Search NASA⌕ Search

SEARCH · Search NASA

Results for “CARDIAC SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Echocardiographic assessment of cardiac disease

The physical principles and current applications of echocardiography in assessment of heart diseases are reviewed. Technical considerations and unresolved points relative to the use of echocardiography in various disease states are stressed. The discussion covers normal mitral valve motion, mitral stenosis, aortic regurgitation, atrial masses, mitral valve prolapse, and idiopathic hypertrophic subaortic stenosis. Other topics concern tricuspic valve abnormalities, aortic valve disease, pulmonic valve, pericardial effusion, intraventricular septal motion, and left ventricular function. The application of echocardiography to congenital heart disease diagnosis is discussed along with promising ultrasonic imaging systems. The utility of echocardiography in quantitative evaluation of cardiac disease is demonstrated.

Popp, R. L.↗

AngioVac Aspiration for Paradoxical Emboli Protection through a Fenestrated Fontan During Central Venous Thrombus Manipulation

This case reports describes a 39-year-old female with a history of surgically repaired hypoplastic left heart syndrome who presented with a left peripherally inserted central catheter (PICC) with associated large volume subclavian and brachiocephalic vein thrombus. Due to the presence of a right-to-left shunt via a fenestrated Fontan, there was clinical concern for a paradoxical embolism during removal of the PICC. The AngioVac aspiration system was successfully utilized to aspirate thromboemboli from the level of the proximal Glenn shunt during manipulation and removal of the PICC. This is the first reported case to demonstrate the safe and effective use of the AngioVac aspiration system for protection of paradoxical emboli through a cardiac right-to-left shunt during a procedure at high risk for thromboembolism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Programmable Pacemaker

Released in 1995, the Trilogy cardiac pacemaker is the fourth generation of a unit developed in the 1970s by NASA, Johns Hopkins Applied Physics Laboratory and St. Jude Medical's Cardiac Rhythm Management Division (formerly known as Pacesetter Systems, Inc.). The new system incorporates the company's PDx diagnostic and programming software and a powerful microprocessor that allows more functions to be fully automatic and gives more detailed information on the patient's health and the performance of the pacing systems. The pacemaker incorporates bidirectional telemetry used for space communications for noninvasive communication with the implanted pacemaker, smaller implantable pulse generators from space microminiaturization, and longer-life batteries from technology for spacecraft electrical power systems.

Source record↗

Advanced Pacemaker

Synchrony, developed by St. Jude Medical's Cardiac Rhythm Management Division (formerly known as Pacesetter Systems, Inc.) is an advanced state-of-the-art implantable pacemaker that closely matches the natural rhythm of the heart. The companion element of the Synchrony Pacemaker System is the Programmer Analyzer APS-II which allows a doctor to reprogram and fine tune the pacemaker to each user's special requirements without surgery. The two-way communications capability that allows the physician to instruct and query the pacemaker is accomplished by bidirectional telemetry. APS-II features 28 pacing functions and thousands of programming combinations to accommodate diverse lifestyles. Microprocessor unit also records and stores pertinent patient data up to a year.

Source record↗

Programmable Pacemaker

St. Jude Medical's Cardiac Rhythm Management Division, formerly known as Pacesetter Systems, Inc., incorporated Apollo technology into the development of the programmable pacemaker system. This consists of the implantable pacemaker together with a physician's console containing the programmer and a data printer. Physician can communicate with patient's pacemaker by means of wireless telemetry signals transmitted through the communicating head held over the patient's chest. Where earlier pacemakers deliver a fixed type of stimulus once implanted, Programalith enables surgery free "fine tuning" of device to best suit the patient's changing needs.

Source record↗

Gender differences in autonomic cardiovascular regulation: spectral, hormonal, and hemodynamic indexes

The autonomic nervous system drives variability in heart rate, vascular tone, cardiac ejection, and arterial pressure, but gender differences in autonomic regulation of the latter three parameters are not well documented. In addition to mean values, we used spectral analysis to calculate variability in arterial pressure, heart rate (R-R interval, RRI), stroke volume, and total peripheral resistance (TPR) and measured circulating levels of catecholamines and pancreatic polypeptide in two groups of 25 +/- 1.2-yr-old, healthy men and healthy follicular-phase women (40 total subjects, 10 men and 10 women per group). Group 1 subjects were studied supine, before and after beta- and muscarinic autonomic blockades, administered singly and together on separate days of study. Group 2 subjects were studied supine and drug free with the additional measurement of skin perfusion. In the unblocked state, we found that circulating levels of epinephrine and total spectral power of stroke volume, TPR, and skin perfusion ranged from two to six times greater in men than in women. The difference (men > women) in spectral power of TPR was maintained after beta- and muscarinic blockades, suggesting that the greater oscillations of vascular resistance in men may be alpha-adrenergically mediated. Men exhibited muscarinic buffering of mean TPR whereas women exhibited beta-adrenergic buffering of mean TPR as well as TPR and heart rate oscillations. Women had a greater distribution of RRI power in the breathing frequency range and a less negative slope of ln RRI power vs. ln frequency, both indicators that parasympathetic stimuli were the dominant influence on women's heart rate variability. The results of our study suggest a predominance of sympathetic vascular regulation in men compared with a dominant parasympathetic influence on heart rate regulation in women.

Non-NASA Center↗

Low level CO2 effects on pulmonary function in humans

The purpose of the study was to determine whether chamber exposure to low levels of CO2 results in functional alterations in gas mixing and closing volume in humans. Four healthy volunteer subjects were exposed to 0.7% CO2 and to 1.2% CO2. Spirometry, lung volumes, single breath nitrogen washout, diffusing capacity for carbon monoxide (DLCO) by two methods, and cardiac output were measured in triplicate. Values were obtained over two non-consecutive days during the training period (control) and on days 2 or 3, 4, 6, 10, 13, and 23 of exposure to each CO2 level. Measurements were made during the same time of day. There was one day of testing after exposure, while still in the chamber but off carbon dioxide. The order of testing, up until measurements of DLCO and cardiac output, were randomized to avoid presentation effects. The consistent findings were a reduction in diffusing capacity for carbon monoxide and a fall in cardiac output, occurring to a similar degree with both exposures. For the group as a whole, there was no indication of major effects on spirometry, lung volumes, gas mixing or dead space. We conclude that small changes may occur in the function of distal gas exchanging units; however, these effects were not associated with any adverse health effects. The likelihood of pathophysiologic changes in lung function or structure with 0.7 or 1.2% CO2 exposure for this period of time, is therefore, low.

NASA Discipline Cardiopulmonary↗

Augmented baroreflex heart rate gain after moderate-intensity, dynamic exercise

The occurrence of a sustained vasodilation and hypotension after acute, dynamic exercise suggests that exercise may alter arterial baroreflex mechanisms. Therefore, we assessed systemic hemodynamics, baroreflex regulation of heart rate, and cardiac vagal tone after 60 min of cycling at 60% peak oxygen consumption in 12 healthy, untrained men and women (ages 21-28 yr). We derived sigmoidal carotid-cardiac baroreflex relations by measurement of R-R interval changes induced by ramped, stepwise, R-wave-triggered changes in external neck pressure from 40 to -65 mmHg. We estimated tonic cardiac vagal control with power spectral analysis of R-R interval variability in the respiratory frequency band (0.2-0.3 Hz) during frequency- and tidal volume-controlled breathing. Both mean arterial pressure and total peripheral resistance were reduced postexercise [pressure: from 86 +/- 2 (mean +/- SE) to 81 +/- 2 mmHg; resistance: from 23 +/- 2 to 16 +/- 1 units; both P < 0.05]. Cardiac output was increased postexercise (from 3.9 +/- 0.3 to 5.5 +/- 0.5 l/min, P < 0.05). Both slope and range of the carotid-cardiac baroreflex relation were increased postexercise (slope: from 4.7 +/- 0.7 to 6.1 +/- 0.9 ms/mmHg; range: from 186 +/- 23 to 238 +/- 30 ms, P < 0.05). Respiratory R-R interval variability (cardiac vagal tone) was not changed at any time after exercise, whereas heart rate and plasma norepinephrine levels were elevated. Thus moderate-intensity, dynamic exercise increases heart rate and cardiac output, reduces peripheral vascular resistance, and augments baroreflex responsiveness. Our data suggest that augmented baroreflex heart rate gain restrains rather than contributes to postexercise hypotension, which appears to be mediated predominately by vasodilation.

NASA Discipline Cardiopulmonary↗

Citizen Science Approach for Searching and Curating Literature of the Effects of Spaceflight on Cardiovascular Outcomes in Rodents and Humans

The spaceflight environment causes significant changes to the structure and function of the cardiovascular system, including fluid redistribution, alterations in blood pressure, and changes in cardiac output. The goal of this project is to quantitatively summarize the data on the effects of actual or simulated microgravity and radiation exposure resulting from spaceflight on the cardiovascular system. As the first step, a group of investigators approached through a collaboration of the Ames Life Science Data Archive (ALSDA) Analysis Working Group developed a list of relevant cardiovascular search terms. Based on these, medical librarians generated and executed the search strategy in Medline, CINAHL, Embase and NASA repositories. In parallel, we recruited students and young professionals from various space industry-affiliated organizations, resulting in ~100 individuals joining. With this program we aimed to reach students and young people underrepresented in STEM, including first-generation, female, minorities, disadvantaged backgrounds, fostered individuals, etc. These individuals completed a virtual training course on the nature and methodologies of the project. Following this, the participants were structured into teams with more senior/experienced individuals designated as team leaders. Currently, the teams are screening approximately 15,000 studies using the systematic review tool, Covidence. Teams will be extracting and curating data for meta-analysis of the cardiovascular spaceflight literature, but also extracting, submitting, and curating appropriate datasets into the new ALSDA submission portal and repository. This effort will result in collaborative publications based upon the literature meta-analyses, and a number of publicly accessible datasets for reuse, modeling, machine learning, and knowledge graph-type approaches. This approach reduces the length of time to complete title/abstract screening time from 1-2 years needed for this volume of studies, to 3-4 months, while also providing a unique, open-access educational experience to space research and training in knowledge synthesis tools to interested individuals.

space biology↗

Cardiac-Activity Measures for Assessing Airport Ramp-Tower Controller's Workload

Heart rate (HR) and heart rate variability (HRV) potentially offer objective, continuous, and non-intrusive measures of human-operators mental workload. Such measurement capability is attractive for workload assessment in complex laboratory simulations or safety-critical field testing. The present study compares mean HR and HRV data with self-reported subjective workload ratings collected during a high-fidelity human-in-the-loop simulation of airport ramp traffic control operations, which involve complex cognitive and coordination tasks. Mean HR was found to be weakly sensitive to the workload ratings, while HRV was not sensitive or even contradictory to the assumptions. Until more knowledge on stress response mechanisms of the autonomic nervous system is obtained, it is recommended that these cardiac-activity measures be used with other workload assessment tools, such as subjective measures.

Hayashi, Miwa↗

Cardiac-Activity Measures for Assessing Airport Ramp-Tower Controller's Workload

Heart rate (HR) and heart rate variability (HRV) potentially offer objective, continuous, and non-intrusive measures of human-operator's mental workload. Such measurement capability is attractive for workload assessment in complex laboratory simulations or safety-critical field testing. The present study compares mean HR and HRV data with self-reported subjective workload ratings collected during a high-fidelity human-in-the-loop simulation of airport ramp traffic control operations, which involve complex cognitive and coordination tasks. Mean HR was found to be weakly sensitive to the workload ratings, while HRV was not sensitive or even contradictory to the assumptions. Until more knowledge on stress response mechanisms of the autonomic nervous system is obtained, it is recommended that these cardiac-activity measures be used with other workload assessment tools, such as subjective measures.

Hayashi, Miwa↗

Alterations in Cardiovascular Regulation and Function During Long-Term Simulated Microgravity

The Cardiovascular Alterations Team is conducting studies of hemodynamic regulation and susceptibility to arrhythmias resulting from sixteen days of simulated microgravity exposure. In these studies very intensive measurements are made during a short duration of bed rest. In this collaborative effort are making many of the same measurements, however much less frequently, on subjects who are exposed to a much longer duration of simulated microgravity. Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In addition, numerous reports from the past 30 years suggest that the incidence of ventricular arrhythmias among astronauts is increased during space flight. However, the effects of space flight and the associated physiologic stresses on cardiac conduction processes are not known, and an increase in cardiac susceptibility to arrhythmias has never been quantified. In this project we are applying the most powerful technologies available to determine, in a ground-based study of long duration space flight, the mechanisms by which space flight affects cardiovascular function, and then on the basis of an understanding of these mechanisms to develop rational and specific countermeasures. To this end we are conducting a collaborative project with the Bone Demineralization/Calcium Metabolism Team of the National Space Biomedical Research Institute (NSBRI). The Bone Team is conducting bed rest studies in human subjects lasting 17 weeks, which provides a unique opportunity to study the effects of long duration microgravity exposure on the human cardiovascular system. We are applying a number of powerful new methods to these long term bed rest subjects, including cardiovascular system identification (CSI), microvolt level T wave alternans analysis, and cardiac magnetic resonance imaging to assess non-invasively the effects of simulated long duration space flight on the cardiovascular system.

Cohen, Richard J.↗

Model-based approach to investigate equipment-induced error in pressure-waveform derived hemodynamic measurements

Advanced hemodynamic monitoring systems have provided less invasive methods for estimating pressure-derived measurements such as pressure-derived cardiac output (CO) measurements. These devices apply algorithms to arterial pressure waveforms recorded via pressure recording components that transmit the pressure signal to a pressure monitor. While standards have been developed for pressure monitoring equipment, it is unclear how the equipment-induced error can affect secondary measurements from pressure waveforms. We propose an approach for modelling different components of a pressure monitoring system and use this model-based approach to investigate the effect of different pressure recording configurations on pressure-derived hemodynamic measurements. The proposed model-based approach is a three-step process. (1) Modelling the response of pressure recording components using bench tests; (2) verifying the identified models through nonparametric equivalence tests; and (3) assessing the effects of pressure recording components on pressure-derived measurements. To delineate the application of this approach, we performed a series of model-based analyses to quantify the combined effect of a wide range of tubing configurations with various damping ratios and natural frequencies and monitors with different bandwidths on pressure waveforms and CO measurements by six pulse contour algorithms. Model-based results show the error in pressure-derived CO measurements because of tubing configurations with different natural frequencies and damping ratios. Tubing configurations with low natural frequencies (<23 Hz) altered characteristics of pressure waveforms in a way that affected the CO measurement, some by as much as 20%. Our method can serve as a tool to quantify the performance of pressure recording systems with different dynamic properties. In conclusion, this approach can be applied to investigate the effects of physiologic signal recording configurations on various pressure-derived hemodynamic measurements.

42 ENGINEERING↗

Fibroblast growth factor 19 protects the heart from oxidative stress-induced diabetic cardiomyopathy via activation of AMPK/Nrf2/HO-1 pathway

Highlights: • FGF19 Improves Cardiac Dysfunction and Fibrosis in Diabetic Cardiomyopathy. • FGF19 Prevent Cardiac Oxidative Stress in the Diabetic Heart. • FGF 19 induces expression Nrf2/HO-1 signaling axis through activation of AMPK. Diabetes affects cardiac structure and function, where it leads to diabetic cardiomyopathy. Reactive oxygen species (ROS) produced by oxidative stress play an important role in the development of diabetic cardiomyopathy. Fibroblast growth factor (FGF) 19, an enterokine, is synthesized and released into the ileum. In the present study, we revealed that FGF19 induced an antioxidant response through stimulating the expression of nuclear erythroid factor 2 (NE-F2)-related factor 2 (Nrf2) and as well as reducing ROS production through the AMPK signaling pathway. Additionally, AMPK inhibition by the AMPK-specific inhibitor compound C decreased Nrf2 and heme oxygenase-1 (HO-1) protein expression. Taken together, these results suggested that FGF19, through the anti-oxidative defense system, attenuated the development of diabetic cardiomyopathy and restored cardiac function.

60 APPLIED LIFE SCIENCES↗

Modeling heart rate variability by stochastic feedback

We consider the question of how the cardiac rhythm spontaneously self-regulates and propose a new mechanism as a possible answer. We model the neuroautonomic regulation of the heart rate as a stochastic feedback system and find that the model successfully accounts for key characteristics of cardiac variability, including the 1/f power spectrum, the functional form and scaling of the distribution of variations of the interbeat intervals, and the correlations in the Fourier phases which indicate nonlinear dynamics.

Non-NASA Center↗

A simplified HTc rf SQUID to analyze the human cardiac magnetic field

We have developed a four-channel high temperature radio-frequency superconducting quantum interference device (HT{sub c} rf SQUID) in a simple magnetically shielded room (MSR) that can be used to analyze the cardiac magnetic field. It is more robust and compact than existing systems. To achieve the high-quality magnetocardiographic signal, we explored new adaptive software gradiometry technology constructed by the first-order axial gradiometer with a baseline of 80mm, which can adjust its performance timely with the surrounding conditions. The magnetic field sensitivity of each channel was less than 100fT/√Hz in the white noise region. Especially, in the analysis of MCG signal data, we proposed the total transient mapping (TTM) technique to visualize current density map (CDM), then we focused to observe the time-varying behavior of excitation propagation and estimated the underlying currents at T wave. According to the clear 3D imaging, isomagnetic field and CDM, the position and distribution of a current source in the heart can be visualized. It is believed that our four-channel HT{sub c} rf SQUID magnetometer based on biomagnetic system is available to detect MCG signals with sufficient signal-to-noise (SNR) ratio. In addition, the CDM showed the macroscopic current activation pattern, in a way, it has established strong underpinnings for researching the cardiac microscopic movement mechanism and opening the way for its use in clinical diagnosis.

36 MATERIALS SCIENCE↗

Long-term Cardiac Mortality After Hypofractionated Radiation Therapy in Breast Cancer

Purpose: To explore very-long-term mortality from ischemic heart disease (IHD) after locoregional radiation therapy of breast cancer (BC) in relation to degree of hypofractionation and other treatment variables. Methods and Materials: Two hypofractionated regimens used for locoregional radiation therapy for BC from 1975 to 1991 were considered. Patients received 4.3 Gy × 2/week (10 fractions; target dose 43 Gy; n=1107) or 2.5 Gy × 5/week (20 fractions; target dose 50 Gy; n=459). To estimate cardiac doses, radiation fields were reconstructed in a planning system. Time to death from IHD was the endpoint, comparing the groups with each other and with age-matched, cancer-free control individuals, modeled with the Cox proportional hazards model. Results: Patients given 4.3 Gy × 10 had an increased risk of dying of IHD compared with both the 2.5 Gy group (hazard ratio [HR] = 2.37; 95% confidence interval [CI]: 1.06-5.32; P=.036) and the control group (HR = 1.59; 95% CI: 1.13-2.23; P=.008). Photon beams for parasternal fields gave an increased risk of dying of IHD compared with electron beams (HR = 2.56; 95% CI: 1.12-5.84; P=.025). Multivariate analysis gave an increased risk for the 4.3-Gy versus 2.5-Gy regimen with borderline significance (HR = 2.90; 95% CI: 0.97-8.79; P=.057) but not for parasternal irradiation. Conclusions: The degree of hypofractionation and parasternal photon beams contributed to increased cardiac mortality in this patient cohort. Differences emerged after 12 to 15 years, indicating the need of more studies with observation time of 2 decades.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalities include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.

60 APPLIED LIFE SCIENCES↗