Search NASA⌕ Search

SEARCH · Search NASA

Results for “Body Reference Frame”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Internal Structure and Mineralogy of Differentiated Asteroids Assuming Chondritic Bulk Composition: The Case of Vesta

Bulk composition (including oxygen content) is a primary control on the internal structure and mineralogy of differentiated asteroids. For example, oxidation state will affect core size, as well as Mg# and pyroxene content of the silicate mantle. The Howardite-Eucrite-Diogenite class of meteorites (HED) provide an interesting test-case of this idea, in particular in light of results of the Dawn mission which provide information on the size, density and differentiation state of Vesta, the parent body of the HED's. In this work we explore plausible bulk compositions of Vesta and use mass-balance and geochemical modelling to predict possible internal structures and crust/mantle compositions and mineralogies. Models are constrained to be consistent with known HED samples, but the approach has the potential to extend predictions to thermodynamically plausible rock types that are not necessarily present in the HED collection. Nine chondritic bulk compositions are considered (CI, CV, CO, CM, H, L, LL, EH, EL). For each, relative proportions and densities of the core, mantle, and crust are quantified. Considering that the basaltic crust has the composition of the primitive eucrite Juvinas and assuming that this crust is in thermodynamic equilibrium with the residual mantle, it is possible to calculate how much iron is in metallic form (in the core) and how much in oxidized form (in the mantle and crust) for a given bulk composition. Of the nine bulk compositions tested, solutions corresponding to CI and LL groups predicted a negative metal fraction and were not considered further. Solutions for enstatite chondrites imply significant oxidation relative to the starting materials and these solutions too are considered unlikely. For the remaining bulk compositions, the relative proportion of crust to bulk silicate is typically in the range 15 to 20% corresponding to crustal thicknesses of 15 to 20 km for a porosity-free Vesta-sized body. The mantle is predicted to be largely dominated by olivine (>85%) for carbonaceous chondrites, but to be a roughly equal mixture of olivine and pyroxene for ordinary chondrite precursors. All bulk compositions have a significant core, but the relative proportions of metal and sulphide can be widely different. Using these data, total core size (metal+ sulphide) and average core densities can be calculated, providing a useful reference frame within which to consider geophysical/gravity data of the Dawn mission.

Toplis, M. J.↗

Chondritic Models of 4 Vesta: Comparison of Data from the Dawn Mission with Predicted Internal Structure and Surface Composition/Mineralogy

While the HEDs provide an extremely useful basis for interpreting data from the Dawn mission, there is no guarantee that they provide a complete vision of all possible crustal (and possibly mantle) lithologies that are exposed at the surface of Vesta. With this in mind, an alternative approach is to identify plausible bulk compositions and use mass-balance and geochemical modelling to predict possible internal structures and crust/mantle compositions and mineralogies. While such models must be consistent with known HED samples, this approach has the potential to extend predictions to thermodynamically plausible rock types that are not necessarily present in the HED collection. Nine chondritic bulk compositions are considered (CI, CV, CO, CM, H, L, LL, EH, EL). For each, relative proportions and densities of the core, mantle, and crust are quantified. This calculation is complicated by the fact that iron may occur in metallic form (in the core) and/or in oxidized form (in the mantle and crust). However, considering that the basaltic crust has the composition of Juvinas and assuming that this crust is in thermodynamic equilibrium with the residual mantle, it is possible to calculate a single solution to this problem for a given bulk composition. Of the nine bulk compositions tested, solutions corresponding to CI and LL groups predicted a negative metal fraction and were not considered further. Solutions for enstatite chondrites imply significant oxidation relative to the starting materials and these solutions too are considered unlikely. For the remaining bulk compositions, the relative proportion of crust to bulk silicate is typically in the range 15 to 20% corresponding to crustal thicknesses of 15 to 20 km for a porosity-free Vesta-sized body. The mantle is predicted to be largely dominated by olivine (greater than 85%) for carbonaceous chondrites, but to be a roughly equal mixture of olivine and pyroxene for ordinary chondrite precursors. All bulk compositions have a significant core, but the relative proportions of metal and sulphide can be widely different. Using these data, total core size (metal+ sulphide) and average core densities can be calculated, providing a useful reference frame within which to consider geophysical/gravity data of the Dawn mission. Further to these mass-balance calculations, the MELTS thermodynamic calculator has been used to assess to what extent chondritic bulk compositions can produce Juvinas-like liquids at relevant degrees of partial melting/crystallization. This work will refine acceptable bulk compositions and predict the mineralogy and composition of the associated solid and liquid products over wide ranges of partial melting and crystallization, providing a useful and self-consistent reference frame for interpretation of the data from the VIR and GRaND instruments onboard the Dawn spacecraft.

Toplis, M. J.↗

Artificial gravity as a countermeasure in long-duration space flight

Long-duration exposure to weightlessness results in bone demineralization, muscle atrophy, cardiovascular deconditioning, altered sensory-motor control, and central nervous system reorganizations. Exercise countermeasures and body loading methods so far employed have failed to prevent these changes. A human mission to Mars might last 2 or 3 years and without effective countermeasures could result in dangerous levels of bone and muscle loss. Artificial gravity generated by rotation of an entire space vehicle or of an inner chamber could be used to prevent structural changes. Some of the physical characteristics of rotating environments are outlined along with their implications for human performance. Artificial gravity is the centripetal force generated in a rotating vehicle and is proportional to the product of the square of angular velocity and the radius of rotation. Thus, for a particular g-level, there is a tradeoff between velocity of rotation and radius. Increased radius is vastly more expensive to achieve than velocity, so it is important to know the highest rotation rates to which humans can adapt. Early studies suggested that 3 rpm might be the upper limit because movement control and orientation were disrupted at higher velocities and motion sickness and chronic fatigue were persistent problems. Recent studies, however, are showing that, if the terminal velocity is achieved over a series of gradual steps and many body movements are made at each dwell velocity, then full adaptation of head, arm, and leg movements is possible. Rotation rates as high as 7.5-10 rpm are likely feasible. An important feature of the new studies is that they provide compelling evidence that equilibrium point theories of movement control are inadequate. The central principles of equilibrium point theories lead to the equifinality prediction, which is violated by movements made in rotating reference frames. Copyright 2000 Wiley-Liss, Inc.

Review Literature↗

WE-AB-303-07: Computational Monitoring Framework of Four-Dimensional Dose Distributions During Treatment Time Based On a 2D/3D Registration with Adaptive Transformation Parameters in Lung Stereotactic Body Radiotherapy

Purpose: The aim of this study was to develop a computational framework for monitoring four-dimensional (4D) dose distributions during treatment time based on a 2D/3D registration with adaptive transformation parameters (ATPs) in lung stereotactic body radiotherapy (SBRT). Methods: The 4D dose distributions during the SBRT were calculated by applying a pencil beam convolution (PBC) algorithm to simulated 4D-computed tomography (CT) images during treatment time (hereinafter referred to as “treatment” 4D-CT images). The “treatment” 4D-CT images were derived by deforming 3D planning CT images by using transformation parameters so that 2D planning portal dose images (PDIs) can resemble 2D dynamic clinical PDIs in each frame, which were derived from electronic portal imaging device (EPID) images. The transformation parameters were optimized by the Levenberg- Marquardt (LM) algorithm. The optimized transformation parameters in a certain frame were adaptively employed as initial transformation parameters for optimization of the parameters in the consecutive frame. Gamma pass rates (3mm/3%) between dynamic clinical PDIs and dynamic “treatment” PDIs derived from the “treatment” 4D-CT images were measured for comparing the proposed frameworks without and with the ATPs. These proposed frameworks were applied to the EPID dynamic images (40 frames) of two patients with lung cancer, who underwent the SBRT. Results: Gamma pass rates without and with the ATPs were 83.01±4.42% and 89.31±3.18% on average, respectively (p<0.05). Moreover, percentage errors between prescribed doses and estimated doses at an isocenter by the proposed frameworks without and with the ATPs were 10.67±5.66% and 6.34±0.47% on average, respectively (p<0.05). Conclusion: The proposed framework with ATPs could be useful to ensure the quality of the SBRT by monitoring 4D dose distributions during treatment time.

60 APPLIED LIFE SCIENCES↗

Astrometry of Cassini with the VLBA to improve the Saturn ephemeris

Planetary ephemerides have been developed and improved over centuries. They are a fundamental tool for understanding solar system dynamics, and essential for planetary and small body mass determinations, occultation predictions, high-precision tests of general relativity, pulsar timing, and interplanetary spacecraft navigation. This paper presents recent results from a continuing program of high-precision astrometric very long baseline interferometry (VLBI) observations of the Cassini spacecraft orbiting Saturn, using the Very Long Baseline Array (VLBA). We have previously shown that VLBA measurements can be combined with spacecraft orbit determinations from Doppler and range tracking and VLBI links to the inertial extragalactic reference frame to provide the most accurate barycentric positions currently available for Saturn. Here we report an additional five years of VLBA observations along with improved phase reference source positions, resulting in an improvement in residuals with respect to the Jet Propulsion Laboratory's dynamical ephemeris.

79 ASTRONOMY AND ASTROPHYSICS↗

First Road / River Barge Security Transport of SNF under the New German Transport Security Guidelines - 19102

A transfer of 342 spent fuel assemblies from NPP Obrigheim to NPP Neckarwestheim, both located alongside the river Neckar in the south of Germany, is required to promote the decommissioning process of NPP Obrigheim, which started in 2008 after the NPP had been shut down three years before. The spent fuel storage facility in Neckarwestheim offers sufficient storage space to accept the 342 SNF assemblies, stored in fifteen dry casks type CASTOR{sup R} 440/84 mvK. After several transport feasibility studies had been conducted, Daher Nuclear Technologies GmbH was awarded the commission to plan, prepare and conduct the SNF transport. Since the combined road / river barge transport promised to be the most suitable mode of transportation Daher Nuclear Technologies started to prepare its security concept, a prerequisite to apply for and attain the transport license mandatory for transporting spent nuclear fuel in Germany. In March 2014 the company applied for the transport license, which, after more than three years and numerous amendments to the security concept, was finally granted to Daher Nuclear Technologies on May 16, 2017 by the German Federal Office for the Safety of Nuclear Waste Management (successor organization of the BfS). Simultaneously to the license application phase the transport equipment - amongst others the heavy-duty trucks and trailers, the pusher tugs, the river barge and transport frames - had to be provided and modified to meet the intensified requirements of the New German Transport Security Guidelines Road / Rail as well as several other legal regulations referring to the transport of dangerous goods by road and inland waterways (e.g. ADR - European Agreement concerning the International Carriage of Dangerous Goods by Road and ADN - European Agreement concerning the International Carriage of Dangerous Goods by Inland Waterways). The planning process involved various meetings with representatives of different authorities and administrative bodies incl. accredited experts as well as subcontractors. Tremendous training efforts had to be undertaken to train more than 100 transport participants regarding security measures, health, safety and environmental measures, as well as the proper handling of radioactive material. This also included the training of the security staff, that had to be qualified in compliance with the new Transport Security Guidelines Road and Rail. Finally, in June 2017, when all preparations where complete, all requirements met, and all permits obtained, the first ever security SNF transport on a German river was performed. Three laden CASTOR{sup R} 440/84 mvK transport and storage casks were transported in one batch via heavy-duty truck-trailer from the NPP Obrigheim to the NPP's own harbor, to be rolled on to the river barge, that would carry the three casks upstream the river Neckar to the approx. fifty kilometer distant NPP Neckarwestheim. The journey on the river took about eleven hours, in which several bridges and locks had to be passed. The entire transport was escorted by qualified security staff and auxiliary police forces on waterways and alongside on roads. It attracted nationwide public attention, due to its pioneer status and the fact, that there hadn't been any SNF or HLW shipments in Germany since 2011. After the convoy safely arrived at NPP Neckarwestheim's pier the three laden CASTOR{sup R} 440/84 mvK casks were rolled off the river barge via heavy-duty truck-trailers to be stored in the on-site interim storage facility. This first transport was a success and was followed by four additionally successful security transports in September, October, November and December 2017. The public attention receded significantly during the transport campaign, which ended on December 19, 2017 with the transfer of the last three of fifteen casks to the on-site interim storage facility in Neckarwestheim. With the last cask safely transferred to the interim storage facility Daher Nuclear Technologies successfully completed the transport campaign on schedule, meeting one of EnBW's fundamental objectives to finish the transfer of the 342 SNF assemblies by the end of 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the flight dynamics of the Solar Maximum Mission (SMM) off-sun scientific pointing

Algorithms are presented which were created and implemented by the Goddard Space Flight Center's (GSFC's) Solar Maximum Mission (SMM) attitude operations team to support large-angle spacecraft pointing at scientific objectives. The mission objective of the post-repair SMM satellite was to study solar phenomena. However, because the scientific instruments, such as the Coronagraph/Polarimeter (CP) and the Hard X ray Burst Spectrometer (HXRBS), were able to view objects other than the Sun, attitude operations support for attitude pointing at large angles from the nominal solar-pointing attitudes was required. Subsequently, attitude support for SMM was provided for scientific objectives such as Comet Halley, Supernova 1987A, Cygnus X-1, and the Crab Nebula. In addition, the analysis was extended to include the reverse problem, computing the right ascension and declination of a body given the off-Sun angles. This analysis led to the computation of the orbits of seven new solar comets seen in the field-of-view (FOV) of the CP. The activities necessary to meet these large-angle attitude-pointing sequences, such as slew sequence planning, viewing-period prediction, and tracking-bias computation are described. Analysis is presented for the computation of maneuvers and pointing parameters relative to the SMM-unique, Sun-centered reference frame. Finally, science data and independent attitude solutions are used to evaluate the large-angle pointing performance.

Pitone, D. S.↗

Analysis of the flight dynamics of the Solar Maximum Mission (SMM) off-sun scientific pointing

Algorithms are presented which were created and implemented by the Goddard Space Flight Center's (GSFC's) Solar Maximum Mission (SMM) attitude operations team to support large-angle spacecraft pointing at scientific objectives. The mission objective of the post-repair SMM satellite was to study solar phenomena. However, because the scientific instruments, such as the Coronagraph/Polarimeter (CP) and the Hard X-ray Burst Spectrometer (HXRBS), were able to view objects other than the Sun, attitude operations support for attitude pointing at large angles from the nominal solar-pointing attitudes was required. Subsequently, attitude support for SMM was provided for scientific objectives such as Comet Halley, Supernova 1987A, Cygnus X-1, and the Crab Nebula. In addition, the analysis was extended to include the reverse problem, computing the right ascension and declination of a body given the off-Sun angles. This analysis led to the computation of the orbits of seven new solar comets seen in the field-of-view (FOV) of the CP. The activities necessary to meet these large-angle attitude-pointing sequences, such as slew sequence planning, viewing-period prediction, and tracking-bias computation are described. Analysis is presented for the computation of maneuvers and pointing parameters relative to the SMM-unique, Sun-centered reference frame. Finally, science data and independent attitude solutions are used to evaluate the larg-angle pointing performance.

Pitone, D. S.↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗

Geometric frustration induces the transition between rotation and counterrotation in swirled granular media

Granular material in a swirled container exhibits a curious transition as the number of particles is increased: At low densities, the particle cluster rotates in the same direction as the swirling motion of the container, while at high densities it rotates in the opposite direction. We investigate this phenomenon experimentally and numerically using a corotating reference frame in which the system reaches a statistical steady state. In this steady state, the particles form a cluster whose translational degrees of freedom are stationary, while the individual particles constantly circulate around the cluster's center of mass, similar to a ball rolling along the wall within a rotating drum. We show that the transition to counterrotation is friction dependent. At high particle densities, frictional effects result in geometric frustration, which prevents particles from cooperatively rolling and spinning. Consequently, the particle cluster rolls like a rigid body with no-slip conditions on the container wall, which necessarily counterrotates around its own axis. Furthermore, numerical simulations verify that both wall-disk friction and disk-disk friction are critical for inducing counterrotation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bubble migration in a rotating, liquid-filled sphere

Results and analysis of ground-based experiments performed to aid in designing experiments on the behavior of bubbles in a rotating liquid body on board the Shuttle in free fall are presented. Spherical shells filled with silicone oil containing a small gas bubble were spun and filmed by high speed motion picture photography. The rotation of the shell and the trajectory of the bubble motion were recorded and the film was exposed to a motion analyzer connected to a keypunch. The analyzer measured Cartesian coordinates as well as angle, frame number, and rotation rate. Optical correction equations were employed to determine the apparent bubble trajectory relative to an inertial frame of reference. An analytical model for the bubble motion was defined, yielding predictions of velocity and position at different times. Rotation of the fluid container is concluded to aid in centering the bubbles.

Annamalai, P.↗

The optimum shape for a rigid rotating shell enclosing an isotropic spherical planetary mass

Analysis of the Dyson Sphere, an extremely advanced civilization's hypothetical construct entirely surrounding a star, shows that new stress inward to the star increases to maxima at the poles if the sphere is rotating. This is because the centrifugal force in the rotating frame of reference vanishes at zero rotational radius, which occurs at the poles. There is less of the centrifugal force at high latitudes than low to offset the star's gravity. A form is derived for a thin, rigid, rotating shell, surrounding a large pointlike mass and/or charge, which will experience the least possible net stress at every point upon it - a shape on which every point not on the shell's equator is as near as possible to being in orbit. In orbit, whose plane passes through the primary body's center of mass or of charge, F(grav), or Fg, is exactly opposite in direction to F(centrif), or Fc, and is equal in amount. At all points not on the equator, Fc will not entirely offset Fg, because of Fg's vector decomposition. However, both forces are always constrained to be equal in absolute amount everywhere on the shell, equator included. The derived shape, given by the figure of revolution around the x-axis of x = square root (y-1-72), will prove useful in large-scale space construction. Also, various engineering problems are discussed.

Covington, Tatiana↗

Camera Calibration and Alignment Metrology at Johnson Space Center’s Electro-Optics Laboratory

It is increasingly common to see spacecraft equipped with cameras for the purpose of navigation. Images are either sent to Earth or processed autonomously on-board to provide information about the vehicle’s position, velocity, and/or attitude. These can be images of stars or celestial bodies for absolute navigation, or images of another spacecraft for relative navigation. While monocular cameras do not provide range information, the images they capture can be processed to determine bearing vectors to target objects within the camera’s field of view. For a camera to be effective in navigation, it must be carefully calibrated and aligned. This involves accurately modeling the optical effects that govern the projection of line-of-sight directions onto the camera’s pixels and determining the camera’s orientation relative to the spacecraft’s reference frame. Engineers at Johnson Space Center’s Electro-Optics Lab regularly perform camera inspection, calibration, and alignment metrology. This was done for the Orion Optical Navigation (OpNav) Camera, the Orion Docking Camera (DCAM), and for numerous cameras belonging to commercial partners. The nature of optical navigation means that cameras must be well-calibrated and their attitude well understood to provide high accuracy bearing measurements to the navigation filter. The stringent accuracy requirements for Orion could not have been met using traditional checkerboard camera calibration or by simply relying on design drawings. This paper details the hardware, software, techniques, and algorithms used by the EOL team to achieve this level of accuracy.

Paul D Mckee↗

Camera Calibration and Alignment Metrology at Johnson Space Center’s Electro-Optics Laboratory

It is increasingly common to see spacecraft equipped with cameras for the purpose of navigation. Images are either sent to Earth or processed autonomously on-board to provide information about the vehicle’s position, velocity, and/or attitude. These can be images of stars or celestial bodies for absolute navigation, or images of another spacecraft for relative navigation. While monocular cameras do not provide range information, the images they capture can be processed to determine bearing vectors to target objects within the camera’s field of view. For a camera to be effective in navigation, it must be carefully calibrated and aligned. This involves accurately modeling the optical effects that govern the projection of line-of-sight directions onto the camera’s pixels and determining the camera’s orientation relative to the spacecraft’s reference frame. Engineers at Johnson Space Center’s Electro-Optics Lab regularly perform camera inspection, calibration, and alignment metrology. This was done for the Orion Optical Navigation (OpNav) Camera, the Orion Docking Camera (DCAM), and for numerous cameras belonging to commercial partners. The nature of optical navigation means that cameras must be well-calibrated and their attitude well understood to provide high accuracy bearing measurements to the navigation filter. The stringent accuracy requirements for Orion could not have been met using traditional checkerboard camera calibration or by simply relying on design drawings. This paper details the hardware, software, techniques, and algorithms used by the EOL team to achieve this level of accuracy.

Paul McKee↗

ON THE MAGNETIZATION OF COSMIC OUTFLOWS: PLASMA MODES AND INSTABILITIES OF UNMAGNETIZED PLASMA BEAMS

The dissipation of the kinetic energy of cosmic outflows in interactions with ambient collision-free plasmas and the associated generation of electromagnetic plasma turbulence is a fundamental problem of modern astrophysics. Thermalization by elastic two-body Coulomb collisions is orders of magnitudes too slow as compared to interactions with electric and magnetic fields because of the generally low density of cosmic plasmas. Alternative dissipation mechanisms have to be examined such as energy diffusion by second-order Fermi interactions of charged particles with electromagnetic turbulence, which are an intrinsic property of any sufficiently agitated magnetized plasma. We consider the microphysical details of the energy conversion in relativistic and nonrelativistic outflows by investigating the solutions of the linear plasma dispersion relation in an unmagnetized anisotropic beam plasma consisting of two overall-neutral particle beams propagating with arbitrary velocities in the same direction. The general plasma dispersion relation is derived for arbitrary propagation angle {theta} with respect to the beam propagation direction both in the initial laboratory frame and in the counterstream frame of reference. Solutions of the linear dispersion relation are derived for parallel ({theta} = {pi}/2) and perpendicular ({theta} = 0) propagation angle, respectively. For parallel propagation angles, the electrostatic mode is excited and its maximum growth rate depends on the relative bulk Lorentz factor of the flows and their density ratio. For perpendicular propagation angles, the aperiodic filamentation mode is excited and its maximum growth rate depends differently on the relative bulk Lorentz factor of the flow and their density ratio. The respective maximum growth rates indicate that for nonrelativistic flow velocities the electrostatic instability (EI) is excited much faster than the filamentation instability (FI), whereas for relativistic flow velocities the FI has a larger growth rate than the EI. This implies that nonrelativistic flows dissipate their kinetic energy predominantly in electric fields associated with the electrostatic mode, while relativistic flows dissipate their kinetic energy predominantly in magnetic fields. Therefore, initially unmagnetized relativistic flows are more effectively magnetized than initially unmagnetized nonrelativistic flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wave function for harmonically confined electrons in time-dependent electric and magnetostatic fields

We derive via the interaction “representation” the many-body wave function for harmonically confined electrons in the presence of a magnetostatic field and perturbed by a spatially homogeneous time-dependent electric field—the Generalized Kohn Theorem (GKT) wave function. In the absence of the harmonic confinement – the uniform electron gas – the GKT wave function reduces to the Kohn Theorem wave function. Without the magnetostatic field, the GKT wave function is the Harmonic Potential Theorem wave function. We further prove the validity of the connection between the GKT wave function derived and the system in an accelerated frame of reference. Finally, we provide examples of the application of the GKT wave function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures

Purpose: To investigate the radiation exposure in non-vascular fluoroscopy guided interventions and to search strategies for dose reduction. Materials and Methods: Dose area product (DAP) of 638 consecutive non-vascular interventional procedures of one year were analyzed with respect to different types of interventions; gastrointestinal tract, biliary interventions, embolizations of tumors and hemorrhage. Data was analyzed with special focus on the fluoroscopy doses and frame doses. The third quartiles (Q3) of fluoroscopy dose values were defined in order to set a reference value for our in-hospital practice. Results: Mean fluoroscopy times of gastrostomy, jejunostomy, right and left sided percutaneous biliary drainage, chemoembolization of the liver and embolization due to various hemorrhages were 5.9, 8.6, 13.5, 16.6, 17.4 and 25.2 min, respectively. The respective Q3 total DAP were 52.9, 73.3, 155.1, 308.4, 428.6 and 529.3 Gy*cm{sup 2}. Overall, around 66% of the total DAP originated from the radiographic frames with only 34% of the total DAP applied by fluoroscopy (P < 0.001). The investigators experience had no significant impact on the total DAP applied, most likely since there was no stratification to intervention-complexity. Conclusion: To establish Diagnostic Reference Levels (DRLs), there is a need to establish a registry of radiation dose data for the most commonly performed procedures. Documentation of interventional procedures by fluoroscopy 'grabbing' has the potential to considerably reduce radiation dose applied and should be used instead of radiographic frames whenever possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images

Purpose: To evaluate the geometric accuracy of beam targeting in external surrogate-based gated volumetric modulated arc therapy (VMAT) using kilovoltage (kV) x-ray images acquired during dose delivery. Methods: Gated VMAT treatments were delivered using a Varian TrueBeam STx Linac for both physical phantoms and patients. Multiple gold fiducial markers were implanted near the target. The reference position was created for each implanted marker, representing its correct position at the gating threshold. The gating signal was generated from the RPM system. During the treatment, kV images were acquired immediately before MV beam-on at every breathing cycle, using the on-board imaging system. All implanted markers were detected and their 3D positions were estimated using in-house developed software. The positioning error of a marker is defined as the distance of the marker from its reference position for each frame of the images. The overall error of the system is defined as the average over all markers. For the phantom study, both sinusoidal motion (1D and 3D) and real human respiratory motion was simulated for the target and surrogate. In the baseline case, the two motions were synchronized for the first treatment fraction. To assess the effects of surrogate-target correlation on the geometric accuracy, a phase shift of 5% and 10% between the two motions was introduced. For the patient study, intrafraction kV images of five stereotactic body radiotherapy (SBRT) patients were acquired for one or two fractions. Results: For the phantom study, a high geometric accuracy was achieved in the baseline case (average error: 0.8 mm in the superior-inferior or SI direction). However, the treatment delivery is prone to geometric errors if changes in the target-surrogate relation occur during the treatment: the average error was increased to 2.3 and 4.7 mm for the phase shift of 5% and 10%, respectively. Results obtained with real human respiratory curves show a similar trend. For a target with 3D motion, the technique is able to detect geometric errors in the left-right (LR) and anterior-posterior (AP) directions. For the patient study, the average intrafraction positioning errors are 0.8, 0.9, and 1.4 mm and 95th percentile errors are 1.7, 2.1, and 2.7 mm in the LR, AP, and SI directions, respectively. Conclusions: The correlation between external surrogate and internal target motion is crucial to ensure the geometric accuracy of surrogate-based gating. Real-time guidance based on kV x-ray images overcomes the potential issues in surrogate-based gating and can achieve accurate beam targeting in gated VMAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗