Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMMAND SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

QQACCT

batchacct provides convenient library and command-line access to batch system accounting data for GridEngine and SLURM schedulers. It can be used to perform queries useful for data analysis of the accounting data alone or for integrative analysis in the context of a larger query.

Jacobsen, Douglas↗

An Introduction to UNIX, Emacs, Latex, and Python

This document is designed to give a brief introduction to the UNIX Operating System, Emacs, Latex, and Python. Section 1 focuses on UNIX, and presents the basics of the file system, a variety of common commands, and a handful of slightly more in depth topics. Section 2 introduces Emacs and its somewhat unusual keyboard controls. In Section 3, the basics of creating a document in Latex are demonstrated. Finally, Section 4 provides the foundation needed to begin programming in Python.

97 MATHEMATICS AND COMPUTING↗

Methods and system for a battery

Systems and methods for operating a redox flow battery system may include switching the redox flow battery system to an idle mode, wherein the idle mode includes operation of the redox flow battery system outside of a charging mode and outside of a discharge mode; in response to switching to the idle mode, repeatedly cycling operation of an electrolyte pump between an idling threshold flow rate less than a charging threshold flow rate and a deactivation threshold flow rate; and in response to switching to the charging mode, maintaining operation of the electrolyte pump at the charging threshold flow rate greater than the idling threshold flow rate. In this way, a responsiveness of the redox flow battery system to charging and discharging commands can be maintained while in idle, while reducing parasitic pumping losses due to pumping and heating, and reducing shunt current losses.

Song, Yang↗

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

FPGA implementation of high-frequency multiple PWM for variable voltage variable frequency controller

In this paper, we present the FPGA implementation of the multiple pulse width modulation (MPWM) signal generation with repetition of data segments, applied to the variable frequency variable voltage systems and specially at to the photovoltaic water pumping system, in order to generate a signal command very easily between 10 Hz to 60 Hz with a small frequency and reduce the cost of the control system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum-secured communications overlay for optical fiber communications networks

Quantum secure communication systems communicate quantum signals for quantum key distribution and classical signals with encrypted data and commands via a single optical fiber. In some systems, the single fiber carries classical data in both directions along with quantum communications. For example, quantum keys can be used to encrypt packets for bidirectional communication between two parties. In other systems, a single fiber is used for one way classical communications and quantum communications. The communication systems are secured using a security parameter based on the quantum and classical communications across the optical fiber.

Nordholt, Jane Elizabeth↗

A novel priority selection system for nuclear power plant - 287

The priority selection system is an important component of security level instrument control platform for nuclear power plant, the main function of which is priority processing the manual or automatic command with various security levels and driving engineering safety features and field devices, such as pump and valve. Its stability and safety plays a crucial role in the operation of the power plant. The main objective of the present paper is to describe the new nuclear power plant-oriented priority selection system, which is developed independently by China Nuclear Control System Engineering Company. In this system, the control commands from 1E DCS, ECP and DAS systems are transmitted via hardwire, while those from NC DCS are transmitted by field-bus. The control commands experience priority output to control the field actuators. Meanwhile, in order to control key field devices when failure of the instrument control systems occurs, the issuing interface for native instructions with permissions setting is also offered. The whole system provides collection-feedback functions for field devices, high coverage self-diagnostic functions and periodic test functions for safety systems. Moreover, the feedback information of field devices, the results of self-diagnosis and periodic test will be submitted to DCS of nuclear power plant. In addition, the core part of priority selection system, namely priority selection module, is obtained by pure FPGA technology, which is different from DCS systems and could avoid common cause failure of software effectively. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Secured control of circuit breakers in a digital substation

Methods and systems for secured control of circuit breakers in an electric power substation against undesired direct operation. Consequences of a malicious action are prevented or mitigated using a validation approach that either blocks the command or ensures a negligible effect on system operation. An example method, suitable for implementation in a monitoring device in an electric power substation, includes receiving a command to open or close a circuit breaker. In response, one or more state parameters for the electric power network that comprises the substation are then predicted, the predicted state parameters reflecting an operating state for the network under the assumption that the received command is executed. The method further comprises comparing the predicted one or more state parameters to corresponding operational limits. Execution of the command is then blocked, in response to determining that one or more of the predicted state parameters violate the corresponding operational limits.

Kondabathini, Anil↗

An Evaluation of Machine Learning Methods to Detect Malicious SCADA Communications

Critical infrastructure Supervisory Control and Data Acquisition (SCADA) systems were designed to operate on closed, proprietary networks where a malicious insider posed the greatest threat potential. The centralization of control and the movement towards open systems and standards has improved the efficiency of industrial control, but has also exposed legacy SCADA systems to security threats that they were not designed to mitigate. This work explores the viability of machine learning methods in detecting the new threat scenarios of command and data injection. Similar to network intrusion detection systems in the cyber security domain, the command and control communications in a critical infrastructure setting are monitored, and vetted against examples of benign and malicious command traffic, in order to identify potential attack events. Multiple learning methods are evaluated using a dataset of Remote Terminal Unit communications, which included both normal operations and instances of command and data injection attack scenarios.

critical infrastructure protection↗

Complex Failure Forewarning System - DHS Conference Proceedings

As the critical infrastructures of the United States have become more and more dependent on public and private networks, the potential for widespread national impact resulting from disruption or failure of these networks has also increased. Securing the nation s critical infrastructures requires protecting not only their physical systems but, just as important, the cyber portions of the systems on which they rely. A failure is inclusive of random events, design flaws, and instabilities caused by cyber (and/or physical) attack. One such domain, aging bridges, is used to explain the Complex Structure Failure Forewarning System. We discuss the workings of such a system in the context of the necessary sensors, command and control and data collection as well as the cyber security efforts that would support this system. Their application and the implications of this computing architecture are also discussed, with respect to our nation s aging infrastructure.

5th Annual University Network Summit↗

Forewarning of Failure in Complex Systems

As the critical infrastructures of the United States have become more and more dependent on public and private networks, the potential for widespread national impact resulting from disruption or failure of these networks has also increased. Securing the nation s critical infrastructures requires protecting not only their physical systems but, just as important, the cyber portions of the systems on which they rely. A failure is inclusive of random events, design flaws, and instabilities caused by cyber (and/or physical) attack. One such domain is failure in critical equipment. A second is aging bridges. We discuss the workings of such a system in the context of the necessary sensors, command and control and data collection as well as the cyber security efforts that would support this system. Their application and the implications of this computing architecture are also discussed, with respect to our nation s aging infrastructure.

99 GENERAL AND MISCELLANEOUS↗

Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks

Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

Preliminary proof-of-concept of real-time divertor heat flux control from infrared cameras with nitrogen injection in the DIII-D tokamak

In future tokamak reactors like ITER and the Fusion Pilot Plant (FPP), real-time feedback control of heat flux to the plasma-facing components (PFC) will be critical for steady-state operation. This work presents the first experimental demonstration of real-time divertor heat flux estimation with infrared thermography and feedback control with impurity seeding on the DIII-D tokamak. The flexible infrastructure of the Plasma Control System (PCS) on DIII-D makes this new capability possible. The PCS software runs on a gateway computer system, and five real-time compute nodes. An array of low latency streaming digitizers from D-TACQ Solutions connects to these real-time computers to collect and process data, and send commands to actuators during plasma discharges. This system handles the signal IO from the tokamak and allows the PCS to utilize the diagnostic data necessary to perform control in real-time. Feedback control on heat flux was accomplished by feeding infrared camera data from the “Infrared TV” (IRTV) camera to a custom-developed User Datagram Protocol (UDP) server. This server transmits infrared data to a newly developed PCS algorithm that estimates the heat flux to PFC. Here, a proportional integral derivative (PID) controller minimizes the error between a heat flux reference and the real-time estimate by injecting nitrogen gas into the divertor.

Algorithm development↗