Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bone Density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

OpenSim Model Improvements to Support High Joint Angle Resistive Exercising

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Rigorous testing of these proposed devices in space flight is difficult so computational modeling provides an estimation of the muscle forces and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts

Bioengineering↗

Utilizing Commercial Hardware and Open Source Computer Vision Software to Perform Motion Capture for Reduced Gravity Flight

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts. To perform validation of these models and to support the Advanced Exercise Concepts Project, several candidate devices have been flown onboard NASAs Reduced Gravity Aircraft. In terrestrial laboratories, researchers typically have available to them motion capture systems for the measurement of subject kinematics. Onboard the parabolic flight aircraft it is not practical to utilize the traditional motion capture systems due to the large working volume they require and their relatively high replacement cost if damaged. To support measuring kinematics on board parabolic aircraft, a motion capture system is being developed utilizing open source computer vision code with commercial off the shelf (COTS) video camera hardware. While the systems accuracy is lower than lab setups, it provides a means to produce quantitative comparison motion capture kinematic data. Additionally, data such as required exercise volume for small spaces such as the Orion capsule can be determined. METHODS: OpenCV is an open source computer vision library that provides the ability to perform multi-camera 3 dimensional reconstruction. Utilizing OpenCV, via the Python programming language, a set of tools has been developed to perform motion capture in confined spaces using commercial cameras. Four Sony Video Cameras were intrinsically calibrated prior to flight. Intrinsic calibration provides a set of camera specific parameters to remove geometric distortion of the lens and sensor (specific to each individual camera). A set of high contrast markers were placed on the exercising subject (safety also necessitated that they be soft in case they become detached during parabolic flight); small yarn balls were used. Extrinsic calibration, the determination of camera location and orientation parameters, is performed using fixed landmark markers shared by the camera scenes. Additionally a wand calibration, the sweeping of the camera scenes simultaneously, was also performed. Techniques have been developed to perform intrinsic calibration, extrinsic calibration, isolation of the markers in the scene, calculation of marker 2D centroids, and 3D reconstruction from multiple cameras. These methods have been tested in the laboratory side-by-side comparison to a traditional motion capture system and also on a parabolic flight.

Biodynamics↗

Biomechanical Modeling of the Deadlift Exercise on the HULK Device to Improve the Efficacy of Resistive Exercise Microgravity Countermeasures

Extended spaceflight typically results in the loss of muscular strength and bone density due to exposure to microgravity. Resistive exercise countermeasures have been developed to maintain musculoskeletal health during spaceflight. The Advanced Resistive Exercise Device (ARED) is the "gold standard" of available devices; however, its footprint and volume are too large for use in space capsules employed in exploration missions. The Hybrid Ultimate Lifting Kit (HULK) device, with its smaller footprint, is a prototype exercise device for exploration missions. This work models the deadlift exercise being performed on the HULK device using biomechanical simulation, with the long-term goal to improve and optimize astronauts' exercise prescriptions, to maximize the benefit of exercise while minimizing time and effort invested.

Countermeasures↗

Squat Biomechanical Modeling Results from Exercising on the Hybrid Ultimate Lifting Kit

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. The computational models currently under development utilize the OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from test subjects for estimation of muscle and joint loads. The subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. Test variables include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data is also obtained using free weights for a comparison to the resistively loaded exercise device. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. The focus of this presentation is to summarize the results from the full squat exercises across the different test variables.

Bioengineering↗

Biomechanical Modeling of Split-leg Squat and Heel Raise on the Hybrid Ultimate Lifting Kit (HULK)

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and musculoskeletal forces that occur during exercises performed on the prototype devices. Computational models currently use OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from subjects for estimation of muscle and joint loads. Subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the loads on the body. Multiple exercises are performed and evaluated during a test session such as a full squat, single leg squat, heel raise and dead lift. Variables for these exercises include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data from free weights are compared to the resistively loaded exercise device. The focus of this presentation is to summarize the results from the single-leg squat and heel raise exercises performed during three sessions occurring in 2015. Differences in loading configuration, cadence and stance produce differences in kinematics, joint toques and force and muscle forces.

computational modeling↗

Biomechanical Modeling Analysis of Loads Configuration for Squat Exercise

INTRODUCTION: Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to assist loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft for travel to the Moon or to Mars is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and the musculoskeletal forces that occur during exercises performed on the prototype devices. METHODS The computational models currently under development utilize the OpenSim [1] software platform, consisting of open source code for musculoskeletal modeling, using biomechanical input data from test subjects for estimation of muscle and joint loads. The OpenSim Full Body Model [2] is used for all analyses. The model incorporates simplified wrap surfaces, a new knee model and updated lower body muscle parameters derived from cadaver measurements and magnetic resonance imaging of young adults. The upper body uses torque actuators at the lumbar and extremity joints. The test subjects who volunteer for this study are instrumented with reflective markers for motion capture data collection while performing squat exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device (ZIN Technologies, Middleburg Heights, OH). Ground reaction force data is collected with force plates under the feet, and device loading is recorded through load cells internal to the HULK. Test variables include the applied device load and the dual cable long bar or single cable T-bar interface between the test subject and the device. Data is also obtained using free weights with the identical loading for a comparison to the resistively loaded exercise device trials. The data drives the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the body loads. RESULTS Lower body kinematics, joint moments, joint forces and muscle forces are obtained from the OpenSim biomechanical analysis of the squat exercises under different loading conditions. Preliminary results from the model for the loading conditions will be presented as will hypotheses developed for follow on work.

Human Factors Engineering↗

Closed Loop Control Compact Exercise Device for Use on MPCV

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. To combat spaceflight physiological deconditioning, astronauts will use resistive and aerobic exercise regimens for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the mass and volume available for an exercise device in the next generation of spacecraft is limited. Therefore, compact exercise device prototypes are being developed for human in the loop evaluations. The NASA Human Research Program (HRP) is managing Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation for all exploration mission profiles from Multi-Purpose Crew Vehicle (MPCV) exploration missions (e.g., EM-2, up to 21 day) to Mars Transit (up to 1000 day) missions. Numerous technologies have been considered and evaluated against HRP-approved functional requirements and include flywheel, pneumatic and closed-loop microprocessor-controlled motor driven power plants. Motor driven technologies offer excellent torque density and load accuracy characteristics as well as the ability to create custom mechanical impedance (the dynamic relationship between force and velocity) and custom load versus position exercise algorithms. Further, closed-loop motor-driven technologies offer the ability to monitor exercise dose parameters and adapt to the needs of the crewmember for real time optimization of exercise prescriptions. A simple proportional-integral-derivative (PID) controller is demonstrated in a prototype motor driven exercise device with comparison to resistive static and dynamic load set points and aerobic work rate targets. The resistive load term in the algorithm includes a constant force component (Fcmg) as well as inertial component (Fima) and a discussion of system tuning is presented in terms of addressing key functional requirements and human interfaces. The device aerobic modality is modelled as a rowing exercise using ground data sets obtained from Concept 2 rowers as well as competitive rowing1. A discussion of software and electronic implementations are presented which demonstrate unique approaches to meeting the constrained mass, volume and power requirements of the MPCV. . In addition to utilizing traditional PID control, controllers utilizing state feedback with gains solved using a Linear Quadratic Regulator will be developed. Controllability and observability will be utilized to investigate the need for state measurement in the design. As the control system directly interacts with human test subjects, robust methods such as H-infinity are also being investigated.1. Kleshnev V. Biomechanics. In: Rowing, Handbook of Sports Medicine and Science. ed. by Secher N., Voliantis S. IOC Medical Commission, Blackwell Pub. pp. 22-34, 2007

microgravity↗

In-Space Inspection Needs: Opportunities for advanced NDE tools such as x-ray CT for additively manufactured parts, in-situ resource utilization, geological applications, and more

It is now 50 years since the first human presence on the surface of the Moon and as we strive to return with women and men in the next few years, we embrace new technical challenges, goals, and innovative solutions to address 21st century objectives. These new ambitions carry fresh challenges and risks, with the field of NDE playing an increasingly more relevant role towards meeting these essential goals. In recent years, more advanced NDE tools have triggered a rapid expansion of applications for the space industry. In particular, x-ray Computed Tomography (CT) has proven to be a trusted and powerful asset for spaceflight hardware inspection, as well as applied geotechnical analysis for natural materials (e.g., rocks, soils) for NASA and across industry. However, such methods have yet to be extended to “deep space” applications such as those that are now part of the US National Space Policy Directive (SPD-1) and the accelerated push to return humans to the Moon (i.e., Artemis). For this reason, advancing these powerful Earth-based laboratory methods via new technologies, integrated computational solutions, and creative engineering approaches is directly aligned with national space policies, as well as with multiple NASA Strategic Plan priorities. The use of x-ray CT at scales as fine as a few microns or smaller can identify spacecraft part failure modes relevant to quality assurance for flight hardware and AM parts such as those recently developed for ISS. This technology could also identify valuable metallic phases within geological materials (i.e., rocks or drill cores), enabling resource-relevant triage of samples for In-Situ Resource Utilization (ISRU) and high science value sample return to Earth laboratories. There is also significant application for 3D imaging tools for medical use such as inspecting protective gear as well as bone density degradation studies which are critical in establishing a sustained presence in space. Timing for development of these tools for space use is advantageous as we prepare for new opportunities in the next few years and recognize recent commercial technology advancements which make it feasible. Moreover, as NASA strives to take full advantage of developments in AM technologies, including In-Space Manufacturing (ISM), it is widely recognized that NDE tools such as CT will play an essential role in acceptance of these parts for widespread use. New in-space 3D inspection tools with complimentary technology such as AI-based automated feature recognition (accelerated by machine learning), rapid compositional analysis, and advanced sample manipulation, would be a game-changing step toward a new class of crew-based laboratory sensors once human outposts on the Moon are established.

In-Space Non-Destructive Evaluation↗

Risk of Impaired Performance Due to Reduced Muscle Mass, Strength &, Endurance (Short Title: Muscle) and Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity (Short Title: Aerobic)

This report reviews the scientific literature regarding the human system risks to the microgravity environment of space flight in relation to human performance. The primary human performance-related risks involve deconditioning of the cardiovascular and skeletal muscles systems due to prolonged exposure to the reduced gravitational input. The chronological history of U.S. space flight is reviewed as a starting point to inform and understand the gaps in the knowledge to these risks. Maintenance of physical performance capabilities involves understanding the health of many organ systems (peripheral [vascular, heart, blood volume, skeletal muscle] and central [brain]) that ultimately contribute to the submaximal and maximal capacity of the aerobic (VO2peak), skeletal muscle (strength and endurance) systems. Maintaining astronaut VO2peak, muscle mass, strength, and endurance before, during, and after space flight is a significant priority to NASA for the current International Space Station (ISS) era, as well as for future exploration missions. A growing research database from both space flight and ground-based analog studies finds that the cardiorespiratory system is compromised and skeletal muscles (predominantly postural muscles of the lower limbs) undergo atrophy. These structural and metabolic responses to living in microgravity conditions contribute to physiological deconditioning during space flight that potentially increase the risks to astronauts returning to surface operations (i.e., Moon, Mars, or Earth). The time course changes from short to long-duration space flight and the relationships between in-flight performance deconditioning levels are not well characterized. Moreover, there are large interindividual variabilities that may be dependent on genetics, age, sex, preflight fitness levels, and individual exercise prescriptions that need further careful evaluations. Efforts should be made to understand the current status of preflight, in-flight, and postflight exercise performance capability and to define the operational goals and target areas for protection with the in-flight exercise program. There is a bi-directional relationship between exercise prescription and hardware countermeasures that need further understanding in-flight. For example, hardware with limited capabilities/modalities may be counterbalanced by changes in exercise prescription (i.e., frequency, time, intensity, volume) for providing effective responses to maintain fitness. Importantly, the minimal requirements for exercise prescription on ISS hardware may not translate to lower capability hardware on exploration missions. Due to limited volume on exploration vehicles, future Artemis missions to the Lunar surface will not have similar exercise hardware capabilities as ISS. This may alter the effectiveness of hardware to provide adequate physiological stress on bodily systems allowing for adaptations to maintain aerobic capacity, strength, and bone density. Thus, it will be important to understand the exercise responses of current ISS countermeasures to develop individualized exercise prescriptions that minimize aerobic and muscular risks, accounting for the large variability of responses among crewmembers. Newer exploration exercise hardware is currently being evaluated that is more compact (i.e., E4D and Orion Flywheel) and will require careful evaluation of the hardware on the stressor (i.e., metabolic rate, oxygen uptake, and heart rate work relationships, and force plate load profiles) needed the human body to protect and maintain crew health and performance. Moreover, exercise responses on the hardware need careful evaluation on the chronic adaptations. Lastly, in-flight evaluation of hardware exercise response may differ in 0-g or partial-g compared to 1-g. Therefore, it cannot be assumed that the stress on the body will be the same in each environment. Understanding this has a direct impact on exercise prescriptions. This document provides an overview of key scientific investigations that have been conducted before, during, and after human space flight missions, as well as from human ground-based analog studies that contribute to the evidence base on changes in aerobic capacity and muscle mass, strength, and endurance. Additional data from rodent and nonhuman primate experiments of skeletal muscle unloading completed during space flight or ground-based flight-simulations provide supportive information about this risk topic. Most importantly, a recent, large dataset from long-duration ISS crew has been added to give improved insight into the variability of exercise response of crew, demonstrating that a large portion of the crew population return to Earth with greater than 10-20% loss of aerobic capacity and muscle strength and endurance. Data from human space flight and ground-based studies are narrowing in on the required exercise paradigms but thus far still provide an incomplete answer to an effective approach for maintaining skeletal muscle function and aerobic fitness of all human space travelers. Finally, the relationship of this risk topic to various space flight operational scenarios is examined and discussed.

Eric Rivas↗

Determining the Importance of In-Flight Treadmill Running Capabilities for Maintaining Astronaut Health and Performance

BACKGROUND: Physical deconditioning induced via spaceflight is most effectively attenuated through in-flight exercise training. Throughout its evolution, NASA has implemented advancements to in-flight exercise countermeasures, culminating in the triad of devices currently used aboard the International Space Station (ISS): a treadmill (T2), cycle ergometer (CEVIS), and resistance exercise device (ARED). Despite high-quality exercise devices and prescriptions, many crewmembers experience reductions in both aerobic capacity (VO2peak pre-post mean change: -10%) and strength (knee isokinetic pre-post mean change: -15%). As NASA moves towards exploration missions, which will impose greater size, power, and time constraints on exercise systems in addition to physically demanding surface extravehicular activities (EVAs), providing robust capabilities to protect crew health and performance should be prioritized. OVERVIEW: Future missions to the Lunar and Martian surfaces will include EVAs requiring ambulation and greater physical exertion than those in Apollo missions. While the exercise device concepts planned for exploration missions include resistive and aerobic capabilities, they do not allow for ambulation. Specifically, the countermeasure planned for Artemis Lunar transit is a flywheel device, which provides both exercise modalities through a single resistive cable. While more robust than the flywheel, the devices planned for the Lunar orbital space station, and subsequent Mars habitats, will provide distinct aerobic and resistance modalities capable of achieving high intensities. However, these modalities do not include a treadmill. Recent research suggests that greater in-flight running intensity and volume attenuate decrements in aerobic capacity and strength; however, this has not been experimentally confirmed. The Exploration Exercise Treadmill Requirements study is currently underway, aiming to determine the effects of exercising without a treadmill on aerobic capacity, strength, bone density, and sensorimotor function during long-duration spaceflight. DISCUSSION: Providing running capabilities on future exploration missions may help to maintain astronaut physical ability, reduce injury, and promote health. Studies quantifying the effects of using exploration exercise devices are in progress, which will help provide critical recommendations on whether a treadmill is a necessary component of the in-flight training regime. This presentation will discuss the capabilities of exploration exercise devices and the potential implications of not having running capabilities during long-duration spaceflight.

Alyssa N Varanoske↗

Bone Metabolism on ISS Missions

Spaceflight-induced bone loss is associated with increased bone resorption (1, 2), and either unchanged or decreased rates of bone formation. Resistive exercise had been proposed as a countermeasure, and data from bed rest supported this concept (3). An interim resistive exercise device (iRED) was flown for early ISS crews. Unfortunately, the iRED provided no greater bone protection than on missions where only aerobic and muscular endurance exercises were available (4, 5). In 2008, the Advanced Resistive Exercise Device (ARED), a more robust device with much greater resistance capability, (6, 7) was launched to the ISS. Astronauts who had access to ARED, coupled with adequate energy intake and vitamin D status, returned from ISS missions with bone mineral densities virtually unchanged from preflight (7). Bone biochemical markers showed that while the resistive exercise and adequate energy consumption did not mitigate the increased bone resorption, bone formation was increased (7, 8). The typical drop in circulating parathyroid hormone did not occur in ARED crewmembers. In 2014, an updated look at the densitometry data was published. This study confirmed the initial findings with a much larger set of data. In 42 astronauts (33 male, 9 female), the bone mineral density response to flight was the same for men and women (9), and those with access to the ARED did not have the typical decrease in bone mineral density that was observed in early ISS crewmembers with access to the iRED (Figure 1) (7). Biochemical markers of bone formation and resorption responded similarly in men and women. These data are encouraging, and represent the first in-flight evidence in the history of human space flight that diet and exercise can maintain bone mineral density on long-duration missions. However, the maintenance of bone mineral density through bone remodeling, that is, increases in both resorption and formation, may yield a bone with strength characteristics different from those that existed before space flight. Studies to assess bone strength after flight are underway at NASA, to better understand the results of bone remodeling. Studies are also underway to evaluate optimized exercise protocols and nutritional countermeasures. Regardless, there is clear evidence of progress being made to protect bone during spaceflight.

Smith, S. M.↗

Noninvasive markers of bone metabolism in the rhesus monkey: normal effects of age and gender

Measurement of bone turnover in conditions such as osteoporosis has been limited by the need for invasive iliac bone biopsy to reliably determine parameters of bone metabolism. Recent advances in the area of serum and urinary markers of bone metabolism have raised the possibility for noninvasive measurements; however, little nonhuman primate data exist for these parameters. The purpose of this experiment was to define the normal range and variability of several of the newer noninvasive bone markers which are currently under investigation in humans. The primary intent was to determine age and gender variability, as well as provide some normative data for future experiments in nonhuman primates. Twenty-four rhesus macaques were divided into equal groups of male and female according to the following age groupings: 3 years, 5-10 years, 15-20 years, and > 25 years. Urine was collected three times daily for a four-day period and measured for several markers of bone turnoverm including pyridinoline (PYD), deoxypyrodinoline (DPD), hydroxyproline, and creatinine. Bone mineral density measurements of the lumbar spine were performed at the beginning and end of the study period. Serum was also obtained at the time of bone densitometry for measurement of osteocalcin levels by radioimmunoassay. There were no significant differences in bone mineral density, urine PYD, or urine DPD based on gender. Bone density was lowest in the youngest animals, peaked in the 15-20-year group, but again decreased in the oldest animals. The osteocalcin, PYD, and DPD levels followed an inversely related pattern to bone density. The most important result was the relative age insensitivity of the ratio of PYD:DPD in monkeys up to age 20 years. Since bone density changes take months or years to become measurable and iliac biopsies are invasive, the PYD/DPD marker ratio may have important implications for rapid noninvasive measurement of the effects of potential treatments for osteoporosis in the non-human primate model.

NASA Discipline Musculoskeletal↗

Battling Brittle Bones

The accuDEXA(R) Bone Mineral Density Assessment System, manufactured by Schick Technologies, Inc., utilizes "camera on a chip" sensor technology invented and developed by NASA's Jet Propulsion Laboratory. Schick's accuDEXA system offers several advantages over traditional osteoporosis tests, which assess bone density loss in the hip and spine, and require specialized personnel to conduct. With accuDEXA, physicians can test the entire body's bone density at a peripheral site, such as the finger, without applying gels or having patients remove garments. Results are achieved in 30 seconds and printed out in less than a minute, compared to the estimated exam time of 15 minutes for hip and spine density analyses. Schick has also applied the CMOS APS technology to a new software product that performs dental radiography using up to 90 percent less radiation exposure than conventional X-rays. Called Computed Dental Radiography(R), the new digital imaging product utilizes an electronic sensor in place of X-ray film to generate sharp and clear images that appear on a computer screen within 3 seconds, and can be enlarged and enhanced to identify problems.

Source record↗

Effect of High Impact or Non-impact Loading Activity on Bone Bending Stiffness and Mineral Density

Material properties of conical bone, including mineral density (BMD) and its geometry is closely related to its load-carrying capacity. These two primary components determine the strength of conical bone. High impact loading involving acceleration and deceleration movements used in gymnastics induce higher BMD of the affected bone compared to the non-impact acceleration and deceleration movements used in swimming. Study of these two groups of athletes on bone bending stiffness has not been reported. The purpose of this study was to compare differences in bone bending stiffness and BMD between competitive female synchronized swimmers and female gymnasts. Thirteen world class female synchronized swimmers (SYN) and 8 female gymnasts (GYM), mean age 21 +/- 2.9 yr. were recruited for this study. We used a mechanical response tissue analyzer (Gaitscan, NJ) to calculate EI, where E is Young's modulus of elasticity and I is the cross-sectional moment of inertia. EI was obtained from tissue response to a vibration probe placed directly on the skin of the mid-region of tibia and ulna. BMD of the heel and wrist were measured with a probe densitometer (PIXI, Lunor, WI). The SYN were taller than (p < 0.05) the GYM but weighed the same as the GYM. EI obtained from tibia and ulna of the SYN (291 +/- 159 and 41 +/- 19.4, respectively) were not significantly different from thc GYM (285 +/- 140 and 44 +/- 18.3, respectively). BMD of the heel and wrist in GYM were higher than in SYN (p < 0.001). High impact weight-bearing activities promote similar bone strength but greater BMD response than non-impact activities performed in a buoyant environment.

Liang, Michael T. C.↗

Bone Loss During Spaceflight: Available Models and Counter-Measures

There is ongoing concern for human health during spaceflights. Of particular interest is the uncoupling of bone remodeling and its resultant effect on calcium metabolism and bone loss. The calculated average loss of bone mineral density (BMD) is approximately 1-1.5% per month of spaceflight. The effect of decreased BMD on associated fractures in astronauts is not known. Currently on the International Space Station (ISS), bone loss is managed through dietary supplements and modifications and resistance exercise regimen. As the duration of space flights increases, a review of the current methods available for the prevention of bone loss is warranted. The goal of this project is to review and summarize recent studies that have focused on maintaining BMD during exposure to microgravity. Interventions were divided into physical (Table 1), nutritional (Table 2), or pharmacologic (Table 3) categories. Physical modalities included resistance exercise, low level vibration, and low intensity pulsed ultrasound. Nutritional interventions included altering protein, salt, and fat intake; and vitamin D supplementation. Pharmacologic interventions included the use of bisphosphonates and beta blockers. Studies reported outcomes based on bone density determined by DXA bone scan, micro-architecture of histology and microCT, and serum and urine markers of bone turnover. The ground analog models utilized to approximate osseous physiology in microgravity included human patients previously paralyzed or subjects confined to bedrest. Ground analog animal models include paralysis, immobilization and ovariectomies. As a result of the extensive research performed there is a multi-modality approach available for the management of BMD during spaceflight that includes resistance training, nutrition and dietary supplements. However, there is a paucity of literature describing a formalized tiered protocol to guide investigators through the progression from animal models to human patient ground analogs to experiments on the ISS. With regards to testing, further evaluation to determine the association between non-invasive tests and fracture during and after spaceflight needs to be performed.

Morris, Jonathan↗

Risk of Oxidative Damage to Bone from Increased Iron Stores During Space Flight

Iron stores are increased secondary to neocytolysis of red blood cells and a high dietary intake of iron during space flight. This raises concerns about the risk of excess iron causing oxidative damage in many tissues, including bone. Biomarkers of iron status, oxidative damage, and bone resorption during space flight were analyzed for 23 (16 M/7 F) International Space Station crewmembers as part of the Nutrition SMO project. Up to 5 in-flight blood samples and 24-h urine pools were collected over the course of the 4-6 month missions. Serum iron increased slightly during space flight and was decreased at landing (P < 0.0004). An increase in serum ferritin early in flight (217% in women and 68% in men, P < 0.0004), returning to preflight concentrations at landing, and a decrease in transferrin and transferrin receptors during flight indicated that a transient increase in iron stores occurred. No inflammatory response was observed during flight. The oxidative damage markers 8-hydroxy-2'-deoxyguanosine and prostaglandin F(sub 2(alpha)) were positively correlated (both P < 0.001) with serum ferritin. A greater area under the curve for ferritin during flight was correlated with greater changes in bone mineral density of several bone regions after flight (1). In a separate study (2), a ground-based investigation was conducted that examined the combined effects of radiation exposure and iron overload on sensitivity to radiation injury in several physiological systems in 12-wk male Sprague-Dawley rats. The rats were acclimated to an adequate iron diet (45 mg iron (ferric citrate)/kg diet) for 3 wk and then assigned to one of four groups: adequate iron (Fe) diet/no radiation, adequate Fe diet/ radiation, moderately high Fe diet (650 mg Fe (ferric citrate)/kg diet)/no radiation, and moderately high Fe diet/radiation. Animals remained on the assigned diet for 4 wk. Starting on day 14 of experimental diet treatment, animals were exposed to a fractionated dose (0.375 Gy) of Cs-137 every other day (3 Gy total dose). On day 29 (24 h after last radiation exposure), animals were euthanized. Oxidative stress markers in the liver, bone, eyes, and serum were assessed. There was evidence that the iron diet contributed to DNA damage as well as radiation exposure in the liver, eyes, and bone. Together, the results suggest that increased iron stores do constitute a risk factor for oxidative damage and bone resorption, during space flight and on Earth. Funded by the Human Health and Countermeasures Element of the NASA Human Research Program.

Zwart, S. R.↗

Men and Women in Space: Bone Loss and Kidney Stone Risk after Long-Duration Space Flight

Bone loss on Earth is more prevalent in women than men, leading to the assumption that women may be at greater risk from bone loss during flight. Until recently, the number of women having flown long-duration missions was too small to allow any type of statistical analysis. We report here data from 42 astronauts on long-duration missions to the International Space Station, 33 men and 9 women. Bone mineral density (dual-energy X-ray absorptiometry), bone biochemistry (from blood and urine samples), and renal stone risk factors were evaluated before and after flight. Data were analyzed in two groups, based on available resistance exercise equipment. The response of bone mineral density to flight was the same for men and women, and the typical decrease in bone mineral density (whole body and/or regional) after flight was not observed for either sex for those using an Advanced Resistive Exercise Device. Bone biochemistry, specifically markers of formation and resorption, generally responded similarly in male and female astronauts. The response of urinary supersaturation risk to space flight was not significantly different between men and women, although risks were typically increased after flight in both groups and risks were generally greater in men than in women before and after flight. Overall, the bone and renal stone responses of men and women to space flight were not different.

Smith, Scott M.↗

Modeling Space Radiation Induced Bone Changes in Rat Femurs through Finite Element Analysis

As the duration of manned missions outside of the Earth’s protective shielding increase, astronauts are at risk for exposure to space radiation. Various organ systems may be damaged due to exposure. This study investigates the bonestrength changes using finite element modeling of Long Evans rats (n=85) subjected to graded, head-only proton (0, 10, 25, and 100 cGy, 150 MeV/n) and 28silicon (0, 10, 25, and 50 cGy, 300 MeV/n) radiation. The strength of the femoral neck will be examined due its clinical relevance to hip fractures. It has been shown in previous studies that bone mineral density was not reduced at the site of fracture. These findings question whether measurements of bone mineral density may be used to assess risk of hip fracture. The mechanisms leading to the irregular relationship between bone density and strength are still uncertain within literature and investigated to greater extent in clinical applications. Finite element analysis within this study simulated physiological loading of the femoral neck. No significant changes in femoral neck strength were found across doses of proton or 28silicon head-only radiation. Future work includes performing mechanical testing of the bone samples. Moving from mouse to larger animal models may also provide the increased lifespan for assessing the long-term outcomes of radiation exposure.

Dale Johnson↗