Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phase space distribution of halo particles and detection of WIMPS

We calculate the velocity distribution of halo particles using realistic models for the density profiles of the Galactic disk, spheroid, and halo components. We get the resulting velocity distribution, which is different from the Maxwellian distribution of isothermal halo. We investigate the consequences concerning the time averaged count rate and the amplitude of the annual modulation in WIMPS detection experiments. Compared to the previous estimate based on the Maxwellian distribution, the time averaged count rate is up to 40 percent larger. On the other hand, the amplitude of the annual modulation is up to a factor of two larger.

Ryu, Dongsu↗

Dead-time effects in microchannel-plate imaging detectors

The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

Zombeck, Martin V.↗

The Einstein X-ray Observatory Catalog of O-type stars

A catalog of X-ray count rates for all O-type stars surveyed by the Einstein Observatory is presented. The procedures by which the IPC and High Resolution Imager rates are converted to emitted X-ray luminosities are discussed in detail. The catalog contains 289 stars with 89 detections and 176 upper bounds for the observed count rates. Precise positions for 43 O-type stars are given whose previously known locations were unknown or erroneous. It is argued that most O-type stars are X-ray point sources, but some are possibly embedded in extended nebulae and/or bubbles. The X-ray spectra of O-type stars are discussed briefly, and it is argued that their mean spectrum can reasonably be taken as an 0.5 keV thermal bremsstrahlung model. It is argued that at least 30 percent of all O-type stars are variable in X-rays.

Chlebowski, T.↗

The scattered solar X-ray background of the ROSAT PSPC

A model for accurately reproducing the light curves and spectra of the scattered solar X-ray background (SB) affecting ROSAT XRT/PSPC pointed observations is presented and demonstrated. This procedure, the modeling and subtraction of the SB, is vital for analysis of all observations of extended X-ray objects and the soft X-ray diffuse background where noncosmic background constituents must be precisely known. At the orbital altitude of ROSAT, about 550 km, and the zenith angles at which the XRT/PSPC observers, 97 deg or less, the scattering is dominated by atomic oxygen with Thomson-scattered X-rays in the 1/4 keV band and oxygen K-alpha fluorescently scattered X-rays at 0.54 keV. This produces field-of-view-integrated minimum count rates in the 0.1-1.0 keV band of about 0.25 counts/s during dayside observations with excursions to about 40 counts/s or more in particularly bad geometries. Typical cosmic background count rates in the same band range from 3 to 12 counts/s, demonstrating the need for the procedure described here.

Snowden, S. L.↗

Preliminary Iron Distribution on Vesta

The distribution of iron on the surface of the asteroid Vesta was investigated using Dawn's Gamma Ray and Neutron Detector (GRaND) [1,2]. Iron varies predictably with rock type for the howardite, eucrite, and diogenite (HED) meteorites, thought to be representative of Vesta. The abundance of Fe in howardites ranges from about 12 to 15 wt.%. Basaltic eucrites have the highest abundance, whereas, lower crustal and upper mantle materials (cumulate eucrites and diogenites) have the lowest, and howardites are intermediate [3]. We have completed a mapping study of 7.6 MeV gamma rays produced by neutron capture by Fe as measured by the bismuth germanate (BGO) detector of GRaND [1]. The procedures to determine Fe counting rates are presented in detail here, along with a preliminary distribution map, constituting the necessary initial step to quantification of Fe abundances. We find that the global distribution of Fe counting rates is generally consistent with independent mineralogical and compositional inferences obtained by other instruments on Dawn such as measurements of pyroxene absorption bands by the Visual and Infrared Spectrometer (VIR) [4] and Framing Camera (FC) [5] and neutron absorption measurements by GRaND [6].

Mittlefehldt, David W.↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Tailoring spectral properties for entangled photon generation

The linear intensity scaling of entangled two-photon absorption (ETPA) offers a fundamental mechanism to enable nonlinear optical spectroscopy and microscopy under a substantially lower excitation power than is currently feasible. However, the long data acquisition time and low signal-to-noise ratio in reported ETPA-based spectroscopic and microscopic studies prevent its widespread application. To gain the full potential of this novel quantum light approach, it is essential to optimize entangled photon generation for significantly enhanced ETPA responses. Here, we report a new quantum light source by combining entangled photon generation with free-space femtosecond pump-pulse shaping. Here, through measurements of singles and coincidence counts by varying the patterns applied to a spatial light modulator to control the spectral widths of the pump pulses, we reveal strong dependence of the singles and coincidence count rates as well as their ratios on the spectral widths of pump pulses. An optimal spectral width for the highest ratios between the coincidence photon and the signal or idler photon count rates is also determined. Identification of such optimal spectral widths for entangled photon generation in the presence of postgeneration spectral selection makes this quantum light source a promising choice for ETPA-based spectroscopy and imaging.

Photon pairs & parametric down-conversion↗

Probable detection of solar neutrons by ground-level neutron monitors during STIP interval 16

The third solar neutron event detected by Earth-orbiting spacecraft was observed during STIP Interval XVI. The solar flare beginning at 2356 UT on 24 April l984 produced a variety of emissions including gamma rays and solar neutrons. The neutrons were observed by the SMM satellite and the neutron-decay protons were observed on the ISEE-3 spacecraft. Between 0000 and 0010 UT on 25 April an increase of 0.7 and 1.7 percent was recorded by neutron monitors at Tokyo (Itabashi) and Morioka, Japan. These stations were located about 42 degrees from the sub-solar point, and consequently, these is approximately 1400 grams of atmosphere between the incident neutrons at the top of the atmosphere and their detection on the Earth's surface. Nevertheless, the time coincidence of a small increase in the total counting rate of two independent neutron monitors indicates the presence of solar neutrons with energies greater than 400 MeV at the top of the Earth's atmosphere. The small increases in the counting rate emphasize the difficulty in identifying similar events using historical neutron monitor data.

Shea, M. A.↗

Use of Apollo 17 Epoch Neutron Spectrum as a Benchmark in Testing LEND Collimated Sensor

The Apollo 17 neutron experiment LPNE provided a unique set of data on production of neutrons in the Lunar soil bombarded by Galactic Cosmic Rays (GCR). It serves as valuable "ground-truth" in the age of orbital remote sensing. We used the neutron data attributed to Apollo 17 epoch as a benchmark for testing the LEND's collimated sensor, as introduced by the geometry of collimator and efficiency of He3 counters. The latter is defined by the size of gas counter and pressure inside it. The intensity and energy spectrum of neutrons escaping the lunar surface are dependent on incident flux of Galactic Cosmic Rays (GCR) whose variability is associated with Solar Cycle and its peculiarities. We obtain first the share of neutrons entering through the field of view of collimator as a fraction of the total neutron flux by using the angular distribution of neutron exiting the Moon described by our Monte Carlo code. We computed next the count rate of the 3He sensor by using the neutron energy spectrum from McKinney et al. [JGR, 2006] and by consider geometry and gas pressure of the LEND sensor. Finally the neutron count rate obtained for the Apollo 17 epoch characterized by intermediate solar activity was adjusted to the LRO epoch characterized by low solar activity. It has been done by taking into account solar modulation potential, which affects the GCR flux, and in turn changes the neutron albedo flux.

Chin, Gordon↗

Spatially Resolved, In Situ Carbon Isotope Analysis of Archean Organic Matter

Spatiotemporal variability in the carbon isotope composition of sedimentary organic matter (OM) preserves information about the evolution of the biosphere and of the exogenic carbon cycle as a whole. Primary compositions, and imprints of the post-depositional processes that obscure them, exist at the scale of individual sedimentary grains (mm to micron). Secondary ion mass spectrometry (SIMS) (1) enables analysis at these scales and in petrographic context, (2) permits morphological and compositional characterization of the analyte and associated minerals prior to isotopic analysis, and (3) reveals patterns of variability homogenized by bulk techniques. Here we present new methods for in situ organic carbon isotope analysis with sub-permil precision and spatial resolution to 1 micron using SIMS, as well as new data acquired from a suite of Archean rocks. Three analytical protocols were developed for the CAMECA ims1280 at WiscSIMS to analyze domains of varying size and carbon concentration. Average reproducibility (at 2SD) using a 6 micron spot size with two Faraday cup detectors was 0.4 %, and 0.8 % for analyses using 1 micron and 3 micron spot sizes with a Faraday cup (for C-12) and an electron multiplier (for C-13). Eight coals, two ambers, a shungite, and a graphite were evaluated for micron-scale isotopic heterogeneity, and LCNN anthracite (delta C-13 = -23.56 +/- 0.1 %, 2SD) was chosen as the working standard. Correlation between instrumental bias and H/C was observed and calibrated for each analytical session using organic materials with H/C between 0.1 and 1.5 (atomic), allowing a correction based upon a C-13H/C-13 measurement included in every analysis. Matrix effects of variable C/SiO2 were evaluated by measuring mm to sub-micron graphite domains in quartzite from Bogala mine, Sri Lanka. Apparent instrumental bias and C-12 count rate are correlated in this case, but this may be related to a crystal orientation effect in graphite. Analyses of amorphous Archean OM suggest that instrumental bias is consistent for 12C count rates as low as 10% relative to anthracite. Samples from the ABDP-9 (n=3; Mount McRae Shale, approximately 2.5 Ga), RHDH2a (n=2; Carrawine Dolomite and Jeerinah Fm, approximately 2.6 Ga), WRL1 (n=3; Wittenoom Fm, Marra Mamba Iron Formation, and Jeerinah Fm, approximately 2.6 Ga), and SV1 (n=1; Tumbiana Fm, approximately 2.7 Ga) drill cores, each previously analyzed for bulk organic carbon isotope composition, yielded 100 new, in situ data from Neoarchean sedimentary OM. In these samples, delta C-13 varies between -53.1 and -28.3 % and offsets between in situ and bulk compositions range from -8.3 to 18.8%. In some cases, isotopic composition and mode of occurrence (e.g. morphology and mineral associations) are statistically correlated, enabling the identification of distinct reservoirs of OM. Our results support previous evidence for gradients of oxidation with depth in Neoarchean environments driven by photosynthesis and methane metabolism. The relevance of these findings to questions of bio- and syngenicity as well as the alteration history of previously reported Archean OM will be discussed.

Williford, Kenneth H.↗

Effect of likelihood misspecification in Gaussian process-driven autonomous experimentation

In recent years, several groups have designed Autonomous Experiment (AE) models with the aim of using them as an alternative method for neutron scattering scanning. In an AE, Gaussian processes (GPs) are most frequently used due to their interpretability, their non-parametric nature, their universal approximation, and their closed-form predictive distribution. GPs have two key components, namely, the model for the likelihood of a neutron count knowing the underlying dynamic structure factor and the acquisition function. In this paper, we investigate the impact, on the quality of an AE, of the likelihood and acquisition function choices, in energy scans and (Q, ω) ones, with respect to the signal-over-noise ratio. While we hypothesized that the quality of GP predictions would decrease when the normal to Poisson likelihood approximation breaks down at low count rates, we found that the use of the correct Poisson likelihood does not improve the quality of the data collected, as well as yields very poor results in (Q, ω) scans at low count rates. In fact, the best results are obtained with a combination of normal likelihood, including the observation noise, and the change in variance acquisition function. In addition, we find that the performance, or quality of the predictive distribution, is a misleading measure of efficiency, that is, of the quality of the data collected.

Perryman, David Elliott [Inst. Laue-Langevin (ILL)↗

The Distribution of Non-Volatile Elements on Mars: Mars Odyssey GRS Results

The major scientific objective of the Gamma-Ray Spectrometer (GRS) on the 2001 Mars Odyssey Mission is to determine the distribution of elements in the near-surface of Mars. Mars Odyssey has been in its mapping orbit since February, 2002, and the GRS boom, which removes the instrument from the gamma-ray background of the spacecraft, was erected in June, 2002. In the 580 days since boom erection, we have accumulated 453 days of mapping data. The difference is due mostly to two times when Odyssey went into safe mode and the instrument warmed up forcing us to anneal out radiation damage that manifests itself after warming. Other data losses are due to simple transmitter data gaps and to intense solar particle events. The data from the GRS is statistical in nature. We have a very low count rate and a very low signal-to-noise ratio. With the exception of K, the most easily mapped elements have a signal/noise ratio on the order of 0.1 (0.5 for K) and the counting rates are on the order of 0.3 to 0.7 counts/min (4 cpm for K). In order to map the distribution of an element, we have to divide the total signal from Mars up into many cells that define the map s spatial resolution (unless the statistics are good enough that the intrinsic spatial resolution of the instrument, about 550 km diameter, dominates). The data for several elements have now achieved a statistical precision that permits us to make meaningful maps.

Boynton, W.↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing the X-Ray Microcalorimeter Spectrometer for Optimal Science Return

Recent advances in X-ray microcalorimeters enable a wide range of possible focal plane designs for the X-ray Microcalorimeter Spectrometer (XMS) instrument on the future Advanced X-ray Spectroscopic Imaging Observatory (AXSIO) or X-ray Astrophysics Probe (XAP). Small pixel designs (75 microns) oversample a 5-10" PSF by a factor of 3-6 for a 10 m focal length, enabling observations at both high count rates and high energy resolution. Pixel designs utilizing multiple absorbers attached to single transition-edge sensors can extend the focal plane to cover a significantly larger field of view, albeit at a cost in maximum count rate and energy resolution. Optimizing the science return for a given cost and/or complexity is therefore a non-trivial calculation that includes consideration of issues such as the mission science drivers, likely targets, mirror size, and observing efficiency. We present a range of possible designs taking these factors into account and their impacts on the science return of future large effective-area X-ray spectroscopic missions.

X-rays↗

Ammonia 15N/14N Isotope Ratio in the Jovian Atmosphere

Data from the Galileo Probe Mass Spectrometer has been used to derive the N-15/N-14 isotope ratio in ammonia at Jupiter. Although the mass spectral interference from the water contribution to 18 amu makes an accurate derivation of the (N-15)H3/(N-14)H3 ratio difficult from measurements of the singly ionized signals at 18 and 17 amu, this interference is not present in the doubly charged 8.5 and 9.0 amu signals from (N-14)H3++ and (N-15)H3++ respectively. Although the count rate from the 9 amu signal is low during the direct sampling of the atmosphere, the ammonia signal was considerably enhanced during the first enrichment cell (EC1) experiment that measured gas sampled between 0.8 and 2.8 bar. Count rates at 9 amu in the EC1 experiment reach 60/second and measure ammonia sampled from 0.88 to 2.8 bar. In the EC1 measurements the 8.5 amu signal is not measured directly, but can be calculated from the ammonia contribution to 17 amu and the ratio of NH3 ions of a double to single charged observed during a high resolution mass scan taken near the end of the descent. The high resolution scan gives this ratio from ammonia sampled much deeper in the atmosphere. These results are described and compared with Infrared Space Observatory-Short Wavelength Spectrometer (ISO-SWS) observations that give this ratio at 400 mbar.

Mahaffy, P.R.↗