Search NASA⌕ Search

SEARCH · Search NASA

Results for “COHERENT LIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Femtosecond diffraction studies of the sodium chloride phase diagram under laser shock compression

The phase diagram of sodium chloride (NaCl) under laser shock compression has been studied at Linac Coherent Light Source (LCLS) at the x-ray free-electron laser facility. Both solid–solid (B1 → B2) and solid–liquid (B2 → liquid) transitions have been observed along the Hugoniot over nanosecond time scales. By combining structural measurements through in situ x-ray diffraction, pressure determination through velocimetry, and a thermal equation-of-state, the shock-compressed data are used to constrain the phase diagram of NaCl. Transformation into the B2 phase is found to occur at 28(2) GPa, and B2–liquid coexistence is observed between 54(4) and 66(6) GPa, with near full melt at 66(6) GPa. Late-time pressure release from an initial shocked B2-state results in a B2 → B1 back transformation. Our results show agreement with previous static compression data, suggesting that the time scale for melting is very rapid and that equilibrium states in NaCl are being accessed over nanosecond time scales. Finally, a multiphase equation-of-state description of NaCl incorporated into a one-dimensional hydrocode is used to interpret pressure and temperature evolution over these rapid time scales.

36 MATERIALS SCIENCE↗

Tracking structural solvent reorganization and recombination dynamics following e – photoabstraction from aqueous I – with femtosecond x-ray spectroscopy and scattering

Here we present a sub-picosecond resolved investigation of the structural solvent reorganization and geminate recombination dynamics following 400 nm two-photon excitation and photodetachment of a valence p electron from the aqueous atomic solute, I–(aq). The measurements utilized time-resolved X-ray Absorption Near Edge Structure (TR-XANES) spectroscopy and X-ray Solution Scattering (TR-XSS) at the Linac Coherent Light Source x-ray free electron laser in a laser pump/x-ray probe experiment. The XANES measurements around the L 1 -edge of the generated nascent iodine atoms (I 0 ) yield an average electron ejection distance from the iodine parent of 7.4 ± 1.5 Å with an excitation yield of about 1/3 of the 0.1M NaI aqueous solution. The kinetic traces of the XANES measurement are in agreement with a purely diffusion-driven geminate iodine–electron recombination model without the need for a long-lived (I 0 :e–) contact pair. Nonequilibrium classical molecular dynamics simulations indicate a delayed response of the caging H 2 O solvent shell and this is supported by the structural analysis of the XSS data: We identify a two-step process exhibiting a 0.1 ps delayed solvent shell reorganization time within the tight H-bond network and a 0.3 ps time constant for the mean iodine–oxygen distance changes. The results indicate that most of the reorganization can be explained classically by a transition from a hydrophilic cavity with a well-ordered first solvation shell (hydrogens pointing toward I–) to an expanded cavity around I 0 with a more random orientation of the H 2 O molecules in a broadened first solvation shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic heat generation in semiconductors: Non-equilibrium excitation and evolution of zone-edge phonons via electron–phonon scattering in photo-excited germanium

We investigate experimentally and using first-principles theory the generation of phonons and the relaxation of carriers on picosecond timescales across the Brillouin zone of photo-excited Ge by inter-valley electron–phonon scattering. The phonons generated are typical of those generated in semiconductor devices, contributing to the accumulation of heat within the material. We simulate the time-evolution of phonon populations, based on first-principles band structure and electron–phonon and phonon–phonon matrix elements, and compare them to data from time-resolved x-ray diffuse scattering experiments, performed at the Linac Coherent Light Source x-ray free-electron laser facility, following photo-excitation by a 50 fs near-infrared optical pulse. We show that the intensity of the non-thermal x-ray diffuse scattering signal, which is observed to grow substantially near the L-point of the Brillouin zone over 3–5 ps, is due to phonons generated by scattering of carriers between the Δ and L valleys. These phonons have low group velocities, resulting in a heat bottleneck. With the inclusion of phonon decay through 3-phonon processes, the simulations also account for other non-thermal features observed in the x-ray diffuse scattering intensity, which are due to anharmonic phonon–phonon scattering of the phonons initially generated by electron–phonon scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Behavior of soda-lime silicate glass under laser-driven shock compression up to 315 GPa

Shock experiments give a unique insight into the behavior of matter subjected to extremely high pressures and temperatures. Understanding the behavior of materials under such extreme conditions is key to modeling material failure and deformation dynamics under impact. While studies on pure silica are extensive, the shock behavior of other commercial silicates that contain additional oxides has not been systematically investigated. To better understand the role of composition in the dynamic behavior of silicates, we performed laser-driven dynamic compression experiments on soda-lime glass (SLG) up to 315 GPa. Using the accurate pulse shaping offered by the long pulse laser system at the Matter in Extreme Conditions end-station at the Linac Coherent Light Source, SLG was shock compressed along the Hugoniot to multiple pressure-temperature points. Velocity Interferometer System for Any Reflector was used to measure the velocity and determine the pressure inside the SLG. The U s –u p relationship obtained agrees well with the previous parallel plate impact studies. Within the error bars, no transformation to the crystalline phase was observed up to 70 GPa, which is in contrast to the behavior of pure silica under shock compression. Our studies show that the glass composition strongly influences the shock compression behavior of the silicate glasses.

36 MATERIALS SCIENCE↗

Fast and flexible control of beam longitudinal phase space for high-repetition-rate x-ray free-electron lasers

The wide-ranging requirements for the photon properties from multiple beamlines in superconducting based free-electron lasers (FELs) demand more challenging beam manipulation techniques. Shot-by-shot control of electron beam bunch length and peak current at high repetition rate up to megahertz is highly desired. In this paper, we present a comprehensive study of a method based on a 2-m-long normal conducting radio-frequency cavity to achieve fast and flexible control of beam compression and realize the full potential of the facility, including theoretical analysis, beam dynamics simulations, and conceptual cavity design for the Linac Coherent Light Source II and its high-energy upgrade. We illustrate the physical mechanism of the chirping cavity on the control of the final beam compression and propose methods to lower the requirements for the cavity parameters. The application of this method will allow tailored photon properties of individual beamlines to optimize their performance and drastically improve the multiplexing capabilities of a high-repetition rate FEL facility.

42 ENGINEERING↗

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗

Study of ablation and shock generation across three orders of magnitude of laser intensity with 100 ps laser pulses

The laser ablation and subsequent shock generation in solid targets plays an important role in a variety of research topics from equation of state models for materials to inertial confinement fusion. One of the long-standing issues is the knowledge of ablation depth in the picosecond time regime. Here, we report on a direct technique for determining the ablation depth in aluminum using x-ray diffraction data from Linac Coherent Light Source at the Stanford Linear Accelerator Center. This technique gives a direct measurement of the shock wave propagation in the bulk target, enabling an ability to discern early timescale physics from late timescale effects not available in postmortem analysis. We find that the ablation depths only vary by 0.2 μm across three orders of magnitude of laser intensity, while the pressure increased by a factor of 10 following a square root dependence on laser pulse energy. We further observe that the ablation depth in this intensity range (10 11 –10 13 W/cm 2 in intensity, corresponding to 0.8–80 J/cm 2 in fluence) cannot be modeled by a universal scaling law, given the complexity of the mechanisms governing laser ablation in this intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward model-free temperature diagnostics of warm dense matter from multiple scattering angles

Warm dense matter plays an important role in astrophysical objects and technological applications, but the rigorous diagnostics of corresponding experiments is notoriously difficult. In this work, we present a model-free analysis of x-ray Thomson scattering (XRTS) measurements on isochorically heated graphite obtained at the Linac Coherent Light Source at multiple scattering angles. We demonstrate that the recent imaginary-time thermometry technique works for scattering data that have been measured in both forward and backward scattering geometry. This opens up the way toward a rigorous quantification of nonequilibrium effects in future experiments, where XRTS measurements are being obtained from multiple scattering angles from the same sample.

Equations of state↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

The X-ray Focusing System at the Time-Resolved AMO Instrument

The emergence of X-ray Free Electron Lasers (XFELs) in recent years has opened up new fields of research, with the merging of short wavelengths and ultrafast timescales. As XFEL facilities including the Linac Coherent Light Source (LCLS) have matured, there is renewed interest in pushing the performance boundaries of experimental endstations, as well as improving ease of operation for experiments. One of the major areas of improvement is that of X-ray micro- and nano-focusing. The focus quality is directly linked to the peak intensity at the interaction point with a sample, and is especially important for intensity-dependent (e.g. x-ray pump) studies and imaging efforts such as single particle imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCLS Big Data Handling – How I Learned to Stop Worrying and Love the Data Deluge

Advanced data and computing systems are vital to Linac Coherent Light Source (LCLS) operations, data interpretation and overall scientific productivity. The transition to MHz-era operation marks a fundamental change in scale that requires new infrastructure and architectures to link LCLS to the required scale of computing needed for scientific interpretation. The LCLS-II Data System meets big data challenges by implementing configurable data reduction that can adapt to multiple science areas, real-time analysis frameworks to provide visualization and fast feedback, and the ability to transfer data to local and remote computational facilities for near real time analysis at the appropriate scale. Feature extracted information generated in the data analysis pipeline - at the edge, local compute, or remote High-Performance Computing (HPC) resources - can be used to steer experiments and inform user decisions during beam time. Artificial Intelligence and Machine Learning (AI/ML) techniques present new opportunities to rapidly analyse large datasets and direct experiments, but create new challenges in scaling, adaptability, complexity, and trustworthiness. We describe how the LCLS-II Data System architecture addresses its data-driven challenges in the areas of data acquisition, data processing, data management, and workflow orchestration to decrease the overall time-to-science and provide a vision for future developments.

artificial intelligence↗

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

High pressure phase transition and strength estimate in polycrystalline alumina during laser-driven shock compression

Alumina (Al 2 O 3 ) is an important ceramic material notable for its compressive strength and hardness. It represents one of the major oxide components of the Earth's mantle. Static compression experiments have reported evidence for phase transformations from the trigonal α-corundum phase to the orthorhombic Rh 2 O 3 (II)-type structure at ~90 GPa, and then to the post-perovskite structure at ~130 GPa, but these phases have yet to be directly observed under shock compression. In this work, we describe laser-driven shock compression experiments on polycrystalline alumina conducted at the Matter in Extreme Conditions endstation of the Linac Coherent Light Source. Ultrafast x-ray pulses (50 fs, 10 12 photons/pulse) were used to probe the atomic-level response at different times during shock propagation and subsequent pressure release. At 107 ± 8 GPa on the Hugoniot, we observe diffraction peaks that match the orthorhombic Rh 2 O 3 (II) phase with a density of 5.16 ± 0.03 g cm –3 . Upon unloading, the material transforms back to the α-corundum structure. Upon release to ambient pressure, densities are lower than predicted assuming isentropic release, indicating additional lattice expansion due to plastic work heating. Furthermore, using temperature values calculated from density measurements, we provide an estimate of alumina's strength on release from shock compression.

33 ADVANCED PROPULSION SYSTEMS↗

Ionizing photon interactions modulate the optical properties of crystals with femtosecond scale temporal resolution

In this work, we continue our study of a new method for the detection of ionizing radiation with the potential for a dramatic improvement in coincidence time resolution (CTR) for time-of-flight positron emission tomography (ToF-PET) using the modulation of a material's optical properties instead of the scintillation mechanism. Our previous work has shown that for non-scintillation materials such as bismuth silicon oxide (BSO) and cadmium telluride (CdTe), their refractive index can be modulated by annihilation photon interactions. Additionally, the ultrafast nature of this process however remains unexplored. The ionizing radiation-induced charge carriers alter the local band structure in these materials, thus changing the complex refractive index. This mechanism is routinely used at the linac coherent light source (LCLS) facility of the SLAC National Accelerator Laboratory to measure x-ray pulse arrival times with femtosecond scale resolution for photon energies between 0.5 and 10 keV. The method described here follows that example by using a frequency chirped visible continuum pulse to provide a monotonic wavelength-to-time mapping by which one can measure the time-dependent refractive index modulation. In addition, we describe an interference-based measurement setup that allows for significantly improved sensitivity while preserving a timing precision of approximately 10 fs (σ) when measuring the arrival time of below 10 keV x-ray pulses with yttrium aluminum garnet (YAG) crystal. The method is presented in the context of ToF-PET application with further discussions on the potential CTR achievable if a similar detection concept is adopted for detecting 511 keV photons. Semi-empirical analysis indicates that the predicted CTR achievable is on the order of 1 ps (FWHM).

59 BASIC BIOLOGICAL SCIENCES↗

LCLS-II helium cryoplant and cryo distribution system installation

The helium cryoplant and cryo distribution system (CDS) are key elements of the new superconducting Linac Coherent Light Source (LCLS-II) and will provide superfluid helium to the accelerator. The cryoplant consists of two helium refrigerators with an equivalent 4.5 K refrigeration capacity of 18 kW each. The 37 cryomodules of the LINAC will be operated at a temperature of 2.0 K to accelerate a 4 GeV electron beam that will generate extremely bright X-ray laser light. Two five-stage cold compressor cold boxes will be utilized to provide superfluid helium II for the superconducting cavity structures with a total cooling capacity of 8 kW at 2.0 K. This paper describes the installation of the LCLS-II cryoplant and CDS. The LCLS-II cryoplant was designed and contributed by Jefferson Lab. To expedite the project completion the reuse of proven design and technology from the Jefferson Lab CHL-2 cryoplant was the preferred strategy. The CDS consists of ~260 m thermally shielded and vacuum super insulated transfer lines, two distribution boxes and eight feed and end caps, and was designed and contributed by Fermilab. SLAC installed the cryoplant components into a newly erected building and the CDS components into the existing accelerator tunnel and klystron gallery with strong engineering support from both partner labs.

43 PARTICLE ACCELERATORS↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗