Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

CCD Photometry of bright stars using objective wire mesh

Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag per two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.

79 ASTRONOMY AND ASTROPHYSICS↗

CCD photometric study and period investigation of V508 Oph

In this paper, new CCD photometric observations of V508 Oph obtained in 2009 and 2010 at the Xinglong Observatory are presented. From the new observations, six new times of minimum light were derived. The light curves were analyzed by using the 2003 version of the Wilson–Devinney program. It is found that the asymmetric light curves can be modeled by a hot spot on the secondary component. The degree of overcontact is 15.4%, implying that the system is a shallow-contact binary. Combining the new times of minimum light with the photoelectric and CCD data compiled from the database, we investigate its orbital period. The results show that the orbital period may be undergoing multiple changes: a long-term decrease at a rate of dP/dt=−(1.502±0.063)×10{sup −7} days year{sup −1}, and a small periodic variation with a period of 24.27(±0.34) years. Since V508 Oph is an overcontact system and both components are late-type stars, we discuss the possible connection between the mass transfer, magnetic activity, the third body, and the orbital period changes.

79 ASTRONOMY AND ASTROPHYSICS↗

CCD photometric study and period investigation of AH Tauri

In this paper, we present new CCD photometric observations of AH Tauri in the R band observed in 2006 at the Yunnan Observatory. Two new times of light minima were derived from these observations. We modeled the light curves using the 2003 version of the Wilson–Devinney program. The results show that the variations of the light curves can be expained by a cool spot on the primary star. The fill-out factor is about 6.6%, indicating that AH Tauri is a shallow-contact system. The mass ratio was determined to be about 0.505. In addition, the orbital period variations of AH Tauri were investigated based on all of the photoelectric and CCD light minimum times, including our two new data. It was found that the orbital period exhibits a possible periodic variation with a period of P{sub mod}=54.62 (±0.20) years and a secular period decrease of dP/dt=−(1.823±0.215)×10{sup −7} days yr{sup −1}. Since AH Tauri is an overcontact solar-like system, we discuss three mechanisms of the mass transfer, the light-time effect of the third body, and magnetic activity responsible for the orbital period changes.

79 ASTRONOMY AND ASTROPHYSICS↗

PROCESSING METHOD EFFECT ON SUN DIAMETER MEASUREMENT WITH CCD SOLAR ASTROLABE

Photometric Sun diameter measurement is based on the calculation of the inflection point of the solar limb. In ground measurement, this point is located at a position on the solar limb where the signal-to-noise ratio is very high, which necessitates the appropriate filtering techniques to eliminate the noise while preserving its position. In this paper, we compare the filtering method currently in use to process the CCD solar astrolabe data, the FFTD method widely used, with a different method that we propose. Using the acquired data from the CCD astrolabe at Calern, France during 1997, we can obtain a mean difference of 130 mas in the measured radii.

79 ASTRONOMY AND ASTROPHYSICS↗

A METHOD TO SEARCH FOR BULK MOTIONS IN THE ICM WITH CHANDRA CCD SPECTRA: APPLICATION TO THE BULLET CLUSTER

We propose a strategy to search for bulk motions in the intracluster medium (ICM) of merging clusters based on Chandra CCD data. Our goal is to derive robust measurements of the average redshift of projected ICM regions obtained from the centroid of the K{sub α} line emission. We thoroughly explore the effect of the unknown temperature structure along the line of sight to accurately evaluate the systematic uncertainties on the ICM redshift. We apply our method to the “Bullet cluster” (1E 0657-56). We directly identify 23 independent regions on the basis of the surface brightness contours, and measure the redshift of the ICM averaged along the line of sight in each. We find that the redshift distribution across these regions is marginally inconsistent with the null hypothesis of a constant redshift or no bulk motion in the ICM, at a confidence level of about 2σ. We tentatively identify the regions most likely affected by bulk motions and find a maximum velocity gradient of about (46 ± 13) km s{sup −1} kpc{sup −1} along the line of sight on a scale of ∼260 kpc along the path of the “bullet.” We interpret this as the possible signature of a significant mass of ICM pushed away along a direction perpendicular to the merging. This preliminary result is promising for a systematic search for bulk motions in bright, moderate-redshift clusters based on spatially resolved spectral analysis of Chandra CCD data.

79 ASTRONOMY AND ASTROPHYSICS↗

A Binary Offset Effect in CCD Readout and Its Impact on Astronomical Data

We have discovered an anomalous behavior of CCD readout electronics that affects their use in many astronomical applications. An offset in the digitization of the CCD output voltage that depends on the binary encoding of one pixel is added to pixels that are read out one, two, and/or three pixels later. One result of this effect is the introduction of a differential offset in the background when comparing regions with and without flux from science targets. Conventional data reduction methods do not correct for this offset. We find this effect in 16 of 22 instruments investigated, covering a variety of telescopes and many different front-end electronics systems. The affected instruments include LRIS and DEIMOS on the Keck telescopes, WFC3 UVIS and STIS on HST, MegaCam on CFHT, SNIFS on the UH88 telescope, GMOS on the Gemini telescopes, HSC on Subaru, and FORS on VLT. The amplitude of the introduced offset is up to 4.5 ADU per pixel, and it is not directly proportional to the measured ADU level. We have developed a model that can be used to detect this "binary offset effect" in data, and correct for it. Understanding how data are affected and applying a correction for the effect is essential for precise astronomical measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of low-energy particle remnants in high-energy collisions at the LHC with a skipper-CCD detector

We deployed the Mobile Skipper Testing Apparatus ∼33 m away from the Compact Muon Solenoid collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider. In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb −1 and 1.54 nb −1 for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: ≤ 20⁢𝑒 − and > 20⁢𝑒 − . For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% confidence level constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

Cervantes-Vergara, Brenda A. [Fermi National Accel↗

Charge-trap analysis in a SENSEI skipper-CCD: Understanding low-energy backgrounds in rare-event searches

Skipper charge-coupled devices (CCDs) are ultralow-threshold detectors capable of detecting energy deposits in silicon at the electronvolt scale. Skipper CCDs are increasingly used in rare-event searches, including experiments such as SENSEI, DAMIC-M, Oscura, and CONNIE, where one of the major challenges is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we use the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly, but more work is needed to assess the impact of the traps that cannot be characterized.

Brusco, Agustin↗

Cooling the Dark Energy Camera CCD Array using a Closed-Loop, Two-Phase Liquid Nitrogen system

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO. This instrument is a 3 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k x 4k CCDs and 12 2k x 2k CCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. The DECam CCD array is inside the imager vessel. The focal plate is cooled using a closed loop liquid nitrogen system. As part of the development of the mechanical and cooling design, a full scale prototype imager vessel has been constructed and is now being used for Multi-CCD readout tests. The cryogenic cooling system and thermal controls are described along with cooling results from the prototype camera. The cooling system layout on the Blanco telescope in Chile is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRA-16: Development of a Radiation Monitoring Device Using a Low-Cost CCD Camera Following Radionuclide Therapy

Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Apple iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.

60 APPLIED LIFE SCIENCES↗

Technical Note: Range verification system using edge detection method for a scintillator and a CCD camera system

Purpose: Three-dimensional irradiation with a scanned carbon-ion beam has been performed from 2011 at the authors’ facility. The authors have developed the rotating-gantry equipped with the scanning irradiation system. The number of combinations of beam properties to measure for the commissioning is more than 7200, i.e., 201 energy steps, 3 intensities, and 12 gantry angles. To compress the commissioning time, quick and simple range verification system is required. In this work, the authors develop a quick range verification system using scintillator and charge-coupled device (CCD) camera and estimate the accuracy of the range verification. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. The optical spatial resolution of the system is 0.2 mm/pixel. The camera control system was connected and communicates with the measurement system that is part of the scanning system. The range was determined by image processing. Reference range for each energy beam was determined by a difference of Gaussian (DOG) method and the 80% of distal dose of the depth-dose distribution that were measured by a large parallel-plate ionization chamber. The authors compared a threshold method and a DOG method. Results: The authors found that the edge detection method (i.e., the DOG method) is best for the range detection. The accuracy of range detection using this system is within 0.2 mm, and the reproducibility of the same energy measurement is within 0.1 mm without setup error. Conclusions: The results of this study demonstrate that the authors’ range check system is capable of quick and easy range verification with sufficient accuracy.

60 APPLIED LIFE SCIENCES↗

SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

60 APPLIED LIFE SCIENCES↗

Gated-Viewing System with an Electronic Shutter on a CCD Image Sensor

The results of the development and experimental investigation of the gated-viewing method without the using an image intensifier as a fast shutter are presented. The device for implementing the method consists of an interline CCD image sensor with an input lens and 906 nm pulsed laser diode with an output lens that forms an illumination beam. The gated-viewing method is based on the original CCD control procedure, which allows observing multiple pulses without lowering the frame rate. Experimental studies have shown the method feasibility under conditions of smoke and fog.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial resolution of a hard x-ray CCD detector

The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20{mu}m pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95{mu}m (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to the three-color optical CCD-based pyrometer system

We put forward an improved three-color measurement scheme with a color CCD sensor using the combination of effective wavelengths and blackbody calibrations. The process of effective wavelengths realizes the separation of the emissivity function from the measurement integral equation. This improved method not only effectively avoids errors arising from the traditional process adopting the basic wavelengths, but also simplifies the complex integral calculations. For a blackbody or graybody, the measurement performance of the pyrometer was experimentally investigated from the point of the temperature sensitivity. The results show that narrowing the spectrum bandwidth with different bandpass spectral filters may improve the temperature sensitivities. The spectrum adjustment not only makes the linear emissivity more suitable in the narrower waveband, but also reduces the numerical uncertainty of the effective wavelengths. For nongray objects, the effects of the numerical uncertainty of the effective wavelengths to measurements were quantificationally evaluated at different measurement conditions (different temperatures, emissivities, and spectrums). The results indicate that the reference values of 584, 555, and 511nm or 607, 560, and 506nm of the effective wavelengths are reasonable for the present system with the modified spectral response using Filter 1 or Filter 2. The maximum calculation errors arising from the reference effective wavelengths are less than 1.6%. In this paper, the technical realization steps of the improved method are also described. The measurement experiments of a metal sample in hot environments were carried out to further verify the applicability of this improved CCD-based pyrometer. The results agreed well with the spectrometer-based results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface profile measurement in white-light scanning interferometry using a three-chip color CCD

White-light scanning interferometry (WLSI) is a useful technique to measure surface profile when a test object contains discontinuous structures or microstructures. A black and white CCD camera is usually utilized to capture interferograms, and a series of corresponding algorithms is used to achieve the profile measurement. However, the color information in the interferograms is lost. A novel profile measurement method that uses phase information in different color channels (red-green-blue) of an interferogram obtained using a three-chip color CCD in WLSI is proposed. The phase values are extracted by a windowed Fourier transform algorithm. Simulation and experimental results are presented to demonstrate the validity of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multi-channel cryogenic low-noise skipper-CCD readout ASIC

• Skipper CCDs provide exceptionally low noise useful for dark matter detection• MIDNA ASIC enables scaled cryogenic Skipper CCD readout• Noise performance proven to specification at room temperature with CCD• Liquid nitrogen measurements show functionality with more to come• Future development will integrate more sensitive signals and averaging capability

England, Troy↗

A Skipper-CCD Light Shield for X-Ray Detection in Space

We present advancements in the design of Skipper-CCD sensors for X-ray detection in environments with high optical backgrounds, such as those expected in space. These packages incorporate a custom-made aluminum shield on the CCD surface that blocks over 99% of visible light while preserving the efficiency for keV X-rays. These features allow us to perform precise X-ray measurements in environments challenged by visible light interference. Furthermore, we briefly discuss the potential implementation of this design concept in frame-transfer CCDs, opening opportunities for broader applications and advancements in imaging technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗