Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bagging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Numerical Model Development of a Variable-Geometry Attenuator Wave Energy Converter

Because the wave energy industry is still in its infancy, an optimal design for wave energy converters (WECs) has yet to be established; more work is needed to explore various cost-reduction pathways. The primary cost-reduction pathway considered for this work is the optimization of the geometric profile on an attenuator WEC to maximize power production while, at the same time, minimizing capital expenditures through the use of variable-geometry modules. In this investigation, the variable-geometry modules consist of inflatable bags placed on either side of a base central steel cylinder that would be inflated in low-moderate sea states to maximize power capture and then deflated in moderate-extreme sea states to minimize wave loading. The numerical model and simulation of the attenuator WEC were developed and completed using WEC-Sim, which is an open-source code that is appropriate for use in evaluating the dynamic response of the different WEC models in operational seas. The power production estimates were obtained from the Wave Energy Prize (WEP) sea states, which are representative of U. S. deployment sites, to calculate the average climate capture width that is used in the WEP ACE calculation. Preliminary capital expenditure costs were obtained assuming the base central steel cylinder mass was equal to the fluid displaced mass, minus the mass of the variable-geometry bags. The additional weight required to offset the additional buoyancy from the variable-geometry bags was assumed to come from the addition of seawater ballast. The variable-geometry attenuator model was found to have a similar power capture efficiency as a fixed-body model, but is expected to have a lower characteristic capital expenditure given its more streamlined profile, which demonstrates that variable-geometry modules may provide a realistic cost-reduction pathway to help design a more cost-competitive WEC.

50 EE - Wind and Water Power Program - Water (EE-4↗

Inflatable stretcher to transport patients

Inflatable plastic bag inside strong, inflexible outer bag facilitates emergency transport of seriously burned or disabled patients. When the bag is inflated the patient is completely immobilized and cushioned from external shock. Air for breathing, temperature controls and communications may be provided by appropriate plug-in connections.

Clark, C. C.↗

White blood cell counting system

The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.

Source record↗

Development of graphite/polyimide composites.

This paper covers the characterization of the HT-S/RS6234 graphite/polyimide system. Processing techniques for vacuum bag, vacuum bag-press augmented, and vacuum bag-autoclave augmented have been developed under sponsorship of the NASA Marshall Space Flight Center (MSFC). Preliminary design properties for the HT-S/RS6234 resin system were developed at -320, 75, and 600 F. The processing techniques and the materials developed during this program are all directly applicable to the fabrication of large structural components such as would be required for the space shuttle and other advanced space vehicles.

Stuckey, J. M.↗

Evaluation of Inorganic/Organic Separators

Thirty-six (36) experimental 40AH sealed silver-zinc cells were constructed during phase I of this two (2) phase program. These cells were divided into six (6) groups of six (6) cells each. Each group of six (6) cells was evenly divided into two batches of three (3) cells each. Groups 1 through 4 each featured a different inorganic filler material in the slurry used to coat the separator substrate. Groups 5 and 6 featured an alternate method of separator bag construction. With the exception of the various separator materials, the parts and processes used to produce these thirty-six (36) cells were the same as those used to make the HR40-7 cell. The two (2) batches of cells in each cell group differed only in the lots of solutions and other separator slurry components used. Each cell was given two formation charge/discharge cycles prior to being shipped to NASA Lewis Research Center. Phase II of the program consisted of constructing another thirty-six (36) 40AH experimental cells in six (6) groups of six (6) cells each. Each group was distinguished by the type of precoated separator material used to fabricate separator bags. A new method of separator bag construction was used in this phase of the program. These cells were given two (2) formation cycles and shipped to NASA Lewis Research Center.

Donnel, C. P., III↗

System for and method of freezing biological tissue

Biological tissue is frozen while a polyethylene bag placed in abutting relationship against opposed walls of a pair of heaters. The bag and tissue are cooled with refrigerating gas at a time programmed rate at least equal to the maximum cooling rate needed at any time during the freezing process. The temperature of the bag, and hence of the tissue, is compared with a time programmed desired value for the tissue temperature to derive an error indication. The heater is activated in response to the error indication so that the temperature of the tissue follows the desired value for the time programmed tissue temperature. The tissue is heated to compensate for excessive cooling of the tissue as a result of the cooling by the refrigerating gas. In response to the error signal, the heater is deactivated while the latent heat of fusion is being removed from the tissue while the tissue is changing phase from liquid to solid.

Williams, T. E.↗

Soft container for explosive nuts

Flexible fabric fits over variety of assembly shapes to contain debris produced by detonations or safety tests. Bag material is woven multifilament polyamide or aramid. Belt loops hold bag to clamp. Ring supports explosive nut structure and detonator wires, and after nut is mounted, bag and clamp are slipped over ring and fastened.

Glenn, D. C.↗

Simple Regulator For Positive-Pressure Glove Box

Weighted, inflated bag regulates pressure in positive-pressure glove box such as those used to manipulate samples in atmosphere isolated from such contaminations in open air as moisture or oxygen. Weight atop the inflated bag rises and falls as gas flows into and out of bag from glove box. Positive pressure relative to surroundings pushes gloves outward when not being used. To manipulate items in box, technician forces gloves inside. Sensitive materials manipulated in dry or inert atmosphere without danger of overpressure when technician inserts hands in gloves, or of underpressure - and inward leakage of air - when technician draws hands out of gloves. Replaces elaborate system of pressure-activated valves. Quieter, cheaper, and more reliable.

Shlichta, Paul J.↗

Lunar surface vehicle model competition

During Fall and Winter quarters, Georgia Tech's School of Mechanical Engineering students designed machines and devices related to Lunar Base construction tasks. These include joint projects with Textile Engineering students. Topics studied included lunar environment simulator via drop tower technology, lunar rated fasteners, lunar habitat shelter, design of a lunar surface trenching machine, lunar support system, lunar worksite illumination (daytime), lunar regolith bagging system, sunlight diffusing tent for lunar worksite, service apparatus for lunar launch vehicles, lunar communication/power cables and teleoperated deployment machine, lunar regolith bag collection and emplacement device, soil stabilization mat for lunar launch/landing site, lunar rated fastening systems for robotic implementation, lunar surface cable/conduit and automated deployment system, lunar regolith bagging system, and lunar rated fasteners and fastening systems. A special topics team of five Spring quarter students designed and constructed a remotely controlled crane implement for the SKITTER model.

Source record↗

Structural evaluation of curved stiffened composite panels fabricated using a THERM-Xsm process

The use of composites in aircraft structures is often limited by material and manufacturing costs which, for some designs and applications, are prohibitively high. To increase the frequency of application of composites in primary airframe components alternative manufacturing processes are sought that reduce cost and/or enhance structural efficiency. One alternative process involves the use of THERM-Xsm as the pressure transfer medium during autoclave curing. THERM-Xsm, a silicon-based flow able polymer which behaves like a liquid under autoclave presssure, transmits quasi-hydrostatic pressure to all contacting surfaces of the part to be cured. Once the autoclave pressure is relieved, THERM-Xsm reverts back to the powdery solid state and can be reused many times. The THERM-Xsm process to be evaluated is depicted and consists of (1) enclosing the tool and part to be cured by a set of frames that create a box, (2) pouring THERM-Xsm powder onto the part and filling the box, and (3) placing a vacuum bag over the box assembly. In this program, a separating non-porous film (Teflon) was placed between the part to be cured and THERM-Xsm powder to avoid any contamination. The use of THERM-Xsm has two significant advantages over conventional manufacturing procedures. First, it eliminates complicated hard tooling since it guarantees uniform pressure transfer and thus, good compaction at complex structural details (such as frame-stiffener intersections and corners). Second, it greatly simplifies vacuum bagging, since once the part to be cured is covered by THERM-Xsm powder, the vacuum bag need only conform to a relatively flat shape reducing significantly the number of pleats required. A program is on-going at Sikorsky Aircraft to evaluate the structural performance of complex composite fuselage structures made with this THERM-Xsm process and to quantify the impact of THERM-Xsm on manufacturing labor hours and cost. The program involves fuselage panel optimization analysis, a building block test program where structural details representative of the full-scale article are analyzed and tested, and static and fatigue test/analysis of the full-scale test articles. The main results of this program are reported.

Kassapoglou, Christos↗

Thermographic Analysis of Composite Cobonds on the X-33

The methods utilized to perform an infrared thermography inspection of the bondline of structural reinforcing caps on X-33 liquid hydrogen (LH2) tank during the manufacture are described in this presentation. A total of thirty-six caps were bonded to the tank using a wet cobond process with vacuum bagging and low temperature curing. The thermal map of each bondline was acquired through the vacuum bag by applying heat to the cap and then viewing it during cool down. Poorly bonded regions, or voids, were characterized by localized hot spots in the thermal image. These regions were marked on the tank by referring to a live thermal image, then hand massaged in an attempt to remove the entrapped air. The cap was then reinspected and, if it was determined that the entrapped air could not be removed, the cap was removed and the adhesive cleaned away before it cured. Measures were then taken to better match the surface of the cap to the tank and the process repeated. After the bondline had cured sufficiently to allow vacuum bag removal, a "flash heating" thermographic Investigation was performed to verify that the cap had bonded properly to the tank. Any regions that had opened up after the preliminary inspection were marked and filled by drilling small holes in the cap and injecting resin. A final inspection was then performed to ensure the quality of the bondline.

Russell, Samual S.↗

My Big Wall

It was June and I was in Yosemite National Park in California, 2,000-feet off the ground. I was climbing El Capitan, a majestic 3,000-foot high, mile-wide granite monolith--one of the most sought after and spectacular rock climbs in the world. After three days of climbing on its sheer face, and having completed the most difficult part of the route, my partner and I were heading down. A thunderstorm lasting all night and into the morning had soaked our tiny perch and all our worldly possessions. We began rappelling down the vertical wall by sliding to the ends of two 50meter ropes tied together and looped through a set of fixed rings bolted into the rock. At the end of the ropes was another rappel station consisting of a set of rings, placed by previous climbers for retreating parties, which we used to anchor ourselves to the rock face. We then pulled the ropes down from the rings above, threaded the ones in front of our noses and started down another rope length. Everything we brought up for our five-day climb to the summit we had to bring back down with us: ropes, climbing gear of every sort, sleeping bags, extra clothes, food, water, and other essentials. All this we either stuffed into a haul bag (an oversized reinforced duffel bag) or slung over our shoulders. The retreat was slow and methodical, akin to a train backing down a mountain, giving me ample time to think. My situation made me think about my work, mostly, about all the projects I have managed, or been involved in managing. As a NASA project manager, I have worked on a number of successful projects. I have also been involved in a number of projects I never saw the end of. I thought about all the projects I transferred off of for other opportunities, projects that were in full stride and ran out of funding, and ones put on the shelf because they would not meet a flight date. Oh yes, I have had many success, to be sure, or I would have burned out years ago. Lessons from both the successful and not-so-successful projects have taught me valuable lessons, but it has always been the failures where I've learned the most.

Espinosa, Paul S.↗

Reflective Packaging

The aluminized polymer film used in spacecraft as a radiation barrier to protect both astronauts and delicate instruments has led to a number of spinoff applications. Among them are aluminized shipping bags, food cart covers and medical bags. Radiant Technologies purchases component materials and assembles a barrier made of layers of aluminized foil. The packaging reflects outside heat away from the product inside the container. The company is developing new aluminized lines, express mailers, large shipping bags, gel packs and insulated panels for the building industry.

Source record↗

Analysis of the Effect of Surface Modification on Polyimide Composites Coated with Erosion Resistant Materials

The aim of this research is to enhance performance of composite coatings through modification of graphite-reinforced polyimide composite surfaces prior to metal bond coat/ hard topcoat application for use in the erosive and/or oxidative environments of advanced engines. Graphite reinforced polyimide composites, PMR-15 and PMR-II-50, formed by sheet molding and pre-pregging will be surface treated, overlaid with a bond coat and then coated with WC-Co. The surface treatment will include cleaning, RF plasma or ultraviolet light- ozone etching, and deposition of SiO(x) groups. These surface treatments will be studied in order to investigate and improve adhesion and oxidation resistance. The following panels were provided by NASA-Glenn Research Center(NASA-GRC): Eight compression molded PMR-II-50; 6 x 6 x 0.125 in. Two vacuum-bagged PMR-II-50; 12 x 12 x 0.125 in. Eight compression molded PMR-15; 6 x 6 x 0.125 in. One vacuum-bagged PMR-15; 12 x 12 x 0.125 in. All panels were made using a 12 x 12 in. T650-35 8HS (3K-tow) graphite fabric. A diamond-wafering blade, with deionized water as a cutting fluid, was used to cut PMR-II-50 and PMR-15 panels into 1 x 1 in. pieces for surface tests. The panel edges exhibiting delamination were used for the preliminary surface preparation tests as these would be unsuitable for strength and erosion testing. PMR-15 neat resin samples were also provided by NASA GRC. Surface profiles of the as-received samples were determined using a Dektak III Surface profile measuring system. Two samples of compression molded PMR-II-50 and PMR-15, vacuum-bagged PMR-II-50 and PMR-15 were randomly chosen for surface profile measurement according to ANSI/ASME B46.1. Prior to each measurement, the samples were blasted with compressed air to remove any artifacts. Five 10 mm-long scans were made on each sample. The short and long wavelength cutoff filter values were set at 100 and 1000 m, diamond stylus radius was 12.5 microns. Table 1 is a summary of the arithmetic average roughness (Ra) and waviness (Wa) for the composite surfaces.

Ndalama, Tchinga↗

Processing and Properties of a Phenolic Composite System

Phenolic resin systems generate water as a reaction by-product via condensation reactions during curing at elevated temperatures. In the fabrication of fiber reinforced phenolic resin matrix composites, volatile management is crucial in producing void-free quality laminates. A commercial vacuum-bag moldable phenolic prepreg system was selected for this study. The traditional single-vacuum-bag (SVB) process was unable to manage the volatiles effectively, resulting in inferior voidy laminates. However, a double vacuum bag (DVB) process was shown to afford superior volatile management and consistently yielded void-free quality parts. The DVB process cure cycle (temperature /pressure profiles) for the selected composite system was designed, with the vacuum pressure application point carefully selected, to avoid excessive resin squeeze-outs and achieve the net shape and target resin content in the final consolidated laminate parts. Laminate consolidation quality was characterized by optical photomicrography for the cross sections and measurements of mechanical properties. A 40% increase in short beam shear strength, 30% greater flexural strength, 10% higher tensile and 18% higher compression strengths were obtained in composite laminates fabricated by the DVB process.

Hou, Tan-Hung↗

Development of an Inline Urine Monitoring System for the International Space Station

Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

Broyan, James Lee, Jr.↗

Development of an In-line Urine Monitoring System for the International Space Station

Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

Broyan, James Lee, Jr.↗

Salience Assignment for Multiple-Instance Regression

We present a Multiple-Instance Learning (MIL) algorithm for determining the salience of each item in each bag with respect to the bag's real-valued label. We use an alternating-projections constrained optimization approach to simultaneously learn a regression model and estimate all salience values. We evaluate this algorithm on a significant real-world problem, crop yield modeling, and demonstrate that it provides more extensive, intuitive, and stable salience models than Primary-Instance Regression, which selects a single relevant item from each bag.

regression↗