Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLEAN ROOM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advanced life support study

Summary reports on each of the eight tasks undertaken by this contract are given. Discussed here is an evaluation of a Closed Ecological Life Support System (CELSS), including modeling and analysis of Physical/Chemical Closed Loop Life Support (P/C CLLS); the Environmental Control and Life Support Systems (ECLSS) evolution - Intermodule Ventilation study; advanced technologies interface requirements relative to ECLSS; an ECLSS resupply analysis; the ECLSS module addition relocation systems engineering analysis; an ECLSS cost/benefit analysis to identify rack-level interface requirements of the alternate technologies evaluated in the ventilation study, with a comparison of these with the rack level interface requirements for the baseline technologies; advanced instrumentation - technology database enhancement; and a clean room survey and assessment of various ECLSS evaluation options for different growth scenarios.

Source record↗

Laser Transmitter Module (LTM) for LITE

In Dec. 1991 TITAN SPECTRON successfully completed its six year effort to design, build, space qualify, test, and deliver the Laser Transmitter Module (LTM) for NASA LaRC's LITE program. The delivered LTM is a three color Q-switched flashlamp pumped Nd:YAG laser that is described as the first true world-class lidar in space. The preliminary design and verification tests results were first presented at the 14th International Laser Radar Conference (ILRC) in 1988. This paper describes not only the delivered product but also the verification and space qualification processes that resulted in the world's first space qualified high powered laser system for environmental exploration from space. Video of the laser operating in a Class 100 clean room and subsystems undergoing 10 G vibration tests will provide a vivid illustration of the key elements that separate a space qualified system from its laboratory counterpart. Flight laser performance measurements form the baseline in post-delivery test results to be presented at this conference.

Chang, John↗

Surface-Acoustic-Wave Piezoelectric Microbalance

Improved piezoelectric microbalances developed for use in measuring masses of volcanic, aerosol, and other small particles suspended in air. Sensitive microbalance used to analyze airborne particles in real time in environments as diverse as clean rooms or upper atmosphere. Surface-acoustic-wave resonator includes input and output sets of interdigitated electrodes and two passive conductive patterns acting as reflectors. Mechanical energy travels both ways out from middle and reflected back toward middle. Microbalance and associated circuitry fit in small package. Circuit draws only 80 mA at 5 V. Sensitivity more than 400 times that of bulk piezoelectric microbalance.

Chuan, Raymond L.↗

Reducing Airborne Debris In Wind Tunnels

In proposed technique to trap airborne particles during normal wind-tunnel testing, large sections of single-backed adhesive paper or cloth mounted with adhesive side exposed to flow. Adhesive material securely installed on flow vanes, walls, or other surfaces of wind tunnel in manner facilitating replacement. Installed or replaced anytime permissible to enter tunnel. Provides safe, inexpensive, rugged, passive, continuous, and otherwise inert cleansing action suitable for wind tunnel of any size. Also applied to specialized clean-room environments and to air-conditioning systems in general.

Sleeper, Robert K.↗

Fire protection for launch facilities using machine vision fire detection

Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

Schwartz, Douglas B.↗

Actuator Exerts Tensile Or Compressive Axial Load

Compact, manually operated mechanical actuator applies controlled, limited tensile or compressive axial force. Designed to apply loads to bearings during wear tests in clean room. Intended to replace hydraulic actuator. Actuator rests on stand and imparts axial force to part attached to clevis inside or below stand. Technician turns control screw at one end of lever. Depending on direction of rotation of control screw, its end of lever driven downward (for compression) or upward (for tension). Lever pivots about clevis pin at end opposite of control screw; motion drives downward or upward link attached via shearpin at middle of lever. Link drives coupling and, through it, clevis attached to part loaded.

Nozzi, John↗

Ventilating Air-Conditioner

Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

Dinh, Khanh↗

Marshall Space Flight Center head development program

This report summarizes the results of the candidate head evaluation for the new long-life magnetic head per the SOW of Contract No. NAS8-39407, MSFC Head Development Program. The original program plans were to test a candidate head, fabricate a new head, then qualify the new head. These activities were scheduled to be carried out between March 1993 and March 1994. The program was halted after the evaluation of the candidate head by NAS8-39407 Amendment No. 4. MSFC has provided and authorized the use the MARS-2000 SRB QUAL Recorder PN 10400-0677-801 - Serial Number 200004 (Datatape PN 591000 - Serial Number 1004), Reproduce Amplifier Module (RAM) Datatape PN 533040 - Serial Number 2006, associated cables, and magnetic tape on special SRB/DFI tapered reels to Datatape for this program. All the testing that has been done for the candidate head evaluation was done at Datatape's facility in Pasadena,CA. The testing was performed in a Class 100,000 particle counts clean room at ambient temperature, except for the thermal testing which was conducted in a different area at Datatape. The Performance Verification Test Procedure PVT-11004-4 (PVT) and Acceptance Test Procedure ATP-11004-09 (ATP) procedures were used when tests were conducted on the recorder.

Harrer, Jim↗

Applications of Thin Film Thermocouples for Surface Temperature Measurement

Thin film thermocouples provide a minimally intrusive means of measuring surface temperature in hostile, high temperature environments. Unlike wire thermocouples, thin films do not necessitate any machining of the surface, therefore leaving intact its structural integrity. Thin films are many orders of magnitude thinner than wire, resulting in less disruption to the gas flow and thermal patterns that exist in the operating environment. Thin film thermocouples have been developed for surface temperature measurement on a variety of engine materials. The sensors are fabricated in the NASA Lewis Research Center's Thin Film Sensor Lab, which is a class 1000 clean room. The thermocouples are platinum-13 percent rhodium versus platinum and are fabricated by the sputtering process. Thin film-to-leadwire connections are made using the parallel-gap welding process. Thermocouples have been developed for use on superalloys, ceramics and ceramic composites, and intermetallics. Some applications of thin film thermocouples are: temperature measurement of space shuttle main engine turbine blade materials, temperature measurement in gas turbine engine testing of advanced materials, and temperature and heat flux measurements in a diesel engine. Fabrication of thin film thermocouples is described. Sensor durability, drift rate, and maximum temperature capabilities are addressed.

Martin, Lisa C.↗

The use of computer models to predict temperature and smoke movement in high bay spaces

The Building and Fire Research Laboratory (BFRL) was given the opportunity to make measurements during fire calibration tests of the heat detection system in an aircraft hangar with a nominal 30.4 (100 ft) ceiling height near Dallas, TX. Fire gas temperatures resulting from an approximately 8250 kW isopropyl alcohol pool fire were measured above the fire and along the ceiling. The results of the experiments were then compared to predictions from the computer fire models DETACT-QS, FPETOOL, and LAVENT. In section A of the analysis conducted, DETACT-QS AND FPETOOL significantly underpredicted the gas temperature. LAVENT at the position below the ceiling corresponding to maximum temperature and velocity provided better agreement with the data. For large spaces, hot gas transport time and an improved fire plume dynamics model should be incorporated into the computer fire model activation routines. A computational fluid dynamics (CFD) model, HARWELL FLOW3D, was then used to model the hot gas movement in the space. Reasonable agreement was found between the temperatures predicted from the CFD calculations and the temperatures measured in the aircraft hangar. In section B, an existing NASA high bay space was modeled using the CFD model. The NASA space was a clean room, 27.4 m (90 ft) high with forced horizontal laminar flow. The purpose of this analysis is to determine how the existing fire detection devices would respond to various size fires in the space. The analysis was conducted for 32 MW, 400 kW, and 40 kW fires.

Notarianni, Kathy A.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Device For Sampling Surface Contamination

Specially designed cotton swab suitable for use in clean room. Contamination-sampling device improved version of basic cotton-tipped wooden applicator, designed for extreme cleanliness and to enhance utility for sampling according to exacting specifications. Device does not shed cotton and wood fibers.

Delgado, Felix A.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

STS-93 CEIT with crew in the OPF-3

The primary objective of the STS-93 mission was to deploy the Advanced X-ray Astrophysical Facility, which had been renamed the Chandra X-ray Observatory in honor of the late Indian-American Nobel Laureate Subrahmanyan Chandrasekhar. The mission was launched at 12:31 on July 23, 1999 onboard the space shuttle Columbia. The mission was led by Commander Eileen Collins. The crew was Pilot Jeff Ashby and Mission Specialists Cady Coleman, Steve Hawley and Michel Tognini from the Centre National d'Etudes Spatiales (CNES). This videotape shows parts of a crew briefing and an inspection tour of the clean room. The astronauts are shown examining some of the equipment and tools that they will use during the mission.

Source record↗

STS-93: Columbia/Chandra Crew Press Conference

This videotape consists of six different segments. The first segment is a close-up shot from Near-Earth Asteroid Rendezvous (NEAR) of the asteroid EROS. The second presents close-up shots of the Chandra telescope in the clean room. The third segment is an animated film showing the deployment of the Chandra telescope from the shuttle payload bay, and views of the elliptical orbit patterns that the telescope is planned to take. The fourth segment shows TRW Executive Vice President & General Manager, Systems & Information Technology Group, Donald Winter announcing the delivery of the Chandra Telescope to NASA. The fifth part was announced on the tape as an interview of Carolyn Griner, the Deputy Director of Marshall Space Flight Center, but this is not on the tape. The sixth segment shows views of the fourth United States Microgravity Payload (USMP-4) experiments. After shots of the STS-87 liftoff, the tape has views of the Isothermal Dendrite Growth Experiment (IDGE), views of the payload bay, and some further views of the astronauts working on one of the experiments in the payload.

Source record↗

STS-93: CEIT with Crew in the OPF-3

The primary objective of the STS-93 mission was to deploy the Advanced X-ray Astrophysical Facility, which had been renamed the Chandra X-ray Observatory in honor of the late Indian-American Nobel Laureate Subrahmanyan Chandrasekhar. The mission was launched at 12:31 on July 23, 1999 onboard the space shuttle Columbia. The mission was led by Commander Eileen Collins. The crew was Pilot Jeff Ashby and Mission Specialists Cady Coleman, Steve Hawley and Michel Tognini from the Centre National d'Etudes Spatiales (CNES). This videotape shows parts of a crew briefing and an inspection tour of the clean room. The astronauts are shown examining some of the equipment and tools that they will use during the mission. Views of the empty payload shuttle bay are presented.

Source record↗

STS-93: Crew Arrival and PR Location

The primary objective of the STS-93 mission was to deploy the Advanced X-ray Astrophysical Facility, which had been renamed the Chandra X-ray Observatory in honor of the late Indian-American Nobel Laureate Subrahmanyan Chandrasekhar. The mission was launched at 12:31 on July 23, 1999 onboard the space shuttle Columbia. The mission was led by Commander Eileen Collins. The crew was Pilot Jeff Ashby and Mission Specialists Cady Coleman, Steve Hawley and Michel Tognini from the Centre National d'Etudes Spatiales (CNES). This videotape shows the astronauts arriving at Kennedy and an inspection in the clean room.

Source record↗