Simulation of shot noise effects in the EIC strong hadron cooling accelerator using real number of electrons

In the electron ion collider design, in order to achieve the peak luminosity 10 34 /cm 2 /s with a reasonable lifetime, an efficient coherent electron cooling scheme was proposed to reduce the hadron beam emittance growth. Such a cooling scheme requires a good electron beam quality with a small energy spread. However, the shot noise in the electron beam through the accelerator might be amplified due to the microbunching instability and degrades the electron beam quality in the modulator section of the strong hadron cooling channel and correspondingly cooling rate. In this study, we report on self-consistent simulations of these effects using a real number of electrons to capture the details of shot noise and analysis of the shot noise growth through the accelerator.

Qiang, Ji↗

Electron Cooling With Space-Charge Dominated Proton Beams at IOTA

We describe a new electron cooler being developed for 2.5 MeV protons at the Integrable Optics Test Accelerator (IOTA), which is a highly re-configurable storage ring at Fermilab. This system would enable the study of magnetized electron cooling in the presence of intense space-charge with transverse tune shifts approaching -0.5 as well as highly non-linear focusing optics in the IOTA ring. We present an overview of the design, simulations and hardware to be used for this project.

43 PARTICLE ACCELERATORS↗

Beam optics design of a prototype 20 kW conduction-cooled SRF accelerator for medical sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

Saini, A. [Fermilab]↗

Beam Optics Design of A Prototype 20 kW Conduction-Cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Beam Optics Design of a Prototype 20 KW Conduction-cooled SRF Accelerator for Medical Sterilization

Superconducting technology has significantly advanced the capabilities of particle accelerators, facilitating higher beam-power operations for fundamental research at a comparatively lower cost. However, the conventional implementation of superconducting technology introduces complexities in the form of cryogenic plants, cryogenic distribution systems and substantial construction and operational cost. In response to these challenges, recent research efforts at Fermilab have been dedicated to the development of a cryogen-free, conduction-cooled Nb3Sn-based superconducting technology. This paper outlines the beam optics design of a 20-kW conduction-cooled compact superconducting accelerator for medical sterilization. The paper reviews both the physics and practical constraints associated with high beam-power operation within the context of industrial applications. The focus is on providing insights into the potential of this innovative technology to overcome existing challenges and pave the way for more accessible and efficient industrial particle accelerators.

43 PARTICLE ACCELERATORS↗

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

The Accelerator Design Progress for EIC Strong Hadron Cooling

The Electron-Ion Collider will achieve a luminosity of 1034 cm-2 s-1 by incorporating strong hadron cooling to counteract hadron Intra-Beam Scattering, using a coherent electron cooling scheme. An accelerator will deliver the beams with key parameters, such as 1 nC bunch charge, and 1e-4 energy spread. The paper presents the design and beam dynamics simulation results. Methods to minimize beam noise, the challenges of the accelerator design, and the R&D topics being pursued are discussed.

Wang, E.↗

Superconducting RF Gun with High Current and the Capability to Generate Polarized Electron Beams

High-current low-emittance CW electron beams are indispensable for nuclear and high-energy physics fixed target and collider experiments, cooling high energy hadron beams, generating CW beams of monoenergetic X-rays (in FELs) and gamma-rays (in Compton sources). Polarization of electrons in these beams provides extra value by opening a new set of observables and frequently improving the data quality. We report on the upgrade of the unique and fully functional CW SRF 1.25 MeV SRF gun, built as part of the Coherent electron Cooling (CeC) project, which has demonstrated sustained CW operation with CsK2Sb photocathodes generating electron bunches with record-low transverse emittances and record-high bunch charge exceeding 10 nC. We propose to extend the capabilities of this system to high average current of 100 milliampere in two steps: increasing the current 30-fold at each step with the goal to demonstrate reliable long-term operation of the high-current low-emittance CW SRF guns. We also propose to test polarized GaAs photocathodes in the ultra-high vacuum (UHV) environment of the SRF gun, which has never been successfully demonstrated in RF accelerators.

43 PARTICLE ACCELERATORS↗

Flare heating by energetic nonthermal electrons

A model has been developed which includes, in a self-consistent fashion, the energy degradation and attendant bremsstrahlung emission of a high-energy electron beam, heating of a flare plasma by the beam, and subsequent cooling by thermal conduction and radiation. To assist in the interpretation of experimental diagnostics, the model also characterizes the radiative behavior of iron ions present in the flare plasma. Electron deposition is described by the Fokker-Planck equation for an initial power-law particle distribution. Results are presented for the bremsstrahlung radiation emitted by the incident beam as it impinges on the disturbed atmosphere. A comparison is made between direct beam heating and thermal-conduction heating of the flare plasma. The radiation emitted by several selected spectral lines of Fe ions is determined as a function of time during and after deposition

Davis, J.↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Transverse BBU Suppression with Feedback for Energy-Recovery Linacs

The Electron–Ion Collider (EIC) achieves its design luminosity by cooling the ion beam with a high-current electron beam generated in an energy-recovery linac (ERL). The baseline ERL lattice employs a BNL five-cell cavity that is frequency-scaled to 197 MHz, 591 MHz, and 1.773 GHz, raising concerns about multibunch beam-breakup (BBU) instabilities. Threshold currents for each frequency option are established with two independent BBU tracking codes, providing cross-validated operating margins that guide cavity selection. To further increase the current limit, we incorporate a digital transverse feedback (FB) system that targets the dominant higher-order modes (HOMs). Simulations show the FB raises the BBU threshold by roughly an order of magnitude: power-spectral-density analysis of the beam centroid at the linac exit confirms strong suppression of the aliased HOM peak, although some spectral growth appears at secondary frequencies. This combined study quantifies baseline BBU limits, demonstrates effective active mitigation, and charts a practical path toward robust, high-current operation of the EIC ERL.

Accelerator Physics↗

Near-infrared two-color pyrometer for determining ignition temperatures of metals and metal alloys

A two-color pyrometer has been designed, constructed, and used to measure the ignition temperatures of metals and metal alloys. Cylindrical metal and metal alloy specimens were ignited by a focused cw CO2 laser beam in a cool, static, pure oxygen environment. The pyrometer operates in the near-infrared at two narrow spectral regions, with a nominal bandwidth of 10 nm centered at 0.9051 and 1.06 micron, and has a temperature range from 1000 to 4000 K. In the present design the temperature of a spot, about 0.5 mm in diameter, can be recorded with a maximum time resolution of 25 microseconds and with an accuracy of a few percent. Results of CO2 laser ignition of cylindrical specimens of 6061 aluminum alloy and 302 SS in a pure oxygen environment were obtained from the two-color pyrometer and were compared with those obtained from a thermocouple placed inside the specimen near the laser-irradiated surface.

Nguyen, K.↗

Ignition of bulk 302 stainless steel in oxygen by laser heating

The effect of oxygen pressure on the ignition temperature of cylindrical 302 SS specimens ignited by a focused CW CO2 laser beam in a cool, static, oxygen environment was investigated. The ignition temperature was determined quantitatively from the specimen temperature history obtained from a fast response, near infrared, two-color pyrometer, which recorded the temperature history of a spot approximately 0.5 mm in diameter and located at the center of the cylindrical 302 SS specimen's top surface. Ignition and combustion occurred in three stages. The first stage began with specimen heating and ended with ignition, the second stage corresponded to combustion, and the third stage represented cooling. The physical changes that occurred in the first stage are described.

Nguyen, K.↗

Laser ignition of bulk 1018 carbon steel in pure oxygen

Experiments were undertaken to study the ignition characteristics of bulk 1018 carbon steel in a pure oxygen environment. Cylindrical 1018 carbon steel specimens 5 mm in diameter and 5 mm high were ignited by a focused CW CO2 laser beam in a cool, static, pure oxygen environment at oxygen pressures ranging from 0.103 to 6.895 MPa. A two-color pyrometer was designed and used to measure the ignition temperatures of the specimens. The temperature history of a spot approximately 0.5 mm in diameter located at the center of the specimen top surface was recorded with a maximum time resolution of 25 microsec, and with an accuracy of a few percent. Ignition temperature of bulk 1018 carbon steel was identified from the temperature history curve with the aid of the light intensity curve. Results show that 1018 carbon steel specimens ignite at temperatures between 1388 and 1450 K, which are below the melting range of the alloy (1662-1685 K). The ignition temperature of 1018 carbon steel is mildly dependent on oxygen pressure over the range of oxygen pressure investigated in this study.

Nguyen, K.↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

In order to prevent emittance growth during long stores of the proton beam at the future Electron-Ion Collider (EIC), we need to have some mechanism to provide fast cooling of the dense proton beams. One promising method is coherent electron cooling (CeC), which uses an electron beam to both ?measure? the positions of protons within the bunch and then apply energy kicks which tend to reduce their longitudinal and transverse actions. In this work, we discuss the under- lying physics of this process. We then discuss simulations which constrain the electrons to move only longitudinally in order to perform fast optimizations and long-term track- ing of the bunch evolution, and benchmark these results against fully 3D codes. Additionally, we discuss practical challenges, including the necessity of a high-quality elec- tron beam and sub-micron alignment of the electrons and protons.

Deitrick, K.↗

Improved Electrostatic Design of the Jefferson Lab 300 kV DC Photogun and the Minimization of Beam Deflection

An electron beam with high bunch charge and high repetition rate is required for electron cooling of the ion beam to achieve the high luminosity required for the proposed electron-ion colliders. An improved design of the 300 kV DC high voltage photogun at Jefferson Lab was incorporated toward overcoming the beam loss and space charge current limitation experienced in the original design. To reach the bunch charge goal of ~ few nC within 75 ps bunches, the existing DC high voltage photogun electrodes and anode-cathode gap were modified to increase the longitudinal electric field (Ez) at the photocathode. The anode-cathode gap was reduced to increase the Ez at the photocathode, and the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the geometric asymmetry of the inverted insulator photogun. The electrostatic design and beam dynamics simulations were performed to determine the required modification. Beam-based measurement from the modified gun confirmed the reduction of the beam deflection, which is presented in this contribution.

Mamun, M. A.↗

Supercooling effects in Cu-10 wt pct Co alloys solidified at different cooling rates

Electromagnetic levitation and electron beam surface melting were employed to study the effects of supercooling and cooling rate on the solidification of Cu-10 wt pct Co alloys. Two major effects were observed in the supercooled alloys: the nucleation of a metastable copper-rich phase which contains 13 wt pct to 20 wt pct Co in samples supercooled between 105 and 150 K and liquid phase separation which occurs in samples supercooled 150 K or more. The microstructure of the electron beam melted surfaces consisted of very fine spheres which were similar to those of the sample supercooled more than 150 K but with a refined microstructure. The results indicate that a dynamic bulk supercooling of 150 K may exist in the molten pool during the solidification of electron beam melted surfaces.

Munitz, A.↗