Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Defense Waste Processing Facility Nitric-Glycolic Flowsheet Chemical Process Cell Chemistry: Part 2

The conversions of nitrite to nitrate, the destruction of glycolate, and the conversion of glycolate to formate and oxalate were modeled for the Nitric-Glycolic flowsheet using data from Chemical Process Cell (CPC) simulant runs conducted by Savannah River National Laboratory (SRNL) from 2011 to 2016. The goal of this work was to develop empirical correlation models to predict these values from measurable variables from the chemical process so that these quantities could be predicted a-priori from the sludge or simulant composition and measurable processing variables. The need for these predictions arises from the need to predict the REDuction/OXidation (REDOX) state of the glass from the Defense Waste Processing Facility (DWPF) melter. This report summarizes the work on these correlations based on the aforementioned data. Previous work on these correlations was documented in a technical report covering data from 2011-2015. This current report supersedes this previous report. Further refinement of the models as additional data are collected is recommended. The glass REDOX depends on the concentrations of nitrate and manganese (oxidants), and of glycolate, formate, oxalate, carbon, and antifoam (reductants) in the melter feed. The waste sludge contains nitrite, nitrate, manganese (Mn), and oxalate. Virtually all of the nitrite is converted to nitrate or NO+NO 2 +N 2 O gases in the CPC. The portion of the nitrite converted to nitrate increases the amount of nitrate in the sludge. The amount of glycolate in the final melter feed depends on the amount of the glycolic acid feed that is destroyed. Similarly, the amounts of formate and oxalate formed during the decomposition of glycolic acid are required. The material balance on carbon was found to not close in most cases. Generally, there was less carbon at the end of testing compared to the inputs. The most uncertain product variable was glycolate, so material balances were performed where the glycolate concentration was adjusted, usually upward, to close the balance. Correlation versus the original, as-measured, data was generally poor, but correlation against the material balance adjusted values was greatly improved. It was also shown that the correlation of the measured REDOX versus the predicted REDOX was much better when the material balance adjusted glycolate values were used. Three data series were primarily used during the regressions of the data; these series were 1) Sludge Batch 9 NG flowsheet simulant runs NG51-62 (SB9-NG); 2) Scaled Runs + Bounding Hydrogen Runs (SR+BH); and 3) Runs GN43-50 and 57 (43-50,57). The glycolate destruction was found to correlate with acid stoichiometry (AS), percent reducing acid (PRA), and for some data series, headspace to simulant volume ratio (HSV), mercury (Hg), and nitrate. Although glycolate destruction for pairs of data series (e.g., [SB9-NG] and [SR+BH]) were found to depend on HSV, the combination of all three data series was not found to have significant dependence on this variable. The best model for glycolate destruction depended on AS, nitrate, and Hg. This model predicted the product glycolate compositions of the data to within 92-106%. The conversion of glycolate to formate was high when noble metals and Hg were not present, with values up to 100%. When noble metals and Hg were present, this conversion ranged from zero to 7%, and was dependent on AS. Lower AS gave higher conversions to formate. The conversion to oxalate was found to depend on the AS and the initial concentration of nitrite. An alternative fit versus AS and the form of ruthenium (Ru) used is a possible alternative. This fit was somewhat less statistically significant. This second model predicts that more oxalate is formed when Ru-nitrosyl nitrate is used rather than Ru chloride. The conversion of glycolate to oxalate ranged from zero to 6%. The conversion of nitrite to nitrate depended primarily on AS and PRA, with HSV and Hg being significant when these variables were varied. For multiple series of data, nitrite was also needed to SRNL-STI-2017-00172 5HYLVLRQ viL distinguish between data series, and the effect of HSV became insignificant. The best model for nitrite to nitrate conversion depended on AS, PRA, nitrite, and Hg. The 95% confidence intervals on the predicted values of glycolate destruction, glycolate to oxalate conversion, and nitrite to nitrate conversion were used to determine the uncertainty in the predicted REDOX when starting with only the composition of the sludge, AS, and PRA. Using the 95% confidences on an individual value (that is the confidence in getting a particular value for one single test as opposed to what the mean would be for multiple tests), the uncertainty in the predicted REDOX was calculated. The uncertainty in the actual product composition glycolate, oxalate, formate, and nitrate concentrations translated to an uncertainty in the REDOX value of ±0.1,which is approximately the uncertainty claimed in the REDOX model itself.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SRNL Sludge Batch 10 Qualification SRAT and SME Off-Gas Results

Savannah River National Laboratory (SRNL) completed a small-scale demonstration of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) utilizing the nitric-glycolic acid (NGA) flowsheet to support Sludge Batch 10 (SB10) qualification. The demonstration utilized a Tank 51 slurry sample washed by SRNL (with added H-canyon material). The purpose of this document is to report the observed off-gas results from the demonstration. With the NGA flowsheet, DWPF has a CPC hydrogen generation limit of 2.4×10 -2 lb/h. The peak observed rate was nearly 90 times less than that limit during SRNL testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Chemical Slurry Rheology in DWPF Sludge Batch (SB) 10 Simulants

The Defense Waste Processing Facility (DWPF) treats high-activity radionuclides from sludge through a process called vitrification. This process converts radioactive liquid waste currently stored in tank farms into a solid glass form that is suitable for long-term storage and disposal. Due to the complexities involved in vitrifying this waste within each operation of the Chemical Processing Cell (CPC), waste rheology is studied to characterize the fluid-mechanical properties as it passes through the CPC and into the Melter. To better understand the waste and validate flow behavior, slurry rheology of simulants that represents the waste was studied at various acid stoichiometry percentages and solids concentrations to determine the simulant’s yield stress and viscosity. This research work has been supported by the DOE-FIU Science & Technology Workforce Development Initiative, an innovative program developed by the U.S. Department of Energy’s Office of Environmental Management (DOE-EM) and Florida International University’s Applied Research Center (FIU-ARC). During the spring of 2022, a DOE Fellow intern, Brendon Cintas, spent 10 weeks doing a summer internship at Savannah River National Laboratory (SRS) under the supervision and guidance of Dan Lambert, Chemical Flowsheet Development. The intern’s project was initiated on June 6, 2022, and continued through August 11, 2022 with the objective of assisting scientists at SRNL’s Rheology and Grout Laboratory at Aiken Country Technology Lab (ACTL) better understand the sludge composition on the rheology of a simulant slurry using a HAAKE RheoStress 6000 rheometer and extrapolate the results to the real-waste data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Texas A&M University Mobile Facility Measurements during TRACER (Field Campaign Report)

One of the main goals of the U.S Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) near Houston, Texas is to improve understanding of how meteorology and aerosols impact storm dynamical and microphysical processes in deep convection to better constrain and improve their model representation. The Houston area is strongly influenced by sea- and bay-breeze circulations that generate convergence and help to initiate and organize deep convection. To properly isolate and understand the roles of varied meteorological conditions and cloud condensation nuclei (CCN) and ice nucleation particles (INP) distributions in different air masses, co-located thermodynamic, kinematic, and aerosol vertical profile observations are needed. The focus of this campaign was to provide key measurements in air masses both in front of and behind sea/bay breeze fronts moving through the greater Houston area to sample the airmass heterogeneity. The overarching scientific goal of this campaign is to understand how the vertical distributions of both CCN and INP correspond to the inflow layer of deep convection in maritime, background continental, and polluted continental air masses, and how these variations influence deep convection. To fully sample the heterogeneity in both meteorological conditions and aerosols across the sea-breeze front (SBF), Texas A&M University (TAMU) deployed a InterMet 3050A 403 MHz mobile unit launching iMet-4 radiosondes and the new Rapid Onsite Atmospheric Measurement Van (ROAM-V) for aerosol sampling during the TRACER intensive operational period (IOP) from June to September 2022. The suite of instruments deployed on ROAM-V included a condensation particle counter (CPC; GRIMM Model 5.403 CPC), scanning mobility particle sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A differential mobility analyzer), cloud condensation nuclei counter (Droplet Measurement Technologies CCN counter), micropulse lidar (Droplet Measurement Technologies micropulse lidar [miniMPL]), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the Global Positioning System (GPS) on the phone application “My Altitude”. The DRUM data were collected as part of a closely related ARM field campaign and also supported by DOE Atmospheric System Research grant DE-SC0021047. The TAMU team sampled these airmass heterogeneities by strategically choosing deployment sites in a different airmass than the ARM fixed sites in La Porte and Guy, Texas. On days when the sea/bay breeze boundary was pushing inland, the TAMU team would usually sample the airmass on the maritime side of the SBF at a coastal site in Galveston, Texas in the early afternoon (1730-1900 UTC) and then move inland ahead of the SBF to sample the airmass on the continental side during late afternoon (2030-2230). Figure 1 shows the Galveston maritime site and the array of sites for the late afternoon continental measurements.

54 ENVIRONMENTAL SCIENCES↗

Sulfuric Acid New Particle Formation Field Campaign Report

This campaign aimed to measure gaseous sulfuric acid concentrations at the surface level using a newly developed sulfuric acid dimethylamine-reactive condensation particle counter (SAD-RCPC). Sulfuric acid is a key nucleation precursor and is the likely driving compound for new particle formation at the Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory. The SAD-RCPC will be deployed in the future at ARM SGP (AFC010010: "Vertically Resolved Nucleation Precursors at SGP") scheduled for 2024. The campaign was in conjunction with Eleanor Browne's campaign (AFC010075: Boundary-layer gradients in new particle formation) and took place from 05/7/23 to 5/21/23. The measured sulfuric acid concentrations by the SAD-RCPC will be compared to concentrations measured by Browne's chemical ionization mass spectrometer (CIMS). The SAD-RCPC consisted of a glass flow reactor coupled to a 1-nm diethylene glycol condensation particle counter (DEG CPC). Sampled air was mixed with a high concentration of dimethylamine vapor (~1 ppbv). Sulfuric acid within the sampled gas nucleated with dimethylamine to form detectable 1-nm particles. The measured particle concentration was converted to sulfuric acid concentration using nucleation reaction kinetics. The pulse height distribution of particles detected by the DEG CPC was observed using a multi-channel analyzer. Large pre-existing particles were separated from the freshly formed particles in the SAD-RCPC from the pulse height distribution (PHD). During the short campaign, seven new particle formation events were observed. The SAD-RCPC detected an increase in sulfuric acid concentration, but this also coincided with an increase in pre-existing <3 nm particle concentrations. In addition, Browne's CIMS detect sulfuric acid concentrations in the range of 10 5 -10 6 cm -3 .

54 ENVIRONMENTAL SCIENCES↗

TANK 7 CHARACTERIZATION AND WASHING STUDIES

A 3-L PUREX sludge sample from Tank 7 was characterized and then processed through a series of inhibited water washes to remove oxalate, sodium, and other soluble ions. Current plans use Tank 7 as one of the feed sources for Sludge Batch 7 (SB7). Tank 7 is high in oxalate due to the oxalic acid cleaning of the sludge heels from Tanks 5 and 6 and subsequent transfer to Tank 7. Ten decant and nine wash cycles were performed over a 47 day period at ambient temperature. Initially, seven decants and seven washes were completed based on preliminary estimates of the number of wash cycles required to remove the oxalate in the sludge. After reviewing the composition data, SRNL recommended the completion of 2 or 3 more decant/wash cycles to ensure all of the sodium oxalate had redissolved. In the first 7 washes, the slurry oxalate concentration was 12,300 mg/kg (69.6% oxalate removal compared to 96.1% removal of the other soluble ions). After all ten decants were complete, the slurry oxalate concentration was 3,080 mg/kg (89.2% oxalate removal compared to 99.0% of the other soluble ions). The rate of dissolution of oxalate increased significantly with subsequent washes until all of the sodium oxalate had been redissolved after seven decant/wash cycles. The measured oxalate concentrations agreed very well with LWO predictions for washing of the Tank 7 sample. Highlights of the analysis and washing of the Tank 7 sample include: (1) Sodium oxalate was detected in the as-received filtered solids. 95% of the oxalate was insoluble (undissolved) in the as-received slurry. (2) No sodium oxalate was detected in the post-wash filtered solids. (3) Sodium oxalate is the last soluble species that redissolves during washing with inhibited water. In order to significantly reduce the sodium oxalate concentration, the sludge must be highly washed, leaving the other soluble anions and cations (including sodium) very low in concentration. (4) The post-wash slurry had 1% of the soluble anions and cations remaining, with the exception of sodium and oxalate, for which the percentages were 2.8% and 10.8% respectively. The post-wash sodium concentration was 9.25 wt% slurry total solids basis and 0.15 M supernate. (5) The settling rate of slurry was very fast allowing the completion of one decant/wash cycle each day. (6) The measured yield stress of as-received (6.42 wt% undissolved solids) and post-wash (7.77 wt% undissolved solids) slurry was <1 Pa. For rapidly settling slurries, it can be hard to measure the yield stress of the slurry so this result may be closer to the supernate result than the slurry. The recommended strategy for developing the oxalate target for sludge preparation for Sludge Batch 7 includes the following steps: (1) CPC simulant testing to determine the percent oxalate destruction and acid mix needed to produce a predicted redox of approximately 0.2 Fe{sup +2}/{Sigma}Fe in a SME product while meeting all DWPF processing constraints. (2) Perform a DWPF melter flammability assessment to ensure that the additional carbon in the oxalate together with other carbon sources will not lead to a flammability issue. (3) Perform a DWPF glass paper assessment to ensure the glass produced will meet all DWPF glass limits due to the sodium concentration in the sludge batch. The testing would need to be repeated if a significant CPC processing change, such as an alternative reductant to formic acid, is implemented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PAPER STUDY EVALUATIONS OF THE INTRODUCTION OF SMALL COLUMN ION EXCHANGE WASTE STREAMS TO THE DEFENSE WASTE PROCESSING FACILITY

The objective of this paper study is to provide guidance on the impact of Monosodium Titanate (MST) and Crystalline Silicotitanate (CST) streams from the Small Column Ion Exchange (SCIX) process on the Defense Waste Processing Facility (DWPF) flowsheet and glass waste form. A series of waste processing scenarios was evaluated, including projected compositions of Sludge Batches 8 through 17 (SB8 through SB17), MST additions, CST additions to Tank 40 or to a sludge batch preparation tank (Tank 42 or Tank 51, referred to generically as Tank 51 in this report), streams from the Salt Waste Processing Facility (SWPF), and two canister production rates. A wide array of potential glass frit compositions was used to support this assessment. The sludge and frit combinations were evaluated using the predictive models in the current DWPF Product Composition Control System (PCCS). The results were evaluated based on the number of frit compositions available for a particular sludge composition scenario. A large number of candidate frit compositions (e.g., several dozen to several hundred) is typically a good indicator of a sludge composition for which there is flexibility in forming an acceptable waste glass and meeting canister production rate commitments. The MST and CST streams will significantly increase the concentrations of certain components in glass, such as Nb{sub 2}O{sub 5}, TiO{sub 2}, and ZrO{sub 2}, to levels much higher than have been previously processed at DWPF. Therefore, several important assumptions, described in detail in the report, had to be made in performing the evaluations. The results of the paper studies, which must be applied carefully given the assumptions made concerning the impact of higher Ti, Zr, and Nb concentrations on model validity, provided several observations: (1) There was difficulty in identifying a reasonable number of candidate frits (and in some cases an inability to identify any candidate frits) when a waste loading of 40% is targeted for Sludge Batches 8, 16, and 17, regardless of the addition of SCIX or SWPF streams. This indicates that the blending strategy for these sludge batches should be reevaluated by Savannah River Remediation (SRR). (2) In general, candidate frits were available to accommodate CST additions to either Tank 40 or Tank 51. A larger number of candidate frits were typically available for the sludge batches when CST is added to Tank 51 rather than Tank 40, meaning that more compositional flexibility would be available for frit selection and DWPF operation. Note however that for SB8 and SB17, no candidate frits were available to accommodate CST going to Tank 40 with and without SWPF streams. The addition of SWPF streams generally improves the number of candidate frits available for processing of a given sludge batch. (3) The change in production rate from 40 Sludge Receipt and Adjustment Tank (SRAT) batches per year (i.e., the current production rate) to 75 SRAT batches per year, without SWPF streams included, had varied results in terms of the number of candidate frits available for processing of a given sludge batch. Therefore, this variable is not of much concern in terms of incorporating the SCIX streams. Note that the evaluation at 75 SRAT batches per year (approximately equivalent to 325 canisters per year) is more conservative in terms of the impact of SCIX streams as compared to a production rate of 400 canisters per year. Overall, the outcome of this paper study shows no major issues with the ability to identify an acceptable glass processing window when CST from the SCIX process is transferred to either Tank 40 or Tank 51. The assumptions used and the model limitations identified in this report must be addressed through further experimental studies, which are currently being performed. As changes occur to the planned additions of MST and CST, or to the sludge batch preparation strategy, additional evaluations will be performed to determine the potential impacts. As stated above, the issues with Sludge Batches 8, 16, and 17 should be further evaluated by SRR. A review of Chemical Process Cell (CPC) processing identified no changes to the recommendations from the previous review of the SCIX process impacts. Recommendations for testing were made during the previous review to evaluate the impact of CST on the rheological properties of DWPF process streams and evaluate the impact of CST on catalytic hydrogen generation during CPC processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SLUDGE WASHING AND DEMONSTRATION OF THE DWPF FLOWSHEET IN THE SRNL SHIELDED CELLS FOR SLUDGE BATCH 6 QUALIFICATION

Prior to initiating a new sludge batch in the Defense Waste Processing Facility (DWPF), Savannah River National Laboratory (SRNL) is required to simulate this processing, including Chemical Process Cell (CPC) simulation, waste glass fabrication, and chemical durability testing. This report documents this simulation for the next sludge batch, Sludge Batch 6 (SB6). SB6 consists of Tank 12 material that has been transferred to Tank 51 and subjected to Low Temperature Aluminum Dissolution (LTAD), Tank 4 sludge, and H-Canyon Pu solutions. Following LTAD and the Tank 4 addition, Liquid Waste Operations (LWO) provided SRNL a 3 L sample of Tank 51 sludge for SB6 qualification. Pu solution from H Canyon was also received. SB6 qualification included washing the sample per LWO plans/projections (including the addition of Pu from H Canyon), DWPF CPC simulations, waste glass fabrication (vitrification), and waste glass characterization and chemical durability evaluation. The following are significant observations from this demonstration. Sludge settling improved slightly as the sludge was washed. SRNL recommended (and the Tank Farm implemented) one less wash based on evaluations of Tank 40 heel projections and projections of the glass composition following transfer of Tank 51 to Tank 40. Thorium was detected in significant quantities (>0.1 wt % of total solids) in the sludge. In past sludge batches, thorium has been determined by Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS), seen in small quantities, and reported with the radionuclides. As a result of the high thorium, SRNL-AD has added thorium to their suite of Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) elements. The acid stoichiometry for the DWPF Sludge Receipt and Adjustment Tank (SRAT) processing of 115%, or 1.3 mol acid per liter of SRAT receipt slurry, was adequate to accomplish some of the goals of SRAT processing: nitrite was destroyed to below 1,000 mg/kg and mercury was removed to below the DWPF target with 750 g of steam per g of mercury. However, rheological properties did not improve and were above the design basis. Hydrogen generation rates did not exceed DWPF limits during the SRAT and Slurry Mix Evaporator (SME) cycles. However, hydrogen generation during the SRAT cycle approached the DWPF limit. The glass fabricated with the Tank 51 SB6 SME product and Frit 418 was acceptable with respect to chemical durability as measured by the Product Consistency Test (PCT). The PCT response was also predictable by the current durability models of the DWPF Product Composition Control System (PCCS). It should be noted, however, that in the first attempt to make glass from the SME product, the contents of the fabrication crucible foamed over. This may be a result of the SME product's REDOX (Reduction/Oxidation - Fe{sup 2+}/{Sigma}Fe) of 0.08 (calculated from SME product analytical results). The following are recommendations drawn from this demonstration. In this demonstration, at the request of DWPF, SRNL caustic boiled the SRAT contents prior to acid addition to remove water (to increase solids concentration). During the nearly five hours of caustic boiling, 700 ppm of antifoam was required to control foaming. SRNL recommends that DWPF not caustic boil/concentrate SRAT receipt prior to acid addition until further studies can be performed to provide a better foaming control strategy or a new antifoam is developed for caustic boiling. Based on this set of runs and a recently completed demonstration with the SB6 Waste Acceptance Product Specifications (WAPS) sample, it is recommended that DWPF not add formic acid at the design addition rate of two gallons per minute for this sludge batch. A longer acid addition time appears to be helpful in allowing slower reaction of formic acid with the sludge and possibly decreases the chance of a foam over during acid addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifying a regional aerosol baseline in the eastern North Atlantic using collocated measurements and a mathematical algorithm to mask high-submicron-number-concentration aerosol events

Abstract. High-time-resolution measurements of in situ aerosol and cloud properties provide the ability to study regional atmospheric processes that occur on timescales of minutes to hours. However, one limitation to this approach is that continuous measurements often include periods when the data collected are not representative of the regional aerosol. Even at remote locations, submicron aerosols are pervasive in the ambient atmosphere with many sources. Therefore, periods dominated by local aerosol should be identified before conducting subsequent analyses to understand aerosol regional processes and aerosol–cloud interactions. Here, we present a novel method to validate the identification of regional baseline aerosol data by applying a mathematical algorithm to the data collected at the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility in the eastern North Atlantic (ENA). The ENA central facility (C1) includes an aerosol observing system (AOS) for the measurement of aerosol physical, optical, and chemical properties at time resolutions from seconds to minutes. A second temporary supplementary facility (S1), located ∼0.75 km from C1, was deployed for ∼1 year during the Aerosol and Cloud Experiments (ACE-ENA) campaign in 2017. First, we investigate the local aerosol at both locations. We associate periods of high submicron number concentration (Ntot) in the fine-mode condensation particle counter (CPC) and size distributions from the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) as a function of wind direction using a meteorology sensor with local sources. Elevated concentrations of Aitken-mode (< 100 nm diameter) particles were observed in correspondence with the wind directions associated with airport operations. At ENA, the Graciosa Airport and its associated activities were found to be the main sources of high-concentration aerosol events at ENA, causing peaks in 1 min Ntot that exceeded 8000 and 10 000 cm−3 at C1, in summer and winter, respectively, and 5000 cm−3 at S1 in summer. Periods with high Ntot not associated with these wind directions were also observed. As a result, the diverse local sources at ENA yielded a poor relationship between Ntot measurements collected at C1 and S1 (R2=0.03 with a slope =0.05±0.001). As a first approach to mask these events, the time periods when the wind direction was associated with the airport operations (west to northwest and southeast to south at C1 and east to south at S1) were applied. The meteorological masks removed 38.9 % of the data at C1 and 43.4 % at S1, and they did not significantly improve the relationship between the two sites (R2=0.18 with a slope =0.06±0.001). Due to the complexity of high-Ntot events observed at ENA, we develop and validate a mathematical ENA Aerosol Mask (ENA-AM) to identify high-Ntot events using 1 min resolution data from the AOS CPC at C1 and S1. After its parameterization and application, ENA-AM generated a high correlation between Ntot in the summer at C1 and S1 (R2=0.87 with a slope =0.84±0.001). We identified the regional baseline at ENA to be 428±228 cm−3 in the summer and 346±223 cm−3 in the winter. Lastly, we compared masked measurements from the AOS with the ARM Aerial Facility (AAF) during flights over C1 in the summer to understand submicron aerosol vertical mixing over C1. The high correlation (R2=0.71 with a slope of 1.04±0.01) observed between C1 and the AAF Ntot collected within an area of 10 km surrounding ENA and at altitudes < 500 m indicated that the submicron aerosol at ENA was well mixed within the first 500 m of the marine boundary layer during the month of July during ACE-ENA. Our novel method for determining a regional aerosol baseline at ENA can be applied to other time periods and at other locations with validation by a secondary site or additional collocated measurements.

54 ENVIRONMENTAL SCIENCES↗

The PERSIANN family of global satellite precipitation data: a review and evaluation of products

Abstract. Over the past 2 decades, a wide range of studies have incorporated Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks (PERSIANN) products. Currently, PERSIANN offers several precipitation products based on different algorithms available at various spatial and temporal scales, namely PERSIANN, PERSIANN-CCS, and PERSIANN-CDR. The goal of this article is to first provide an overview of the available PERSIANN precipitation retrieval algorithms and their differences. Secondly, we offer an evaluation of the available operational products over the contiguous US (CONUS) at different spatial and temporal scales using Climate Prediction Center (CPC) unified gauge-based analysis as a benchmark. Due to limitations of the baseline dataset (CPC), daily scale is the finest temporal scale used for the evaluation over CONUS. Additionally, we provide a comparison of the available products at a quasi-global scale. Finally, we highlight the strengths and limitations of the PERSIANN products and briefly discuss expected future developments.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗

Long-term measurement of bone strain in vivo: the rat tibia

Despite the importance of strain in regulating bone metabolism, knowledge of strains induced in bone in vivo during normal activities is limited to short-term studies. Biodegeneration of the bond between gauge and bone is the principle cause of this limitation. To overcome the problem of bond degeneration, a unique calcium phosphate ceramic (CPC) coating has been developed that permits long-term attachment of microminiature strain gauges to bone. Using this technique, we report the first long-term measurements of bone strain in the rat tibia. Gauges, mounted on the tibia, achieved peak or near peak bonding at 7 weeks. Measurements were made between 7-10 weeks. Using ambulation on a treadmill, the pattern and magnitude of strain measured in the tibia remained relatively constant between 7-10 weeks post implantation. That strain levels were similar at 7 and 10 weeks suggests that gauge bonding is stable. These data demonstrate that CPC-coated strain gauges can be used to accurately measure bone strain for extended periods, and provide an in vivo assessment of tibial strain levels during normal ambulation in the rat. Copyright 2001 John Wiley & Sons, Inc.

Non-programmatic↗

Development of Particulates and Aerosols Research

During the past year several accomplishments were made for both the Particulate Matter Characterization and Measurement System, (PMCMS) and PAGEMS projects. The PAGEMS focus is to measure particulate emissions as a function of combustor parameters such as inlet temperature, inlet pressure and fuel air ratio. These measurements are used to evaluate combustor performance in hopes of correlating particulate emissions with engine conditions. These measurements have taken place at in-house NASA combustor facilities and off-site facilities. Ths work is unique because particulate measurements at high- pressure conditions are not commonly made. Some calibration of the PAGEMS instrumentation was done as well as minor modifications to the PAGEMS plumbing setup. These led to measurement improvements. The instrumentation and measurement process for PAGEMS was assessed and new instruments such as a thermodenuder, thermal mass flow meters and a cyclone separator were purchased to improve the PAGEMS instrumentation and measurement process. A worksheet was created to simulate varying inlet conditions to the DMA. This worksheet allows the user to assess the error in the measurements when certain conditions exist. Two technical papers were written with the PAGEMS team for the EXCAVATE field project. A paper was also reviewed for an in house publication. Also data was processed and analyzed for another field project (PAX) and will be part of a third PAGEMS paper. Accomplishments were also made with the PMCMS project. The calibration of the radial differential mobility analyzer, (RDMA) in the particle sizing system in the PMCMS was completed and provided satisfactory results. The voltages used for the RDMA depending on the particle of interest were corrected. The measurement capability of the PMCMS was increased by replacing the MetOne CPC with a TSI CPC. Lastly, assistance was provided to three college summer students with calibration of their particulate equipment and Monica Rivera shared her understanding of the aerosol technology with them. She also provided input for their end of the summer presentations. And attended the Aviation and Particle Emissions workshop. This workshop brought together experts in the aircraft particulate emissions field. As a result Ms. Rivera made two significant contacts with academia (UMR) and government (WPAFB) which could lead to future collaboration. She also attended the Aerosol and Particle Measurement Class held at the University of Minnesota. This class refreshed her particulate knowledge and introduced her to new aerosol applications and technology. Furthermore at the class contacts were made with private industry (TSI) and government (WPAFB). Ms. Rivera also enhanced her education by taking an in-house class on aircraft design and operation.

DeWitt, Kenneth↗

Three dimensional empirical mode decomposition analysis apparatus, method and article manufacture

An apparatus and method of analysis for three-dimensional (3D) physical phenomena. The physical phenomena may include any varying 3D phenomena such as time varying polar ice flows. A repesentation of the 3D phenomena is passed through a Hilbert transform to convert the data into complex form. A spatial variable is separated from the complex representation by producing a time based covariance matrix. The temporal parts of the principal components are produced by applying Singular Value Decomposition (SVD). Based on the rapidity with which the eigenvalues decay, the first 3-10 complex principal components (CPC) are selected for Empirical Mode Decomposition into intrinsic modes. The intrinsic modes produced are filtered in order to reconstruct the spatial part of the CPC. Finally, a filtered time series may be reconstructed from the first 3-10 filtered complex principal components.

Gloersen, Per↗

The Land Surface in Current and Planned MERRA Reanalysis Products

Current global atmospheric reanalysis products such as the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5), the NASA Modern-Era Retrospective analysis for Research and Applications version 2 (MERRA-2), and the Japanese Reanalysis for Three Quarters of a Century (JRA-3Q) provide estimates of land surface states and fluxes, including soil moisture, soil temperature, snow mass, latent and sensible heat fluxes, and runoff, that are widely used in research and applications. These land surface estimates are based on land surface process models and, depending on the reanalysis product, on precipitation observations or the assimilation of land surface observations of soil moisture, soil temperature, snow conditions, and screen-level air temperature and humidity from satellite observations and in situ measurements. In this presentation, we review the land surface modeling and data assimilation components of the suite of current and planned MERRA reanalysis products. In addition to MERRA-2, we will discuss the latest NASA reanalysis, MERRA for the 21st century (M21C), which is currently under production, as well as the development and planning of the next version of the MERRA reanalysis, tentatively labeled MERRA-3. In MERRA-2, observations-based precipitation data products are used to correct the precipitation falling on the land surface. Outside of the high-latitudes and Africa, the daily, 0.5-degree, gauge-based Climate Prediction Center (CPC) Unified (CPCU) product is used. In Africa, the pentad, 2.5-degree, satellite- and gauge-based CPC Merged Analysis of Precipitation (CMAP) product is used. Poleward of 62.5 degrees latitude, the land surface sees the precipitation generated by the atmospheric model in the cycling data assimilation system. This configuration provides improved soil moisture estimates compared to those of the original (version 1) MERRA estimates, which did not benefit from the use of precipitation observations. Moreover, the use of precipitation observations facilitates a seamless spin-up of the land surface initial conditions across the MERRA-2 production streams. The use of a gauge-only precipitation product in MERRA-2 across much of the globe, however, adversely impacts the quality of the MERRA-2 land surface estimates in regions with poor gauge coverage, including most of South America and Australia. Therefore, the forthcoming M21C reanalysis uses satellite- and gauge-based precipitation from the Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement Mission (IMERG). This change results in significant improvements in the quality of the M21C soil moisture estimates in the Southern Hemisphere compared to those from MERRA-2. Planning for MERRA-3 focuses on the assimilation of soil moisture observations from the Soil Moisture Active Passive (SMAP) mission and the Advanced Scatterometer (ASCAT), along with snow cover area fraction observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) to further improve the quality of the land surface estimates from the reanalysis. As a first step towards the assimilation of land surface observations in MERRA-3, the offline (land-only) M21C-Land reanalysis is currently under development as a supplemental M21C product that includes the assimilation of SMAP, ASCAT, and MODIS observations. Preliminary results from M21C and M21C-Land will be discussed in the context of MERRA-2 and plans for MERRA-3.

Rolf Reichle↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Sodium Simulant Testing To Support SB8 Sludge Preparation

Scoping studies were completed for high sodium simulant SRAT/SME cycles to determine any impact to CPC processing. Two SRAT/SME cycles were performed with simulant having sodium supernate concentration of 1.9M at 130% and 100% of the Koopman Minimum Acid requirement. Both of these failed to meet DWPF processing objectives related to nitrite destruction and hydrogen generation. Another set of SRAT/SME cycles were performed with simulant having a sodium supernate concentration of 1.6M at 130%, 125%, 110%, and 100% of the Koopman Minimum Acid requirement. Only the run at 110% met DWPF processing objectives. Neither simulant had a stoichiometric factor window of 30% between nitrite destruction and excessive hydrogen generation. Based on the 2M-110 results it was anticipated that the 2.5M stoichiometric window for processing would likely be smaller than from 110-130%, since it appeared that it would be necessary to increase the KMA factor by at least 10% above the minimum calculated requirement to achieve nitrite destruction due to the high oxalate content. The 2.5M-130 run exceeded the DWPF hydrogen limits in both the SRAT and SME cycle. Therefore, testing of this wash endpoint was halted. This wash endpoint with this minimum acid requirement and mercury-noble metal concentration profile appears to be something DWPF should not process due to an overly narrow window of stoichiometry. The 2M case was potentially processable in DWPF, but modifications would likely be needed in DWPF such as occasionally accepting SRAT batches with undestroyed nitrite for further acid addition and reprocessing, running near the bottom of the as yet ill-defined window of allowable stoichiometric factors, potentially extending the SRAT cycle to burn off unreacted formic acid before transferring to the SME cycle, and eliminating formic acid additions in the frit slurry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗