Search NASA⌕ Search

SEARCH · Search NASA

Results for “CIRCUIT BREAKER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Precursor Analysis Report: Industroyer2 and Wiper Malware Targeting Ukrainian Energy Provider 2022

The Industroyer2 and Wiper Malware Targeting Ukrainian Energy Provider 2022 Precursor Analysis Report leverages publicly available information about the Industroyer2 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. An adversary attempted to cause a blackout in Ukraine in April 2022 by using the Industroyer2 malware against a regional Ukrainian energy provider. The adversary targeted eight high-voltage electrical substations and utilized the malware in tandem with disk wipers for Windows, Linux, and Solaris operating systems in an attempt to make response and recovery efforts more difficult. The adversary reused a piece of the original Industroyer malware designed to open circuit breakers and de-energize target substations. The adversary gained initial access to the victim’s enterprise network through unknown means in February 2022 and was able to perform reconnaissance, pivot to the operations network, and reside in the system for at least 51 days. This gave the adversary a detailed understanding of the environment and allowed them to customize the Industroyer2 malware to the victim’s operations network. However, defenders detected and stopped the attack before the adversary could achieve their intended impact. Had the Industroyer2 attack been successful, it could have caused a blackout for more than two million people during the early stages of Russia’s invasion of Ukraine. Researchers and analysts identified 22 unique techniques (used in a sequence of 31 steps) utilized during the attack with a total of 297 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-three of the identified techniques used during the Industroyer2 cyber attack were precursors to the triggering event. Analysis identified 224 observables associated with these precursor techniques, 122 of which were assessed to have an increased likelihood of being perceived in the 51 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Two terminal current limiter

Two terminal device protects dc electronic circuits and experimental solid state devices, and replaces fuses and circuit breakers directly. The device consists of two transistors and two resistors and draws its necessary supply voltage from power source being protected. The limiter acts as a voltage regulator.

Doubt, L. S.↗

Mercury capillary interrupter Patent

Interrupter switching device utilizing electrodes and mercury filled capillary tubes in which current flow vaporizes mercury as circuit breaker

Heckler, C. H.↗

Current switch has built-in time delay: A concept

Switch concept provides simple means of achieving electromechanical time delay function. Unit consists of reed-type circuit breaker enclosed by copper tubing with electromagnetic coil wound around tubing and entire assembly mounted on insulating platform. Characteristics are affected only by geometry of system so device is expected to be very stable.

Jesch, C. D.↗

Apollo 14 mission: Inability to disconnect main bus A

During entry, the Apollo 14 spacecraft busses should have de-energized when the main bus-tie motor switches were switched to the off position. One motor switch did not transfer and main bus A remained energized until the battery bus-tie circuit breakers were opened after landing. Analysis revealed that residual catalyst caused the terminal pin seals to revert to a gummy state. Resulting reversion products then migrated to the motor commutator and caused brush degradation, increased and erratic commutator resistance, and reduced motor torque. The motor stalled when available motor torque was reduced below that required to drive through the maximum torque point of the switch.

Source record↗

Thermally responsive mechanical actuator

Device built for use in heat control, heat measurement, and mechanical actuation by heat include thermometers, thermostats, safety switches, circuit breakers, and mechanical actuators. Silicon rubber has highest coefficient of expansion of any known material and seems suitable for most of these devices.

Madey, J. M.↗

Logic controlled solid state switchgear

Logic controlled solid state circuit breakers and power transfer switches have been designed and built to demonstrate their use for 270 V dc power systems. This switchgear provides remote operation, automatic current level, and operates several orders of magnitude faster with much greater accuracy of response than conventional switchgear.

Buchanan, E.↗

Long life assurance study for manned spacecraft long life hardware. Volume 2: Long life assurance studies of EEE parts and packaging

Guidelines for the design, development, and fabrication of electronic components and circuits for use in spacecraft construction are presented. The subjects discussed involve quality control procedures and test methodology for the following subjects: (1) monolithic integrated circuits, (2) hybrid integrated circuits, (3) transistors, (4) diodes, (5) tantalum capacitors, (6) electromechanical relays, (7) switches and circuit breakers, and (8) electronic packaging.

Source record↗

Rigid format alter packets for the analysis of electromagnetic field problems

The computer program NASTRAN is used to solve electromagnetic field problems. The diffusion equation and the boundary conditions valid for problems of these kinds together with a replacing potential energy function are given. The extent to which an analogy with finite element displacement and temperature approaches holds is indicated. The outputting of complex quantities is made possible after adjustment of standard rigid format 1 input data blocks to module SDR2. The applications made involve the study of the proximity effect in a system of three parallel conductors and the analysis of the magnetic field in the vicinity of the points of contact in circuit breakers.

Spreeuw, E.↗

Protection coordination of the Kennedy Space Center electric distribution network

A computer technique is described for visualizing the coordination and protection of any existing system of devices and settings by plotting the tripping characteristics of the involved devices on a common basis. The program determines the optimum settings of a given set of protective devices and configuration in the sense of the best expected coordinated operation of these devices. Subroutines are given for simulating time versus current characteristics of the different relays, circuit breakers, and fuses in the system; coordination index computation; protection checks; plotting; and coordination optimation.

Source record↗

Improved switch-resistor packaging

Packaging approach makes resistors more accessible and easily identified with specific switches. Failures are repaired more quickly because of improved accessibility. Typical board includes one resistor that acts as circuit breaker, and others are positioned so that their values can be easily measured when switch is operated. Approach saves weight by using less wire and saves valuable panel space.

Redmerski, R. E.↗

Thunderstorm hazards flight research - Program overview

The NASA thunderstorm hazards research program, designed to study the effects of lightning strikes on the design and operation of aircraft, is described. An all-weather F-106B is instrumented to document the EM characteristics of direct and nearby strikes, measure the field parameters and analyze the ambient atmospheric content, and film the strikes; X-ray detectors are also on board, along with instrumentation for determining the frequency of visible light waveforms. Data is either recorded on-board or sent by telemetry to base, while ground based telemetry is used to direct the pilot and craft into regions of optimal lightning activity. The sensing apparatus is described, and ongoing programs to correlate different storm parameters are reviewed, along with operational procedures and safety precautions. Continued use of the craft through 152 storms and 16 direct hits, with no fatalities or circuit breaker throw, confirms the ability of metal skinned aircraft to withstand lightning strikes; data gathered from flights during 1980 are provided.

Deal, P. L.↗

Electrical safety for high voltage arrays

A number of key electrical safety requirements for the high voltage arrays of central station photovoltaic power systems are explored. The suitability of representative industrial DC power switchgear for control and fault protection was evaluated. Included were AC/DC circuit breakers, electromechanical contactors and relays, load interruptors, cold disconnect devices, sectionalizing switches, and high voltage DC fuses. As appropriate, steady state and transient characteristics were analyzed. Failure modes impacting upon operation and maintenance safety were also identified, as were the voltage withstand and current interruption levels.

Marshall, N. A.↗

Cleaning High-Voltage Equipment With Corncob Grit

High electrical resistance of particles makes power shutdown unnecessary. New, inexpensive method of cleaning high-voltage electrical equipment uses plentiful agricultural product - corncob grit. Method removes dirt and debris from transformers, circuit breakers, and similar equipment. Suitable for utilities, large utility customers, and electrical-maintenance services.

Caveness, C.↗

Design of high-voltage, high-power, solid state remote power controllers for aerospace applications

Two general types of remote power controllers (RPC's), which combine the functions of a circuit breaker and a switch, were developed for use in dc aerospace systems. Power-switching devices used in the designs are the gate-turnoff thyristor (GTO) and MOSFET. The RPC's can switch dc voltages to 1200 V and currents to 1000 A. Seven different units were constructed and subjected to laboratory and thermal vacuum testing. Two of these were dual units that switch both positive and negative voltages simultaneously. The RPC's using MOSFET's have slow turnon and turnoff times which limit surge currents and voltage spiking from high di/dt. The GTO's have much faster transition times. All RPC's have programmable overload tripout proportional to I sq T and microsecond tripout for large overloads.

Sturman, J. C.↗

Mobile Centers For Secondary Power Distribution

Concept for distribution of 60-Hz ac power in large building devoted to assembly and testing of equipment improves safety, reduces number of outlets and lengthy cables, and readily accommodates frequent changes in operations and configuration. Power from floor recess fed via unobtrusive cable to portable power management center. A cart containing variety of outlets and circuit breakers, wheeled to convenient location near equipment to be assembled or tested. Power distribution system presents larger range of operational configurations than fixed location. Meets tighter standards to feed computers and delicate instruments. Industrial-grade power suitable for power tools and other hardware. Three-phase and single-phase outlets available from each.

Mears, Robert L.↗

Current-Monitoring and -Limiting Circuit For 28-Vdc Supply

Current-monitoring and -limiting circuit protects 28-Vdc power supply against steady overload. Provides some protection against sudden peak currents. Acts as limiter, monitoring amplifier, and delayed-action circuit breaker. Consists of pair of power metal oxide/semiconductor field-effect transistors (MOSFET's).

Rodriguez, G. Ernest↗