Applications of the Minnesota impedance cardiograph
Impedance cardiograph for estimating cardiac output and related cardiovascular or pulmonary functions
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Impedance cardiograph for estimating cardiac output and related cardiovascular or pulmonary functions
Position dependent variations in intrapericardial, pleural and esophageal pressures and cardiac output in thorax of dogs
Hemodynamic effect of lidocaine given by infusion and bolus injections in myocardial infarction, examining cardiac output, heart rate, systolic left ventricular and aortic pressures
Hypoxia affecting circulatory responses in dogs, such as cardiac output, left ventricular dp/dt, and stroke volume
Isoproterenol, atrial pacing, ouabain and methoxamine effects on dogs during experimental cardiac tamponade, observing arterial pressure, cardiac output and heart rate changes
The deconditioning effects of weightlessness on the cardiovascular system of astronauts are discussed. It is believed that man cannot tolerate indefinite exposure to weightlessness without considerable circulatory deterioration. Analyses of data collected from space flights to date substantiate these beliefs, and confirm the fact that some form of compensation must be provided to keep the cardiovascular system of space travelers properly conditioned. Sequential pulsatile devices were investigated to produce periodic hydrostatic pressure gradients in the venous system of eight subhuman primates. Intermittent venous pooling of blood in the extremities triggers and stimulates the vascular reflex mechanisms of the cardiovascular system that may have significant benefits in maintaining the circulatory system in proper tone under weightless conditions. Electrocardiograms, blood pressure measurements, cardiac output and stroke volume determinations were used to evaluate the efficiency of the described technique. Results were amazingly consistent to indicate an efficient system for intermittently exercising the heart within safe and medically acceptable limits.
A system is presented which will reduce analog cardiac performance data and convert the results to digital form for direct entry into a commercial time-shared computer. Circuits are discussed which perform the measurement and digital conversion of instantaneous systolic and diastolic parameters from the analog blood pressure waveform. Digital averaging over a selected number of heart cycles is performed on these measurements, as well as those of flow and heart rate. The determination of average cardiac output and peripheral resistance, including trends, is the end result after processing by digital computer.
Results of a study in which six supine resting subjects, wearing water-perfused suits, had body skin temperature controlled at 35 C for 30 min (control period), then rapidly increased to 40.5 C for 43 to 50 min (heating period) in a two-part experiment. In the first part of the experiment arterial mean pressure (MP) in three men was increased back to, or above control levels at the 30 to 35th min of heating by total occlusion of both legs for 8 to 10 min. Splanchnic blood flow (SBF), which had fallen from 1.4 to 0.9 L/min at occlusion, rose only 0.05 L/min during occlusion. Splanchnic vascular resistance (SVR) rose throughout heating and occlusion. In the second part of the experiment (three men) SBF fell despite a spontaneous rise in MP and aortic pulse pressure prior to leg occlusion. Cardiac output (CO) was measured just before, during and after occlusion. Occlusion raised MP 10 to 15 mm Hg and reduced CO only slightly. It is concluded that falling MP or aortic pulse pressure are not major causes of the splanchnic vasoconstriction in response to heating man.
Three levels of decreased arterial oxygen saturation elicited a graded circulatory response in dogs, manifested by stepwise increases in cardiac output, left ventricular dp/dt, and stroke volume, and decreases in systemic vascular resistance. Responses to similar hypoxia challenges after experimental myocardial infarction were qualitatively similar but quantitatively less. Although the circulatory compensation for hypoxia was less effective after myocardial infarction, no further deterioration of the haemodynamics was noted.
Three-part experiment in which five subjects were exposed to lower body negative pressure (LBNP) at -50 mm Hg below the iliac crests. Duration of LBNP to earliest vagal symptoms was 7 to 21 min; all data are expressed as changes from control period to the last measurements before these symptoms. In part I, forearm blood flow (by Whitney gauge) fell 45% during LBNP. In part II, splanchnic blood flow (from arterial clearance hepatic extraction of indocyanine green) fell 32% and splanchnic vascular resistance rose 30%. In part III, cardiac output fell 28%, stroke volume 51%, and central blood volume 21%. Total peripheral resistance and heart rate rose 19% and 52%. Of the reduction in total vascular conductance, decreased splanchnic conductance accounted for approximately 33%; skin plus muscle conductance decreased similarly.
Changes in forearm muscle blood flow (FMBF) during direct whole-body heating were measured in 17 normal subjects using three different methods. We conclude that FMBF is not increased by direct whole-body heating. Since renal and splanchnic blood flow fall 30% under these conditions, maximal total skin blood flow in 12 previously studied subjects can be estimated from the rise in cardiac output to be 7.6 L/min (3.0-11.1 L/min).
The areas of physiological research reported include: (1) evaluation of the single-breath method for determining cardiac output, (2) optimum protocol for the assessment of cardio-pulmonary competence, (3) body fluids and electrolytes under conditions of single and combined stress, (4) re-evaluation of the open-circuit method for measuring metabolic rate with regard to the alleged metabolic production of gaseous nitrogen, and (5) the use of the forced-oscillation method to determine total respiratory conductance in healthy subjects and pulmonary patients.
This experiment was conducted to determine what physiological effects result when highly trained subjects are confined to bed, deprived of sleep, or allowed to discontinue training. Results indicated: (1) There was a moderate increase in strength variables due to the training in this experiment but the stress which the subjects received caused a negligible change in strength variables. (2) The training program resulted in highly significant changes in specific bicycle ergometer variables indicating good increases in cardiopulmonary fitness. Five days of bed rest or fifty hours of sleep deprivation caused comparable drastic decreases in cardiopulmonary fitness. Post stress the subjects reverted to a normal daily schedule and after two weeks they had recovered about half of what they lost. (3) Cardiac output remains relatively constant at a constant work load, but stroke volume increases with conditioning and decreases with deconditioning due to stress.
An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.
Following exposure to weightlessness, alterations in the return of blood from the legs play a crucial role in orthostatic tolerance and may be an important factor in work tolerance. To investigate some of the hemodynamic mechansism involved, an experiment was performed on the Skylab 3 and Skylab 4 missions to study arterial blood flow, venous compliance, and muscle pumping of blood. Skylab 4 results indicated that the most likely cause of increased blood flow was an increase in cardiac output secondary to increased central venous pressure caused by blood redistribution. Changes in venous compliance are thought to be primarily changes in somatic musculature which is postulated to primarily determine venous compliance of the legs. This was also thought to be demonstrated by the changes in muscle pumping. It is thought that these compliance changes, when taken with the decreased blood volume; provide a basis for the changes seen in orthostatic tolerance, work capacity and lower body negative pressure response.
Submaximal exercise stress tests were conducted preflight and postflight on the Apollo 14-17 crewmen. A bicycle ergometer was utilized to evoke target heart rates up to 160 beats/min while respiratory gas exchange, blood pressure, and cardiac output were measured. Three preflight tests were conducted during the month prior to flight to establish baseline values for postflight comparisons. Tachycardia was evidenced at rest and during exercise immediately postflight. This transitory tachycardia compensated for reduced stroke volume. Systolic blood pressure was reduced during exercise stress, but no consistent changes were observed in diastolic blood pressure. With the exception of the Apollo 15 crewmen, all crewmen had returned to preflight response levels by the day following recovery. No changes were observed in mechanical or respiratory efficiency immediately postflight.
The experiment was performed to ascertain whether man's ability to perform mechanical work would be altered as a result of exposure to the weightless environment. Skylab II crewmen were exercised on a bicycle ergometer at loads approximating 25%, 50%, and 75% of their maximum oxygen uptake while their physiological responses were monitored. The results of these tests indicate that the crewmen had no significant decrement in their response to exercise during their exposure to zero gravity. Immediately postflight, however, all crewmen demonstrated an inability to perform the programmed exercise with the same metabolic effectiveness as they did both preflight and inflight. The most significant changes were elevated heart rates for the same work load and oxygen consumption (decreased oxygen pulse), decreased stroke volume, and decreased cardiac output at the same oxygen consumption level. It is apparent that the changes occurred inflight, but did not manifest themselves until the crewmen attempted to readapt to the 1-G environment.
The purpose of the present study is to determine the effects of changes in posture on oxygen transfer at the mouth and pulmonary capillary membrane and to observe concomitant subtle changes in ventilation under specified assumptions. Breath-by-breath calculations are carried out with a box-balloon spirometer and mass spectrometer. Measurements are made before, during, and after passive tilt to 60 deg and on return to recumbency after 10 min erect. It is found that from supine to upright oxygen stores in the lung increases rapidly and oxygen stores in the blood drops slowly, creating a net deficit in oxygen transfer at the mouth of 130 ml in 10 min. Changes in oxygen stores in the blood result from shifts in blood volume and flow more than from changes in cardiac output. Refilling of oxygen stores in the blood is found to cause transient hypoxia with substantial hyperpnea.