At least 145 records · Page 8

Modeling a Water-Cooled Printed Circuit Heat Exchanger Condensing CO2 for use in SCO2 Cycle System Optimization Studies

This work describes a one-dimensional model of a water-cooled printed circuit heat exchanger (PCHE) condensing supercritical CO2. The model is developed for use in cycle optimization studies (e.g., minimizing levelized cost of electricity) as either the main heat rejection cooler and/or a compressor intercooler for recompression closed Brayton supercritical CO2 power cycles. Sensitivity and case studies are used to illustrate the impact of important model parameters, and this includes allowing for independent variation of zig-zag channel wave angles on the CO2 and water side. Results show that for a given CO2 design pressure (and thus saturation temperature), the PCHE design inlet water temperature has a significant impact on the PCHE size. Results also demonstrate that if wave angles are the same on the CO2 and water side, the water side pressure drop will have more influence on determining the optimum PCHE mass than the CO2 side pressure drop. Reducing the water side wave angle to near straight channel flow offers a more compact design for a similar water side pressure drop (and pump power requirement). Cases are also shown for further increasing the compactness and how the PCHE mass is affected along with water pump power.

Liese, Eric↗

Diffusion bonded compact heat exchanger in Inconel 740H for high temperature and high-pressure applications

It is desired to develop heat exchangers able to be operated at high temperatures (750˚C) and pressures (3636 psi) for use in advanced Brayton power cycle. Conventional materials have not had the high strength at temperature required for these applications previously, however a fairly new material Inconel 740H developed by Special Metals for the ultra-supercritical water fossil industry has shown good performance under these conditions. In further efforts to capitalize on these new high strength high temperature alloys CompRex has developed a diffusion bonding procedure capable of alloying compact high effectiveness heat exchangers that can perform under these high temperature and high-pressure conditions. Initial tests of the heat exchanger are being conducted at the University of Wisconsin using supercritical CO2 working fluid. The bonding process has been adjusted such that the strength of the bonded block has achieved over 90% yield and tensile strength of the 740H base material values. Grain size before and after bonding were measured to determine the extent of grain growth and grain diffusion across the interface. A discussion of the heat exchanger design, etching and initial tensile tests on sample bonds will be discussed.

14 SOLAR ENERGY↗

Alternatives to MARVEL Power Conversion – Comparison of Stirling Engine Thermal Efficiency and Design to other Power Conversion Cycles

The Microreactor Applications, Research, Validation, and Evaluation (MARVEL) Reactor is a small liquid-metal thermal reactor that will be built at the Idaho National Laboratory to demonstrate design and operating processes for microreactors, microgrid integration, and process heat applications. Power conversion in the MARVEL design is provided by Stirling engines, which have disadvantages in nuclear environments. Compared to Stirling engine performance, some alternative power cycles can increase power production when coupled to a liquid-metal thermal reactor In this paper, the thermal efficiency of MARVEL’s power production with Stirling engines is compared to the thermal efficiency of power production with MARVEL and alternative power cycles. Those cycles include a superheated Rankine cycle, open and closed Brayton cycles, and a supercritical carbon dioxide cycle. All cycles (except the Stirling engines) were modeled with an intermediate helium loop to meet MARVEL’s principal design criteria. All models are simple designs with conservative assumptions for consistent comparison. Detailed optimization will depend largely on reactor location and application, and the relative merit of each cycle is discussed for different environmental conditions. The study informs significant early decisions on power cycle design and economic

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Cost-Performance Analysis of a Sodium Heat Engine for Distributed Concentrating Solar Power

We present that a sodium thermal electrochemical converter (Na-TEC) generates electricity directly from heat through isothermal expansion of sodium ions across a beta"-alumina solid-electrolyte. This heat engine has been considered for use with conventional concentrating solar power (CSP) systems before. However, unlike previous single-stage devices, the improved design uses two stages with an interstage reheat, allowing more economical and efficient conversion up to 29% at a hot side temperature of 850 °C. Herein, a cost-performance analysis for this improved design assesses opportunities for distributed-CSP in the context of micro-combined heat and power systems. A high-level techno-economic analysis (TEA) is presented that explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per W e are feasible, which equate to LCOEs from 6.9 to 17.2 cents kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Process Heat for Chemical Industry

Process heating with nuclear energy can reduce greenhouse gas emissions by reducing combustion of fossil fuels in fired heaters as steam boilers. Light water reactors can replace the majority of steam duties used by industry; however, high temperature processes such as steam methane reforming require advanced high temperature reactors. Here, guidance on matching the scale of nuclear reactors with specific industries is provided. Principles of heat transport, temperature boosting, and substitution for hot combustion gases are also discussed in this section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal hydraulic characteristics of liquid sodium and supercritical CO 2 in a diffusion bonded heat exchanger

Compact heat exchangers are being examined for use in advanced, high-temperature nuclear or concentrated solar power plants to improve thermal efficiencies and reduce capital costs. At the time of this work, no experimental investigation of liquid sodium in the popular diffusion-bonded heat exchanger design had been performed. Herein this paper describes the thermal-hydraulic and overall operations performance observed during testing of a 316/L stainless steel “zig-zag” microchannel heat exchanger operating between a (0.5 kg/s) sodium loop and a (0.3 kg/s) recuperated supercritical CO 2 system with outlet conditions up to 550 °C at 16 MPa. Observed pressure drop is presented in the form of an effective friction factor correlation which aligns closely with recent experimental data. The thermal performance of this heat exchanger, measured by its overall conductance under various flow conditions, was decomposed to examine the independent convection behaviors of both the CO 2 and sodium streams. These results are presented in the form of Nusselt correlations fitted to the experimental data. The sodium heat transfer correlation aligns closely with the widely accepted Lubarsky-Kaufman correlation, while the CO 2 heat transfer correlation lies between previous correlations developed by computational and experimental methods. This was the first long-duration use of sodium in a microchannels (~1.8 mm hydraulic diameter) heat exchanger. The use of an oxide control system enabled trouble-free operation of the heat exchanger for over 150 h of high-temperature operation. This first-of-a-kind demonstration using liquid sodium and supercritical carbon dioxide shows great promise for further application of this technology in advanced nuclear or solar power plants.

42 ENGINEERING↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Quantifying the Influence of Defects on Selectivity of Electrodes Encapsulated by Nanoscopic Silicon Oxide Overlayers

Encapsulation of electrocatalysts and photocatalysts with semipermeable nanoscopic oxide overlayers that exhibit selective transport properties is an attractive approach to achieve high redox selectivity. However, defects within the overlayers-such as pinholes, cracks, or particle inclusions-may facilitate local high rates of parasitic reactions by creating pathways for facile transport of undesired reactants to exposed active sites. Scanning electrochemical microscopy (SECM) is an attractive method to determine the influence of defects on macroscopic performance metrics thanks to its ability to measure the relative rates of competing electrochemical reactions with high spatial resolution over the electrode. Here, we report the use of SECM to determine the influence of overlayer defects on the selectivity of silicon oxide (SiOx) encapsulated platinum thin-film electrocatalysts operated under conditions where two competing reactions-the hydrogen evolution and Fe(III) reduction reactions-can occur. After an SECM methodology is described to determine spatially resolved selectivity, representative selectivity maps are correlated with the location of defects that are characterized by optical, electron, and atomic force microscopies. This analysis reveals that certain types of defects in the oxide overlayer are responsible for ∼60-90% of the partial current density toward the undesired Fe(III) reduction reaction. By correcting for defect contributions to Fe(III) reduction rates, true Fe(III) permeability values for the SiOxoverlayers were determined to be over an order of magnitude lower than permeabilities determined from analyses that ignore the presence of defects. Lastly, different types of defects were studied revealing that defect morphology can have varying influence on both redox selectivity and calculated permeability. This work highlights the need for spatially resolved measurements to evaluate the performance of oxide-encapsulated catalysts and understand their performance limits.

25 ENERGY STORAGE↗

Manipulating polymer composition to create low-cost, high-fidelity sensors for indoor CO2 monitoring

Abstract Carbon dioxide (CO 2 ) has been linked to many deleterious health effects, and it has also been used as a proxy for building occupancy measurements. These applications have created a need for low-cost and low-power CO 2 sensors that can be seamlessly incorporated into existing buildings. We report a resonant mass sensor coated with a solution-processable polymer blend of poly(ethylene oxide) (PEO) and poly(ethyleneimine) (PEI) for the detection of CO 2 across multiple use conditions. Controlling the polymer blend composition and nanostructure enabled better transport of the analyte gas into the sensing layer, which allowed for significantly enhanced CO 2 sensing relative to the state of the art. Moreover, the hydrophilic nature of PEO resulted in water uptake, which provided for higher sensing sensitivity at elevated humidity conditions. Therefore, this key integration of materials and resonant sensor platform could be a potential solution in the future for CO 2 monitoring in smart infrastructure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dry cooler contribution to LCOE in a sCO 2 power cycle for CSP

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO 2 (sCO 2 ) based power cycles. Here, these cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 °C.

14 SOLAR ENERGY↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Experimental Validation of a High-Temperature Test Facility for Future Additive Manufactured Supercritical Carbon Dioxide Turbine Testing

For next-generation power plants to achieve high cycle efficiencies consistent with the Department of Energy's 65% efficiency target, turbomachinery capable of operating within high-temperature power cycles must be demonstrated. Pairing additively manufactured superalloy turbines with the supercritical carbon dioxide (sCO 2 ) power cycle could enable turbine inlet temperatures approaching 1300 °C while providing flexibility in turbine cooling strategies. Development of test facilities to characterize and validate such systems is crucial. In this study, a turbine test facility capable of achieving inlet conditions of 800 °C, 11 MPa, and 0.43 kg/s while accommodating complex auxiliary cooling flow requirements has been designed and constructed to support future testing of a Haynes 282 additively manufactured 30 kW turbine-generator system with advanced cooling channels. This facility enables characterization of aerodynamic performance, leakage, and windage losses. Details of the facility's construction and operation are presented, along with experimental validation tests using an orifice as an expansion device in place of the turbine. These tests confirm that the facility can reach the required conditions, distinguish regions of achievable steady and pseudo-steady conditions, and identify the heater power required for each point in the upcoming turbine campaign. The campaign confirmed that ISO 5167-2 can reliably predict orifice mass flow rates in extreme supercritical carbon dioxide conditions with deviations of 0.5–7.5%.

42 ENGINEERING↗

Reduced LCoE CSP Through Utilizing Process Gas Lubricated Bearings in Oil-Free Drivetrains

The GE Research team proposed to advance the TRL level of process lubricated gas bearings from TRL3 based on the DE-EE0007109 program to TRL5 addressing a critical risk item that radial gas bearings can provide satisfactory rotordynamic performance in supporting a representative rotor for sCO2 Power Cycles. The ability to apply process lubricated gas bearings can provide cost savings with reduction of the associated lube oil systems and an efficiency benefit worth 2% efficiency for the turbomachinery configuration first presented in DE-EE005804. The process lubricated gas bearings are enablers for advanced hermetically sealed configurations that have the potential for significant advancement in sCO2 Power Cycles for CSP applications including the 2% efficiency increase referred to above in addition to OPEX savings with no need to refill the CO2 valued at 60k USD/yr and cost reductions of 50 USD/kWe all leading to a potential 0.95¢/kWh reduction positively impacting CSP goals.

14 SOLAR ENERGY↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

Characterization of Inlet Guide Vane Performance for Discharge Compressor Operation near the Dome of an sCO 2 Pumped Heat Energy Storage

Southwest Research Institute® (SwRI®) developed and tested a Variable Inlet Guide Vane (IGV herein) assembly on an integrally-geared sCO 2 compressor (IGC) to demonstrate compressor operation at both the compressor design point and near the dome and to define the operating limits of the compressor by monitoring for two-phase flow, flow turbulence from the IGVs, and compressor choke and surge as the CO 2 inlet temperature is varied. Performance testing was conducted on an existing integrally-geared, two-stage main compressor designed for near-critical-point operation with CO 2 . This testing campaign validated the IGV design and operation, as well as improved the understanding and confidence in operating compressors and predicting performance characteristics near the critical point where fluid properties change rapidly with temperature. In addition to improving the robust operating limits of an sCO 2 compressor, the development of an IGV for the IGC system improved off-design compressor efficiency by 12%.

25 ENERGY STORAGE↗

Novel Modular Heat Engines with sCO 2 Bottoming Cycle Utilizing Advanced Oil-Free Turbomachinery

This report presents the thermal, mechanical, and electric machine design of a 27krpm rotating test rig aimed at reducing technical risks with hermetic oil-free super-critical carbon dioxide (sCO 2 ) turbomachinery. The test rig rotor system is based on a conceptual turbomachine design discussed that evaluates a sCO 2 waste heat recovery (WHR) unit for land-based gas turbines at natural gas (NG) compressor stations. The key novelty of the hermetic sCO 2 turbomachine concept is the utilization of additively manufactured CO 2 gas bearings and a CO 2 -immersed direct-drive permanent magnet (PM) electric machine. The previous effort on conceptual design identified 3 main technical risks, which included thrust bearing load capacity, rotordynamics, and thermal performance of the system. Therefore, key requirements of the test vehicle include the ability to test the rotor system in a 400psi (27.6 bar) hermetic CO 2 operating environment, apply up to 1,500 lbs (6.7 kN) of rotor thrust loads, capability to assess rotordynamics with radial gas bearings, inclusion of instrumentation to assess thrust bearing load capability, and flexibility for varying secondary cooling flows to confirm thermal model predictions. Design topics such as rotordynamics, bearing design, and electric machine design are addressed, while highlighting critical elements. In addition, additive build trials for Inconel 718 radial and thrust bearings were performed to prove the manufacturability of the bearing design concepts. The results of the design efforts yield a test rig concept with ability to operate at 27,000 rpm, apply thrust loads to 1,500 lbs, deliver CO 2 up to 800psi, and modulate cooling flows.

03 NATURAL GAS↗

Development of a High-Efficiency Hybrid Dry Cooler System for sCO 2 Power Cycles in CSP Applications

This project addressed a major gap in supercritical CO 2 (sCO 2 ) power cycle research by focusing on the pre-cooler, a component that had received little attention despite its significant impact on cycle efficiency and plant economics. The team developed a compact dry cooler using brazed/diffusion-bonded microchannel passages paired with formed air-side fins, advancing the technology from TRL-2 toward commercial readiness. Compared to conventional fin-tube coolers, the design cuts installation footprint by roughly half for 10+ MWth systems while achieving better heat transfer and lower approach temperatures, translating into a projected LCOE reduction from 6.04 ¢/kWh to between 5.85 and 5.94 ¢/kWh. While fabrication of an aluminum MW-scale prototype revealed brazing and sealing challenges at larger scales, lessons learned informed a subsequent 1 MWth unit that was successfully built and delivered for integration into Sandia's Gen3 Particle Pilot Plant, advancing the technology to TRL-7 with a path toward TRL-8 pending successful testing.