme that is robust to inverter clock synchronization errors and can be seamlessly applied to grid-following or grid-forming control architectures. The proposed scheme overcomes the well-known stability problem that arises from parallel operation of local integral controllers. Theoretical guarantees for stability are provided along with criteria to appropriately tune the secondary control gains to achieve good frequency regulation performance while ensuring fair power sharing. The efficacy of our approach is demonstrated through simulations on a 5-bus microgrid with four grid-forming inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization and Evaluation of Energy Savings for Connected and Autonomous Off-Road Vehicles

Off-road vehicles, such as wheel loaders, excavators, and harvesters, are extensively utilized across a wide range of industries, including construction, agriculture, and mining. These machines have become indispensable in supporting the day-to-day operational needs of a nation, playing a critical role in various sectors' infrastructure and productivity. However, despite their utility, off-road vehicles are significant consumers of fossil fuels, resulting in substantial emissions that contribute to environmental degradation. This highlights the pressing need for research and technological advancements aimed at improving their energy efficiency and reducing their carbon footprint. There are, however, two primary challenges that must be addressed to achieve these goals. First, off-road vehicles typically perform both driving and working tasks simultaneously, which introduces a high level of complexity into their overall dynamic systems. Analysis the interactions between these functions is challenging. Second, research into off-road vehicles is inherently interdisciplinary, demanding expertise across several domains such as fluid power systems, vehicle dynamics, control theory, optimization techniques, and real-world implementation. Recognizing these challenges, we proposed the project titled "Optimization and Evaluation of Energy Savings for Connected and Autonomous Off-Road Vehicles" as a comprehensive solution to enhance fuel efficiency while simultaneously improving productivity. This project specifically focuses on autonomous off-road vehicles, with particular attention to wheel loaders, and seeks to develop novel methods to optimize energy consumption without sacrificing operational performance. The project integrates real-time control algorithms, vehicle dynamics modeling, and co-optimization of powertrain system and vehicle system to achieve these goals. Our optimization strategy dynamically co-optimizes critical parameters at both the powertrain and vehicle levels, including vehicle speed, working tool movements, powertrain dynamics, and engine operations in real-time. To streamline this optimization process, we developed a vehicle model that captures the key dynamics while significantly enhancing computational efficiency. This allows the system to intelligently minimize fuel consumption, all while maintaining or even improving productivity through real-time calculations during various off-road operations. To validate the effectiveness of this energy optimization method, we introduced a state-of-the-art Hardware-in-the-Loop (HIL) testbed. This reconfigurable testbed seamlessly integrates the actual engine with virtual models of the wheel loader's subsystems, allowing for accurate emulation of real-world operational loads and environments. By simulating these conditions, the HIL testbed enables us to evaluate the wheel loader’s performance under diverse working scenarios, ensuring the developed solution is applicable in real-world operations. This testbed proved to be instrumental in validating the optimization algorithms and demonstrating the system's practical effectiveness. During the evaluation and testing phase, we employed the HIL testbed to rigorously assess the energy savings and productivity improvements generated by the optimized system. The results were highly encouraging, revealing that the automated wheel loader achieved over 30% fuel savings compared to traditional, human-operated cycles, with comparable or even enhanced levels of productivity. The insights gained from this HIL-based testing provided critical validation of our approach and highlighted the potential for deploying these optimized autonomous technologies in real-world off-road vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Lyapunov-Based Iterative Learning of Regions of Attraction for Autonomous Systems

This paper proposes a novel algorithm for estimating the region of attraction of equilibrium points for nonlinear discrete-time autonomous systems. The method iteratively expands an initial estimate of the region of attraction by constructing unions of sublevel sets of learned functions parametrized as neural networks. Unlike conventional techniques that rely on a single global Lyapunov function, the proposed approach provides a collection of local Lyapunov-like functions, enabling richer representations and potentially larger region of attraction estimates. These functions are trained using sampled state-space data, and their Lipschitz continuity ensures that desirable properties extend beyond the training samples. The devised strategy is tested via numerical simulations, demonstrating the effectiveness of the proposed approach.

97 MATHEMATICS AND COMPUTING↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of thermostatically controlled loads

Apparatus and methods for a market-based control framework to coordinate a group of autonomous thermostatically controlled loads (TCL) to achieve system-level objectives with pricing incentives is disclosed. In one example of the disclosed technology, a method of providing power to a load via a power grid by submitting bids to a coordinator includes determining an energy response relating price data for one or more energy prices to quantity data for power to be consumed by the load, sending a bid for power for a finite time period based on the energy response to the coordinator, and receiving a clearing price based on: the bid, on bids received from a plurality of additional loads, and a feeder power constraint. In some examples, the energy response is based at least in part on an equivalent thermal parameter model and a control policy indicating one or more power states for the load.

Lian, Jianming↗

Discrete and Integrated Solutions for Hybrid PV Plants Without Momentary Cessation in Low SCR and High Penetration PE Grids

With the increased penetration of power electronic (PE) based loads and sources, advanced solutions may be required for the enhancement of grid stability in regions with low short circuit ratio (SCR) and high penetration PE grids. The requirement of advanced solutions arises from the gradual paradigm shift of the electric grid from the traditional electric machine dominant system to a high penetration of PE-based system. One of the major challenges with such systems in recent times is the momentary cessation during alternating current (ac) grid transmission faults. During momentary cessation, PE-based resources cease to operate, thus creating probable reliability challenges for the grid. In this paper, potential feasible options to provide continuity of operation during such scenarios are presented. The options are considered through identifying upgrades in existing and upcoming discrete development of photovoltaic (PV) and energy storage systems (ESS) termed as discrete hybrid PV plants. Additionally, an advanced concept of integrated development of PV and ESS connecting to ac transmission grid links called multi-port autonomous reconfigurable solar power plant (MARS) is evaluated. The developed new solutions are evaluated for different grid use cases and scenarios in PSCAD.

Marthi, Phani Ratna Vanamali↗