Search NASA⌕ Search

SEARCH · Search NASA

Results for “BOLTS - STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

BOLT II Forebody Surface Measurement Analysis

Surface impression molds of the nosetip/forebody interface, discrete tripping elements, and other surface imperfections were formed on the BOLT II flight vehicle prior to its launch in March 2022. The silicon-rubber molds cast on the interface between the nickel nosetip and the stainless steel forebody were measured using a 3D optical measurement system and a stylus profilometer and were evaluated for step direction and height. The step around the nosetip/forebody interface was found to vary in both magnitude and direction, but values were generally modest with most samples below 60 μm across the span and only two samples, both cast in the gutter, with step values larger than 100 μm. Impressions of the secondary-side tripping elements were strictly scanned with the optical device and similar methods were used to calculate trip height as step height. The measured centerline trip height was 2623 ±12 μm, while the leading-edge, quadrant 2 and 3, trip heights were 897 ±5 μm and 891 ±18 μm, respectively. Surface imperfections on the nose and forebody were also evaluated. Surface roughness values and spectra were estimated, and profiles were extracted across the imperfections to quantify the magnitude of those features.

Trip height↗

A nut-and-bolt assembly of the bimodular large progenitor botulinum neurotoxin complex

Botulinum neurotoxin serotype A (BoNT/A) is naturally produced by bacteria along with four nontoxic neurotoxin-associated proteins (NTNH, HA70, HA33, and HA17), forming a bimodular large progenitor toxin complex (L-PTC). The BoNT/A–NTNH complex protects the toxin from adverse environment, while the complex consisting of HA proteins facilitates toxin absorption during oral intoxication. How these two independent modules assemble into the L-PTC remains unclear. Here, we report the crystal structure of the BoNT/A–NTNH–HA70 complex at ~2.9-Å resolution. The structure reveals that the BoNT/A–NTNH complex is anchored into a concentric double β-barrel channel of trimeric HA70 through a short β-hairpin of NTNH (termed nLoop), resembling a nut-and-bolt attachment. We find that the nLoop of NTNH is strictly conserved across HA-containing BoNT complexes and that NTNH–HA70 binding is interchangeable among them. Furthermore, we demonstrate that the nLoop functions as a minimal motif enabling attachment of a protein-of-interest to the HA complex, with potential applications in oral biologics delivery.

Science & Technology - Other Topics↗

Analysis of Deformation and Fracture Mechanisms in the Harvested Low-Dose Baffle Former Bolt via Advanced Mechanical Tests

This report details the production of tensile specimens from in-service irradiated baffle former bolts (BFBs) and presents the results of a pilot in-situ SEM/EBSD test conducted at Oak Ridge National Laboratory’s Low Activation Materials Development and Analysis (LAMDA) facility. The SEM/EDS results confirmed that the material is AISI 316L steel, not AISI 347, and that no Nb addition was detected in several analyzed locations. EBSD analysis of the microstructure revealed in-grain misorientation gradients indicative of cold work, likely caused by material processing, and no retained ferrite was identified. During straining, dislocation channel formation was the primary deformation mechanism, with twinning also observed in favorably oriented grains at local strains as small as ~1.5%. No strain-induced phase instability was observed, likely due to the fact that the Ni and Cr content reached the upper limits for the 316L steel specification. Multiple microfracture events were observed during the tensile test. Fine strain-induced pores formed at the channel-grain boundary intersection points, while coarser microcracks were associated with non-metallic inclusions. Data analysis is ongoing, and additional tests are planned in the near future to provide more statistics and details.

36 MATERIALS SCIENCE↗

Computer vision-based rock bolt detection in orthomosaic imagery obtained in the Waste Isolation Pilot Plant underground facility

Assessing structural integrity of large underground tunnel facilities is often a time consuming and human-labor intensive task. Thus, research using various modes of sensing and automated detection of key structural components in mines is posed to aid in safety assessments and establishing overall structural health. We propose an approach utilizing off-the-shelf camera and lidar technology fixed to a custom sensing platform, image stitching techniques, fine-tuned object detection models, and specialized model-inference methods to automatically detect, count, and map roof bolts for assessment of structural safety in man-made underground tunnels. Results show a novel workflow for effective object counting in orthomosaic tunnel ceiling images generated from collections in GPS-denied mining environments. Additionally, we demonstrate effective fine-tuning of EfficientDet object detectors utilizing state-of-the-art image augmentation techniques known as the mosaic and mixup transformations. Our work is demonstrated on sensed data and imagery collected from the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) where miles of tunnel ceiling must be assessed for structural integrity.

42 ENGINEERING↗

Fundamentals of Solar PV Bolted Joint Loosening and Prevention

The photovoltaic (PV) industry has long reported anecdotal accounts of systems exhibiting intermittent or chronic fastener loosening, including joints that fail to maintain preload despite multiple re-tightening attempts. These occurrences are frequently, and often incorrectly, attributed to installer errors, vibration, or loading beyond design expectations (e.g., extreme weather events). Loose fasteners have serious implications and can significantly impact solar PV systems’ performance, reliability, and safety. However, effective bolted joint design and proper assembly practices can mitigate or eliminate loosening. Until the US Department of Energy’s Solar Energy Technologies Office (SETO) funded research on fasteners and solar PV structures, there was a notable gap in understanding the causes of loosening in solar PV systems.

14 SOLAR ENERGY↗

Comparison of release torques of tightened bolts in vacuum and air

Various combinations of stainless steel, mild steel, and aluminum bolt-nut couples are tightened to 60 lb-ft in partial vacuum and in air. Results are given for tests with and without two lubricants /a fluorosilicone and a sodium silicate bonded dry-film/.

Demorest, K. E.↗

Easy insert, easy release toggle bolt fastener

Releasable pin-type toggle bolt fastener is constructed so that, when positioned in hole, toggle action prevents its removal and locknut anchors it firmly in place. Fastener is easily removed by loosening locknut and retraction of toggle wings.

Kubokawa, C. C.↗