Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cardiac flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Intrapericardial denervation: Responses to water immersion in rhesus monkeys

Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings. water immersion; natriuresis; vasopressin; eardiae denervation; monkey

McKeever, Kenneth H.↗

Intrapericardial Denervation: Responses to Water Immersion in Rhesus Monkeys

Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings.

McKeever, Kenneth H.↗

Hypocapnia and cerebral hypoperfusion in orthostatic intolerance

BACKGROUND AND PURPOSE: Orthostatic and other stresses trigger tachycardia associated with symptoms of tremulousness, shortness of breath, dizziness, blurred vision, and, often, syncope. It has been suggested that paradoxical cerebral vasoconstriction during head-up tilt might be present in patients with orthostatic intolerance. We chose to study middle cerebral artery (MCA) blood flow velocity (BFV) and cerebral vasoregulation during tilt in patients with orthostatic intolerance (OI). METHODS: Beat-to-beat BFV from the MCA, heart rate, CO2, blood pressure (BP), and respiration were measured in 30 patients with OI (25 women and 5 men; age range, 21 to 44 years; mean age, 31.3+/-1.2 years) and 17 control subjects (13 women and 4 men; age range, 20 to 41 years; mean age, 30+/-1.6 years); ages were not statistically different. These indices were monitored during supine rest and head-up tilt (HUT). We compared spontaneous breathing and hyperventilation and evaluated the effect of CO2 rebreathing in these 2 positions. RESULTS: The OI group had higher supine heart rates (P<0.001) and cardiac outputs (P<0.01) than the control group. In response to HUT, OI patients underwent a greater heart rate increment (P<0.001) and greater reductions in pulse pressure (P<0.01) and CO2 (P<0.001), but total systemic resistance failed to show an increment. Among the cerebrovascular indices, all BFVs (systolic, diastolic, and mean) decreased significantly more, and cerebrovascular resistance (CVR) was increased in OI patients (P<0.01) compared with control subjects. In both groups, hyperventilation induced mild tachycardia (P<0.001), a significant reduction of BFV, and a significant increase of CVR associated with a fall in CO2. Hyperventilation during HUT reproduced hypocapnia, BFV reduction, and tachycardia and worsened symptoms of OI; these symptoms and indices were improved within 2 minutes of CO2 rebreathing. The relationships between CO2 and BFV and heart rate were well described by linear regressions, and the slope was not different between control subjects and patients with OI. CONCLUSIONS: Cerebral vasoconstriction occurs in OI during orthostasis, which is primarily due to hyperventilation, causing significant hypocapnia. Hypocapnia and symptoms of orthostatic hypertension are reversible by CO2 rebreathing.

Non-NASA Center↗

Development of a model to assess orthostatic responses

A major change for crewmembers during weightlessness in microgravity is the redistribution of body fluids from the legs into the abdomen, thorax, and head. The fluids continue to be sequestered in these areas throughout the flight. Upon reentry into gravity on landing, these same body fluids are displaced again to their normal locations, however, not without hazardous incidence to the crewmembers. The problem remains that upon landing, crewmembers are subject to orthostasis, that is, the blood flowing into the legs reduces the blood supply to the brain and may result in the crewmember fainting. The purpose of this study was to develop a model of testing orthostatic responses of blood pressure regulating mechanisms of the cardiovascular system, when challenged, to maintain blood pressure to the brain. To accomplish this, subjects' responses were assessed as they proceeded from the supine position of progressive head-up tilt positions of 30 deg, 60 deg, and 90 deg angles. A convenience sample consisted of 21 subjects, females (N=11) and males (N=10), selected from a list of potential subjects available through the NASA subject screening office. The methodology included all non-invasive measurements of blood pressure, heart rate, echocardiograms, cardiac output, cardiac stroke volume, fluid shifts in the thorax, ventricular ejection and velocity times, and skin blood perfusion. The Fischer statistical analysis was done of all data with the significance level at .05. Significant differences were demonstrated in many instances of changes of posture for all variables. Based on the significance of the findings of this study, this model for assessing orthostatic responses does provide an adequate challenge to the blood pressure regulatory systems. While individuals may use different adaptations to incremental changes in gravity, the subjects, in aggregate, demonstrated significant adaptive cardiovascular changes to orthostatic challenges which were presented to them.

Rubin, Marilyn↗

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Molecular and functional analyses of the contractile apparatus in lymphatic muscle

Lymphatics are necessary for the generation and regulation of lymph flow. Lymphatics use phasic contractions and extrinsic compressions to generate flow; tonic contractions alter resistance. Lymphatic muscle exhibits important differences from typical vascular smooth muscle. In this study, the thoracic duct exhibited significant functional differences from mesenteric lymphatics. To understand the molecular basis for these differences, we examined the profiles of contractile proteins and their messages in mesenteric lymphatics, thoracic duct, and arterioles. Results demonstrated that mesenteric lymphatics express only SMB smooth muscle myosin heavy chain (SM-MHC), whereas thoracic duct and arterioles expressed both SMA and SMB isoforms. Both SM1 and SM2 isoforms of SM-MHC were detected in arterioles and mesenteric and thoracic lymphatics. In addition, the fetal cardiac/skeletal slow-twitch muscle-specific beta-MHC message was detected only in mesenteric lymphatics. All four actin messages, cardiac alpha-actin, vascular alpha-actin, enteric gamma-actin, and skeletal alpha-actin, were present in both mesenteric lymphatics and arterioles. However, in thoracic duct, predominantly cardiac alpha-actin and vascular alpha-actin were found. Western blot and immunohistochemical analyses corroborated the mRNA studies. However, in arterioles only vascular alpha-actin protein was detected. These data indicate that lymphatics display genotypic and phenotypic characteristics of vascular, cardiac, and visceral myocytes, which are needed to fulfill the unique roles of the lymphatic system.

Non-NASA Center↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.↗

Microwave Treatment for Cardiac Arrhythmias

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Transcatheter Antenna For Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

In Vivo Simulator for Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Beat-by-beat stroke volume assessment by pulsed Doppler in upright and supine exercise

The instantaneous stroke volume (SV) and cardiac output (Q) in eight male subjects during steady-state supine (S) and upright (U) exercises at 300 kpm/min is assessed by a 3.0-MHz pulsed Doppler echocardiograph. The mean transients in heart rate (HR), SV, and Q for each posture were determined and the center-line blood velocities obtained in the ascending aorta. Results show that the mean supine values for SV and Q at rest and exercise were 111 ml and 6.4 l/min and 112 ml and 9.7 l/min, respectively. The corresponding results for U were 76 ml and 5.6 l/min and 92 ml and 8.4 l/min, respectively. The values compare favorably with previous studies utilizing invasive procedures. The transient response of Q following the onset of exercise in U was about twice as fast as in S because of the rapid and almost immediate upsurge in SV. The faster rise in aortic flow in U with exercise represented and additional volume (184 ml) of blood passing through the aorta compared with S in the first 20 exercises. It is suggested that the rapid mobilization of pooled venous blood from the leg veins during U was responsible for the increased blood flow.

Loeppky, J. A.↗

Pulmonary function in microgravity: KC-135 experience

We have commenced a KC-135 program that parallels and proceeds our Spacelab (SLS-1) pulmonary function experiment. Our first task was to elucidate the affect of normal gravitation on the shape of the maximum expiratory flow volume (MEFV) curve. Nine normal subjects performed multiple MEFV maneuvers at 0-G, 1-G, and approximately 1.7-G. The MEFV curves for each subject were filtered, aligned at RV, and ensemble-averaged to produce an average MEFV curve for each state, allowing differences to be studied. Most subjects showed a decrease in the FVC at 0-G, which we attribute to an increased intrathoracic blood volume. In most of these subjects, the mean lung volume associated with a given flow was lower at 0-G, over about the upper half of the vital capacity. This is similar to the change previously reported during heat out immersion and is consistent with the known affect of engorgement of the lung with blood, on elastic recoil. There were also consistent but highly individual changes in the position and magnitude of detailed features of the curve, the individual patterns being similar to those previously reported on transition from the erect to the supine position. This supports the idea that the location and motion of choke points which determine the detailed individual configuration of MEFV curves, can be significantly influenced by gravitational forces, presumably via the effects of change in longitudinal tension on local airway pressure-diameter behavior and wave speed. We have developed a flight mass spectrometer and have commenced a study of single breath gradients in gas exchange, inert gas washouts, and rebreathing cardiac outputs and lung volumes at 0-G, 1-G, and 1.7-G. Comparison of our results with those from SLS-1 should identify the opportunities and limitations of the KC-135 as an accessible microgravity resource.

Guy, Harold J.↗

Influence of Exercise Modality on Cerebral-Ocular Hemodynamics and Pressures

Background: Moderate and high intensity aerobic or resistance exercise has clearly identified benefits for cardiac, muscle, and bone health. However, the impact of such exercise - either as a mitigating or an exacerbating factor - on the development of the visual impairment and intracranial pressure syndrome (VIIP) is unknown. Accordingly, our aim was to characterize the effect of an acute bout of resistance (RE), moderate-intensity continuous (CE), and high-intensity interval exercise (IE) during a cephalad fluid shift on cerebral-ocular hemodynamics and pressures. Methods: 10 male subjects (36 plus or minus 9 years) completed 4 testing days in a 15 degree head-down tilt (HDT): (1) assessment of maximum volume of O (sub 2), (2) RE session (4 sets of 12 repetition maximum leg press exercise), (3) CE session (30 minutes of cycling at 60 percent maximum volume of O (sub 2)), and (4) IE session (4 by 4-minute intervals of exercise at 85 percent maximum volume of O (sub 2) with 3-minute active rest periods). During each session, blood flow (Vivid-e, GE Healthcare) in extracranial arteries (common carotid artery, CCA; internal carotid artery, ICA; external carotid artery, ECA and vertebral artery, VA), and mean blood flow velocity in middle cerebral artery (MCA), internal jugular pressure (IJP; VeinPress), and intraocular pressure (IOP; Icare PRO) were measured at rest, at the end of each resistance or interval set, and every 5 minutes during continuous exercise. Translaminar pressure gradient (TLPG) was estimated by subtracting IJP from IOP. Results: There were no differences across days in pre-exercise resting blood flows or pressures. IOP decreased slightly from HDT rest (20.2 plus or minus 2.3 millimeters of mercury) to exercise (RE: 19.2 plus or minus 2.8 millimeters of mercury; CE: 18.9 plus or minus 3.2 millimeters of mercury; IE: 20.1 plus or minus 2.8 millimeters of mercury), while IJP decreased during CE (31.6 plus or minus 9.5 millimeters of mercury) and RE (32.0 plus or minus 8.1 millimeters of mercury), and increased during IE (35.1 plus or minus 9.5 millimeters of mercury) from HDT rest (33.3 plus or minus 6.5 millimeters of mercury). Estimated TLPG was increased during IE only. Compared to RE and CE, IE resulted in the greatest increase in MCA blood flow velocity and extracranial artery blood flow. Conclusions: These preliminary results suggest that high-intensity IE acutely increases cerebral blood flow, IJP, and TLPG. Alterations in TLPG is one mechanism that may contribute to optic nerve sheath edema in astronauts. Accordingly, acutely raising IOP and/or orbital pressure during exercise could optimize cerebral-ocular pressures during spaceflight.

Scott, J.↗

Rodent Research on the International Space Station - A Look Forward

Rodent Research on the International Space Station (ISS) is one of the highest priority science activities being supported by NASA and is planned for up to two flights per year. The first Rodent Research flight, Rodent Research-1 (RR-1) validates the hardware and basic science operations (dissections and tissue preservation). Subsequent flights will add new capabilities to support rodent research on the ISS. RR-1 will validate the following capabilities: animal husbandry for up to 30 days, video downlink to support animal health checks and scientific analysis, on-orbit dissections, sample preservation in RNA. Later and formalin, sample transfer from formalin to ethanol (hindlimbs), rapid cool-down and subsequent freezing at -80 of tissues and carcasses, sample return and recovery. RR-2, scheduled for SpX-6 (Winter 20142015) will add the following capabilities: animal husbandry for up to 60 days, RFID chip reader for individual animal identification, water refill and food replenishment, anesthesia and recovery, bone densitometry, blood collection (via cardiac puncture), blood separation via centrifugation, soft tissue fixation in formalin with transfer to ethanol, and delivery of injectable drugs that require frozen storage prior to use. Additional capabilities are also planned for future flights and these include but are not limited to male mice, live animal return, and the development of experiment unique equipment to support science requirements for principal investigators that are selected for flight. In addition to the hardware capabilities to support rodent research the Crew Office has implemented a training program in generic rodent skills for all USOS crew members during their pre-assignment training rotation. This class includes training in general animal handling, euthanasia, injections, and dissections. The dissection portion of this training focuses on the dissection of the spleen, liver, kidney with adrenals, brain, eyes, and hindlimbs. By achieving and maintaining proficiency in these basic skills as part of the nominal astronaut training curriculum this allows the rodent research program to focus the mission specific crew training on scientific requirements of research and operations flow.

Experimental capabilities↗

Infrascope: Full-Spectrum Phonocardiography With Automated Signal Analysis Report

Physicians have used the stethoscope to listen to heart sounds for over 150 years. During this time the stethoscope has remained nearly unchanged. While the device is inexpensive, simple and easy to use, it has shortcomings as a diagnostic tool. It is dependent on human hearing to detect the complex sounds made by the heart, and human memory to analyze them. There also has been a significant decline in the use of stethoscope, at least in part because of the availability of technologies such as the echocardiogram, which can provide imaging and blood flow through the heart chambers. However, echocardiography can be complex, costly and time consuming and requires the need for a specialist, all of which delay the diagnosis and increase the cost of patient evaluation. Even with the availability of echocardiogram devices such as the handheld pocket ultrasound, diagnosing heart problems can still be difficult. The Infrascope is a new device that resembles a traditional stethoscope and is simple to use. In addition, the Infrascope offers greater sensitivity and a wider range of frequencies heard by the human ear, <20Hz than a traditional stethoscope can detect. Through automated analysis of the full spectrum of heart sounds, it has the potential to improve diagnostic accuracy while reducing the need for referrals, allowing primary care physicians to practice better medicine at the bedside.

Infrasounds↗

Cardiovascular function following reduced aerobic activity

PURPOSE: The aim of this study was to test the hypothesis that a sustained reduction of physical activity (deconditioning) would alter the cardiovascular regulatory function. METHODS: Nineteen young, healthy volunteers participated in physical deconditioning for a period of 8 wk. Before (pre) and following (post) physical deconditioning, the responses of heart rate (HR), mean arterial pressure (MAP, measured by Finapres), central venous pressure (CVP), stroke volume (SV, Doppler), and forearm blood flow (FBF, plethysmography) were determined during lower body negative pressure (LBNP). The carotid baroreflex (CBR) function was assessed using a train of pulsatile neck pressure (NP) and suction, and the aortic baroreflex control of HR was assessed during steady-state phenylephrine (PE) infusion superimposed by LBNP and NP to counteract the PE increased CVP and carotid sinus pressure, respectively. RESULTS: Active physical deconditioning significantly decreased maximal oxygen uptake (-7%) and LBNP tolerance (-13%) without a change in baseline hemodynamics. Plasma volume (-3% at P = 0.135), determined by Evans Blue dilution, and blood volume (-4% at P = 0.107) were not significantly altered. During LBNP -20 to -50 torr, there was a significantly greater drop of SV per unit decrease in CVP in the post- (14.7 +/- 1.6%/mm Hg) than predeconditioning (11.2 +/- 0.7%/mm Hg) test accompanied by a greater tachycardia. Deconditioning increased the aortic baroreflex sensitivity (pre vs post: -0.61 +/- 0.12 vs -0.84 +/- 0.14 bpm.mm-1 Hg, P = 0.009) and the slope of forearm vascular resistance (calculated from [MAP-CVP]/FBF) to CVP (-2.75 +/- 0.26 vs -4.94 +/- 0.97 PRU/mm Hg, P = 0.086). However, neither the CBR-HR (-0.28 +/- 0.03 VS -0.39 +/- 0.10 bpm.mm-1 Hg) nor the CBR-MAP (-0.37 +/- 0.16 vs -0.25 +/- 0.07 mm Hg/mm Hg) gains were statistically different between pre- and postdeconditioning. CONCLUSIONS: We concluded that the functional modification of the cardiac pressure-volume relationship resulted in the reduced LBNP tolerance, despite the accentuated aortic and cardiopulmonary baroreflex function following deconditioning.

Non-NASA Center↗

Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60 degrees head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt(cool)), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt(cool)). Heating and cooling were accomplished by perfusing 46 and 15 degrees C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt(cool), or HT-tilt(cool). During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt(cool), MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

Clinical Trial↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗