Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

On-Chip Single-Layer Integration of Diamond Spins with Microwave and Plasmonic Channels

On-chip scalable integration represents a major challenge for practical quantum devices. One particular challenge is to implement on-chip optical readout of spins in diamond. This readout requires simultaneous application of optical and microwave fields along with the efficient collection of fluorescence. These requirements are typically met using bulk optical components and dedicated microwave lines. Here, we experimentally demonstrate an on-chip integrated interface for diamond nitrogen vacancy (NV) spin-state preparation and readout, implemented in a planar single layer with only one patterning step. A nanodiamond with NV centers is positioned inside a v-groove waveguide milled in a thick gold film. The gold film carries the microwave control signal, while the v-groove acts as a fluorescence collector and, potentially, as an integrated pump filter. Hence, the device dimensions and fabrication complexity are substantially reduced. Our approach fosters further development of ultracompact nanoscale quantum sensors and quantum information processing devices on a monolithic platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chip-integrated metasurface full-Stokes polarimetric imaging sensor

Abstract Polarimetric imaging has a wide range of applications for uncovering features invisible to human eyes and conventional imaging sensors. Chip-integrated, fast, cost-effective, and accurate full-Stokes polarimetric imaging sensors are highly desirable in many applications, which, however, remain elusive due to fundamental material limitations. Here we present a chip-integrated Meta surface-based Full-Stokes Polar imetric Im aging sensor (MetaPolarIm) realized by integrating an ultrathin (~600 nm) metasurface polarization filter array (MPFA) onto a visible imaging sensor with CMOS compatible fabrication processes. The MPFA is featured with broadband dielectric-metal hybrid chiral metasurfaces and double-layer nanograting polarizers. This chip-integrated polarimetric imaging sensor enables single-shot full-Stokes imaging (speed limited by the CMOS imager) with the most compact form factor, records high measurement accuracy, dual-color operation (green and red) and a field of view up to 40 degrees. MetaPolarIm holds great promise to enable transformative applications in autonomous vision, industry inspection, space exploration, medical imaging and diagnosis.

47 OTHER INSTRUMENTATION↗

High-performance and scalable on-chip digital Fourier transform spectroscopy

Abstract On-chip spectrometers have the potential to offer dramatic size, weight, and power advantages over conventional benchtop instruments for many applications such as spectroscopic sensing, optical network performance monitoring, hyperspectral imaging, and radio-frequency spectrum analysis. Existing on-chip spectrometer designs, however, are limited in spectral channel count and signal-to-noise ratio. Here we demonstrate a transformative on-chip digital Fourier transform spectrometer that acquires high-resolution spectra via time-domain modulation of a reconfigurable Mach-Zehnder interferometer. The device, fabricated and packaged using industry-standard silicon photonics technology, claims the multiplex advantage to dramatically boost the signal-to-noise ratio and unprecedented scalability capable of addressing exponentially increasing numbers of spectral channels. We further explore and implement machine learning regularization techniques to spectrum reconstruction. Using an ‘elastic-D 1 ’ regularized regression method that we develop, we achieved significant noise suppression for both broad (>600 GHz) and narrow (<25 GHz) spectral features, as well as spectral resolution enhancement beyond the classical Rayleigh criterion.

47 OTHER INSTRUMENTATION↗

A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface

Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, we analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-chip beamsplitter operation on single photons from quasi-resonantly excited quantum dots embedded in GaAs rib waveguides

We present an on-chip beamsplitter operating on a single-photon level by means of a quasi-resonantly driven InGaAs/GaAs quantum dot. The single photons are guided by rib waveguides and split into two arms by an evanescent field coupler. Although the waveguides themselves support the fundamental TE and TM modes, the measured degree of polarization (∼90%) reveals the main excitation and propagation of the TE mode. We observe the preserved single-photon nature of a quasi-resonantly excited quantum dot by performing a cross-correlation measurement on the two output arms of the beamsplitter. Additionally, the same quantum dot is investigated under resonant excitation, where the same splitting ratio is observed. An autocorrelation measurement with an off-chip beamsplitter on a single output arm reveal the single-photon nature after evanescent coupling inside the on-chip splitter. Due to their robustness, adjustable splitting ratio, and their easy implementation, rib waveguide beamsplitters with embedded quantum dots provide a promising step towards fully integrated quantum circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On-chip spectroscopy with thermally tuned high-Q photonic crystal cavities

Spectroscopic methods are a sensitive way to determine the chemical composition of potentially hazardous materials. Here, we demonstrate that thermally tuned high-Q photonic crystal cavities can be used as a compact high-resolution on-chip spectrometer. We have used such a chip-scale spectrometer to measure the absorption spectra of both acetylene and hydrogen cyanide in the 1550 nm spectral band and show that we can discriminate between the two chemical species even though the two materials have spectral features in the same spectral region. Our results pave the way for the development of chip-size chemical sensors that can detect toxic substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-chip photonic system using suspended p-n junction InGaN/GaN multiple quantum wells device and multiple waveguides

We propose, fabricate, and characterize the on-chip integration of suspended p-n junction InGaN/GaN multiple quantum wells (MQWs) device and multiple waveguides on the same GaN-on-silicon platform. The integrated devices are fabricated via a wafer-level process and exhibit selectable functionalities for diverse applications. As the suspended p-n junction InGaN/GaN MQWs device operates under a light emitting diode (LED) mode, part of the light emission is confined and guided by the suspended waveguides. The in-plane propagation along the suspended waveguides is measured by a micro-transmittance setup. The on-chip data transmission is demonstrated for the proof-of-concept photonic integration. As the suspended p-n junction InGaN/GaN MQWs device operates under photodiode mode, the light is illuminated on the suspended waveguides with the aid of the micro-transmittance setup and, thus, coupled into the suspended waveguides. The guided light is finally sensed by the photodiode, and the induced photocurrent trace shows a distinct on/off switching performance. These experimental results indicate that the on-chip photonic integration is promising for the development of sophisticated integrated photonic circuits in the visible wavelength region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray transparent microfluidic chips for high-throughput screening and optimization of in meso membrane protein crystallization

Elucidating and clarifying the function of membrane proteins ultimately requires atomic resolution structures as determined most commonly by X-ray crystallography. Many high impact membrane protein structures have resulted from advanced techniques such as in meso crystallization that present technical difficulties for the set-up and scale-out of high-throughput crystallization experiments. In prior work, we designed a novel, low-throughput X-ray transparent microfluidic device that automated the mixing of protein and lipid by diffusion for in meso crystallization trials. Here, in this work, we report X-ray transparent microfluidic devices for high-throughput crystallization screening and optimization that overcome the limitations of scale and demonstrate their application to the crystallization of several membrane proteins. Two complementary chips are presented: (1) a high-throughput screening chip to test 192 crystallization conditions in parallel using as little as 8 nl of membrane protein per well and (2) a crystallization optimization chip to rapidly optimize preliminary crystallization hits through fine-gradient re-screening. We screened three membrane proteins for new in meso crystallization conditions, identifying several preliminary hits that we tested for X-ray diffraction quality. Further, we identified and optimized the crystallization condition for a photosynthetic reaction center mutant and solved its structure to a resolution of 3.5 Å.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial assessment of second generation of large-area picosecond photodetectors with multi-channel systems-on-a-chip readout

Here, we first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of the motivations is future large neutrino detectors that could, in principle, differentiate between Cherenkov and scintillation light if using novel water-based scintillators. In this paper, we present the first measurements utilizing the second generation of Large Area Picosecond Photodetectors (LAPPDs) in conjunction with commercial system-on-a-chip readouts from Nalu Scientific—in particular, the High Density System on Chip (HDSoC) and Advanced ASoC Rapid Digitizer, Variable Adaptive Readout Chip (AARDVARC) platforms. These state-of-the-art full-waveform digitizers feature sampling rates on the order of 1 and 10 samples per nanosecond, respectively. Using a picosecond laser, we measured the timing jitter between a pair of LAPPD channels, demonstrating the potential of this setup for precise timing applications.

Li, V. A. [Lawrence Livermore National Laboratory ↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SALSA: a new versatile readout chip for MPGD detectors

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other usages of MPGD detectors like TPC or photon detectors. It integrates a frontend block and an ADC for each of the 64 channels, associated to a configurable DSP processor meant to correct data and reduce the raw data flux to limit the output bandwidth. It will be compatible with the continuous readout foreseen for the EPIC DAQ, but will also work in a triggered environment. Several prototypes are already produced in order to qualify the different blocks of the chip, in particular the frontend, the ADC and the clock generation. The next 32-channel prototype is currently under development and is planed to be produced in 2025. In conclusion, the final prototype will be produced and tested from 2026 for a production of the SALSA chip at the horizon of 2027.

Data processing↗

Low power on-chip data transmission for wafer-scale monolithic active pixel sensors

Here, this paper details the implementation of the digital pulse shaping subsystem within the Backbone Transmission Line Encoding (BTLE) driver, a low-power, long-distance on-chip data transmission solution designed in a 65 nm CMOS process. Digital pulse shaping is critical for minimizing inter-symbol interference (ISI) caused by bandwidth limitations of on-chip interconnects, especially in wafer-scale monolithic active pixel sensors (MAPS). A duobinary encoder coupled with a parallelized polyphase finite impulse response (FIR) filter is used for efficient shaping of the transmitted signal spectrum. This reconfigurable architecture achieves reliable 160 Mb/s data transfer over a 10 cm on-chip link, as validated by simulations demonstrating low power consumption (FoM 37.3 fJ/bit/mm of transmission line length) and effective ISI mitigation.

47 OTHER INSTRUMENTATION↗

On-Chip Laser-Power Delivery System for Dielectric Laser Accelerators

We propose an on-chip optical-power delivery system for dielectric laser accelerators based on a fractal “tree-network” dielectric waveguide geometry. Here, this system replaces experimentally demanding free-space manipulations of the driving laser beam with chip-integrated techniques based on precise nanofabrication, enabling access to orders-of-magnitude increases in the interaction length and total energy gain for these miniature accelerators. Based on computational modeling, in the relativistic regime, our laser delivery system is estimated to provide 21 keV of energy gain over an acceleration length of 192 μm with a single laser input, corresponding to a 108-MV/m acceleration gradient. The system may achieve 1 MeV of energy gain over a distance of less than 1 cm by sequentially illuminating 49 identical structures. These findings are verified by detailed numerical simulation and modeling of the subcomponents, and we provide a discussion of the main constraints, challenges, and relevant parameters with regard to on-chip laser coupling for dielectric laser accelerators.

43 PARTICLE ACCELERATORS↗

Analysis and Experimental Evaluation of Middle-Point Inductance's Effect on Switching Transients for Multiple-Chip Power Module Package

Middle-point inductance L middle can be introduced in multiple-chip power module package designs. In this paper, the effect of middle-point inductance on switching transients is analyzed first using a frequency-domain analysis. Then a dedicated multiple-chip power module is fabricated with the capability of varying L middle , and extensive switching tests are conducted to evaluate the middle-point inductance's impact. Experiment result shows that the active MOSFET's turn-on loss decreases at higher values of L middle , while its turn-off loss increases. Detailed analysis of this loss variation is presented. In addition to the switching loss variation, it is also observed that different peak voltage stresses are imposed on the active switch and antiparallel diode during the switching transients. Specifically, in the case of lower MOSFET's turn-off, the maximum voltage of the lower MOSFET increases as L middle goes up; however, the peak voltage of the antiparallel diode decreases significantly. Furthermore, the induced voltage spikes during upper MOSFET turn-on process is also evaluated, and an opposite trend is observed experimentally. Analysis of the voltage overshoot variation is discussed. Based on the experimental evaluation and analysis, a multiple-chip power module package design guideline is summarized considering the middle-point inductance's effect.

42 ENGINEERING↗

A Unidirectional Two-Compartment Neuron Circuit with On-chip STDP learning

Most neuromorphic chips implement the single-compartment point neuron model where synapse circuits connect directly to a leaky integrate and fire (LIF) soma circuit. However, when using a biologically plausible soma circuit (e.g., Hodgkin-Huxley neuron model), an interface circuitry, such as a current conveyor circuit, is needed to transmit synaptic current to the soma circuit. This is especially true for ultra-low power neuron circuits, where membrane capacitance is on the order of 20 fF. This need for an interface circuit arises because the parasitic capacitance and leakage current caused by fabrication mismatch and second-order effects of the output transistors in the synapse circuits can disturb the spiking dynamics of the soma circuit if connected without an interface. Using an interface circuit to isolate the soma’s membrane capacitor from synapses resolves this issue. We propose to use a unidirectional resistor (a transconductance circuit) to connect the synapse and soma circuits instead of conventional current conveyor circuits. Using a biologically plausible spike pattern detection model, we show that the on-chip spike-timing-dependent plasticity (STDP) learning performance of the proposed unidirectional two-compartment neuron circuit is similar to a single-compartment circuit (with a current conveyor as an interface) and additionally, it is more power-efficient and biologically plausible. The chip is fabricated in the Taiwan Semiconductor Manufacturing Company (TSMC) 250 nm technology node and comprises a single neuron circuit.

Gautam, Ashish [ORNL]↗

High power chip-scale laser

The lack of high-power integrated lasers has been limiting silicon photonics. Despite much progress in chip-scale laser integration, power output remains below levels required for key applications due to low energy efficiency at high pumping currents. Here we break this power limitation by coupling a broad-area multimode gain chip to a silicon-nitride ring resonator and single-mode filter. The resulting optical feedback causes the multimode-gain chip to concentrate its power into a single highly coherent mode. Our device produces more than 150 mW of power and 400 kHz linewidth. We achieve these metrics while maintaining a small footprint of 3 mm 2 .

Antman, Yair↗

A self-certifying FPGA based pixel readout chip test system for CMS ETL upgrade

A flexible self-certifying pixel readout test system for testing the Endcap Timing Read-Out Chip (ETROC) has been developed for the CMS MIP Timing Detector (MTD), part of the upgrade for the HL-LHC. The system includes an FPGA-based (Xilinx KC705) test system that can take data from an emulator or up to four ETROC boards in telescope mode. A python based DAQ system simplifies configuration, calibration, and testing of the chips. The system provides an efficient & reliable solution for testing ETROC (ETROC2 since April 2023 with 16x16 pixels, full-size, full functionality prototype) and can be extended to other readout chips with similar architecture (AIDA integration is currently being explored).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chip Formation in Constrained Cutting

Existing approaches to chip formation in free and constrained cutting are analyzed. A new approach to description of the chip formation zone in constrained cutting with a single conditional shear surface is proposed. An analytical description of the shape of that surface is presented in general form. As an illustration, the chip formation zone is analyzed for sharp and rounded cutting edges. The results apply to the mechanics of cutting by blades.

42 ENGINEERING↗