Easy insert, easy release toggle bolt fastener

Releasable pin-type toggle bolt fastener is constructed so that, when positioned in hole, toggle action prevents its removal and locknut anchors it firmly in place. Fastener is easily removed by loosening locknut and retraction of toggle wings.

Kubokawa, C. C.↗

Thermal conductance in a bolted joint.

The thermal contact resistance of a bolted joint is composed of two components: large scale constriction which is influenced by the extent of the interfacial pressure distribution and small scale constriction which is influenced by the magnitude of the local pressure. It is analytically shown how the roughness asperities at the contact surfaces of the joint affect these two constrictions but in opposite senses. The sum of the two effects, the total resistance, may increase or decrease with changing resistance and examples are given where an optimum roughness will minimize total joint resistance.

Roca, R. T.↗

ROUS bolt-tensioning monitor

Closed-loop feedback circuit system used to measure bolt tension. Advantages are its simplicity, higher accuracy, and potential low cost.

Heyman, J. S.↗

Reliability aspects of a composite bolted scarf joint

The design, fabrication, static test, and fatigue test of both tension and compression graphite-epoxy candidates for a wing splice representative of a next-generation transport aircraft was the objective of the reported research program. A single-scarf bolted joint was selected as the design concept. Test specimens were designed and fabricated to represent an upper-surface and a lower-surface panel containing the splice. The load spectrum was a flight-by-flight random-load history including ground-air-ground loads. The results of the fatigue testing indicate that, for this type of joint, the inherent fatigue resistance of the laminate is reflected in the joint behavior and, consequently, the rate of damage accumulation is very slow under realistic fatigue loadings.

Reed, D. L.↗

Ultrasonic extensometer measures bolt preload

Extensometer using ultrasonic pulse reflections to measure elongations in tightened belts and studs is much more accurate than conventional torque wrenches in application of specified preload to bolts and other threaded fasteners.

Daniels, C. M., Jr.↗

CW ultrasonic bolt tensioning monitor

A CW ultrasonic device is described for measuring frequency shifts of the peak of a mechanical resonance in a body. One application of the device is measuring the strain in a bolt, and other applications such as measuring the thickness of a body, measuring the depth of a flaw in a body, measuring the elongation of a body, and measuring changes in velocity of sound in a body. The body is connected, by means of a CW transducer, to electrical circuit means including a narrow band RF amplifier to form a closed loop feedback marginal oscillator that frequency locks the device to the peak of a mechanical resonance in the body. When the frequency of this peak changes, because of a physical change in the body, the frequency of the oscillator changes. The device includes an automatic frequency resonant peak tracker that produces a voltage that is related to a change in frequency of the oscillator. This voltage is applied to the RF amplifier to change the center of its frequency band to include the frequency of the peak and is a measure of the frequency shift.

Heyman, J. S.↗

Mechanical characterization of PMR-15 graphite/polyimide bolted joints

Data are presented for the static and viscoelastic performance of Celion 6000/PMR-15 graphite/polyimide composite belted joints over the 21 to 315 C temperature range. Two laminate configurations were obtained by sectioning a panel into subpanels oriented parallel and perpendicular to the laminate principal direction. Three replicates of each specimen geometry were tested at each of the test temperatures for the two laminate configurations, and failure load was defined as the maximum load attained as indicated by the load/deflection curve. Effects of strain-rate on strength and failure mode behavior were assessed at room temperature for strain rates of 0.002, 0.01, 0.10, and 1.00/s, and creep behavior was examined for the case of bearing deformations at temperatures of 21 and 177 C. Results are presented, including: (1) two distinct mechanisms were responsible for bearing failure and related to laminate configuration, (2) the + or - 45 deg plies carried the shearing load in composite bolted joints, and (3) the material exhibited strain-rate sensitivity which varied with laminate configuration.

Wilson, D. W.↗

An equation for bolt clampup relaxation in transient environments

An equation for bolt clampup relaxation for transient temperature-moisture (T-M) conditions was derived starting with a relaxation equation for steady-state conditions, and then using an incremental time approach that exploits the superposition principle for linear viscoelasticity. The resulting equation uses the initial T-M condition (at the time of clamping), the T-M history after clamping, and elastic clampup coefficients for temperature and moisture changes. For a given material and joint configuration, the clampup coefficients are constants that can be calculated by elastic analyses. The clampup equation was used to calculate the changes in clampup occurring in a T300/5208 graphite/epoxy joint exposed to a one-year history of temperature and moisture. Two cases were considered: one was a dry joint exposed to a relatively humid environment and the other was a nearly saturated joint exposed to an arid environment.

Shivakumar, K. N.↗

Bolt Inserts for Lightning Protection

Stainless steel bolt fasteners have adequate grounding paths for protection of structures against lightning strikes. Fasteners particularly useful in sections where insulating material required, such as thermal panels of external storage tank.

Hambrock, K. O.↗

Bonded and Bolted Graphite/Polyimide Composite Joints

Four types of high-temperature joints designed for control surfaces. Design, analysis, and testing performed to develop four types of graphite/polyimide bonded and bolted composite joints for lightly loaded control surfaces on advanced transportation systems that operate at temperatures up to 550 degrees F (288 degrees C).

Skoumal, D. E.↗

Lubricating Holes for Corroded Nuts and Bolts

Corroded fasteners taken apart more easily. Lubricating holes bored to thread from three of flats. Holes facilitate application of penetrating oil to help loosen nut when rusted onto bolt. Holes make it possible to apply lubricants and rust removers directly to more of thread than otherwise reachable.

Penn, B. G.↗