Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLOCK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Progress Toward a Compact, Highly Stable Ion Clock

There was an update on the subject of two previous NASA Tech Briefs articles: Compact, Highly Stable Ion Clock (NPO-43075), Vol. 32, No. 5 (May 2008), page 63; and Neon as a Buffer Gas for a Mercury-Ion Clock (NPO-42919), Vol. 32, No. 7 (July 2008), page 62. To recapitulate: A developmental miniature mercury-ion clock has stability comparable to that of a hydrogen-maser clock. The ion-handling components are housed in a sealed vacuum tube, wherein a getter pump maintains the partial vacuum, and the evacuated tube is backfilled with mercury vapor in a neon buffer gas. There was progress in the development of the clock, with emphasis on the design, fabrication, pump-down, and bake-out of the vacuum tube (based on established practice in the travelingwave- tube-amplifier industry) and the ability of the tube to retain a vacuum after a year of operation. Other developments include some aspects of the operation of mercury-vapor source (a small appendage oven containing HgO) so as to maintain the optimum low concentration of mercury vapor, and further efforts to miniaturize the vacuum and optical subsystems to fit within a volume of 2 L.

Prestage, John↗

Byzantine-fault tolerant self-stabilizing protocol for distributed clock synchronization systems

A rapid Byzantine self-stabilizing clock synchronization protocol that self-stabilizes from any state, tolerates bursts of transient failures, and deterministically converges within a linear convergence time with respect to the self-stabilization period. Upon self-stabilization, all good clocks proceed synchronously. The Byzantine self-stabilizing clock synchronization protocol does not rely on any assumptions about the initial state of the clocks. Furthermore, there is neither a central clock nor an externally generated pulse system. The protocol converges deterministically, is scalable, and self-stabilizes in a short amount of time. The convergence time is linear with respect to the self-stabilization period.

Malekpour, Mahyar R.↗

TICTOC: Compact Atomic Clock with Integrated Photonics.

Atomic clocks are precision timekeeping devices that form the basis for modern communication and navigation. While many atomic clocks are room-sized systems requiring bulky free space optics and detectors, the Trapped-lon Clock using Technology-On-Chip (TICTOC) project integrates these components into Sandia's existing surface trap technology via waveguides for beam delivery and avalanche photodiodes for light detection. Taking advantage of a multi-ensemble clock interrogation approach, we expect to achieve record time stability (< 1 ns error per year) in a compact (< /1 2 L) clock. Here, we present progress on the development of the integrated devices and recent trapped ion demonstrations.

Ivory, Megan Kathleen↗

Low-power, miniature {sup 171}Yb ion clock using an ultra-small vacuum package

We report a demonstration of a very small microwave atomic clock using the 12.6 GHz hyperfine transition of the trapped {sup 171}Yb ions inside a miniature, completely sealed-off 3 cm{sup 3} ion-trap vacuum package. In the ion clock system, all of the components are highly miniaturized with low power consumption except the 369 nm optical pumping laser still under development for miniaturization. The entire clock, including the control electronics, consumes <300 mW. The fractional frequency instability of the miniature Yb{sup +} clock reaches the 10{sup -14} range after a few days of integration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Exploring Ramsey-coherent population trapping atomic clock realized with pulsed microwave modulated laser

A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Coherence of 2 Minutes and Instability of 1.5 × 10 −18 at 1 s in a Wannier-Stark Lattice Clock

We explore the limits of atomic coherence and measurement precision in a 87 Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice configuration, determining a 174(28) s 3 𝑃 0 clock state lifetime. Investigation of atomic coherence across a range of lattice depths and atomic densities reveals decoherence mechanisms related to photon scattering and atomic interaction. At a reduced density, we observe a coherence time of 118(9) s, approaching the fundamental limit set by spontaneous emission. Guided by this coherence understanding, we demonstrate a clock instability for an atomic ensemble of 1.5 × 10 −18 at 1 s in fractional frequency units. Our results are important for further advancing the state of the art of an optical lattice clock for fundamental physics applications.

atomic, optical, & lattice clocks↗

Impacts of random filling on spin squeezing via Rydberg dressing in optical clocks

Here, we analyze spin squeezing via Rydberg dressing in optical lattice clocks with random fractional filling. We compare the achievable clock stability in different lattice geometries, including unity-filled tweezer clock arrays and fractionally filled lattice clocks with varying dimensionality. We provide practical considerations and useful tools in the form of approximate analytical expressions and fitting functions to aid in the experimental implementation of Rydberg-dressed spin squeezing. We demonstrate that spin squeezing via Rydberg dressing in one-, two-, and three-dimensional optical lattices can provide significant improvements in stability in the presence of random fractional filling.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-stability compact atomic clock based on isotropic laser cooling

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of 2.2x10{sup -13{tau}-1/2} has been achieved, averaged down to 4x10{sup -15} after 5x10{sup 3} s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature and pressure shift of the Cs clock transition in the presence of buffer gases: Ne, N{sub 2}, Ar

The ground-state hyperfine resonance line of alkali-metal atoms is frequency shifted in the presence of noble or molecular gases. The buffer gases used in vapor-cell atomic clocks thus induce a temperature-dependent shift of the clock transition frequency. We report on measurements of the pressure and temperature dependence of the Cs clock transition frequency in the presence of Ne, Ar, and N{sub 2} buffer gases. The pressure in the sealed glass vapor cells is measured by means of the shift of the Cs D{sub 1} line. We have also investigated the temperature dependence of the optical shift. From these measurements, we infer the pressure and temperature coefficients of the hyperfine frequency shift. It is then possible to predetermine gas mixture ratios that cancel the temperature sensitivity at a given temperature. This prediction is confirmed experimentally for Ar-N{sub 2} mixtures. These results can be useful for improving the long-term frequency stability of Cs vapor-cell clocks.

74 ATOMIC AND MOLECULAR PHYSICS↗

Orientation-Dependent Entanglement Lifetime in a Squeezed Atomic Clock

We study experimentally the application of a class of entangled states, squeezed spin states, to the improvement of atomic-clock precision. In the presence of anisotropic noise, the entanglement lifetime is strongly dependent on squeezing orientation. We measure the Allan deviation spectrum of a clock operated with a phase-squeezed input state. For averaging times up to 50 s the squeezed clock achieves a given precision 2.8(3) times faster than a clock operating at the standard quantum limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10{sup -17} Level

We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5x10{sup -17} after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10{sup -17} level, even for lattices as deep as 150 recoil energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Empirical Evaluation of GPS Clock Accuracy for Isochronous Droop-based Inverters

Grid-forming inverters rely upon an internal reference to regulate the grid 's voltage and frequency. Without a reliable reference, issues such as loss of synchronism, frequency instability, and unequal power sharing can occur. One proposed internal phase reference for grid-forming inverters is generated by the controller's clock, but this is affected by nonidealities in the crystal oscillator leading to time drift in the phase reference. To improve the controller's clock accuracy, the Global Positioning System (GPS) can be used to calibrate the internal clock. Previously, GPS-based clock calibration was explored theoretically and various methods were developed for mitigating frequency/phase drift at the power system level. This paper experimentally validates the direct performance of GPS time-calibration at the controller level and justifies its use in maintaining an accurate phase reference for droop-based grid-forming inverters.

clock drift↗

Optical Square-Wave Clock Generation Based on an All-Optical Flip-Flop

We demonstrate optical square-wave clock generation based on an all-optical flip-flop. The bistable output power from a resonant-type semiconductor optical amplifier (SOA) is switched ON and OFF by modulating its input with its output via cross-gain modulation in a traveling-wave SOA. All active components are driven by dc currents, and the wavelength and clock frequency are selectable. A clock frequency of 3.5 MHz is demonstrated, limited by the time of flight between bulk optical components. Optical square-wave clock signals are promising for applications in photonic integrated circuits and all-optical signal processing.

Clocks, flip-flops, optical bistability, optical s↗

Low-Jitter Clock Receivers for Fast Timing Applications

Precision timing is a key requirement for emerging 4D particle tracking, Positron Emission Tomography (PET), beam and fusion plasma diagnostics, and other systems. Time-to-Digital Converters (TDCs) are commonly used to provide digital estimates of the relative timing between events, but the jitter performance of a TDC can be no better than the performance of the circuits that acquire the pulses and deliver them to the TDC. Several clock receiver and distribution circuits were evaluated, and a differential amplifier with resistive loads driving a pseudo-differential clock distribution network, developed using design guidelines for radiation tolerance and cryogenic compatibility, was fabricated as part of three prototypes: an analog front-end testbed chip for high-precision timing pixel readout, a dedicated TDC evaluation chip, and a Low-Gain Avalanche Detector (LGAD) readout circuit. Based on TDC measurements of the prototypes, we infer that the jitter added by the clock receiver and distribution circuits is less than 2.25 ps-rms. This performance meets the requirements of many future precision timing systems. The clock receiver and on-chip pseudo-differential driver were fabricated in commercial 28-nm CMOS technology and occupy 2288 µm 2 .

47 OTHER INSTRUMENTATION↗

The development of a Kalman filter clock predictor

A Kalman filter based clock predictor is developed, and its performance evaluated using both simulated and real data. The clock predictor is shown to possess a neat to optimal Prediction Error Variance (PEV) when the underlying noise consists of one of the power law noise processes commonly encountered in time and frequency measurements. The predictor's performance is the presence of multiple noise processes is also examined. The relationship between the PEV obtained in the presence of multiple noise processes and those obtained for the individual component noise processes is examined. Comparisons are made with a simple linear clock predictor. The clock predictor is used to predict future values of the time offset between pairs of NPL's active hydrogen masers.

clock predictor↗

Compact Microwave Mercury Ion Clock for Space Applications

We review progress in developing a small Hg ion clock for space operation based on breadboard ion-clock physics package where Hg ions are shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10(exp -13) at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required or holding 1-2x10(exp -13) at 1 second. We have completed an ion clock physics package designed to withstand vibration of launch and are currently building a approx. 1 kg engineering model for test. We also discuss frequency steering software algorithms that simultaneously measure ion signal size and lamp light output, useful for long term operation and self-optimization of microwave power and return engineering data.

navigation↗