Search NASASearch

SEARCH · Search NASA

Results for “Battery Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Assessment of the pharmacodynamics of intranasal, intravenous and oral scopolamine

Space motion sickness is an important issue in the space medical sciences program. One of the objectives of the ongoing clinical experimental protocol Pharmacokinetics of Intranasal Scopolamine in Normal Subjects is to evaluate the pharmacodynamics of scopolamine using salivary flow rate and pH profiles and cognitive performance tests as pharmacodynamic parameters. Normal volunteers collected saliva and performed the NTI Multiresource Performance Battery tests at designed time intervals to establish control saliva flow rates, salivary pH profiles, and the characteristics of the learning curve for the performance program under normal conditions. In the clinical part of the study, saliva samples and performance test scores are collected from healthy nonsmoking subjects after receiving a single 0.4 mg dose of either intranasal, intravenous, or oral scopolamine.

Tietze, Karen J.

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood

Operationally Responsive Space Standard Bus Battery Thermal Balance Testing and Heat Dissipation Analysis

The focus of this paper will be on the thermal balance testing for the Operationally Responsive Space Standard Bus Battery. The Standard Bus thermal design required that the battery be isolated from the bus itself. This required the battery to have its own thermal control, including heaters and a radiator surface. Since the battery was not ready for testing during the overall bus thermal balance testing, a separate test was conducted to verify the thermal design for the battery. This paper will discuss in detail, the test set up, test procedure, and results from this test. Additionally this paper will consider the methods taken to determine the heat dissipation of the battery during charge and discharge. It seems that the heat dissipation for Lithium Ion batteries is relatively unknown and hard to quantify. The methods used during test and the post test analysis to estimate the heat dissipation of the battery will be discussed.

Marley, Mike

Cycle life status of SAFT VOS nickel-cadmium cells

The SAFT prismatic VOS Ni-Cd cells have been flown in geosynchronous orbit since 1977 and in low earth orbit since 1983. Parallel cycling tests are performed by several space agencies in order to determine the cycle life for a wide range of temperature and depth of discharge (DOD). In low Earth orbit (LEO), the ELAN program is conducted on 24 Ah cells by CNES and ESA at the European Battery Test Center at temperatures ranging from 0 to 27 C and DOD from 10 to 40 percent. Data are presented up to 37,000 cycles. One pack (X-80) has achieved 49,000 cycles at 10 C and 23 percent DOD. The geosynchronous orbit simulation of a high DOD test is conducted by ESA on 3 batteries at 10 C and 70, 90, and 100 percent DOD. Thirty-one eclipse seasons are completed, and no signs of degradation have been found. The Air Force test at CRANE on 24 Ah and 40 Ah cells at 20 C and 80 percent DOD has achieved 19 shadow periods. Life expectancy is discussed. The VOS cell technology could be used for the following: (1) in geosynchronous conditions--15 yrs at 10-15 C and 80 percent DOD; and (2) in low earth orbit--10 yrs at 5-15 C and 25-30 percent DOD.

Goualard, Jacques

Web-Based Programs Assess Cognitive Fitness

The National Space Biomedical Research Institute, based in Houston and funded by NASA, began funding research for Harvard University researchers to design Palm software to help astronauts monitor and assess their cognitive functioning. The MiniCog Rapid Assessment Battery (MRAB) was licensed by the Criteria Corporation in Los Angeles and adapted for Web-based employment testing. The test battery assesses nine different cognitive functions and can gauge the effect of stress-related deficits, such as fatigue, on various tasks. The MRAB can be used not only for pre-employment testing but also for repeat administrations to measure day-to-day job readiness in professions where alertness is critical.

Source record

Miniaturize the Redox Flow Battery for Accelerated Materials Discovery and Development

Redox flow batteries are a promising technology for grid-scale energy storage. The aqueous organic redox flow battery is of particular interest for its potentially low material cost and sustainability. Developing novel organic active material for flow battery electrolytes typically entails molecular engineering toward desired properties, necessitating organic synthesis. In a research laboratory setting, the synthesis of specifically designed organic molecules featuring targeted functional groups is time and resources intensive. In the past, synthesizing materials required for battery testing has often required gram-scale production, presenting considerable constraints on the pace of novel organic material discovery. In this report, we introduce a miniaturized cell design that mandates only milligram-scale material synthesis while yielding testing outcomes equivalent or superior to those reported with other commercially available or homemade flow cells in the literature. The test results under various pH conditions validate the scale-down strategy to accelerate the flow battery material discovery and development using the newly designed mini cell. This approach offers researchers an efficient means to notably reduce the time and resources required to develop novel materials for flow batteries.

25 ENERGY STORAGE

Battery charge control with temperature compensated voltage limit

Battery charge control for orbiting spacecraft with mission durations from three to ten years, is a critical design feature that is discussed. Starting in 1974, the General Electric Space Systems Division designed, manufactured and tested battery systems for six different space programs. Three of these are geosynchronous missions, two are medium altitude missions and one is a near-earth mission. All six power subsystems contain nickel cadmium batteries which are charged using a temperature compensated voltage limit. This charging method was found to be successful in extending the life of nickel cadmium batteries in all three types of earth orbits. Test data and flight data are presented for each type of orbit.

Thierfelder, H. E.

Life test of 50 AH NiH2 battery

Life cycle testing on a battery is reported. The cells were built in 1975, put into battery in 1976, and flown in 1977 in low Earth orbit.

Warnoc, D. H.

The final days of Solar Max - Lessons learned from engineering evaluation tests

End-of-life engineering evaluation tests were performed on Solar Max between October and November 1989. The tests included four-wheel control law operation; reaction wheel rundowns; modular power subsystem standard power regulator unit voltage-temperature level tests; battery rundown/2nd plateau determination; high gain antenna retraction and jettison; and solar array jettison. This paper presents these tests, their results, and the lessons learned from them.

Donnelly, Michael L.

The Long-Term Performance of SONY Small Batteries without Cell-Balancing

This viewgraph presentation describes the investigation of individual cell voltage dispersion under LEO and GEO cycling profiles. The contents cover: 1) Background; 2) Test Outline; 3) Single String Test Battery; 4) Goddard Space Flight Center (GSFC) 5Ah Battery; 5) Impedance; 6) Conclusions.

Pearson, Chris

Unimpaired Neuro-Adaptive Plasticity in an Elderly Astronaut

Quantitative analyses of a 77 year old astronaut's balance control performances on a standardized test battery revealed few differences between his neuro-adaptive responses to space flight and those of a group of younger astronauts tested following missions of similar duration. This finding suggests that the physiological changes associated with age do not necessarily impair adaptive plasticity in the human following removal and subsequent reintroduction of gravity.

Paloski, William H.

Physiological Factors Contributing to Postflight Changes in Functional Performance

Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objectives of the FTT are to: Develop a set of functional tasks that represent critical mission tasks for Constellation. Determine the ability to perform these tasks after flight. Identify the key physiological factors that contribute to functional decrements. Use this information to develop targeted countermeasures. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers will perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data will be collected on R+0 (Shuttle only), R+1, R+6 and R+30. Using a multivariate regression model we will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

Bloomberg, J. J.

Defining the Physiological Factors that Contribute to Postflight Changes in Functional Performance

Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objective of the FTT is to identify the key underlying physiological factors that contribute to performance of functional tests that are representative of critical mission tasks. This study will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on R+0 (Shuttle only), R+1, R+6 and R+30.

Bloomberg, J. J.

Vestibular plasticity following orbital spaceflight: recovery from postflight postural instability

Results of previous studies suggested that the vestibular mediated postural instability observed in astronauts upon return to earth from orbital spaceflight may be exacerbated by an increased weighting of visual inputs for spatial orientation and control of movement. This study was performed to better understand the roles of visual and somatosensory contributions to recovery of normal sensori-motor postural control in returning astronauts. Preflight and postflight, 23 astronaut volunteers were presented randomly with three trials of six sensory organization test (SOT) conditions in the EquiTest system test battery. Sagittal plane center-of-gravity (COG) excursions computed from ground reaction forces were significantly higher on landing day than preflight for those test conditions presenting sway-referenced visual and/or somatosensory orientation cues. The ratio of summed peak-to-peak COG sway amplitudes on the two sway-referenced vision tests (SOTs 3 + 6) compared to the two eyes closed tests (SOTs 2 + 5) was increased on landing day, indicating an increased reliance on visual orientation cues for postural control. The ratio of peak-to-peak COG excursions on sway-referenced surfaces (SOTs 4, 5 & 6) to an earth fixed support surfaces (SOTs 1, 2 & 3) increased even more after landing suggesting primary reliance on somatosensory orientation cues for recovery of postflight postural stability. Readaptation to sway-referenced support surfaces took longer than readaptation to sway-referenced vision. The increased reliance on visual and somatosensory inputs disappeared in all astronauts 4-8 days following return to earth.

NASA Program Space Physiology and Countermeasures

NiCd cell reversals during reconditioning

An accelerated battery test with 15 periods of cell reversals during reconditioning was performed. The nature and extent of hydrogen generation was examined, and the effects of reversals on battery performance were determined.

Hwang, W.

An Update on the Lithium-Ion Cell Low-Earth-Orbit Verification Test Program

A Lithium-Ion Cell Low-Earth-Orbit Verification Test Program is being conducted by NASA Glenn Research Center to assess the performance of lithium-ion (Li-ion) cells over a wide range of low-Earth-orbit (LEO) conditions. The data generated will be used to build an empirical model for Li-ion batteries. The goal of the modeling will be to develop a tool to predict the performance and cycle life of Li-ion batteries operating at a specified set of mission conditions. Using this tool, mission planners will be able to design operation points of the battery system while factoring in mission requirements and the expected life and performance of the batteries. Test conditions for the program were selected via a statistical design of experiments to span a range of feasible operational conditions for LEO aerospace applications. The variables under evaluation are temperature, depth-of-discharge (DOD), and end-of-charge voltage (EOCV). The baseline matrix was formed by generating combinations from a set of three values for each variable. Temperature values are 10 C, 20 C and 30 C. Depth-of-discharge values are 20%, 30% and 40%. EOCV values are 3.85 V, 3.95 V, and 4.05 V. Test conditions for individual cells may vary slightly from the baseline test matrix depending upon the cell manufacturer s recommended operating conditions. Cells from each vendor are being evaluated at each of ten sets of test conditions. Cells from four cell manufacturers are undergoing life cycle tests. Life cycling on the first sets of cells began in September 2004. These cells consist of Saft 40 ampere-hour (Ah) cells and Lith ion 30 Ah cells. These cells have achieved over 10,000 cycles each, equivalent to about 20 months in LEO. In the past year, the test program has expanded to include the evaluation of Mine Safety Appliances (MSA) 50 Ah cells and ABSL battery modules. The MSA cells will begin life cycling in October 2006. The ABSL battery modules consist of commercial Sony hard carbon 18650 lithium-ion cells configured in series and parallel combinations to create nominal 14.4 volt, 3 Ah packs (4s-2p). These modules have accumulated approximately 3000 cycles. Results on the performance of the cells and modules will be presented in this paper. The life prediction and performance model for Li-ion cells in LEO will be built by analyzing the data statistically and performing regression analysis. Cells are being cycled to failure so that differences in performance trends that occur at different stages in the life of the cell can be observed and accurately modeled. Cell testing is being performed at the Naval Surface Warfare Center in Crane, IN.

Reid, Concha M.

Charge Efficiency Tests of Lead/Acid Batteries

Current, voltage, and gas evolution measured during charge/discharge cycles. Series of standarized tests for evaluating charging efficiency of lead/acid storage batteries described in report. Purpose of tests to provide information for design of battery charger that allows maximum recharge efficiency for electric-vehicle batteries consistent with other operating parameters, such as range, water loss, and cycle life.

Rowlette, J. J.