Search NASA⌕ Search

SEARCH · Search NASA

Results for “Axis Tilt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The absorption of trapped particles by the inner satellites of Jupiter and the radial diffusion coefficient of particle transport

The process of trapped particle absorption by the inner Jovian satellites is considered in detail taking into account both the particle and satellite motions in a magnetic dipole field which is displaced from the center of the planet and tilted with respect to the planetary rotation axis. An expression is derived for computing the sweeping time at a given satellite, defined as the time required for the satellite to sweep up a given fraction of the trapped particles within its sweeping region. By making use of the sweeping time and the radial diffusion equation of particle transport approximate expressions for the diffusion coefficient are derived. Measurements obtained by Pioneer 10 are then used to obtain estimates of the diffusion coefficient at the orbits of Io and Europa. We find that the diffusion coefficient is a function of energy and magnetic latitude for electrons in the energy range 0.7-14 MeV.

Mogro-Campero, A.↗

Horizontal thermal structure of the mesosphere from observations of OH/8-3/ band emissions

Two computerized tilting-filter photometers and a programmable dual axis mirror system have been used to produce maps of OH rotational temperature and intensity. Each map consists of a square array of 121 sky positions. Significant horizontal structure is not generally observed in mesospheric OH(8-3) rotational temperature at Arecibo. However, there is evidence for the occasional occurrence of a thermal wave just after evening twilight.

Tepley, C. A.↗

Magnetic field studies by Voyager 2 - Preliminary results at Saturn

Results of Voyager 2 studies of the magnetosphere and planetary magnetic field of Saturn are presented. Magnetometer studies have confirmed the results obtained by Voyager 1, indicating the magnetic field to be that of a centered dipole of moment 0.21 gauss Saturn radii-cubed, tilted approximately 0.8 deg from the rotation axis and a maximum measured field intensity of 1187 nT at latitude 17.3 deg N just before periapsis. Voyager 2 observed multiple bow shock and magnetopause crossings during its inbound and outbound trajectories, which were complementary to those of Voyager 1, including magnetopause crossing at 18.5 Saturn radii on the inbound trajectory, and at 48.4-50.9 Saturn radii outbound indicative of magnetospheric expansion due to changing solar wind conditions. Throughout the outbound passage, the magnetospheric field was observed to be relatively steady and smooth, with no evidence for any azimuthal asymmetry or magnetic anomaly. Results thus are incapable of accounting for the observed periodic modulation of the Saturnian kilometric radio emissions.

Ness, N. F.↗

Coating a Sphere With Evaporated Metal

In vacuum coating apparatus, metal evaporated onto sphere from small source located some distance away. Sphere held in path of metal vapor while rotated about axis that rocks back and forth. One tilting motion particularly easy to produce is sinusoidal rocking with frequency much lower than rotational frequency. Apparatus developed for coating single-crystal sapphire spheres with niobium.

Strayer, D. M.↗

The magnetic field of Uranus

Aspherical harmonic model of the planetary magnetic field of Uranus is obtained from the Voyager 2 encounter observations using generalized inverse techniques which allow partial solutions to complex (underdetermined) problems. The Goddard Space Flight Center 'Q3' model is characterized by a large dipole tilt (58.6 deg) relative to the rotation axis, a dipole moment of 0.228 G R(Uranus radii cubed) and an unusually large quadrupole moment. Characteristics of this complex model magnetic field are illustrated using contour maps of the field on the planet's surface and discussed in the context of possible dynamo generation in the relatively poorly conducting 'ice' mantle.

Connerney, J. E. P.↗

Two-degree-of-freedom image motion compensator for Shuttle-based pointing experiments

The mechanical design of the subarcsec-accurate, high-bandwidth two-DOF image motion compensator developed to enhance Space Shuttle-based optical telescope experiments' pointing accuracy encompasses a gimbal-type flex-pivot suspension, a novel ironless two-axis forcer, and a differential capacitive tilt-sensor system. The image motion compensator was developed to allow the UV Imaging Telescope Sensor to maintain stringent pointing accuracies over extended integration intervals while experiencing typical manned spacecraft perturbations.

Schuster, Ludwig E.↗

The Permanent and Inductive Magnetic Moments of Ganymede

Data acquired by the Galileo magnetometer on five passes by Ganymede have been used to characterize Ganymede's internal magnetic moments. Three of the five passes were useful for determination of the internal moments through quadrupole order. Models representing the internal field as the sum of dipole and quadrupole terms or as the sum of a permanent dipole field upon which is superimposed an induced magnetic dipole driven by the time varying component of the externally imposed magnetic field of Jupiter's magnetosphere give equally satisfactory fits to the data. The permanent dipole moment has an equatorial field magnitude 719 nT and is tilted by 176 degrees from the spin axis with the pole in the southern hemisphere rotated by 24 degrees from the Jupiter-facing meridian plane towards the trailing hemisphere. The data are consistent with an inductive response of a good electrical conductor of radius approximately 1 Ganymede radius. Although the data do not enable us to establish the presence of an inductive response beyond doubt, we favor the inductive response model because it gives a good fit to the data using only 4 parameters to describe the internal sources of fields, whereas the equally good dipole plus quadrupole fit requires 8 parameters. An inductive response is consistent with a buried conducting shell, probably liquid water with dissolved electrolytes, somewhere in the first few hundred km below Ganymede's surface. The depth at which the ocean is buried beneath the surface is somewhat uncertain, but our favored model suggests a depth of order 150 kilometers. As both temperature and pressure increase with depth and the melting temperature of pure ice decreases to a minimum at approximately 170 kilometer depth, it seems possible that near this location, a layer of water would be sandwiched between layers of ice.

Kivelson, M. G.↗

Electronic Absolute Cartesian Autocollimator

An electronic absolute Cartesian autocollimator performs the same basic optical function as does a conventional all-optical or a conventional electronic autocollimator but differs in the nature of its optical target and the manner in which the position of the image of the target is measured. The term absolute in the name of this apparatus reflects the nature of the position measurement, which, unlike in a conventional electronic autocollimator, is based absolutely on the position of the image rather than on an assumed proportionality between the position and the levels of processed analog electronic signals. The term Cartesian in the name of this apparatus reflects the nature of its optical target. Figure 1 depicts the electronic functional blocks of an electronic absolute Cartesian autocollimator along with its basic optical layout, which is the same as that of a conventional autocollimator. Referring first to the optical layout and functions only, this or any autocollimator is used to measure the compound angular deviation of a flat datum mirror with respect to the optical axis of the autocollimator itself. The optical components include an illuminated target, a beam splitter, an objective or collimating lens, and a viewer or detector (described in more detail below) at a viewing plane. The target and the viewing planes are focal planes of the lens. Target light reflected by the datum mirror is imaged on the viewing plane at unit magnification by the collimating lens. If the normal to the datum mirror is parallel to the optical axis of the autocollimator, then the target image is centered on the viewing plane. Any angular deviation of the normal from the optical axis manifests itself as a lateral displacement of the target image from the center. The magnitude of the displacement is proportional to the focal length and to the magnitude (assumed to be small) of the angular deviation. The direction of the displacement is perpendicular to the axis about which the mirror is slightly tilted. Hence, one can determine the amount and direction of tilt from the coordinates of the target image on the viewing plane.

Leviton, Douglas B.↗

Multifluid Simulations of the Global Solar Wind Including Pickup Ions and Turbulence Modeling

I will describe a three-dimensional magnetohydrodynamic model of the solar wind that takes into account turbulent heating of the wind by velocity and magnetic fluctuations as well as a variety of effects produced by interstellar pickup protons. The interstellar pickup protons are treated in the model as one fluid and the protons and electrons are treated together as a second fluid. The model equations include a Reynolds decomposition of the plasma velocity and magnetic field into mean and fluctuating quantities, as well as energy transfer from interstellar pickup protons to solar wind protons that results in the deceleration of the solar wind. The model is used to simulate the global steady-state structure of the solar wind in the region from 0.3 to 100 AU. The simulation assumes that the background magnetic field on the Sun is either a dipole (aligned or tilted with respect to the solar rotation axis) or one that is deduced from solar magnetograms.

Goldstein, Melvyn L.↗

Lunar Plant Experiment: Testing Plant Germination in Lunar Gravity and Ionizing Radiation

We present an open design for a first plant growth module on the Moon (LPX). The primary science goal of lunar habitat is to investigate germination and initial plant growth when subject to the combined effects of lunar gravity and lunar surface radiation. The LPX module has been designed to be a flexible base unit that can be adapted to fly to the lunar surface on a variety of landers and rovers. LPX has size and shape of a 1 Unit CubeSat (10 centimeters on a side) and a total mass of 0.3 kilograms. The base will contain a seed module holding around 50 Arabidopsis seeds and provide approximately 0.5 liters of normal air at standard pressure. By the action of a small pump, water will be released after landing to initiate germination. Images will document the germination, initial growth, phototropism, and circumnutation of the small plants while sunlight remains available. A CO2 sensor tracks the release of CO2 during germination and the subsequent uptake of CO2 by photosynthesis. Simulations indicate that the CO2 peak level will be an increase by 2250 parts per million after 2 earth-days and then decline to about 1000 parts per million after 7 earth-days. The camera and CO2 sensor interfaces are USB. The water pump initiation requires a 5-volt signal. After initiation of germination by the addition of water, the habitat must be maintained above 22 degrees Centigrade to allow for plant growth and below 27 degrees Centigrade to prevent damage to the plants. This relatively tight temperature tolerance will require thermal control systems using reflecting surfaces and insulation that must be specifically designed for each lander or rover. The plant growth unit will function to tilt angles of 20 degrees along any axis. Total image data volume required to gauge the plant growth rate and leaf area is 1 megabyte (minimum data required) to 40 megabytes (preferred data). The lid of the habitat will allow adequate sunlight for plant growth. To provide for optimum growth, light levels in the plant growth stage need to be between 75 and 150 micromoles per meter squared per second interval.

first plant growth↗

Revisiting Voyager 2 Plasma Observations During the Uranus Flyby and Plasma Observation Requirements for Future Mission to Uranus’ Magnetosphere

We revisit the Voyager 2 (V2) plasma observations during its Uranus flyby in Jan 24, 1986. For this flyby it was found to be a highly dynamic magnetosphere with protons [1,2] and electrons [1,3] dominating the plasma environment with significant radiation belts [4,5] and large dipole tilt [6,7] relative to Uranus spin axis. The emphasis of this talk is the measurement requirement for an Ion Mass Spectrometer (IMS) 1 V ≤ E/Q ≤ 50 kV and Electron Plasma Spectrometer (ELS) 1 eV ≤ E ≤ 30 keV; in both cases a wide field-of view 360 x 90. The main measurement goal is “What is the relative composition of the major and minor ion species within Uranus’ magnetospheres, including both the inner magnetosphere, ionospheres, radiation belts and the deep magnetotail regions for both hot and cold ions?

Uranus↗

Ritchey-Chretien Telescope

A Ritchey-Chretien telescope is described which was designed to respond to images located off the optical axis by using two transparent flat plates positioned in the ray path of the image. The flat plates have a tilt angle relative to the ray path to compensate for astigmatism introduced by the telescope. The tilt angle of the plates is directly proportional to the off axis angle of the image. The plates have opposite inclination angles relative to the ray paths. A detector which is responsive to the optical image as transmitted through the plates is positioned approximately on the sagittal focus of the telescope.

Rosin, S.↗

Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control During Variable Radius Centrifugation Following Space Flight

Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, less than 20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. One result of this study will be to characterize the variability (gain, asymmetry) in both otolith-ocular responses and motion perception during variable radius centrifugation, and measure the time course of post-flight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

Wood, Scott J.↗

ZAG-Otolith: Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control during Variable Radius Centrifugation Following Space Flight

Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, <20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. One result of this study will be to characterize the variability (gain, asymmetry) in both otolithocular responses and motion perception during variable radius centrifugation, and measure the time course of postflight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

Wood, S. J.↗

The magnetic field and magnetospheric configuration of Uranus

A significant and unique planetary magnetic field discovered by Voyager 2 is presented. A large tilt of 58.6 deg of the magnetic-dipole axis from the rotation axis was found. Combined with a large offset of 0.3 RU of the magnetic dipole from the center of the planet, the moment of 0.23 gauss-RU3 leads to field magnitudes at the surface which vary widely between 0.1 and 1.0 gauss. A simple diagram illustrating the offset tilted dipole of Uranus and some field lines is shown. A more exact and accurate spherical-harmonic model of the planetary field, which includes both dipole and quadrupole moments, is derived. There exists a well-developed bipolar magnetic tail on the night side of the planet which rotates daily about the extended planet-sunline with Uranus because of the large obliquity of the Uranian rotation axis.

Ness, Norman F.↗

Spin State and Moment of Inertia of Venus

Fundamental properties of the planet Venus, such as its internal mass dis-tribution and variations in length of day, have remained unknown. We usedEarth-based observations of radar speckles tied to the rotation of Venus ob-tained in 2006–2020 to measure its spin axis orientation, spin precession rate,moment of inertia, and length-of-day variations. Venus is tilted by 2.6392±0.0008 degrees (1σ) with respect to its orbital plane. The spin axis precessesat a rate of 44.58±3.3 arcseconds per year (1σ), which gives a normalized mo-ment of inertia of 0.337±0.024 and yields a rough estimate of the size of thecore. The average sidereal day on Venus in the 2006–2020 interval is 243.0226±0.0013 Earth days (1σ). The spin period of the solid planet exhibits variationsof 61 ppm (∼20 minutes) with a possible diurnal or semidiurnal forcing. Thelength-of-day variations imply that changes in atmospheric angular momentumof at least∼4% are transferred to the solid planet.

Jean-Luc Margot↗

Modification of Eye Movements and Motion Perception during Off-Vertical Axis Rotation

Constant velocity Off-Vertical Axis Rotation (OVAR) imposes a continuously varying orientation of the head and body relative to gravity. The ensuing ocular reflexes include modulation of both torsional and horizontal eye movements as a function of the varying linear acceleration along the lateral plane, and modulation of vertical and vergence eye movements as a function of the varying linear acceleration along the sagittal plane. Previous studies have demonstrated that tilt and translation otolith-ocular responses, as well as motion perception, vary as a function of stimulus frequency during OVAR. The purpose of this study is to examine normative OVAR responses in healthy human subjects, and examine adaptive changes in astronauts following short duration space flight at low (0.125 Hz) and high (0.5 Hz) frequencies. Data was obtained on 24 normative subjects (14 M, 10 F) and 14 (13 M, 1F) astronaut subjects. To date, astronauts have participated in 3 preflight sessions (n=14) and on R+0/1 (n=7), R+2 (n= 13) and R+4 (n= 13) days after landing. Subjects were rotated in darkness about their longitudinal axis 20 deg off-vertical at constant rates of 45 and 180 deg/s, corresponding to 0.125 and 0.5 Hz. Binocular responses were obtained with video-oculography. Perceived motion was evaluated using verbal reports and a two-axis joystick (pitch and roll tilt) mounted on top of a two-axis linear stage (anterior-posterior and medial-lateral translation). Eye responses were obtained in ten of the normative subjects with the head and trunk aligned, and then with the head turned relative to the trunk 40 deg to the right or left of center. Sinusoidal curve fits were used to derive amplitude, phase and bias of the responses over several cycles at each stimulus frequency. Eye responses during 0.125 Hz OVAR were dominated by modulation of torsional and vertical eye position, compensatory for tilt relative to gravity. While there is a bias horizontal slow phase velocity (SPV), the modulation of horizontal and vergence SPV is negligible at this lower stimulus frequency. Eye responses during 0.5 Hz OVAR; however, are characterized by modulation of horizontal and vergence SPV, compensatory for translation in the lateral and sagittal planes, respectively. Neither amplitude nor bias velocities were significantly altered by head-on-trunk position. The phases of the ocular reflexes, on the other hand, shifted towards alignment with the head. During the lower frequency OVAR, subjects reported the perception of progressing along the edge of a cone. During higher frequency OVAR, subjects reported the perception of progressing along the edge of an upright cylinder. In contrast to the eye movements, the phase of both perceived tilt and translation motion is not altered by stimulus frequency. Preliminary results from astronaut data suggest that the ocular responses are not substantially altered by short-duration spaceflight. However, compared to preflight averages, astronauts reported greater amplitude of both perceived tilt and translation at low and high frequency, respectively, during early post-flight testing. We conclude that the neural processing to distinguish tilt and translation linear acceleration stimuli differs between eye movements and motion perception. The results from modifying head-on-trunk position are consistent with the modulation of ocular reflexes during OVAR being primarily mediated by the otoliths in response to the sinusoidally varying linear acceleration along the interaural and naso-occipital head axis. While the tilt and translation ocular reflexes appear to operate in an independent fashion, the timing of perceived tilt and translation influence each other. We conclude that the perceived motion path during linear acceleration in darkness results from a composite representation of tilt and translation inputs from both vestibular and somatosensory systems.

Wood, S. J.↗

Spatial Cognitive Performance During Adaptation to Conflicting Tilt-Translation Stimuli as a Sensorimotor Spaceflight Analog

The need to resolve new patterns of sensory feedback in altered gravitoinertial environments requires cognitive processes to develop appropriate reference frames for spatial orientation awareness. The purpose of this study was to examine deficits in spatial cognitive performance during adaptation to conflicting tilt-translation stimuli. Fourteen subjects were tilted within a lighted enclosure that simultaneously translated at one of 3 frequencies. Tilt and translation motion was synchronized to maintain the resultant gravitoinertial force aligned with the longitudinal body axis, resulting in a mismatch analogous to spaceflight in which the canals and vision signal tilt while the otoliths do not. Changes in performance on different spatial cognitive tasks were compared 1) without motion, 2) with tilt motion alone (pitch at 0.15, 0.3 and 0.6 Hz or roll at 0.3 Hz), and 3) with conflicting tilt-translation motion. The adaptation paradigm was continued for up to 30 min or until the onset of nausea. The order of the adaptation conditions were counter-balanced across 4 different test sessions. There was a significant effect of stimulus frequency on both motion sickness and spatial cognitive performance. Only 3 of 14 were able to complete the full 30 min protocol at 0.15 Hz, while 7 of 14 completed 0.3 Hz and 13 of 14 completed 0.6 Hz. There were no changes in simple visual-spatial cognitive tests, e.g., mental rotation or match-to-sample. There were significant deficits during 0.15 Hz adaptation in both accuracy and reaction time during a spatial reference task in which subjects are asked to identify a match of a 3D reoriented cube assemblage. Our results are consistent with antidotal reports of cognitive impairment that are common during sensorimotor adaptation with G-transitions. We conclude that these cognitive deficits stem from the ambiguity of spatial reference frames for central processing of inertial motion cues.

Kayanickupuram, A. J.↗