High-energy proton imaging for biomedical applications

The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. As a result, tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic properties of monolayer tungsten disulfide grown by chemical vapor deposition

We demonstrate chemical vapor deposition of large monolayer tungsten disulfide (WS 2 ) (>200 μm). Photoluminescence and Raman spectroscopy provide insight into the structural and strain heterogeneity of the flakes. We observe exciton quenching at grain boundaries that originate from the nucleation site at the center of the WS 2 flakes. Temperature variable transport measurements of top-gated WS 2 transistors show an apparent metal-to-insulator transition. Variable range and thermally activated hopping mechanisms can explain the carrier transport in the insulating phase at low and intermediate temperatures. The devices exhibit room-temperature field-effect electron mobility as high as 48 cm 2 /V.s. The mobility increases with decreasing temperature and begins to saturate at below 100 °K, possibly due to Coulomb scattering or defects

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A generalized muon trajectory estimation algorithm with energy loss for application to muon tomography

Here, this work presents a generalized muon trajectory estimation (GMTE) algorithm to estimate the path of a muon in either uniform or nonuniform media. The use of cosmic ray muons in nuclear nonproliferation and safeguards verification applications has recently gained attention due to the non-intrusive and passive nature of the inspection, penetrating capabilities, as well as recent advances in detectors that measure position and direction of the individual muons before and after traversing the imaged object. However, muon image reconstruction techniques are limited in resolution due to low muon flux and the effects of multiple Coulomb scattering (MCS). Current reconstruction algorithms, e.g., point of closest approach (PoCA) or straight-line path (SLP), rely on overly simple assumptions for muon path estimation through the imaged object. For robust muon tomography, efficient and flexible physics-based algorithms are needed to model the MCS process and accurately estimate the most probable trajectory of a muon as it traverses an object. In the present work, the use of a Bayesian framework and a Gaussian approximation of MCS are explored for estimation of the most likely path of a cosmic ray muon traversing uniform or nonuniform media and undergoing MCS. The algorithm’s precision is compared to Monte Carlo simulated muon trajectories. It was found that the algorithm is expected to be able to predict muon tracks to less than 1.5 mm RMS for 0.5 GeV muons and 0.25 mm RMS for 3 GeV muons, a 50% improvement compared to SLP and 15% improvement when compared to PoCA. Further, a 30% increase in useful muon flux was observed relative to PoCA. Muon track prediction improved for higher muon energies or smaller penetration depth where energy loss is not significant. Finally, the effect of energy loss due to ionization is investigated, and a linear energy loss relation that is easy to use is proposed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of muon imaging with the LANL GMT detector for spent nuclear fuel cask content verification

Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Particle acceleration during classical phase transitions on a spherical lattice

Abstract When compressed, certain lattices undergo phase transitions that may allow nuclei to gain significant kinetic energy. To explore the dynamics of this phenomenon, we develop a methodology to study Coulomb coupled N -body systems constrained to a sphere, as in the Thomson problem. We initialize N total Boron nuclei as point particles on the surface of the sphere, allowing them to equilibrate via Coulomb scattering with a viscous damping term. To simulate a phase transition, we remove N rm particles, forcing the system to rearrange into a new equilibrium. With this model, we consider the Thomson problem as a dynamical system, providing a framework to explore how non-zero temperature affects structural imperfections in Thomson minima. We develop a scaling relation for the average peak kinetic energy attained by a single particle as a function of N and N rm . For certain values of N , we find an order of magnitude energy gain when increasing N rm from 1 to 6. The model may help to design a lattice that maximizes the energy output.

Bachmann, Aidan M. (ORCID:0000000294706404)↗

Beam dynamics challenges in linear colliders based on laser-plasma accelerators

In this paper we discuss design considerations and beam dynamics challenges associated with laser-driven plasma-based accelerators as applied to multi-TeV-scale linear colliders. Plasma accelerators provide ultra-high gradients and ultra-short bunches, offering the potential for compact linacs and reduced power requirements. We show that stable, efficient acceleration with beam quality preservation is possible in the nonlinear bubble regime of laser-plasma accelerators using beam shaping. Ion motion, naturally occuring for dense beams (i.e., low emittance and high energy) severely damps transverse beam instabilities. Coulomb scattering by the background ions is considered and it is shown that the strong focusing in the plasma strongly suppresses scattering-induced emittance growth. Finally, Betatron radiation emission from the transverse motion of the beam in the plasma will result in beam power loss and energy spread growth; however for sub-100 nm emittances, the beam power loss and energy spread growth will be sub-percent for multi-TeV-class plasma linacs.

47 OTHER INSTRUMENTATION↗

Theory of ultrafast photoinduced low-to-high spin crossover in divalent iron systems

Here a theory is developed for the ultrafast low-to-high spin transition in divalent iron. Following the photoinduced metal-to-ligand charge transfer (MLCT), the 1 A 1 MLCT state decays on a sub-100-fs timescale into the 5 T 2 MLCT using a 3 T 1 MLCT state as intermediary. Damping of nuclear motion is crucial in obtaining a full singlet-to-quintet transition mediated by the spin-orbit interaction. Destructive interference suppresses transitions to metal-centered (MC) states. The relaxation to the MC 5 T 2 is a result of Coulomb scattering with the surroundings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomalous magnetothermoelectric behavior in massive Dirac materials

Extensive studies of electron transport in Dirac materials have shown positive magnetoresistance (MR) and positive magnetothermopower (MTP) in a magnetic field perpendicular to the excitation current or thermal gradient. In contrast, measurements of electron transport often show a negative longitudinal MR and negative MTP for a magnetic field oriented along the excitation current or thermal gradient; this is attributed to the chiral anomaly in Dirac materials. In this paper, we report a very different magnetothermoelectric transport behavior in the massive Dirac material ZrTe5. Although thin flakes show a commonly observed positive MR in a perpendicular magnetic field, distinct from other Dirac materials, we observe a sharp negative MTP. In a parallel magnetic field, we still observe a negative longitudinal MR, however, a remarkable positive MTP is observed for the fields parallel to the thermal gradients. Our theoretical calculations suggest that this anomalous magnetothermoelectric behavior can be attributed to the screened Coulomb scattering. This work demonstrates the significance of impurity scattering in the electron transport of topological materials and provides deep insight into the magnetotransport phenomena in Dirac materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-Fermi-liquid behavior from partial nesting in multiorbital superconductors

We present that partial nesting between two connected or disconnected regions of the Fermi surface leads to fractional powers of the Coulomb scattering lifetime as a function of temperature. This result is first demonstrated for a toy band structure where partial nesting occurs within a single band and between different regions of the Brillouin zone. A comparison is then made to a multiband scenario by studying the scattering rate of an effective two-orbital model that was proposed in the context of multiorbital superconductors. In the process, various model independent features affecting the temperature exponent n are identified. The logarithmically divergent contributions of the lowest order vertex correction to the multiorbital susceptibility, and the role played by nesting in suppressing these divergences, is analyzed. Lastly, the relevance of these results is discussed keeping the recently observed anomalous resistivity in the Co doped iron superconductor LiFeAs as a backdrop.

36 MATERIALS SCIENCE↗

Cosmic ray radiography of the damaged cores of the Fukushima reactors

The passage of muons through matter is dominated by the Coulomb interaction with electrons and nuclei. The interaction with the electrons leads to continuous energy loss and stopping of the muons. The interaction with nuclei leads to angle “diffusion.” Two muon-imaging methods that use flux attenuation and multiple Coulomb scattering of cosmic-ray muons are being studied as tools for diagnosing the damaged cores of the Fukushima reactors. Here, we compare these two methods. We conclude that the scattering method can provide detailed information about the core. Lastly, attenuation has low contrast and little sensitivity to the core.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characteristics of Muon Computed Tomography of Used Fuel Casks Using Algebraic Reconstruction

Cosmic raymuons passing through matter lose energy from inelastic collisions with electrons and are deflected from nuclei due to multiple Coulomb scattering (MCS). The recent developments in position sensitive muon detectors that can measure incoming and outgoing trajectories of individual muons indicate that MCS could be an excellent candidate for spent nuclear fuel imaging. The main purpose of this paper is to evaluate tomographic scanning of spent nuclear fuel stored within vertical and horizontal dry storage casks. A quantitative analysis of the characteristics of images obtained with filtered back projection (FBP) and algebraic reconstruction techniques (ART) are presented herein, as such a comparison has not been carried out in the past. FBP is a fast tool to determine object boundaries. ART can include muon path models and prior knowledge that can improve resolution and reduce measurement time. The results demonstrate that missing fuel assemblies can be identified with more than 5 projections and that use of muon momentum significantly increases image resolution. It is expected that MCS can be used to successfully reconstruct the dry cask contents and allow identification of all described scenarios in hours. It is also expected that when total variation minimization and a non-local mean filter are applied, ART may yield much better image quality than FBP.

Liu, Zhengzhi↗

3-D Full-Band Monte Carlo Simulation of Hot-Electron Energy Distributions in Gate-All-Around Si Nanowire MOSFETs

The energy distributions of electrons in gate-all-around (GAA) Si MOSFETs are analyzed using full-band 3-D Monte Carlo (MC) simulations. Excellent agreement is obtained with experimental current–voltage characteristics. For these 24-nm gate length devices, the electron distribution features a smeared energy peak with an extended tail. This extension of the tail results primarily from the Coulomb scattering within the channel. A fraction of electrons that enter the drain retains their energy, resulting in an out-of-equilibrium distribution in the drain region. The simulated density and average energy of the hot electrons correlate well with experimentally observed device degradation. We propose that the interaction of high-energy electrons with hydrogen-passivated phosphorus dopant complexes within the drain may provide an additional pathway for interface-trap formation in these devices.

42 ENGINEERING↗

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-09: A Random Walk Model Algorithm for Proton Dose Calculation

Purpose: To develop a random walk model algorithm for calculating proton dose with balanced computation burden and accuracy. Methods: Random walk (RW) model is sometimes referred to as a density Monte Carlo (MC) simulation. In MC proton dose calculation, the use of Gaussian angular distribution of protons due to multiple Coulomb scatter (MCS) is convenient, but in RW the use of Gaussian angular distribution requires an extremely large computation and memory. Thus, our RW model adopts spatial distribution from the angular one to accelerate the computation and to decrease the memory usage. From the physics and comparison with the MC simulations, we have determined and analytically expressed those critical variables affecting the dose accuracy in our RW model. Results: Besides those variables such as MCS, stopping power, energy spectrum after energy absorption etc., which have been extensively discussed in literature, the following variables were found to be critical in our RW model: (1) inverse squared law that can significantly reduce the computation burden and memory, (2) non-Gaussian spatial distribution after MCS, and (3) the mean direction of scatters at each voxel. In comparison to MC results, taken as reference, for a water phantom irradiated by mono-energetic proton beams from 75 MeV to 221.28 MeV, the gamma test pass rate was 100% for the 2%/2mm/10% criterion. For a highly heterogeneous phantom consisting of water embedded by a 10 cm cortical bone and a 10 cm lung in the Bragg peak region of the proton beam, the gamma test pass rate was greater than 98% for the 3%/3mm/10% criterion. Conclusion: We have determined key variables in our RW model for proton dose calculation. Compared with commercial pencil beam algorithms, our RW model much improves the dose accuracy in heterogeneous regions, and is about 10 times faster than MC simulations.

60 APPLIED LIFE SCIENCES↗

SU-F-T-158: Experimental Characterization of Field Size Dependence of Dose and Lateral Beam Profiles of Scanning Proton and Carbon Ion Beams for Empirical Model in Air

Purpose: The Gaussian model for the lateral profiles in air is crucial for an accurate treatment planning system. The field size dependence of dose and the lateral beam profiles of scanning proton and carbon ion beams are due mainly to particles undergoing multiple Coulomb scattering in the beam line components and secondary particles produced by nuclear interactions in the target, both of which depend upon the energy and species of the beam. In this work, lateral profile shape parameters were fitted to measurements of field size dependence dose at the center of field size in air. Methods: Previous studies have employed empirical fits to measured profile data to significantly reduce the QA time required for measurements. From this approach to derive the weight and sigma of lateral profiles in air, empirical model formulations were simulated for three selected energies for both proton and carbon beams. Results: The 20%–80% lateral penumbras predicted by the double model for proton and single model for carbon with the error functions agreed with the measurements within 1 mm. The standard deviation between measured and fitted field size dependence of dose for empirical model in air has a maximum accuracy of 0.74% for proton with double Gaussian, and of 0.57% for carbon with single Gaussian. Conclusion: We have demonstrated that the double Gaussian model of lateral beam profiles is significantly better than the single Gaussian model for proton while a single Gaussian model is sufficient for carbon. The empirical equation may be used to double check the separately obtained model that is currently used by the planning system. The empirical model in air for dose of spot scanning proton and carbon ion beams cannot be directly used for irregular shaped patient fields, but can be to provide reference values for clinical use and quality assurance.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-04: Deriving Spot Shape Criteria for Proton Pencil Beam Scanning

Purpose: The shape of a single beam in proton PBS influences the resulting dose distribution. Spot profiles are modelled as two-dimensional Gaussian (single/ double) distributions in treatment planning systems (TPS). Impact of slight deviations from an ideal Gaussian on resulting dose distributions is typically assumed to be small due to alleviation by multiple Coulomb scattering (MCS) in tissue and superposition of many spots. Quantitative limits are however not clear per se. Methods: A set of 1250 deliberately deformed profiles with sigma=4 mm for a Gaussian fit were constructed. Profiles and fit were normalized to the same area, resembling output calibration in the TPS. Depth-dependent MCS was considered. The deviation between deformed and ideal profiles was characterized by root-mean-squared deviation (RMSD), skewness/ kurtosis (SK) and full-width at different percentage of maximum (FWxM). The profiles were convolved with different fluence patterns (regular/ random) resulting in hypothetical dose distributions. The resulting deviations were analyzed by applying a gamma-test. Results were compared to measured spot profiles. Results: A clear correlation between pass-rate and profile metrics could be determined. The largest impact occurred for a regular fluence-pattern with increasing distance between single spots, followed by a random distribution of spot weights. The results are strongly dependent on gamma-analysis dose and distance levels. Pass-rates of >95% at 2%/2 mm and 40 mm depth (=70 MeV) could only be achieved for RMSD<10%, deviation in FWxM at 20% and root of quadratic sum of SK <0.8. As expected the results improve for larger depths. The trends were well resembled for measured spot profiles. Conclusion: All measured profiles from ProBeam sites passed the criteria. Given the fact, that beam-line tuning can result shape distortions, the derived criteria represent a useful QA tool for commissioning and design of future beam-line optics.

07 ISOTOPE AND RADIATION SOURCES↗

Muon Tomography at Los Alamos [Slides]

This presentation includes a look at Cosmic-ray muon background, Mini Muon Tracker (MMT), and Muon interactions with matter. Which deals with Energy loss, Multiple Coulomb scattering, and Muon induced fission. This presentation also looks at Horizontal reactor imaging at Fukushima. With a greater look at Mock reactor, Fukushima simulations and measurements, UNMRR measurements, Japan NCA measurements, and Next steps to Fukushima. Lastly, discussed is Carbon fiber tubes and the future of muon tomography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurements of Inclusive Muon Neutrino Charged Current Differential Cross Sections on Argon at 0.8 GeV Average Neutrino Energy with the MicroBooNE Detector

Current and next-generation precision neutrino oscillation experiments aim to determine the neutrino mass ordering, to measure the extent of CP violation in the lepton sector and to probe beyond Standard Model physics, such as sterile neutrinos. These experiments rely on models for neutrino interactions with matter that are complicated by nuclear effects and final state interactions. To date, these effects cannot be modelled precisely, especially for heavy target nuclei, typically used in modern neutrino experiments. Many future experiments will employ detectors based on the liquid argon time projection chamber technology. As a consequence, neutrino-argon cross-section measurements are of the outmost importance, especially given the relative scarcity of neutrino-argon data, due to the novelty of the technology. This thesis presents the first measurement of muon-neutrino charged-current inclusive cross section on argon at a mean neutrino energy of 0.8 GeV. Data were collected using the MicroBooNE liquid argon time projection chamber in the Fermilab Booster neutrino beam during a period of six months, corresponding to an exposure of $1.6 \times 10^{20}$ protons on target. The measured cross section is presented as a function of the outgoing muon momentum, using multiple Coulomb scattering as a measurement technique, as well as the muon angle with respect to the beam direction. A comparison of the measured cross section obtained with two different configurations of the \textsc{Genie} neutrino event generator is performed, and better agreement is found when using nuclear-effect modelling in the theoretical calculations. Additionally, the total flux integrated cross section is measured to be $0.693 \pm 0.010 \, (\text{stat.}) \pm 0.165 \, (\text{syst.}) \times 10^{-38} \, \text{cm}^{2}$.