Search NASA⌕ Search

SEARCH · Search NASA

Results for “Centrifugal compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of the Seeding System Used for Laser Velocimeter Surveys of the NASA Low-Speed Centrifugal Compressor Flow Field

Consideration is given to an atomizer-based system for distributing high-volume rates of polystyrene latex (PSL) seed material developed to support laser velocimeter investigations of the NASA Low-Speed Compressor flow field. Complete evaporation of the liquid carrier before the flow entering the compressor was of primary concern for the seeder system design. It is argued that the seed nozzle should incorporate a needle valve that can mechanically dislodge accumulated PSL seed material when the nozzle is turned off. Water is less expensive as the liquid carrier and should be used whenever adequate residence times are available to ensure complete evaporation. PSL agglomerates over time and needs to be mixed or blended before use. Arrangement of the spray nozzles needs to be adjustable to provide maximum seeding at the laser probe volume.

Wasserbauer, C. A.↗

On the Automatic Regulation of Output in Centrifugal Compressors

This paper discussed the theory and design of dynamic "pressure augmentors" (diaphragms equal orifice plates and nozzles) and various forms of "pressure multipliers" (simple venturi tubes, Rateau-type multiple venturis, and a combination of shaped nozzle and simple venturi developed by the author). No complete theory of pressure multiplication is yet available; conditions of governing are discussed in relation to pressure-augmenting devices fitted either on the suction or the pressure side of the blower; fluctuations of output and power consumption caused by the presence of an augmentor are analyzed with the result that fitting on the pressure side appears generally preferable. Some considerations on the suitable design and selection of pressure-augmenting devices are appended.

Ris, V. F.↗

Surge Flow in a Centrifugal Compressor Measured by Digital Particle Image Velocimetry

A planar optical velocity measurement technique known as Particle Image Velocimetry (PIV) is being used to study transient events in compressors. In PIV, a pulsed laser light sheet is used to record the positions of particles entrained in a fluid at two instances in time across a planar region of the flow. Determining the recorded particle displacement between exposures yields an instantaneous velocity vector map across the illuminated plane. Detailed flow mappings obtained using PIV in high-speed rotating turbomachinery components are used to improve the accuracy of computational fluid dynamics (CFD) simulations, which in turn, are used to guide advances in state-of-the-art aircraft engine hardware designs.

Wernet, Mark P.↗

Centrifugal Compressor Surge Controlled

It shows the variation in compressor mass flow with time as the mass flow is throttled to drive the compressor into surge. Surge begins where wide variations in mass flow occur. Air injection is then turned on to bring about a recovery from the initial surge condition and stabilize the compressor. The throttle is closed further until surge is again initiated. Air injection is increased to again recover from the surge condition and stabilize the compressor.

Skoch, Gary J.↗

Method of construction for internally cooled diaphragms for centrifugal compressor

An internally-cooled compressor is provided including a casing and a diaphragm disposed in the casing. The diaphragm includes a diaphragm box defining a plurality of box channels and a bulb defining a plurality of bulb channels. A plurality of return channel vanes connect the diaphragm box and bulb in fluid communication, such that each return channel vane defines a plurality of return vane conduits coupled in fluid communication with the plurality of box channels and the plurality of bulb channels thereby forming a section of a cooling pathway. The cooling pathway is configured such that a cooling agent introduced from an external coolant source into the diaphragm box and flowing through a box channel flows through a return vane conduit into and through a bulb channel and back through another return vane conduit into another box channel before flowing back to the external coolant source.

42 ENGINEERING↗

Overview of CFD validation experiments

The topics are presented in viewgraph form and include the following: fundamental physics validation experiments; applied physics validation experiments; physical flow phenomena; boundary layer tunnel; boundary layer research; centrifugal compressors; centrifugal compressor flow phenomena; turbomachinery computational fluid dynamics (CFD) validation; inlet, duct, and nozzle CFD validation; and chemical reacting flows CFD validation.

Povinelli, Louis A.↗

Centrifugal-reciprocating compressor

A centrifugal compressor is described which includes at least one pair of cylinders arranged in coaxial alignment and supported for angular displacement about a common axis of rotation normally disecting a common longitudinal axis of symmetry for the cylinders. The cylinders are characterized by ported closures located at the mutually remote ends thereof through which the cylinders are charged and discharged, and a pair of piston heads seated within the cylinders and supported for floating displacement in compressive strokes in response to unidirectional angular displacement imparted to the cylinders.

Higa, W. H.↗

Centrifugal reciprocating compressor

Efficient compressor uses centrifugal force to compress gas. System incorporates two coupled dc motors, each driving separate centrifugal reciprocating-compressor assembly. Motors are synchronized to accelerate and decelerate alternately.

High, W. H.↗

Impeller flow field measurement and analysis

A series of experiments are performed to investigate and quantify the three-dimensional mean flow field in centrifugal compressor flow passages and to evaluate contemporary internal flow models. The experiments include the acquisition and analysis of LDV data in the impeller passages of a low-speed moderate-scale research mixed-flow centrifugal compressor operating at its design point. Predictions from a viscous internal flow model are then correlated with these data. The LDV data show the traditional jet-wake structure observed in many centrifugal compressors, with the wake observed along the shroud 70 percent of the length from the pressure to suction surface. The viscous model predicts the major flow phenomena. However, the correlations of the viscous predictions with the LDV data were poor.

Fagan, J. R.↗

Application of Digital Particle Imaging Velocimetry to Turbomachinery

Digital Particle Imaging Velocimetry (DPIV) is a powerful measurement technique, which can be used as an alternative or complementary approach to Laser Doppler Velocimetry (LDV) in a wide range of research applications. The instantaneous planar velocity measurements obtained with PIV make it an attractive technique for use in the study of the complex flow fields encountered in turbomachinery. Many of the same issues encountered in the application of LDV to rotating machinery apply in the application of PIV. Techniques for optical access, light sheet delivery, CCD camera technology and particulate seeding are discussed. Results from the successful application of the PIV technique to both the blade passage region of a transonic axial compressor and the diffuser region of a high speed centrifugal compressor are presented. Both instantaneous and time-averaged flow fields were obtained. The 95% confidence intervals for the time-averaged velocity estimates were also determined. Results from the use of PIV to study surge in a centrifugal compressor are discussed. In addition, combined correlation/particle tracking results yielding super-resolution velocity measurements are presented.

Wernet, Mark P.↗

Active magnetic bearings applied to industrial compressors

The design and shop test results are given for a high-speed eight-stage centrifugal compressor supported by active magnetic bearings. A brief summary of the basic operation of active magnetic bearings and the required rotor dynamics analysis are presented with specific attention given to design considerations for optimum rotor stability. The concerns for retrofits of magnetic bearings in existing machinery are discussed with supporting analysis of a four-stage centrifugal compressor. The current status of industrial machinery in North America using this new support system is presented and recommendations are given on design and analysis requirements for successful machinery operation of either retrofit or new design turbomachinery.

Kirk, R. G.↗

NASA HECC Geometry and Performance Review Part 3: A Numerical and Experimental Investigation of Tip Clearance Effects on the Vaneless Diffuser Configuration

Tip clearance effects in centrifugal compressors have been extensively investigated to understand the losses associated with the flow in the impeller tip clearance gap between the rotating blades and the stationary shroud. In Part 3 of this multipart investigation, experimental data and validated numerical simulations from Parts 1 and 2 were used to analyze the effects of the size of the tip clearance gap on the High Efficiency Centrifugal Compressor performance and aerodynamics. Four tip clearance gaps ranging from 0.012-in to 0.030-in (2.0% to 4.9% of the impeller exit blade height) were considered at both design and off-design operating conditions. The total pressure ratio and efficiency of the stage are found to decay linearly with increasing tip gaps. The sensitivity of the impeller performance to the tip gap was found to vary with the rotational speed of the compressor. Spanwise surveys of flow angle, total pressure, and total temperature collected at the impeller exit at design speed are used to validate numerical simulations at each experimental tip gap condition. Numerical simulations show that increased turbulence kinetic energy near the shroud at larger tip gaps leads to spanwise mixing of high entropy fluid near the impeller trailing edge which decreases the useful work input by the impeller. The data presented have been made available to the public in the HECC Data Archive located at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA HECC Geometry and Performance Review Part 3: A Numerical and Experimental Investigation of Tip Clearance Effects on the Vaneless Diffuser Configuration

Tip clearance effects in centrifugal compressors have been extensively investigated to understand the losses associated with the flow in the impeller tip clearance gap between the rotating blades and the stationary shroud. In Part 3 of this multipart investigation, experimental data and validated numerical simulations from Parts 1 and 2 were used to analyze the effects of the size of the tip clearance gap on the High Efficiency Centrifugal Compressor performance and aerodynamics. Four tip clearance gaps ranging from 0.012-in to 0.030-in (2.0% to 4.9% of the impeller exit blade height) were considered at both design and off-design operating conditions. The total pressure ratio and efficiency of the stage are found to decay linearly with increasing tip gaps. The sensitivity of the impeller performance to the tip gap was found to vary with the rotational speed of the compressor. Spanwise surveys of flow angle, total pressure, and total temperature collected at the impeller exit at design speed are used to validate numerical simulations at each experimental tip gap condition. Numerical simulations show that increased turbulence kinetic energy near the shroud at larger tip gaps leads to spanwise mixing of high entropy fluid near the impeller trailing edge which decreases the useful work input by the impeller. The data presented have been made available to the public in the HECC Data Archive located at https://storage.googleapis.com/hecc-data/NASA-HECC-Data-Archive.zip.

centrifugal compressor↗

NASA HECC Geometry and Performance Review Part 1: Validation of a Computational Model for the Vaneless Diffuser Configuration with As-Manufactured Impeller Geometry

An investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. This multipart investigation focused on validating the computational model against experimental data. The validated model was then used to explore the effects of observed geometric differences between the as-manufactured and design-intent impellers. Lastly, the validated model was used for comparison against an experimental tip clearance study. Details regarding each of the parts are detailed below: A multipart investigation of the NASA High Efficiency Centrifugal Compressor (HECC) vaneless diffuser configuration was performed. Part I of the investigation focused on describing the HECC vaneless computational model and its validation against the experimental data published in GT2023-103128. To generate the model, a verification of the manufactured impeller was performed and was confirmed to match the impeller CAD. Section data from the impeller CAD, referred to as As-Manufactured, were used in the model. Steady RANS simulations using a multiblock structured mesh were used to conduct a mesh convergence study. The resultant mesh was then used for simulations at both design-speed and off-design speed conditions. The simulations compared well to data in both 1D and 2D terms. Based on the observed results the model was deemed validated and was used in the latter two parts of the multipart investigation.

centrifugal compressor↗

Computational Study of the CC3 Impeller and Vaneless Diffuser Experiment

Centrifugal compressors are compatible with the low exit corrected flows found in the high pressure compressor of turboshaft engines and may play an increasing role in turbofan engines as engine overall pressure ratios increase. Centrifugal compressor stages are difficult to model accurately with RANS CFD solvers. A computational study of the CC3 centrifugal impeller in its vaneless diffuser configuration was undertaken as part of an effort to understand potential causes of RANS CFD mis-prediction in these types of geometries. Three steady, periodic cases of the impeller and diffuser were modeled using the TURBO Parallel Version 4 code: 1) a k-epsilon turbulence model computation on a 6.8 million point grid using wall functions, 2) a k-epsilon turbulence model computation on a 14 million point grid integrating to the wall, and 3) a k-omega turbulence model computation on the 14 million point grid integrating to the wall. It was found that all three cases compared favorably to data from inlet to impeller trailing edge, but the k-epsilon and k-omega computations had disparate results beyond the trailing edge and into the vaneless diffuser. A large region of reversed flow was observed in the k-epsilon computations which extended from 70% to 100% span at the exit rating plane, whereas the k-omega computation had reversed flow from 95% to 100% span. Compared to experimental data at near-peak-efficiency, the reversed flow region in the k-epsilon case resulted in an under-prediction in adiabatic efficiency of 8.3 points, whereas the k-omega case was 1.2 points lower in efficiency.

Kulkarni, Sameer↗

Computational Study of the CC3 Impeller and Vaneless Diffuser Experiment

Centrifugal compressors are compatible with the low exit corrected flows found in the high pressure compressor of turboshaft engines and may play an increasing role in turbofan engines as engine overall pressure ratios increase. Centrifugal compressor stages are difficult to model accurately with RANS CFD solvers. A computational study of the CC3 centrifugal impeller in its vaneless diffuser configuration was undertaken as part of an effort to understand potential causes of RANS CFD mis-prediction in these types of geometries. Three steady, periodic cases of the impeller and diffuser were modeled using the TURBO Parallel Version 4 code: (1) a k-ε turbulence model computation on a 6.8 million point grid using wall functions, (2) a k-ε turbulence model computation on a 14 million point grid integrating to the wall, and (3) a k-ω turbulence model computation on the 14 million point grid integrating to the wall. It was found that all three cases compared favorably to data from inlet to impeller trailing edge, but the k-ε and k-ω computations had disparate results beyond the trailing edge and into the vaneless diffuser. A large region of reversed flow was observed in the k-ε computations which extended from 70 to 100 percent span at the exit rating plane, whereas the k-ω computation had reversed flow from 95 to 100 percent span. Compared to experimental data at near-peak-efficiency, the reversed flow region in the k-ε case resulted in an underprediction in adiabatic efficiency of 8.3 points, whereas the k-ω case was 1.2 points lower in efficiency.

Kulkarni, Sameer↗

Extended parametric representation of compressor fans and turbines. Volume 3: MODFAN user's manual (parametric modulating flow fan)

A modeling technique for single stage flow modulating fans or centrifugal compressors has been developed which will enable the user to obtain consistent and rapid off-design performnce from design point input. The fan flow modulation may be obtained by either a VIGV (variable inlet guide vane) or a VPF (variable pitch rotor) option. Only the VIGV option is available for the centrifugal compressor. The modeling technique has been incorporated into a time-sharing program to facilitate its use. Because this report contains a description of the input output data, values of typical inputs, and examples cases, it is suitable as a user's manual. This report is the last of a three volume set describing the parametric representation of compressor fans, and turbines. The titles of the three volumes are as follows: (1) Volume 1 CMGEN USER's Manual (Parametric Compressor Generator); (2) Volume 2 PART USER's Manual (Parametric Turbine); (3) Volume 3 MODFAN USER's Manual (Parametric Modulating Flow Fan).

Converse, G. L.↗