Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam code development & simulation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Collaborative Research: A Model of Partially Ionized Plasma Flows with Kinetic Treatment of Neutral Atoms and Nonthermal Ions

Interactions of flows of partially ionized, magnetized plasma are frequently accompanied by the presence of both thermal and non-thermal (pickup) ion components. Such interactions cannot be modeled using traditional MHD equations and require more advanced approaches to treat them. If a nonthermal component of ions is formed due to charge exchange and collisions between the thermal (core) ions and neutrals, it experiences the action of magnetic field, its distribution function is isotropized, and it soon acquires the velocity of the ambient plasma without being thermodynamically equilibrated. This situation, e. g., takes place in the outer heliosphere –- the part of interstellar space beyond the solar system whose properties are determined by the solar wind interaction with the local interstellar medium. This is also possible in laboratory, at million degrees and above, when plasma is conducting electricity far too well, which makes Ohmic heating ineffective. To attain the target temperatures one needs additional heating eventually playing a dominant role. Among such sources is a so-called neutral particle beam heating. This is a wide-spread technique (Joint European Torus and International Thermonuclear Experimental Reactor experiments) based on the injection of powerful beams of neutral atoms into ohmically preheated plasma. In this project we have investigated the energy and density separation between the thermal and nonthermal components in the solar wind and interstellar plasmas. A new model has been developed in which we solve the ideal MHD equations for mixture of all ions and the kinetic Boltzmann equation to describe the transport of neutral atoms. As a separate capability, we can treat the flow of neutral atoms in a multi-component fashion, where neutral atoms born in each thermodynamically distinct region are governed by the Euler gas dynamic equations. We also describe the behavior of pickup ions either kinetically, using the Fokker--Planck equation, or as a separate fluid. Our numerical simulations have demonstrated that pickup ions play a major role in the interaction of the solar wind and (partially ionized) interstellar medium plasmas. Our teams have investigated the stability of the surface (the heliopause) that separates the solar wind from the local interstellar medium, the transport of galactic cosmic rays, the properties of the heliotail flow, and modifications to the bow wave in front of the heliopause due to charge exchange between the neutral H atoms born in the solar wind and interstellar ions. Modeling results have been validated against observational data, such as obtained by the Interstellar Boundary Explorer (IBEX), and made it possible to shed light on the structure of energetic neutral atom maps created by this spacecraft.. We have also demonstrated that charge-exchange modulated heliosphere is a source of anisotropy of the multi-TeV cosmic ray flux observed in a number of Earth-bound air shower experiments. Newly developed codes are implemented within a Multi-Scale Fluid-Kinetic Simulation Suite (MS-FLUKSS), a publicly available code being developed by our team for over 12 years. MS-FLUKSS scales well up to 160,000 computing cores and has been ported on major supercomputers in the country. Efficient parallelization and data choreography in the continuum simulation modules are provided by Chombo, an adaptive mesh refinement framework managed by Phillip Colella's team at LBNL. We have implemented in-house, hybrid (MPI+OpenMP) parallelization of the kinetic modules that solve the Boltzmann equation with a Monte Carlo method. Currently, the kinetic modules are being rewritten to take advantage of the modern CPU-GPU supercomputer architecture. The scope of the project allowed us to enhance plasma research and education in such broad, multidisciplinary field as physics of partially ionized plasma and its application to space physics and fusion science. Besides the impact on the modeling of complex physical systems, our approach to computational resource management for complex codes utilizing multiple algorithm technologies appears to be a major advance on current approaches. The development of sophisticated resource management will be essential for all future modeling efforts that incorporate a diversity of scales and physical processes. Our effort provided leadership in promoting computational science and plasma physics within the UAH and FIT campuses and, through the training of a broad spectrum of scientists and engineers, fostering new technologies across the country.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collaborative Research: A Model of Partially Ionized Plasma Flows with Kinetic Treatment of Neutral Atoms and Nonthermal Ions

Interactions of flows of partially ionized, magnetized plasma are frequently accompanied by the presence of both thermal and non-thermal (pickup) ion components. Such interactions cannot be modeled using traditional MHD equations and require more advanced approaches to treat them. If a nonthermal component of ions is formed due to charge exchange and collisions between the thermal (core) ions and neutrals, it experiences the action of magnetic field, its distribution function is isotropized, and it soon acquires the velocity of the ambient plasma without being thermodynamically equilibrated. This situation, e. g., takes place in the outer heliosphere - the part of interstellar space beyond the solar system whose properties are determined by the solar wind interaction with the local interstellar medium. This is also possible in laboratory, at million degrees and above, when plasma is conducting electricity far too well, which makes Ohmic heating ineffective. To attain the target temperatures one needs additional heating eventually playing a dominant role. Among such sources is a so-called neutral particle beam heating. This is a wide-spread technique (Joint European Torus and International Thermonuclear Experimental Reactor experiments) based on the injection of powerful beams of neutral atoms into ohmically preheated plasma. In this project we have investigated the energy and density separation between the thermal and nonthermal components in the solar wind and interstellar plasmas. A new model has been developed in which we solve the ideal MHD equations for mixture of all ions and the kinetic Boltzmann equation to describe the transport of neutral atoms. As a separate capability, we can treat the flow of neutral atoms in a multi-component fashion, where neutral atoms born in each thermodynamically distinct regions are governed by the Euler gas dynamic equations. We also describe the behavior of pickup ions either kinetically, using the Fokker–Planck equation, or as a separate fluid. Our numerical simulations have demonstrated that pickup ions play a major role in the interaction of the solar wind and (partially ionized) interstellar medium plasmas. Our teams have investigated the stability of the surface (the heliopause) that separates the solar wind from the local interstellar medium, the transport of galactic cosmic rays, the properties of the heliotail flow, and modifications to the bow wave in front of the heliopause due to charge exchange between the neutral H atoms born in the solar wind and interstellar ions. Modeling results have been validated against observational data, such as obtained by the Interstellar Boundary Explorer (IBEX), and made it possible to shed light on the structure of energetic neutral atom maps created by this spacecraft.. We have also demonstrated that charge-exchange modulated heliosphere is a source of anisotropy of the multi-TeV cosmic ray flux observed in a number of Earth-bound air shower experiments. Newly developed codes are implemented within a Multi-Scale Fluid-Kinetic Simulation Suite (MS-FLUKSS), a publicly available code being developed by our team for over 12 years. MS-FLUKSS scales well up to 160,000 computing cores and has been ported on major supercomputers in the country. Efficient parallelization and data choreography in the continuum simulation modules are provided by Chombo, an adaptive mesh refinement framework managed by Phillip Colella’s team at LBNL. We have implemented in-house, hybrid (MPI+OpenMP) parallelization of the kinetic modules that solve the Boltzmann equation with a Monte Carlo method. Currently, the kinetic modules are being rewritten to take advantage of the modern CPU-GPU supercomputer architecture. The scope of the project allowed us to enhance plasma research and education in such broad, multidis- ciplinary field as physics of partially ionized plasma and its application to space physics and fusion science. Besides the impact on the modeling of complex physical systems, our approach to computational resource management for complex codes utilizing multiple algorithm technologies appears to be a major advance on current approaches. The development of sophisticated resource management will be essential for all future modeling efforts that incorporate a diversity of scales and physical processes. Our effort provided leadership in promoting computational science and plasma physics within the UAH and FIT campuses and, through the training of a broad spectrum of scientists and engineers, foster new technologies across the country.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-throughput ion irradiation of additively manufactured compositionally complex alloys

Several advanced nuclear reactor designs promise efficiency and safety improvements over the current reactor fleet but are limited by the current set of ASME code-qualified materials. Novel alloys including high-entropy alloys (HEAs), and more broadly compositionally complex alloys (CCAs), have shown promising irradiation-tolerance. However, the vast range of alloy compositions adds to an already time-consuming alloy development process. In this study, to accelerate the development of novel alloys for nuclear applications, a high-throughput (HTP) methodology has been employed. Additive manufacturing has been used to produce a compositional array of unary, binary, ternary, and quaternary alloys, including several CCAs, which span the Cr-Fe-Mn-Ni composition space. Additionally, the compositional array was homogenized at 1000°C for 24 hours and each sample was irradiated using 4-MeV Ni2+ ions at room temperature to a peak damage of 50 dpa, as estimated using SRIM, at the University of Wisconsin Ion Beam Laboratory. A custom XY stage was built to accommodate the large compositional array and half of each sample was masked during irradiation enabling both the irradiated and unirradiated properties of each alloy to be characterized side-by-side. Each alloy was characterized using X-ray fluorescence (XRF), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and nanoindentation. CALPHAD simulations spanning the entire Cr-Fe-Mn-Ni composition space at 1000°C were performed to compare predicted equilibrium phases with phases identified experimentally from the unirradiated regions of each alloy. Nanoindentation measurements indicate radiation-induced hardening ranging from ~1-1.5 GPa in each of Cr-Fe-Mn-Ni CCAs, which is relatively insensitive to modest changes in alloy composition and comparable to hardening observed in neutron irradiated Cr-Fe-Mn-Ni CCAs in the literature. Overall, a substantial time savings was realized by employing HTP synthesis, irradiation, and characterization in this study compared to conventional techniques, the implications of which are discussed.

36 MATERIALS SCIENCE↗

SU-E-T-64: CG-Based Radiation Therapy Simulator with Physical Modeling for Avoidance of Collisions Between Gantry and Couch Or Patient

Purpose: It is time-consuming and might cause re-planning to check couch-gantry and patient-gantry collisions on a radiotherapy machine when using couch rotations for non-coplanar beam angles. The aim of this study was to develop a computer-graphics (CG)-based radiation therapy simulator with physical modeling for avoidance of collisions between gantry and couch or patient on a radiotherapy machine. Methods: The radiation therapy simulator was three-dimensionally constructed including a radiotherapy machine (Clinac iX, Varian Medical Systems), couch, and radiation treatment room according to their designs by using a physical-modeling-based computer graphics software (Blender, free and open-source). Each patient was modeled by applying a surface rendering technique to their planning computed tomography (CT) images acquired from 16-slice CT scanner (BrightSpeed, GE Healthcare). Immobilization devices for patients were scanned by the CT equipment, and were rendered as the patient planning CT images. The errors in the collision angle of the gantry with the couch or patient between gold standards and the estimated values were obtained by fixing the gantry angle for the evaluation of the proposed simulator. Results: The average error of estimated collision angles to the couch head side was -8.5% for gantry angles of 60 to 135 degree, and -5.5% for gantry angles of 225 to 300 degree. Moreover, the average error of estimated collision angles to the couch foot side was -1.1% for gantry angles of 60 to 135 degree, and 1.4% for gantry angles of 225 to 300 degree. Conclusion: The CG-based radiation therapy simulator could make it possible to estimate the collision angle between gantry and couch or patient on the radiotherapy machine without verifying the collision angles in the radiation treatment room.

60 APPLIED LIFE SCIENCES↗

Modeling and Simulation of Variable Mass, Flexible Structures

The advent of the new Ares I launch vehicle has highlighted the need for advanced dynamic analysis tools for variable mass, flexible structures. This system is composed of interconnected flexible stages or components undergoing rapid mass depletion through the consumption of solid or liquid propellant. In addition to large rigid body configuration changes, the system simultaneously experiences elastic deformations. In most applications, the elastic deformations are compatible with linear strain-displacement relationships and are typically modeled using the assumed modes technique. The deformation of the system is approximated through the linear combination of the products of spatial shape functions and generalized time coordinates. Spatial shape functions are traditionally composed of normal mode shapes of the system or even constraint modes and static deformations derived from finite element models of the system. Equations of motion for systems undergoing coupled large rigid body motion and elastic deformation have previously been derived through a number of techniques [1]. However, in these derivations, the mode shapes or spatial shape functions of the system components were considered constant. But with the Ares I vehicle, the structural characteristics of the system are changing with the mass of the system. Previous approaches to solving this problem involve periodic updates to the spatial shape functions or interpolation between shape functions based on system mass or elapsed mission time. These solutions often introduce misleading or even unstable numerical transients into the system. Plus, interpolation on a shape function is not intuitive. This paper presents an approach in which the shape functions are held constant and operate on the changing mass and stiffness matrices of the vehicle components. Each vehicle stage or component finite element model is broken into dry structure and propellant models. A library of propellant models is used to describe the distribution of mass in the fuel tank or Solid Rocket Booster (SRB) case for various propellant levels. Based on the mass consumed by the liquid engine or SRB, the appropriate propellant model is coupled with the dry structure model for the stage. Then using vehicle configuration data, the integrated vehicle model is assembled and operated on by the constant system shape functions. The system mode shapes and frequencies can then be computed from the resulting generalized mass and stiffness matrices for that mass configuration. The rigid body mass properties of the vehicle are derived from the integrated vehicle model. The coupling terms between the vehicle rigid body motion and elastic deformation are also updated from the constant system shape functions and the integrated vehicle model. This approach was first used to analyze variable mass spinning beams and then prototyped into a generic dynamics simulation engine. The resulting code was tested against Crew Launch Vehicle (CLV-)class problems worked in the TREETOPS simulation package and by Wilson [2]. The Ares I System Integration Laboratory (SIL) is currently being developed at the Marshall Space Flight Center (MSFC) to test vehicle avionics hardware and software in a hardware-in-the-loop (HWIL) environment and certify that the integrated system is prepared for flight. The Ares I SIL utilizes the Ares Real-Time Environment for Modeling, Integration, and Simulation (ARTEMIS) tool to simulate the launch vehicle and stimulate avionics hardware. Due to the presence of vehicle control system filters and the thrust oscillation suppression system, which are tuned to the structural characteristics of the vehicle, ARTEMIS must incorporate accurate structural models of the Ares I launch vehicle. The ARTEMIS core dynamics simulation models the highly coupled nature of the vehicle flexible body dynamics, propellant slosh, and vehicle nozzle inertia effects combined with mass and flexible body properties that vary significant with time during the flight. All forces that act on the vehicle during flight must be simulated, including deflected engine thrust force, spatially distributed aerodynamic forces, gravity, and reaction control jet thrust forces. These forces are used to excite an integrated flexible vehicle, slosh, and nozzle dynamics model for the vehicle stack that simulates large rigid body translations and rotations along with small elastic deformations. Highly effective matrix math operations on a distributed, threaded high-performance simulation node allow ARTEMIS to retain up to 30 modes of flex for real-time simulation. Stage elements that separate from the stack during flight are propagated as independent rigid six degrees of freedom (6DOF) bodies. This paper will present the formulation of the resulting equations of motion, solutions to example problems, and describe the resulting dynamics simulation engine within ARTEMIS.

Tobbe, Patrick A.↗

SU-E-T-314: The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation

Purpose: Monte Carlo simulation plays an important role for proton Pencil Beam Scanning (PBS) technique. However, MC simulation demands high computing power and is limited to few large proton centers that can afford a computer cluster. We study the feasibility of utilizing cloud computing in the MC simulation of PBS beams. Methods: A GATE/GEANT4 based MC simulation software was installed on a commercial cloud computing virtual machine (Linux 64-bits, Amazon EC2). Single spot Integral Depth Dose (IDD) curves and in-air transverse profiles were used to tune the source parameters to simulate an IBA machine. With the use of StarCluster software developed at MIT, a Linux cluster with 2–100 nodes can be conveniently launched in the cloud. A proton PBS plan was then exported to the cloud where the MC simulation was run. Results: The simulated PBS plan has a field size of 10×10cm{sup 2}, 20cm range, 10cm modulation, and contains over 10,000 beam spots. EC2 instance type m1.medium was selected considering the CPU/memory requirement and 40 instances were used to form a Linux cluster. To minimize cost, master node was created with on-demand instance and worker nodes were created with spot-instance. The hourly cost for the 40-node cluster was $0.63 and the projected cost for a 100-node cluster was $1.41. Ten million events were simulated to plot PDD and profile, with each job containing 500k events. The simulation completed within 1 hour and an overall statistical uncertainty of < 2% was achieved. Good agreement between MC simulation and measurement was observed. Conclusion: Cloud computing is a cost-effective and easy to maintain platform to run proton PBS MC simulation. When proton MC packages such as GATE and TOPAS are combined with cloud computing, it will greatly facilitate the pursuing of PBS MC studies, especially for newly established proton centers or individual researchers.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-106: Development of a Collision Prediction Algorithm for Determining Problematic Geometry for SBRT Treatments Using a Stereotactic Body Frame

Purpose: Collision between the gantry and the couch or patient during Radiotherapy is not a common concern for conventional RT (static fields or arc). With the increase in the application of stereotactic planning techniques to the body, collisions have become a greater concern. Non-coplanar beam geometry is desirable in stereotatic treatments in order to achieve sharp gradients and a high conformality. Non-coplanar geometry is less intuitive in the body and often requires an iterative process of planning and dry runs to guarantee deliverability. Methods: Purpose written software was developed in order to predict the likelihood of collision between the head of the gantry and the couch, patient or stereotatic body frame. Using the DICOM plan and structures set, exported by the treatment planning system, this software is able to predict the possibility of a collision. Given the plan's isocenter, treatment geometry and exterior contours, the software is able to determine if a particular beam/arc is clinically deliverable or if collision is imminent. Results: The software was tested on real world treatment plans with untreatable beam geometry. Both static non-coplanar and VMAT plans were tested. Of these, the collision prediction software could identify all as having potentially problematic geometry. Re-plans of the same cases were also tested and validated as deliverable. Conclusion: This software is capable of giving good initial indication of deliverability for treatment plans that utilize complex geometry (SBRT) or have lateral isocenters. This software is not intended to replace the standard pre-treatment QA dry run. The effectiveness is limited to those portions of the patient and immobilization devices that have been included in the simulation CT and contoured in the planning system. It will however aid the planner in reducing the iterations required to create complex treatment geometries necessary to achieve ideal conformality and organ sparing.

60 APPLIED LIFE SCIENCES↗

Infinite possibilities: Computational structures technology

Computational Fluid Dynamics (or CFD) methods are very familiar to the research community. Even the general public has had some exposure to CFD images, primarily through the news media. However, very little attention has been paid to CST--Computational Structures Technology. Yet, no important design can be completed without it. During the first half of this century, researchers only dreamed of designing and building structures on a computer. Today their dreams have become practical realities as computational methods are used in all phases of design, fabrication and testing of engineering systems. Increasingly complex structures can now be built in even shorter periods of time. Over the past four decades, computer technology has been developing, and early finite element methods have grown from small in-house programs to numerous commercial software programs. When coupled with advanced computing systems, they help engineers make dramatic leaps in designing and testing concepts. The goals of CST include: predicting how a structure will behave under actual operating conditions; designing and complementing other experiments conducted on a structure; investigating microstructural damage or chaotic, unpredictable behavior; helping material developers in improving material systems; and being a useful tool in design systems optimization and sensitivity techniques. Applying CST to a structure problem requires five steps: (1) observe the specific problem; (2) develop a computational model for numerical simulation; (3) develop and assemble software and hardware for running the codes; (4) post-process and interpret the results; and (5) use the model to analyze and design the actual structure. Researchers in both industry and academia continue to make significant contributions to advance this technology with improvements in software, collaborative computing environments and supercomputing systems. As these environments and systems evolve, computational structures technology will evolve. By using CST in the design and operation of future structures systems, engineers will have a better understanding of how a system responds and lasts, more cost-effective methods of designing and testing models, and improved productivity. For informational and educational purposes, a videotape is being produced using both static and dynamic images from research institutions, software and hardware companies, private individuals, and historical photographs and drawings. The extensive number of CST resources indicates its widespread use. Applications run the gamut from simpler university-simulated problems to those requiring solutions on supercomputers. In some cases, an image or an animation will be mapped onto the actual structure to show the relevance of the computer model to the structure. Transferring the digital files to videotape presents a number of problems related to maintaining the quality of the original image, while still producing a broadcast quality videotape. Since researchers normally do not create a computer image using traditional composition theories or video production requirements, often the image loses some of its original digital quality and impact when transferred to videotape. Although many CST images are currently available, those that are edited into the final project must meet two important criteria: they must complement the narration, and they must be broadcast quality when recorded on videotape.

Beam, Sherilee F.↗

Modality comparison for small animal radiotherapy: A simulation study

Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by the SARRP plan due to the sensitivity of the lower energy microCT beam to target heterogeneities and image noise. Conclusions: The two treatment planning examples demonstrate that modern small animal radiotherapy techniques employing image guidance, variable collimation, and multiple beam angles deliver superior dose distributions to small animal tumors as compared to conventional treatments using a single-field irradiator. For deep-seated mouse tumors, however, higher-energy conformal radiotherapy could result in higher doses to critical organs compared to lower-energy conformal radiotherapy. Treatment planning optimization for small animal radiotherapy should therefore be developed to take full advantage of the novel conformal systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

Monte Carlo performance on the x-ray converter thickness in digital mammography using software breast models

Purpose: In x-ray mammography, some of the components that play significant role to early diagnosis are the x-ray source, the breast composition as well as the composition of the x-ray converter. Various studies have previously investigated separately the influence of breast characteristics and detector configuration on the optimization of mammographic imaging systems. However, it is important to examine the combined effect of both components in improving the signal transfer properties in mammography systems of the mammograms. In the present study, the authors compared and evaluated x-ray converters using software breast models and realistic mammographic spectra in terms of: (a) zero-frequency detective quantum efficiency (DQE) and (b) sensitivity. The impact of x-ray converter thickness on contrast threshold (C{sub TH}) for observer assessment, based on the Rose model, was demonstrated as well. Methods: Monte Carlo techniques were applied to simulate the x-ray interactions within the software breast phantoms and thereafter within the detective medium. Simulations involved: (a) two mammographic x-ray spectra: 28 kV Mo, 0.030 mm Mo, and 32 kV W, 0.050 mm Rh of different entrance surface air kerma (ESAK: 3-7 mGy), (b) realistic breast models (dense and fatty) and (c) x-ray converter materials most frequently considered in investigations on energy integrating digital mammography detectors: the Gd{sub 2}O{sub 2}S:Tb granular phosphor, the CsI:Tl structured phosphor, and the a-Se photoconductive layer. Detector material thickness was considered to vary in the range from 50 mg/cm{sup 2} up to 150 mg/cm{sup 2}. Results: The Monte Carlo study showed that: (a) the x-ray beam becomes less penetrating after passing through dense breasts leading to higher values of zero-frequency DQE of the x-ray imaging converters and improved C{sub TH} values in all cases considered, (b) W/Rh target/filter combination results in improved C{sub TH} values at higher ESAK values, and (c) a-Se shows higher zero-frequency DQE values than the phosphor-based converters, Gd{sub 2}O{sub 2}S:Tb and CsI:Tl. However, thicker layers of CsI:Tl could be comparable to a-Se layers achieving approximately 27.6% C{sub TH} improvement at a thickness of 150 mg/cm{sup 2}. Conclusions: The present Monte Carlo investigation indicates that in the energy range employed in mammography, an upper limit, approximately 100 mg/cm{sup 2}, should be considered in the development of thicker a-Se converters. On the other hand, above this thickness value, CsI:Tl converter could improve its imaging performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries - application to far-from-axis fields

Purpose: Two new codes, PENEASY and PENEASYLINAC, which automate the Monte Carlo simulation of Varian Clinacs of the 600, 1800, 2100, and 2300 series, together with their electron applicators and multileaf collimators, are introduced. The challenging case of a relatively small and far-from-axis field has been studied with these tools. Methods: PENEASY is a modular, general-purpose main program for the PENELOPE Monte Carlo system that includes various source models, tallies and variance-reduction techniques (VRT). The code includes a new geometry model that allows the superposition of voxels and objects limited by quadric surfaces. A variant of the VRT known as particle splitting, called fan splitting, is also introduced. PENEASYLINAC, in turn, automatically generates detailed geometry and configuration files to simulate linacs with PENEASY. These tools are applied to the generation of phase-space files, and of the corresponding absorbed dose distributions in water, for two 6 MV photon beams from a Varian Clinac 2100 C/D: a 40 x 40 cm{sup 2} centered field; and a 3 x 5 cm{sup 2} field centered at (4.5, -11.5) cm from the beam central axis. This latter configuration implies the largest possible over-traveling values of two of the jaws. Simulation results for the depth dose and lateral profiles at various depths are compared, by using the gamma index, with experimental values obtained with a PTW 31002 ionization chamber. The contribution of several VRTs to the computing speed of the more demanding off-axis case is analyzed. Results: For the 40 x 40 cm{sup 2} field, the percentages {gamma}{sub 1} and {gamma}{sub 1.2} of voxels with gamma indices (using 0.2 cm and 2% criteria) larger than unity and larger than 1.2 are 0.2% and 0%, respectively. For the 3 x 5 cm{sup 2} field, {gamma}{sub 1} = 0%. These figures indicate an excellent agreement between simulation and experiment. The dose distribution for the off-axis case with voxels of 2.5 x 2.5 x 2.5 mm{sup 3} and an average standard statistical uncertainty of 2% (1{sigma}) is computed in 3.1 h on a single core of a 2.8 GHz Intel Core 2 Duo processor. This result is obtained with the optimal combination of the tested VRTs. In particular, fan splitting for the off-axis case accelerates execution by a factor of 240 with respect to standard particle splitting. Conclusions: PENEASY and PENEASYLINAC can simulate the considered Varian Clinacs both in an accurate and efficient manner. Fan splitting is crucial to achieve simulation results for the off-axis field in an affordable amount of CPU time. Work to include Elekta linacs and to develop a graphical interface that will facilitate user input is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel approach in electron beam radiation therapy of lips carcinoma: A Monte Carlo study

Purpose: Squamous cell carcinoma (SCC) is commonly treated by electron beam radiotherapy (EBRT) followed by a boost via brachytherapy. Considering the limitations associated with brachytherapy, in this study, a novel boosting technique in EBRT of lip carcinoma using an internal shield as an internal dose enhancer tool (IDET) was evaluated. An IDET is referred to a partially covered internal shield located behind the lip. It was intended to show that while the backscattered electrons are absorbed in the portion covered with a low atomic number material, they will enhance the target dose in the uncovered area. Methods: Monte-Carlo models of 6 and 8 MeV electron beams were developed using BEAMnrc code and were validated against experimental measurements. Using the developed models, dose distributions in a lip phantom were calculated and the effect of an IDET on target dose enhancement was evaluated. Typical lip thicknesses of 1.5 and 2.0 cm were considered. A 5 Multiplication-Sign 5 cm{sup 2} of lead covered by 0.5 cm of polystyrene was used as an internal shield, while a 4 Multiplication-Sign 4 cm{sup 2} uncovered area of the shield was used as the dose enhancer. Results: Using the IDET, the maximum dose enhancement as a percentage of dose at d{sub max} of the unshielded field was 157.6% and 136.1% for 6 and 8 MeV beams, respectively. The best outcome was achieved for lip thickness of 1.5 cm and target thickness of less than 0.8 cm. For lateral dose coverage of planning target volume, the 80% isodose curve at the lip-IDET interface showed a 1.2 cm expansion, compared to the unshielded field. Conclusions: This study showed that a boost concomitant EBRT of lip is possible by modifying an internal shield into an IDET. This boosting method is especially applicable to cases in which brachytherapy faces limitations, such as small thicknesses of lips and targets located at the buccal surface of the lip.

60 APPLIED LIFE SCIENCES↗

Performance tuning of CEED software and 1st and 2nd wave apps

The goal of this milestone was the performance tuning of the CEED software, as well as the use and tuning of CEED to accelerate the first and second wave of targeted ECP applications. In this milestone, the CEED team developed optimization techniques and tuned for performance the CEED software to accelerate the first and second wave target ECP applications. Specifically, the focus was on the following: (1) Efficient use of the memory sub-system for managing data motion and interactions among different physics packages and libraries; this included integration of the new developments in a libCEED 0.5 software release; (2) Enhancing the CEED libraries with GPU and AMD GPU support in close interaction with vendors; (3) Optimal data locality and motion, and enhanced scalability and parallelism; this included vendors interactions for improvements in data motion and making strong scaling easier and more efficient; and (4) Continue boosting performance for the first-wave and second-wave of ECP target applications, including ExaSMR, ExaWind, Urban, MARBL, E3SM, and ExaAM. A main part of this milestone was the performance tuning of the CEED first-wave and second-wave ECP applications. This included the ExaSMR application – Coupled Monte Carlo Neutronics and Fluid Flow Simulation of Small Modular Reactors (ORNL), the MARBL application – Next-Gen Multi-physics Simulation Code (LLNL), and the ExaAM ExaConstit – a miniapp for the Transforming Additive Manufacturing through Exascale Simulation applications project (ExaAM), as well as ExaWind, Urban, and E3SM. The artifacts delivered include performance improvements in CEED’s 1st and 2nd wave of applications, and tuned CEED software for various architectures through a number of backends, freely available in the CEED’s repository on GitHub. See the CEED website, http://ceed.exascaleproject.org and the CEED GitHub organization, http://github.com/ceed for more details. In addition to details and results from the above R&D efforts, in this document we are also reporting on other project-wide activities performed in Q4 of FY19 including: CEED’s third annual meeting, MFEM GPU kernels scaling improvements, libCEED 0.5 and NekRS releases, an overview paper covering latest results on a set of bake-off high-order finite element problems (BPs), and other outreach efforts.

97 MATHEMATICS AND COMPUTING↗

Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and the other eye components, proton and carbon DVHs (Dose Volume Histograms) are compared. A high statistics simulated sample is used to minimize statistical errors. In the simulation a new particle generation method is developed in order to reproduce the experimental treatment plan by importing the DICOM RT-PLAN file, which contains all the information on the irradiation geometries and sequences (treatment plan parameters). Conclusions Even further validations must be done, the good results so far obtained by this work point out and confirm the possibility of using carbon ions delivered with active scanning beams to treat the ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Uplinks Per Antenna (MUPA) Signal Acquisition Schemes

The Deep Space Network (DSN) currently makes use of the technique of Multiple Spacecraft per Antenna (MSPA) where a single antenna is used to track multiple spacecraft downlinks within its beam, such as in the case of multiple spacecraft orbiting Mars at 8.4 GHz (X-band). It is desired to extend this technique to the uplink where a single station is used to send a signal to multiple spacecraft in order to make more efficient use of ground resources. This would be applicable to numerous smallsat constellations being considered for future missions or to future spacecraft at Venus, Mars, or more distant destinations that are all within the half-power beamwidth of a single 34-m diameter antenna. In one scheme, each spacecraft’s command sequences would be time multiplexed onto a single uplink frequency. Each spacecraft would lock onto the uplink signal and would accept only commands intended for it via special identifier codes. Each spacecraft would also emit a downlink signal to the ground that is coherent with the uplink signal but would have its own allocated frequency channel and identifier information. A couple of key challenges associated with using this technique need to be addressed. Because of the single uplink frequency, coherent turnaround for two-way Doppler and ranging would not conform to established ratios, thus the radios employed by the spacecraft would need to be capable of variable turnaround ratios. In addition, because of the different orbits or spacecraft trajectories, the relative Doppler shifts and rates can be large with respect to the common uplink signal whose frequency would lie at the centroid of the frequencies of the expected received signals of the constellation. This would be problematic with standard analog spacecraft radios whose acquisition bandwidths are relatively small (~1.7 kHz) relative to the large frequency offsets (~100 kHz) expected using the single frequency uplink technique. With the advent of software defined radios (SDRs), signal frequency search algorithms can be utilized within the flight software and/or programmable hardware (e.g., FPGAs) that can easily acquire and track signals with large frequency offsets and varying dynamics. Such techniques could include FFT search algorithms, step-and-sweep search algorithms, or onboard frequency steering making use of trajectory vectors uplinked to each member spacecraft. Other challenges include mitigation of potential interference between received signals. We have identified several software defined radios that are in different stages of development and whose key parameters have been tabulated. We have examined each radio’s capabilities with respect to acquiring and tracking signals with large frequency offsets. Such analyses made use of previous studies supplemented with specially designed tests using both simulation tools and/or existing testbeds. We have compared signal acquisition times computed from provided algorithms along with measured values derived from tests using existing hardware and simulation tools for the purpose of conducting tradeoff studies between the various radio designs and software/firmware programming approaches.

Abraham, Douglas S.↗

Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery

Purpose: To efficiently deliver respiratory-gated radiation during synchrotron-based pulsed heavy-ion radiotherapy, a novel respiratory guidance method combining a personalized audio-visual biofeedback (BFB) system, breath hold (BH), and synchrotron-based gating was designed to help patients synchronize their respiratory patterns with synchrotron pulses and to overcome typical limitations such as low efficiency, residual motion, and discomfort. Methods: In-house software was developed to acquire body surface marker positions and display BFB, gating signals, and real-time beam profiles on a LED screen. Patients were prompted to perform short BHs or short deep breath holds (SDBH) with the aid of BFB following a personalized standard BH/SDBH (stBH/stSDBH) guiding curve or their own representative BH/SDBH (reBH/reSDBH) guiding curve. A practical simulation was performed for a group of 15 volunteers to evaluate the feasibility and effectiveness of this method. Effective dose rates (EDRs), mean absolute errors between the guiding curves and the measured curves, and mean absolute deviations of the measured curves were obtained within 10%–50% duty cycles (DCs) that were synchronized with the synchrotron’s flat-top phase. Results: All maneuvers for an individual volunteer took approximately half an hour, and no one experienced discomfort during the maneuvers. Using the respiratory guidance methods, the magnitude of residual motion was almost ten times less than during nongated irradiation, and increases in the average effective dose rate by factors of 2.39–4.65, 2.39–4.59, 1.73–3.50, and 1.73–3.55 for the stBH, reBH, stSDBH, and reSDBH guiding maneuvers, respectively, were observed in contrast with conventional free breathing-based gated irradiation, depending on the respiratory-gated duty cycle settings. Conclusions: The proposed respiratory guidance method with personalized BFB was confirmed to be feasible in a group of volunteers. Increased effective dose rate and improved overall treatment precision were observed compared to conventional free breathing-based, respiratory-gated irradiation. Because breathing guidance curves could be established based on the respective average respiratory period and amplitude for each patient, it may be easier for patients to cooperate using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRB-01: Development of a Probe-Format Graphite Calorimeter for Practical Clinical Dosimetry: Numerical Design Optimization, Prototyping, and Experimental Proof-Of-Concept

Purpose: In this work, the feasibility of performing absolute dose to water measurements using a constant temperature graphite probe calorimeter (GPC) in a clinical environment is established. Methods: A numerical design optimization study was conducted by simulating the heat transfer in the GPC resulting from irradiation using a finite element method software package. The choice of device shape, dimensions, and materials was made to minimize the heat loss in the sensitive volume of the GPC. The resulting design, which incorporates a novel aerogel-based thermal insulator, and 15 temperature sensitive resistors capable of both Joule heating and measuring temperature, was constructed in house. A software based process controller was developed to stabilize the temperatures of the GPC’s constituent graphite components to within a few 10’s of µK. This control system enables the GPC to operate in either the quasi-adiabatic or isothermal mode, two well-known, and independent calorimetry techniques. Absorbed dose to water measurements were made using these two methods under standard conditions in a 6 MV 1000 MU/min photon beam and subsequently compared against TG-51 derived values. Results: Compared to an expected dose to water of 76.9 cGy/100 MU, the average GPC-measured doses were 76.5 ± 0.5 and 76.9 ± 0.5 cGy/100 MU for the adiabatic and isothermal modes, respectively. The Monte Carlo calculated graphite to water dose conversion was 1.013, and the adiabatic heat loss correction was 1.003. With an overall uncertainty of about 1%, the most significant contributions were the specific heat capacity (type B, 0.8%) and the repeatability (type A, 0.6%). Conclusion: While the quasi-adiabatic mode of operation had been validated in previous work, this is the first time that the GPC has been successfully used isothermally. This proof-of-concept will serve as the basis for further study into the GPC’s application to small fields and MRI-linac dosimetry. This work has been supported in part by the CREATE Medical Physics Research Training Network of the Natural Sciences and Engineering Research Council (NSERC) grant 432290, NSERC grants RGPIN 298191 & 435608-13, Canadian Institutes of Health Research doctoral scholarship GSD-121793. This work has also been supported by Sun Nuclear Corporation.

60 APPLIED LIFE SCIENCES↗