Search NASA⌕ Search

SEARCH · Search NASA

Results for “COSMIC MUONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Detecting metal elements inside the dome of Santa Maria del Fiore in Florence using cosmic ray muons

As part of the ongoing study of Brunelleschi's great dome in Florence, the Opera di Santa Maria del Fiore has approved a proposal to solve the age-old problem of the possible presence of hoops or iron stirrups within the dome's inner wall by exploiting the flux of natural muons traversing the dome. Ascertaining presence of a metal hoop in the dome would of course be relevant to assess the static and seismic safety of the monument. The project, proposed by Dr. Elena Guardincerri from LANL and by Prof. Carlo Blasi, began in 2016 at LANL with the construction of special prototype-panels for the tracking of muons, and has expanded this year to include researchers from the Department of Physics of the University of Florence and INFN-Florence.

47 OTHER INSTRUMENTATION↗

Joint inversion of gravity and cosmic ray muon flux at a well-characterised site for shallow subsurface density prediction

Estimating subsurface density is important for imaging various geologic structures such as volcanic edifices, reservoirs, and aquifers. Muon tomography has recently been used to complement traditional gravity measurements as a powerful method for probing shallow subsurface density structure beneath volcanoes. Gravity and muon data have markedly different spatial sensitivities and, as a result, the combination is useful for imaging structures on spatial scales that are larger than the area encompassed by crossing muon trajectories. Here we explore and test a joint inversion of gravity and muon data in a study area where there is an independently-characterised target anomaly: a regionally extensive, high-density layer beneath Los Alamos, New Mexico, USA. We resolve the nearly flat-lying structure using a unique experimental set-up wherein surface and subsurface gravity and muon measurements are obtained above and below the target volume. Our results show that with minimal geologic (prior) constraints, the joint inversion correctly recovers salient features of the expected density structure. The results of our study illustrate the potential of combining surface and subsurface (e.g., borehole) gravity and muon measurements to invert for shallow geologic structures.

79 ASTRONOMY AND ASTROPHYSICS↗

First measurement of the yield of 8 He isotopes produced in liquid scintillator by cosmic-ray muons at Daya Bay

Here, Daya Bay presents the first measurement of cosmogenic 8 He isotope production in liquid scintillator, using an innovative method for identifying cascade decays of 8 He and its child isotope, 8 Li. We also measure the production yield of 9 Li isotopes using well-established methodology. The results, in units of 10 –8 μ –1 ⁢g –1 cm 2 , are 0.307 ± 0.042, 0.341 ± 0.040, and 0.546 ± 0.076 for 8 He, and 6.73 ± 0.73, 6.75 ± 0.70, and 13.74 ± 0.82 for 9 Li at average muon energies of 63.9 GeV, 64.7 GeV, and 143.0 GeV, respectively. The measured production rate of 8 He isotopes is more than an order of magnitude lower than any other measurement of cosmogenic isotope production. It replaces the results of previous attempts to determine the ratio of 8 He to 9 Li production that yielded a wide range of limits from 0% to 30%. The results provide future liquid-scintillator-based experiments with improved ability to predict cosmogenic backgrounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stopping rate of negative cosmic-ray muons near sea level.

A relatively simple method for measuring with high sensitivity the rate of stopped negative muons is described. A process in which Ar-37 is obtained from K-39 in connection with the stopping of a negative muon was used in the experiments. The Ar-37 activity can be measured in small proportional counters with extremely low backgrounds. It is possible to remove Ar-37 from potassium acetate powder at room temperature with almost 100 per cent efficiency merely by trapping the gas from the storage container with a charcoal trap at the liquid nitrogen temperature.

Spannagel, G.↗

Observation of an excess of cosmic ray muons of energies 2 TeV from the direction of Cygnus X-3

A high flux of muons from the Cygnus X-3 direction has been observed in NUSEX experiment at depths greater than 4600 hg/sq cm s.r. The excess muons show the 4.8 hour modulation in arrival time typical of this source. A study of this modulation was done in order to find the best value of the period and of the period derivative. The muon flux underground from NUSEX and SOUDAN (1800 hg/sq cm) experiments are used to determine the energy spectrum at sea level. The shape and the absolute intensities are found similar to those attributed to gamma rays responsible for production of air showers detected in direction of Cygnus X-3 in the energy range 10 to the 12th power to 10 to the 15th power eV.

Battistoni, G.↗

Absolute spectrum and charge ratio of cosmic ray muons in the energy region from 0.2 GeV to 100 GeV at 600 m above sea level

We have determined the momentum spectrum and charge ratio of muons in the region from 250 MeV/c to 100 GeV/c using a superconducting magnetic spectrometer. The absolute differential spectrum of muons obtained in this experiment at 600 m above sea level is in good agreement with the previous measurements at sea level. The differential spectrum can be represented by a power law with a varying index, which is consistent with zero below 450 MeV/c and steepens to a value of -2.7 +/- 0.1 between 20 and 100 GeV/c. The integral f1ux of muons measured in this experiment span a very large range of momentum and is in excellent agreement with the earlier results. The positive to negative muon ratio appears to be constant in the entire momentum range covered in this experiment within the errors and the mean value is 1.220 +/- 0.044. The absolute momentum spectrum and the charge ratio measured in this experiment are also consistent with the theoretical expectations. This is the only experiment which covers a wide range of nearly three decades in momentum from a very low momentum.

De Pascale, M. P.↗