Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Pulsed electron beam emission in space

During the Spacelab-2 mission of July 1985, electron beams (1 keV, 50-150 mA) pulsed at ELF and VLF frequencies were emitted from the Space Shuttle Orbiter. The wave fields generated by the beam were monitored by a Plasma Diagnostics Package which was released as a free-flying subsatellite during a six hour period. Measurements of the Orbiter potential and the return current during beam emissions were obtained from a Charge and Current Probe mounted in the payload bay.

Neubert, T.↗

An analysis of whistler mode radiation from the Spacelab 2 electron beam

During the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the Shuttle to free fly. At times during this free flight, when the PDP was magnetically connected to the Shuttle, Stanford's fast-pulsed electron generator, located in the Shuttle cargo bay, ejected a 1-keV 50-mA electron beam. The PDP plasma-wave instrument detected intense whistler-mode radiation during these beam ejections. This paper presents a study of a whistler mode emission detected during one particular continuous electron beam firing. Calculations indicate that the beam radiated approximately 1.6 mW in the whistler mode as the beam traversed the 200 m from the Shuttle to the PDP. The emissivity also decreased by about a factor of 10 over this same distance. The measured wave powers are 10 to the 7th greater than wave powers expected from incoherent Cerenkov radiation, verifying that the radiation is generated by a coherent process. Estimates of the emissivity based on measured electric field intensities in the beam indicate that the whistler-mode noise is produced by radiation from electron bunches created by an electrostatic beam-plasma instability.

Farrell, W. M.↗

High resolution X-ray optics for astronomical and laboratory sources

In recent years X-ray telescopes have been used successfully for high resolution observations of astronomical objects, in particular the solar corona. At the present time X-ray microscopes are being developed for diagnostics of laser and electron beam induced fusion plasmas. This paper describes both types of imaging systems using as examples the AS&E X-ray telescope on Skylab and a 10X microscope being built for Los Alamos Scientific Laboratories. The designs, manufacturing tolerances, fabrication, testing, and performance are discussed. Steps for further development in both imaging areas are identified.

Silk, J. K.↗

Unsteady turbulent shear flow in shock tube discontinuities

A pressure-ruptured shock tube and an arc driven shock tube, have been used to study the evolution of turbulent fluctuations at contact surfaces with N2O4-2NO2 mixtures and at ionizing shock fronts in argon. The study has focused on point density diagnostics derived from crossed light beam correlations and electric probes. Turbulent bursts are found for which dynamical and spectral analyses suggest a particle-like evolution of fluctuation segments with a unique and characteristic frequency, independent of flow history and overall flow conditions.

Johnson, J. A., III↗

High-frequency instability of the sheath-plasma resonance

Coherent high frequency oscillations near the electron plasma frequency (omega approx. less than omega sub p) are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diode-like electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening and copious harmonics. The fundamental instability is a bounded oscillation due to wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres) which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line broadening mechanism was identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burst-like RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.↗

High-frequency instability of the sheath-plasma resonance

Coherent high-frequency oscillations near the electron plasma frequency are generated by electrodes with positive dc bias immersed in a uniform Maxwellian afterglow plasma. The instability occurs at the sheath-plasma resonance and is driven by a negative RF sheath resistance associated with the electron inertia in the diodelike electron-rich sheath. With increasing dc bias, i.e., electron transit time, the instability exhibits a hard threshold, downward frequency pulling, line broadening, and copious harmonics. The fundamental instability is a bounded oscillation caused by wave evanescence, but the harmonics are radiated as electromagnetic waves from the electrodes acting like antennas. Wavelength and polarization measurements confirm the emission process. Electromagnetic waves are excited by electrodes of various geometries (planes, cylinders, spheres), which excludes other radiation mechanisms such as orbitrons or beam-plasma instabilities. The line-broadening mechanism has been identified as a frequency modulation via the electron transit time by dynamic ions. Ion oscillations at the sheath edge give rise to burstlike RF emissions. These laboratory observations of a new instability are important for antennas in space plasmas, generation of coherent beams with diodes, and plasma diagnostics.

Stenzel, R. L.↗

Time dependency of temperature of a laser-irradiated infrared target pixel as a low-pass filter

The thermal response of a surface layer of a pixel on an infrared target simulator is discussed. This pixel is maintained at a constant temperature by a rapidly scanning laser beam. An analytical model has been developed to describe the exact temperature dependence of a pixel as a function of time for different pixel refresh rates. The top layer of the pixel surface that generates the gray-body radiation shows the temperature dependence on time that is characteristic of a low-pass filter. The experimental results agree with the analytical predictions. The application of a pulsed laser beam to a noncontact, nondestructive diagnostic technique of surface characterization for the presence of microdefects is discussed.

Scholl, Marija S.↗

Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

Tabibi, Bagher M.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment

Many space propulsion concepts exist that use matter-antimatter reactions. Current antiproton production rates are enough to conduct proof-of-principle evaluation of these concepts. One enabling technology for such experiments is portable storage of low energy antiprotons, to transport antiprotons to experimental facilities. To address this need, HiPAT is being developed, with a design goal of containing 10(exp 12) particles for up to 18 days. HiPAT is a Penning-Malmberg trap with a 4 Tesla superconductor, 20kV electrodes, radio frequency (RF) network, and 10(exp -13) Torr vacuum. 'Normal' matter is being used to evaluate the system. An electron beam ionizes background gas in situ, and particle beams are captured dynamically. The experiment examines ion storage lifetimes, RF plasma diagnostics, charge exchange with background gases, and dynamic ion beam capture.

Martin, James J.↗

AMPAS - A new active experiment mission

A new concept for an active experiments mission is presented: The Active Magnetospheric Particle Acceleration Satellite (AMPAS). It is proposed to fly a dual-payload tethered satellite to study three important areas of magnetopsheric physics: (1) electric and magnetic field structures of the Earth's magnetosphere, (2) electron beam-plasma interactions, and (3) far ultraviolet (FUV) signatures of energetic electron precipitation. The tethered system is to be flown in a gravity-gradient stabilized configuration with a 70 deg circular orbit at altitudes in the range 300-800 km. The upper payload will carry two electron beam accelerators (1-10 keV, 1 A) and a plasma contractor to electrically neutralize the payload, while the lower will carry a complement of optical imaging and plasma diagonstics instrumentation. Upward directed beams are injected to 'sound' electric and magnetic field structures, including parallel electric fields in the auroral region, while simultaneous optical instruments aimed downwards measure characteristics of reflected beam pulses precipitating into the upper atmosphere below the satellite. Downward directed beams, and simultaneous plasma wave, particle and optical measurements, are used for the investigation of beam-plasma interactions and electron precipitation studies. The payloads are to be connected by a 1-6 km long tether to be deployed in stages. The configuration of the beam source and the plasma and optical diagnostics on separate, tethered payloads allows the diagnostics to be performed outside of the disturbed region around the source payload, and plasma wave and particle observations of beam-plasma interactions to be performed at well-defined locations relative to the source.

Neubert, T.↗

SEM Grid Testing at NLCTA in BeamNetUS Program

We report on the performance of a secondary electron monitor (SEM) grid used to measure the transverse profile of an MeV range electron beam at SLAC National Accelerator Laboratory’s Next Linear Collider Test Accelerator (NLCTA) facility. When inserted into the path of the electron beam, secondary electron emission results in a measurable current on the wires that make up the grid. We present measurements using this technique to reconstruct the beam profile. The SEM grid was designed and manufactured by a team of undergraduate students at Harvey Mudd College (HMC) and was tested at SLAC’s NLCTA facility in collaboration with NCLTA staff as part of the BeamNetUS program. Developed for real-time diagnostics of MeV-range electron beams, this SEM grid has potential applications in both industrial and medical contexts.

43 PARTICLE ACCELERATORS↗

Reduced fast-ion transport calculations of m = n = 1 fishbone-like instabilities in MAST-U

Fast-ion transport associated with an m = n = 1 fishbone-like burst in MAST-U discharge 47128 is investigated using a reduced guiding-center-based transport model (ORBIT-Kick) constrained by multi-diagnostic measurements. The two-dimensional beam-emission spectroscopy system provides measurements of the core poloidal mode structure and fluctuation amplitude, while EFIT++ reconstructions constrained by the motional Stark effect diagnostic indicate a flat q-profile with q 0 > 1⁠, indicating the absence of a resonant q = 1 surface and supporting a pressure-driven infernal-mode interpretation. Analytic m = n = 1 displacement profiles consistent with the measured core mode structure and equilibrium constraints are used as the mode structure inputs to ORBIT-Kick. The calculations show that the dominant resonances occur between the mode and co-passing fast ions, producing redistribution localized near the magnetic axis. Synthetic neutron camera signals from TRANSP-Kick recover up to 90% of the experimentally observed neutron deficit at the time of peak mode amplitude, indicating that the measured m = n = 1 mode is a dominant contributor to core fast-ion transport. However, the synthetic neutron signals recover rapidly, whereas the measured neutron emission continues to decrease after the peak amplitude. In conclusion, the remaining discrepancy may arise from contributions not included in the present single-harmonic model, including higher-m and higher-n harmonics, multi-harmonic interactions, and additional transport mechanisms, motivating future diagnostic development and modeling efforts to resolve and incorporate these additional contributions.

Wong, Henry H. [University of California, Los Ange↗

Electron beam characterization via quantum coherent electric field imaging

We demonstrate an all-optical, minimally invasive electron beam (𝑒−beam) characterization using Rydberg electrometry. An 𝑒-beam passes through a localized detector volume containing thermal Rb atoms that are optically excited in a quantum superposition of ground and Rydberg states. The 𝑒-beam's electric field perturbs atomic coherence and modifies resonance fluorescence in a narrow spectral region near the two-photon optical transition. Imaging Rb fluorescence provides a map of the electric field from the 𝑒-beam via Rydberg state Stark shifts and allows us to reconstruct the 𝑒-beam width, centroid position, and current. For an 𝑒-beam of 20 keV and electron currents of 20–40 µ⁢A, we measured the centroid position with an accuracy of ≤ 8 µ⁢m and width to within 100 µ⁢m, limited by the experimental sensitivity of electric field reconstruction of ∼0.02 V/cm. This method is suitable for a wide range of electron energies and currents, and can be adopted for nuclear and high-energy experiments for minimally invasive real-time diagnostics and profiling of charged particle beams.

Behary, Rob [College of William and Mary, Williams↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

Electromagnetic-wave excitation in a large laboratory beam-plasma system

The mechanism by which unstable electrostatic waves of a beam-plasma system are converted into observed electromagnetic waves is of current interest in space physics and in tokamak fusion research. The process involved in the conversion of electrostatic to electromagnetic waves at the critical layer is well understood. However, the radiation from uniform plasmas cannot be explained on the basis of this process. In connection with certain difficulties, it has not yet been possible to establish the involved emission processes by means of experimental observations. In the considered investigation these difficulties are overcome by employing a large laboratory plasma in a parameter range suitable for detailed diagnostics. A finite-diameter electron beam is injected into a uniform quiescent afterglow plasma of dimensions large compared with electromagnetic wavelengths. The considered generation mechanism concerning the electromagnetic waves is conclusively confirmed by observing the temporal evolution of an instability

Whelan, D. A.↗

Documentation of Air Emissions Source Term for Radionuclide NESHAP Compliance: TA-53 Building 0984 Isotope Production Facility

This paper will document the air emissions source term for the TA-53 Building 0984 Isotope Production Facility (IPF). The facility has historically been managed as a minor source under Radionuclide NESHAP regulations, but began using a wider variety of irradiation targets and a higher beam current. To support expanded generation of actinium-225 for medical diagnostic and therapeutic uses, IPF is now irradiating thorium targets and the beam current is planned to increase from 250 microamperes up to 600 microamperes. These changes merit a review of the anticipated source term under the new proposed operational conditions. The end result of the review indicates the main stack (Exhaust Stack ES-1) needs to be managed as a major source with continuous emissions monitoring. No additional advance notifications or permitting is required as a result of these operational changes.

54 ENVIRONMENTAL SCIENCES↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Numerical simulations of impulsively heated solar flares

The response of a model solar atmosphere to heating by an electron beam has been studied for electron beam flux spectra which are power laws with low-energy 'knees' (rising linearly with time to a peak at 30 s and then falling linearly to 0 at 60 s) ranging from 10 to 20 keV. The results indicate that high peak electron beam fluxes, low-energy knees, and larger spectral indices all move the atmospheric response toward greater enhancements of the parameters in the coronal regions of the atmosphere. Coronal responses can thus be used as a diagnostic of the parameters of the electron beam.

Mariska, John T.↗