Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nonlinear interferometer systems and methods

Nonlinear interferometers include a nonlinear optical medium that is situated to produce a conjugate optical beam in response to a pump beam and a probe beam. The pump, probe, and conjugate beams propagate displaced from each other along a common optical path. One of the beams is selectively phase shifted, and the beams are then returned to the nonlinear medium, with the selectively phase shift beam phase shifted again. The nonlinear medium provides phase sensitive gain to at least one of the probe or conjugate beams, and the amplified beam is detected to provide an estimate of the phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for a Long-Lived $\mu\mu$ Resonance in the NuMI Beam at ICARUS

The ICARUS detector in the Short-Baseline Neutrino program at Fermilab is sensitive to “long-lived” new physics particles that would be produced in the Neutrinos at the Main Injector (NuMI) beam and decay inside the ICARUS liquid argon time projection chamber (LArTPC). We show results from a new analysis in ICARUS which searched for di-muon decays from a long-lived particle produced in kaon decay in the NuMI beam. The search is sensitive to new areas of parameter space for the Higgs portal scalar and an axion-like particle model. The sensitivity is also presented in a model-independent way applicable to any new physics model predicting the process $K \to \pi+S(\to\mu\mu)$, for a long-lived particle S. This is the first search for new physics performed with the ICARUS detector at Fermilab. It paves the way for the future program of long-lived particle searches at ICARUS.

43 PARTICLE ACCELERATORS↗

Coupled Target-Beam-Moderator Optimization for the Second Target Station

This report describes the results for a coupled target-beam-moderator optimization analysis for the Second Target Station (STS) at ORNL's Spallation Neutron Source. This study is a continuation of the optimization analysis for the moderators in the preliminary design of STS performed in 2022. In the 2022 analysis the dimensions of the moderators are parameterized, while the target and the proton beam profile are kept constant. In this analysis the target height and the proton beam profile are added as parameters. This allows to study the coupled effects of changing target, moderator and beam dimensions. Similar to the 2022 analysis, this work is performed with an automated optimization workflow that uses the optimization toolbox DAKOTA, parameterized geometries in CREO and SpaceClaim, the unstructured mesh generation in Attila4MC, and the particle transport code MCNP6.2©. This workflow enables an efficient optimization using high-fidelity geometries. The main conclusions of this analysis are the following: • Coupled beam-target-moderator optimization provides a few additional percent performance gain over stand-alone moderator optimization. • The moderator performance is not very sensitive to the target height (between ≈60 and ≈80 mm) as long as the beam profile is chosen adequately. • The moderator performance is sensitive to the choice of beam spatial standard deviations, even when the footprint is kept constant. • The optimal moderator radius is the same for a beam footprint of 30 cm 2 , 62.5 cm 2 , and 90 cm 2 . Also the slope of the super-gaussian beam profile does not significantly impact the optimal moderator radius. • The optimal parameters and sensitivities are very similar to the 2022 optimization analysis. These results only indicate a a difference in the optimal radius of the cylindrical moderator, however, this has been corrected in the final design moderator optimization. The main purpose of this report is to document the simulations, results and lessons learned. The most impactful results are summarized in. We also note that the target geometry used in this work is not the final design.

43 PARTICLE ACCELERATORS↗

Quasielastic $\overrightarrow{^{3}He}$ $(\overrightarrow{e},e′)$ asymmetry in the threshold region with a longitudinally polarized target

We report on the measurements of the double-spin asymmetry from electron- 3 He scattering in the threshold region of two- and three-body breakup of 3 He for 4-momentum transfer values of 0.1 and 0.2 (GeV/c) 2 . The measurement was done at Jefferson Lab using a polarized 3 He target with its spin aligned parallel to the beam direction. This asymmetry is sensitive to a combination of spin-dependent response functions not previously measured and may highlight differences in two body forces, meson-exchange currents and final-state interactions. The results of this measurement serve as a test of our understanding of few-body systems. When compared with calculations from plane wave impulse approximation and Faddeev calculations, we found that the latter, which use modern nuclear potentials and prescriptions for meson-exchange currents, demonstrate an overall good agreement with data.

Few-body nuclei↗

Supernova neutrino detection in NOvA

The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Fermilab NuMI beam. These detectors are also sensitive to the flux of neutrinos which are emitted during a core-collapse supernova through inverse beta decay interactions on carbon at energies of &calO;(10 MeV). This signature provides a means to study the dominant mode of energy release for a core-collapse supernova occurring in our galaxy. We describe the data-driven software trigger system developed and employed by the NOvA experiment to identify and record neutrino data from nearby galactic supernovae. This technique has been used by NOvA to self-trigger on potential core-collapse supernovae in our galaxy, with an estimated sensitivity reaching out to 10 kpc distance while achieving a detection efficiency of 23% to 49% for supernovae from progenitor stars with masses of 9.6 M⊙ to 27 M⊙, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

Analysis of useful ion yield for the Mg dopant in GaN by quadrupole—SIMS

The authors present a quantitative secondary ion mass spectrometry (SIMS) analysis of the useful ion yield of magnesium dopant in a gallium nitride matrix. A quadrupole SIMS instrument was used to analyze an Mg-doped GaN sample grown by metal organic chemical vapor deposition. Oxygen (O2+) was used as the primary ion beam and its energy was varied in the range from 0.5 to 5 kV with and without oxygen flooding near the sample. The results of the analysis can be used to determine the primary beam energies for optimal magnesium sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

The Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay μ+→e+γ: BR(μ+→e+γ) <4.2×10−13 at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of 6×10−14. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute (7×107 muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

physics beyond the Standard Model↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

Manipulation of the orbital angular momentum of soft X-ray beams by consecutive diffractive optics

Production and manipulation of orbital angular momentum (OAM) of coherent soft X-ray beams is demonstrated utilizing consecutive diffractive optics. OAM addition is observed upon passing the beam through consecutive fork gratings. Here, the OAM of the beam was found to be decoupled from its spin angular momentum (SAM). Practical implementation of angular momentum control by consecutive devices in the X-ray regime opens new experimental opportunities, such as direct measurement of the beam’s OAM without resorting to phase-sensitive techniques, including holography. OAM analyzers utilizing fork gratings can be used to characterize the beams produced by synchrotron and free electron lasers sources; they can also be used in scattering experiments.

36 MATERIALS SCIENCE↗

Development of a pulsed, variable-energy positron beam for atomic scale defect studies

Positron annihilation spectroscopy provides a sensitive means of non-destructive characterization of materials, capable of probing single atom vacancies in solids with 10 –7 sensitivity. Here, in this work, we detail the development of a magnetically guided, variable energy, pulsed positron beam designed to conduct depth-dependent defect studies in metals, semiconductors, and dielectrics, which will be the first of its kind in the United States. The design of the target stage provides capabilities for measurements during in situ annealing up to 800 °C and incorporates a new approach to minimize the background due to energetic backscattered positrons. The developed beam at Bowling Green State University provides a powerful tool for characterization of thin films, devices, and ion irradiated materials.

47 OTHER INSTRUMENTATION↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SECAR: A recoil separator for nuclear astrophysics

Proton-and alpha-capture reactions on unstable proton-rich nuclei power astrophysical explosions like novae and X-ray bursts. Direct measurements of these reactions are crucial for understanding the mechanisms behind these explosions and the nucleosynthesis at such sites. The recoil mass separator, SECAR (SEparator for CApture Reactions) at the National Superconducting Cyclotron Laboratory (NSCL) and the Facility for Rare Isotope Beams (FRIB), has been designed with the required sensitivity to study (p,γ) and (α,γ) reactions, directly at astrophysical energies in inverse kinematics, with radioactive beams of masses up to about A = 65. The complete SECAR system, including two Wien Filters for high mass resolution, has been installed at Michigan State University and is currently being commissioned. The present article introduces the SECAR concept, its scientific goals, and provides an update of the current status of the project.

Tsintari, P↗

Summary of the CeC Experiment in RHIC Run 21

The coherent electron cooling (CeC) experiment at RHIC is crucial for determining the feasibility of this technique for cooling the hadron beam in the electron-ion collider (EIC) and reaching the luminosity of 10 34 cm -1 s -1 . During RHIC Run 21, various progresses have been made including successfully commissioning the time resolved diagnostic beam line (TRDBL), achieving the key performance parameters (KPP) of the system and the development of novel methods for accurate alignment of the electron beam with the ion beam. While the longitudinal cooling of the ion beam with cooling time of 100 hours was observed during Run 21, it was related to the traditional electron cooling since the cooling rate was not as sensitive to the energy of the electron beam as what one would expect from the CeC. In Run 21, we were not able to observe the longitudinal cooling of the ion beam caused by CeC and the main challenges are identified as the insufficient stability of the electrons' energy. The sources of the energy jitter have been identified and we are making improvements to the stability of the CeC system for Run 22.

43 PARTICLE ACCELERATORS↗

Single-beam plasma source deposition of carbon thin films

A single-beam plasma source was developed and used to deposit hydrogenated amorphous carbon (a-C:H) thin films at room temperature. The plasma source was excited by a combined radio frequency and direct current power, which resulted in tunable ion energy over a wide range. The plasma source could effectively dissociate the source hydrocarbon gas and simultaneously emit an ion beam to interact with the deposited film. Using this plasma source and a mixture of argon and C 2 H 2 gas, a-C:H films were deposited at a rate of ~26 nm/min. The resulting a-C:H film of 1.2 µm thick was still highly transparent with a transmittance of over 90% in the infrared range and an optical bandgap of 2.04 eV. Young’s modulus of the a-C:H film was ~80 GPa. The combination of the low-temperature high-rate deposition of transparent a-C:H films with moderately high Young’s modulus makes the single-beam plasma source attractive for many coatings applications, especially in which heat-sensitive and soft materials are involved. Here, the single-beam plasma source can be configured into a linear structure, which could be used for large-area coatings.

14 SOLAR ENERGY↗