Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cleaned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effect of cleaning procedures on the electrical properties of carbon nanotube transistors—A statistical study

The interface between a carbon nanotube (CNT) and its environment can dramatically affect the electrical properties of CNT-based field-effect transistors (FETs). For such devices, the channel environment plays a significant role inducing doping or charge traps giving rise to hysteresis in the transistor characteristics. Thereby the fabrication process strongly determines the extent of those effects and the final device performance. In CNT-based devices obtained from dispersions, a proper individualization of the nanotubes is mandatory. This is generally realized by an ultrasonic treatment combined with surfactant molecules, which enwrap nanotubes forming micelle aggregates. To minimize impact on device performance, it is of vital importance to consider post-deposition treatments for removal of surfactant molecules and other impurities. In this context, we investigated the effect of several wet chemical cleaning and thermal post treatments on the electrical characteristics as well as physical properties of more than 600 devices fabricated only by wafer-level compatible technologies. We observed that nitric acid and water treatments improved the maximum-current of devices. Additionally, we found that the ethanol treatment successfully lowered hysteresis in the transfer characteristics. The effect of the chemical cleaning procedures was found to be more significant on CNT-metal contacts than for the FET channels. Moreover, we investigated the effect of an additional thermal cleaning step under vacuum after the chemical cleaning, which had an exceptional impact on the hysteresis behavior including hysteresis reversal. The presence of surfactant molecules on CNT was evidenced by X-ray photoelectron and Raman spectroscopies. By identifying the role of surfactant molecules and assessing the enhancement of device performance as a direct consequence of several cleaning procedures, these results are important for the development of CNT-based electronics at the wafer-level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chemical Effect of Dry and Wet Cleaning of the Ru Protective Layer of the Extreme ultraviolet (EUV) Lithography Reflector

The authors report the chemical influence of cleaning of the Ru capping layer on the extreme ultraviolet (EUV) reflector surface. The cleaning of EUV reflector to remove the contamination particles has two requirements: to prevent corrosion and etching of the reflector surface and to maintain the reflectivity functionality of the reflector after the corrosive cleaning processes. Two main approaches for EUV reflector cleaning, wet chemical treatments [sulfuric acid and hydrogen peroxide mixture (SPM), ozonated water, and ozonated hydrogen peroxide] and dry cleaning (oxygen plasma and UV/ozone treatment), were tested. The changes in surface morphology and roughness were characterized using scanning electron microscopy and atomic force microscopy, while the surface etching and change of oxidation states were probed with x-ray photoelectron spectroscopy. Significant surface oxidation of the Ru capping layer was observed after oxygen plasma and UV/ozone treatment, while the oxidation is unnoticeable after SPM treatment. Based on these surface studies, the authors found that SPM treatment exhibits the minimal corrosive interactions with Ru capping layer. They address the molecular mechanism of corrosive gas and liquid-phase chemical interaction with the surface of Ru capping layer on the EUV reflector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Damage by radicals and photons during plasma cleaning of porous low-k SiOCH. II. Water uptake and change in dielectric constant

Porous dielectric materials provide lower capacitances that reduce RC time delays in integrated circuits. Typical low-k materials include porous SiOCH-silicon dioxide with carbon groups, principally CH{sub 3}, lining the pores. With a high porosity, internally connected pores provide pathways for reactive species to enter into the material. Fluorocarbon plasmas are often used to etch SiOCH, a process that leaves a fluorocarbon polymer on the surface that must later be removed. During cleaning using Ar/O{sub 2} or He/H{sub 2} plasmas, reactions of radicals that diffuse into the SiOCH and photons that penetrate into the SiOCH can remove -CH{sub 3} groups. Due to its higher reactivity, cleaning with Ar/O{sub 2} plasmas removes more -CH{sub 3} groups than He/H{sub 2} plasmas, and so produce more free radical sites, such as -SiO{sub 2} Bullet (a -SiO{sub 2}-CH{sub 3} site with the -CH{sub 3} group removed).Upon exposure to humid air, these free radical sites can chemisorb H{sub 2}O to form hydrophilic Si-OH which can further physisorb H{sub 2}O through hydrogen bonding to form Si-OH(H{sub 2}O). With the high dielectric constant of water, even a small percentage of water uptake can significantly increase the effective dielectric constant of SiOCH. In this paper, we report on results from a computational investigation of the cleaning of SiOCH using Ar/O{sub 2} or He/H{sub 2} plasmas and subsequent exposure to humid air. The authors found that plasma cleaning with He/H{sub 2} mixtures produce less demethylation than cleaning with Ar/O{sub 2} plasmas, as so results in less water uptake, and a smaller increase in dielectric constant. The water that produces the increase in dielectric constant is roughly half chemisorbed and half physisorbed, the latter of which can be removed with mild heating. Sealing the pores with NH{sub 3} plasma treatment reduces water uptake and helps prevent the increase in dielectric constant.

36 MATERIALS SCIENCE↗

Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications

The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperatures as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.

36 MATERIALS SCIENCE↗

Combined wet and dry cleaning of SiGe(001)

Combined wet and dry cleaning via hydrofluoric acid (HF) and atomic hydrogen on Si{sub 0.6}Ge{sub 0.4}(001) surface was studied at the atomic level using ultrahigh vacuum scanning tunneling microscopy (STM), scanning tunneling spectroscopy (STS), and x-ray photoelectron spectroscopy to understand the chemical transformations of the surface. Aqueous HF removes native oxide, but residual carbon and oxygen are still observed on Si{sub 0.6}Ge{sub 0.4}(001) due to hydrocarbon contamination from post HF exposure to ambient. The oxygen contamination can be eliminated by shielding the sample from ambient via covering the sample in the HF cleaning solution until the sample is introduced to the vacuum chamber or by transferring the sample in an inert environment; however, both processes still leave carbon contaminant. Dry in-situ atomic hydrogen cleaning above 330 °C removes the carbon contamination on the surface consistent with a thermally activated atomic hydrogen reaction with surface hydrocarbon. A postdeposition anneal at 550 °C induces formation of an atomically flat and ordered SiGe surface observed by STM. STS verifies that the wet and dry cleaned surface has an unpinned Fermi level with no states between the conduction and valence band edge comparable to sputter cleaned SiGe surfaces.

36 MATERIALS SCIENCE↗

Chalkboard 2 - How to Make Clean Hydrogen

Clean hydrogen is a carbon-free energy carrier that can be produced from water and sustainable energy sources such as wind, solar, and nuclear. Therefore, clean hydrogen is one of the best ways to not only decarbonize the energy supply system, but also address the zero-emission challenges specific to large-carbon emitting industries that are difficult to separate from fossil fuels. To help achieve the Biden Administration's goal of a 100% clean energy economy and net-zero emissions by 2050, several tens of millions of metric tons of clean, low-cost hydrogen will be needed annually. The HydroGEN Advanced Water Splitting Materials (AWSM) Consortium was established in 2016 as part of the Energy Materials Network (EMN) under the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Hydrogen and Fuel Cell Technologies Office to enhance the performance, improve the durability, and reduce the cost of clean hydrogen production technologies, and it is helping to advance the H2@Scale vision.

08 HYDROGEN↗

Oxalate Mass Balance During Chemical Cleaning in Tank 5F

The Savannah River Site (SRS) is preparing Tank 5F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning to determine whether the tank is ready for closure. SRS personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. Analysis of the anions showed the measured oxalate removed from Tank 5F to be approximately 50% of the amount added in the oxalic acid. To close the oxalate mass balance, the author collected solid samples, leached them with nitric acid, and measured the concentration of cations and anions in the leachate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OXALATE MASS BALANCE DURING CHEMICAL CLEANING IN TANK 6F

The Savannah River Remediation (SRR) is preparing Tank 6F for closure. The first step in preparing the tank for closure is mechanical sludge removal. Following mechanical sludge removal, SRS performed chemical cleaning with oxalic acid to remove the sludge heel. Personnel are currently assessing the effectiveness of the chemical cleaning to determine whether the tank is ready for closure. SRR personnel collected liquid samples during chemical cleaning and submitted them to Savannah River National Laboratory (SRNL) for analysis. Following chemical cleaning, they collected a solid sample (also known as 'process sample') and submitted it to SRNL for analysis. The authors analyzed these samples to assess the effectiveness of the chemical cleaning process. Analysis of the anions showed the measured oxalate removed from Tank 6F to be approximately 50% of the amount added in the oxalic acid. To close the oxalate mass balance, the author collected solid samples, leached them with nitric acid, and measured the concentration of cations and anions in the leachate. Some conclusions from this work are: (1) Approximately 65% of the oxalate added as oxalic acid was removed with the decanted liquid. (2) Approximately 1% of the oxalate (added to the tank as oxalic acid) formed precipitates with compounds such as nickel, manganese, sodium, and iron (II), and was dissolved with nitric acid. (3) As much as 30% of the oxalate may have decomposed forming carbon dioxide. The balance does not fully account for all the oxalate added. The offset represents the combined uncertainty in the analyses and sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Zones Study: A Comprehensive Web-Based Mapping Tool to Identify and Analyze Clean Energy Zones in the Eastern Interconnection

This report describes the work conducted in support of the Eastern Interconnection States’ Planning Council (EISPC) Energy Zones Study and the development of the Energy Zones Mapping Tool performed by a team of experts from three National Laboratories. The multi-laboratory effort was led by Argonne National Laboratory (Argonne), in collaboration with the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). In June 2009, the U.S. Department of Energy (DOE) and the National Energy Technology Laboratory published Funding Opportunity Announcement FOA-0000068, which invited applications for interconnection-level analysis and planning. In December 2009, the Eastern Interconnection Planning Collaborative (EIPC) and the EISPC were selected as two award recipients for the Eastern Interconnection. Subsequently, in 2010, DOE issued Research Call RC-BM-2010 to DOE’s Federal Laboratories to provide research support and assistance to FOA-0000068 awardees on a variety of key subjects. Argonne was selected as the lead laboratory to provide support to EISPC in developing a methodology and a mapping tool for identifying potential clean energy zones in the Eastern Interconnection. In developing the EISPC Energy Zones Mapping Tool (EZ Mapping Tool), Argonne, NREL, and ORNL closely collaborated with the EISPC Energy Zones Work Group which coordinated the work on the Energy Zones Study. The main product of the Energy Zones Study is the EZ Mapping Tool, which is a web-based decision support system that allows users to locate areas with high suitability for clean power generation in the U.S. portion of the Eastern Interconnection. The mapping tool includes 9 clean (low- or no-carbon) energy resource categories and 29 types of clean energy technologies. The EZ Mapping Tool contains an extensive geographic information system database and allows the user to apply a flexible modeling approach for the identification and analysis of potential energy zones and is publicly available at http://eispctools.anl.gov. In addition to enabling EISPC members and other stakeholders to identify areas with a high concentration of clean energy resources that could provide significant power generation in the future, another objective of the study was to promote open and transparent collaboration among state-level energy planning and regulatory agencies and to foster consistent and coordinated direction for regional and interconnection-level electricity analyses and planning. Funding for the project was provided by DOE’s Office of Electricity Delivery and Energy Reliability (DOE/OE) under the American Recovery and Reinvestment Act. Page

24 POWER TRANSMISSION AND DISTRIBUTION↗

Annual Report, Spring 2015: Alternative Chemical Cleaning Methods for High Level Waste Tanks – Corrosion Test Results

The testing presented in this report is in support of the investigation of the Alternative Chemical Cleaning program to aid in developing strategies and technologies to chemically clean radioactive High Level Waste tanks prior to tank closure. The data and conclusions presented here were the examination of the corrosion rates of A285 carbon steel and 304L stainless steel when interacted with the chemical cleaning solution composed of 0.18 M nitric acid and 0.5 wt. % oxalic acid. This solution has been proposed as a dissolution solution that would be used to remove the remaining hard heel portion of the sludge in the waste tanks. This solution was combined with the HM and PUREX simulated sludge with dilution ratios that represent the bulk oxalic cleaning process (20:1 ratio, acid solution to simulant) and the cumulative volume associated with multiple acid strikes (50:1 ratio). The testing was conducted over 28 days at 50°C and deployed two methods to invest the corrosion conditions; passive weight loss coupon and an active electrochemical probe were used to collect data on the corrosion rate and material performance. In addition to investigating the chemical cleaning solutions, electrochemical corrosion testing was performed on acidic and basic solutions containing sodium permanganate at room temperature to explore the corrosion impacts if these solutions were to be implemented to retrieve remaining actinides that are currently in the sludge of the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Chemical Cleaning Methods for High Level Waste Tanks: Actual Waste Testing with SRS Tank 5F Sludge

Solubility testing with actual High Level Waste tank sludge has been conducted in order to evaluate several alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge sluicing efforts. Tests were conducted with archived Savannah River Site (SRS) radioactive sludge solids that had been retrieved from Tank 5F in order to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent toward dissolving the bulk non-radioactive waste components. Solubility tests were performed by direct sludge contact with the oxalic/nitric acid reagent and with sludge that had been pretreated and acidified with dilute nitric acid. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid following current baseline tank chemical cleaning methods. One goal of testing with the optimized reagent was to compare the total amounts of oxalic acid and water required for sludge dissolution using the baseline and optimized cleaning methods. A second objective was to compare the two methods with regard to the dissolution of actinide species known to be drivers for SRS tank closure Performance Assessments (PA). Additionally, solubility tests were conducted with Tank 5 sludge using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closure Report for Corrective Action Unit 412: Clean Slate I Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 0

This Closure Report (CR) presents information supporting the clean closure of Corrective Action Unit (CAU) 412: Clean Slate I Plutonium Dispersion (TTR), located on the Tonopah Test Range, Nevada. CAU 412 consists of a release of radionuclides to the surrounding soil from a storage–transportation test conducted on May 25, 1963. Corrective action investigation (CAI) activities were performed in April and May 2015, as set forth in the Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 412: Clean Slate I Plutonium Dispersion (TTR), Tonopah Test Range, Nevada; and in accordance with the Soils Activity Quality Assurance Plan. The purpose of the CAI was to fulfill data needs as defined during the data quality objectives process. The CAU 412 dataset of investigation results was evaluated based on a data quality assessment. This assessment demonstrated the dataset is complete and acceptable for use in fulfilling the data needs identified by the data quality objectives process. This CR provides documentation and justification for the clean closure of CAU 412 under the FFACO without further corrective action. This justification is based on historical knowledge of the site, previous site investigations, implementation of the 1997 interim corrective action, and the results of the CAI. The corrective action of clean closure was confirmed as appropriate for closure of CAU 412 based on achievement of the following closure objectives: Radiological contamination at the site is less than the final action level using the ground troops exposure scenario (i.e., the radiological dose is less than the final action level): Removable alpha contamination is less than the high contamination area criterion: No potential source material is present at the site, and any impacted soil associated with potential source material has been removed so that remaining soil contains contaminants at concentrations less than the final action levels: and There is sufficient information to characterize investigation and remediation waste for disposal.

54 ENVIRONMENTAL SCIENCES↗

Alternative Enhanced Chemical Cleaning Basic Studies Results FY09

Due to the need to close waste storage tanks, chemical cleaning methods are needed for the effective removal of the heels. Oxalic acid is the preferred cleaning reagent for sludge heel dissolution, particularly for iron-based sludge, due to the strong complexing strength of the oxalate. However, the large quantity of oxalate added to the tank farm from oxalic acid based chemical cleaning has significant downstream impacts. Optimization of the oxalic acid cleaning process can potentially reduce the downstream impacts from chemical cleaning. To optimize oxalic acid usage, a detailed understanding of the chemistry of oxalic acid based sludge dissolution is required. Additionally, other acid systems may be required for specific waste components with low solubility in oxalic acid and as a means to reduce oxalic acid usage in general. Solubility tests were conducted using non-radioactive, pure metal phases known to be the primary phases present in High Level Waste sludge. The metal phases studied included the aluminum phases gibbsite and boehmite and the iron phases magnetite and hematite. Hematite and boehmite are expected to be the most difficult iron and aluminum phases to dissolve. These mineral phases have been identified in both SRS and Hanford High Level Waste sludge. Acids evaluated for dissolution included oxalic, nitric, and sulfuric acids. The results of the solubility tests indicate that oxalic and sulfuric acids are more effective for the dissolution of the primary sludge phases. For boehmite, elevated temperature will be required to promote effective phase dissolution in the acids studied. Literature reviews, thermodynamic modeling, and experimental results have all confirmed that pH control using a supplemental proton source (additional acid) is critical for minimization of oxalic acid usage during the dissolution of hematite. These results emphasize the importance of pH control in optimizing hematite dissolution in oxalic acid and may explain the somewhat limited success observed during recent attempts to remove sludge heels from SRS Tanks 5F and 6F using oxalic acid. Additionally, based on the results of the solubility tests conducted, the following conclusions can be drawn: (1) Hematite dissolution in oxalic acid is a stoichiometric process dependant upon the provision of sufficient oxalate molar equivalents to complex the iron and sufficient H{sup +} to promote the dissolution reaction. (2) The optimal utilization of oxalic acid for hematite dissolution requires an additional proton source, such as nitric acid, and a pH of {le} 1. In the absence of a supplemental proton source, greater than stoichiometric amounts of oxalate are required. (3) Magnetite is generally more soluble than hematite in all acids tested. (4) Gibbsite is generally more soluble than the boehmite form of aluminum in all acids tested. (5) The OLI Thermodynamic Model is a useful tool for the prediction of equilibrium iron concentrations, but predictions must be experimentally verified. The OLI model appears to over-predict the solubility of the iron and aluminum phases studied in mineral acids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

22X mask cleaning effects on EUV lithography process and lifetime

For this paper, we evaluated the impact of repetitive cleans on a photomask that was fabricated and patterned for extreme ultraviolet lithography exposure. The lithographic performance of the cleaned mask, in terms of process window and line edge roughness, was monitored with the SEMATECH Berkeley micro-exposure tool (MET). Each process measurement of the cleaned mask was compared to a reference mask with the same mask architecture. Both masks were imaged on the same day in order to eliminate any process-related measurement uncertainties. The cleaned mask was periodically monitored with atomic force microscopy (AFM) measurements and pattern widths were monitored using scanning electron microscopy (SEM). In addition, reflectivity changes were also tracked with the aid of witness plate measurements. At the conclusion of this study, the mask under evaluation was cleaned 22 times; with none of the evaluation techniques showing any significant degradation in performance.

36 MATERIALS SCIENCE↗

Agent-Based Modleing of Power Plants Placement to Evaluate the Clean Energy Standard Goal

There is a political push for utilities to supply a specified share of their electricity sales from clean energy resources under the clean energy standard (CES). The goal is to achieve 80% clean energy by 2035. However, there are uncertainties about the ability of the utility industry to ramp up quickly even with the incentives that will be provided. Water availability from the streams is one of the major factors. The contiguous United States is divided into eighteen water regions, and multiple states share water from a single water region. Consequently, water usage decisions made in one state (located upstream of a water region that crosses multiple states) will greatly impact what is available downstream in another state. In this paper, an agent-based modeling approach is proposed to evaluate the clean energy standard goal for water-dependent energy resources. Specifically, using a water region rather than a state boundary as a bounding envelope for the modeling and starting at the headwaters, virtual power plants are placed based on the conditions that there is: (i) suitable land to site a particular power plant, (ii) enough water that meet regulatory guidelines within 20 miles of the suitable land, and (iii) a 20-mile buffer zone from an existing or a virtual power plant. The results obtained are discussed in the context of the proposed clean energy standard goal for states that overlap with one water region.

agent-based modeling↗

Clean Energy Technologies for Economic Development at Global and Community Scales

Energy systems in communities across the world are undergoing fundamental transformations. Electricity and heat production is becoming cleaner and more distributed, driven by declining energy prices and higher technology efficiencies, as well as a desire to reduce environmental impact. The technologies that produce clean energy, such as solar photovoltaic panels, wind turbines, and lithium ion batteries for vehicles and storage, depend less on global fuel costs and more on costs for technology, manufacturing, and local resources. Therefore, innovations in manufacturing, systems integration, operations, and policies can reduce clean energy costs across all the links in the energy supply chain. The advanced and cleaner energy systems being deployed have resulted in communities gaining a greater role in creating and using energy from local resources, as well as increasing their participation in the value chain from research, manufacturing, and deployment. The clean energy trends are expected to continue and perhaps grow through expansion of clean energy technologies for industrial and transportation sectors, although there are many possible future scenarios due to the diversity of resources and societal objectives in different communities, countries, and regions. This presentation will summarize the status and potential futures of key clean energy technologies and their manufacturing and deployment, with discussion of opportunities for sustainable communities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NREL's 100% Clean Electricity by 2035 Study

The 100% Clean Electricity by 2035 Study evaluates a variety of scenarios that achieve a 100% clean electricity system (defined as zero net greenhouse gas emissions) in 2035 that could put the United States on a path to economywide net-zero emissions by 2050. The scenarios focus primarily on the supply of clean electricity, including technical requirements, challenges, and benefit and cost implications. The study results highlight multiple pathways to 100% clean electricity in which benefits exceed costs. The study does not comprehensively evaluate all options to achieve 100% clean electricity, and it focuses largely on supply-side options. This summary deck provides a high-level overview of the key findings.

clean electricity↗

Implementing Clean Energy Transitions for Small Communities: NREL Supports Sierra Club Florida in Efforts to Help Florida Communities Achieve 100% Renewable Energy

Sierra Club Florida's "Clean Energy for All" campaign helps communities in Florida transition to 100% clean energy. The organization sought the help of National Renewable Energy Laboratory (NREL) analysts to achieve to achieve two goals: (1) create a Clean Energy Toolkit to help communities in Florida and across the country find data and and analysis to achieve clean energy goals, and (2) provide direct analysis of local clean energy potential for two Florida communities, the cities of Tallahassee and Sarasota.

clean energy toolkit↗