Search NASA⌕ Search

SEARCH · Search NASA

Results for “Communication aggregation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Reduced-Order Aggregated Model for Parallel Inverter Systems with Virtual Oscillator Control

This paper introduces a reduced-order aggregated model for parallel-connected inverters controlled with virtual oscillator control (VOC). The premise of VOC is to modulate inverter dynamics to emulate those of nonlinear oscillators with the goal of realizing a stable ac microgrid in the absence of communication, synchronous generation, or a stiff grid. To obtain a reduced-order model for a system of parallel-connected inverters with VOC, we first formulate a set of scaling laws that describe how the controller and filter parameters of a given inverter depend on its voltage and power rating. Subsequently, we show that N parallel inverters which adhere to this scaling law can be modeled with the same structure and hence the same computational burden of the model of a single inverter. The proposed aggregate model is experimentally validated on a system of three parallel inverters with heterogeneous power ratings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Reduced-Order Aggregated Model for Parallel Inverter Systems with Virtual Oscillator Control: Preprint

This paper introduces a reduced-order aggregated model for parallel-connected inverters controlled with virtual oscillator control (VOC). The premise of VOC is to modulate inverter dynamics to emulate those of nonlinear oscillators with the goal of realizing a stable ac microgrid in the absence of communication, synchronous generation, or a stiff grid. To obtain a reduced-order model for a system of parallel-connected inverters with VOC, we first formulate a set of scaling laws that describe how the controller and filter parameters of a given inverter depend on its voltage and power rating. Subsequently, we show that N parallel inverters which adhere to this scaling law can be modeled with the same structure and hence the same computational burden of the model of a single inverter. The proposed aggregate model is experimentally validated on a system of three parallel inverters with heterogeneous power ratings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooperative Server Clustering for a Scalable GAS Model on petascale cray XT5 Systems

Global Address Space (GAS) programming models are attractive because they retain the easy-to-use addressing model that is the characteristic of shared-memory style load and store operations. The scalability of GAS models depends directly on the design and implementation of runtime libraries on the targeted platforms. In this paper, we examine the memory requirement of a popular GAS runtime library, Aggregate Remote Memory Copy Interface (ARMCI) on petascale Cray XT 5 systems. Then we describe a new technique cooperative server clustering that enhances the memory scalability of ARMCI communication servers. In cooperative server clustering, ARMCI servers are organized into clusters, and cooperatively process incoming communication requests among them. A request intervention scheme is also designed to expedite the return of responses to the initiating processes. Our experimental results demonstrate that, with very little impact on ARMCI communication latency and bandwidth, cooperative server clustering is able to significantly reduce the memory requirement of ARMCI communication servers, thereby enabling highly scalable scientific applications. In particular, it dramatically reduces the total execution time of a scientific application, NWChem, by 45% on 2400 processes.

99 GENERAL AND MISCELLANEOUS↗

Cooperative Server Clustering for a Scalable GAS Model on Petascale Cray XT5 Systems

Global Address Space (GAS) programming models are attractive because they retain the easy-to-use addressing model that is the characteristic of shared-memory style load and store operations. The scalability of GAS models depends directly on the design and implementation of runtime libraries on the targeted platforms. In this paper, we examine the memory requirement of a popular GAS run-time library, Aggregate Remote Memory Copy Interface (ARMCI) on petascale Cray XT 5 systems. Then we describe a new technique, cooperative server clustering, that enhances the memory scalability of ARMCI communication servers. In cooperative server clustering, ARMCI servers are organized into clusters, and cooperatively process incoming communication requests among them. A request intervention scheme is also designed to expedite the return of responses to the initiating processes. Our experimental results demonstrate that, with very little impact on ARMCI communication latency and bandwidth, cooperative server clustering is able to significantly reduce the memory requirement of ARMCI communication servers, thereby enabling highly scalable scientific applications. In particular, it dramatically reduces the total execution time of a scientific application, NWChem, by 45% on 2400 processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Open Source Extensible Smart Energy Framework

Aggregated distributed energy resources are the subject of much interest in the energy industry and are expected to play an important role in meeting our future energy needs by changing how we use, distribute and generate electricity. This energy future includes an increased amount of energy from renewable resources, load management techniques to improve resiliency and reliability, and distributed energy storage and generation capabilities that can be managed to meet the needs of the grid as well as individual customers. These energy assets are commonly referred to as Distributed Energy Resources (DER). DERs rely on a means to communicate information between an energy provider and multitudes of devices. Today DER control systems are typically vendor-specific, using custom hardware and software solutions. As a result, customers are locked into communication transport protocols, applications, tools, and data formats. Today’s systems are often difficult to extend to meet new application requirements, resulting in stranded assets when business requirements or energy management models evolve. By partnering with industry advisors and researchers, an implementation DER research platform was developed called the Smart Energy Framework (SEF). The hypothesis of this research was that an open source Internet of Things (IoT) framework could play a role in creating a commodity-based eco-system for DER assets that would reduce costs and provide interoperable products. SEF is based on the AllJoynTM IoT open source framework. The demonstration system incorporated DER assets, specifically batteries and smart water heaters. To verify the behavior of the distributed system, models of water heaters and batteries were also developed. An IoT interface for communicating between the assets and a control server was defined. This interface supports a series of “events” and telemetry reporting, similar to those defined by current smart grid communication standards. The results of this effort demonstrated the feasibility and application potential of using IoT frameworks for the creation of commodity-based DER systems. All of the identified commodity-based system requirements were met by the AllJoyn framework. By having commodity solutions, small vendors can enter the market and the cost of implementation for all parties is reduced. Utilities and aggregators can choose from multiple interoperable products reducing the risk of stranded assets. Based on this research it is recommended that interfaces based on existing smart grid communication protocol standards be created for these emerging IoT frameworks. These interfaces should be standardized as part of the IoT framework allowing for interoperability testing and certification. Similarly, IoT frameworks are introducing application level security. This type of security is needed for protecting application and platforms and will be important moving forward. Recommendations are that along with DER-based data model interfaces, platform and application security requirements also be prescribed when IoT devices support DER applications.

25 ENERGY STORAGE↗

Facility Cybersecurity Framework Best Practices Version 2.0

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facility Cybersecurity Framework Best Practices Version 2.0

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Inverter Functions and Communication Protocols for Distribution Management

This paper aims at identifying the advanced features required by distribution management systems (DMS) service providers to bring inverter-connected distributed energy resources into use as an intelligent grid resource. This work explores the standard functions needed in the future DMS for enterprise integration of distributed energy resources (DER). The important DMS functionalities such as DER management in aggregate groups, including the discovery of capabilities, status monitoring, and dispatch of real and reactive power are addressed in this paper. It is intended to provide the industry with a point of reference for DER integration with other utility applications and to provide guidance to research and standards development organizations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient On-demand Connection Management Mechanisms with PGAS Models on InfiniBand

In the last decade or so, clusters have observed a tremendous rise in popularity due to the excellent price to performance ratio. A variety of Interconnects have been proposed during this period, with InfiniBand leading the way due to its high performance and open standard. At the same time, multiple programming models have emerged in order to meet the requirements of various applications and their programming models. To support requirements of multiple programming models, InfiniBand provides multiple transport semantics, ranging from unreliable connectionless to reliable connected characteristics. Among them, the reliable connection (RC) semantics is being widely due to its high performance and support for novel features like Remote Direct Memory Acesss (RDMA), hardware atomics and Network Fault Tolerance. However, the pairwise connection oriented nature of the RC transport semantics limits its scalability and usage at the increasing processor counts. In this paper, we design and implement on-demand connection management approaches in the context of Partitioned Global Address Space (PGAS) programming models, which provided shared memory abstraction and one-sided communication semantics, leading to the development of multiple languages (UPC, X10, Chapel) and libraries (Global Arrays, MPI-RMA). Using Global Arrays as the research vehicle, we implement this approach with Aggregate Remote Memory Copy Interface (ARMCI), the runtime system of Global Arrays. We evaluate our approach, ARMCI-On Demand Connection Management (ARMCI-ODCM) using various microbenchmarks and benchmarks (LU Factorization, RandomAccess and Lennard Jones simulation) and application (Subsurface transport over multiple phases (STOMP)). With the performance evaluation for up to 4096 processors, we are able to have a multi-fold reduction in connection memory with a negligible degradation in performance. Using STOMP at 4096 processors, reduces the overall connection memory by 66 times with no performance degradation. To the best of our knowledge, this is the first design, implementation and evaluation of on-demand connection management with InfiniBand using PGAS models.

54 ENVIRONMENTAL SCIENCES↗

Structure of trigger factor binding domain in biologically homologous complex with eubacterial ribosome reveals its chaperone action

Trigger factor (TF), the first chaperone in eubacteria to encounter the emerging nascent chain, binds to the large ribosomal subunit in the vicinity of the protein exit tunnel opening and forms a sheltered folding space. Here, we present the 3.5-{angstrom} crystal structure of the physiological complex of the large ribosomal subunit from the eubacterium Deinococcus radiodurans with the N-terminal domain of TF (TFa) from the same organism. For anchoring, TFa exploits a small ribosomal surface area in the vicinity of proteins L23 and L29, by using its 'signature motif' as well as additional structural elements. The molecular details of TFa interactions reveal that L23 is essential for the association of TF with the ribosome and may serve as a channel of communication with the nascent chain progressing in the tunnel. L29 appears to induce a conformational change in TFa, which results in the exposure of TFa hydrophobic patches to the opening of the ribosomal exit tunnel, thus increasing its affinity for hydrophobic segments of the emerging nascent polypeptide. This observation implies that, in addition to creating a protected folding space for the emerging nascent chain, TF association with the ribosome prevents aggregation by providing a competing hydrophobic environment and may be critical for attaining the functional conformation necessary for chaperone activity.

36 MATERIALS SCIENCE↗

PV Generation and Load Forecasting for Adjuntas PR Community Microgrids

Existing frameworks to forecast time-series photovoltaic (PV) output power and consumer load for microgrid operations and controls assume a near-continuous availability of real-time input features from the field assets such as PV inverters, energy meters, and weather station. These incoming data points are used to periodically retrain models and update forecast snapshots over a moving horizon window, be it one hour-ahead, one-day ahead, or one-week ahead. However, such frameworks are not resilient to disruptions in data availability caused by losses in communications between the field sensors and data loggers. Hence, there is a need for programs that assume no availability of real-time microgrid asset data and still make reliable forecasts that can be used for decision-making. Such programs would be apt to function in extreme weather events such as hurricanes and would use lightweight recursive time-series models to independently forecast solar irradiance and ambient temperature, then compute PV power from those forecasts, as well as independently forecast consumer load. The codebase performs forecasting for the scenario of when the microgrid does not have a reliable access to forecasts or real-time observations of solar irradiance (I) and ambient temperature (AT) and load (Load) to be able to adequately forecast, in real-time, the PV power production or a business' load. In this case, using historical values of PV power and load, a univariate forecasting of generation and consumption are respectively made. The use-case in particular has two sub-scenarios: one, a normal 7-day ahead forecast where the unavailability of real-time data is assumed due to infrastructure issues such as loss of communication or sensor maintenance or service downtimes. Whereas a hurricane-caused unavailability of real-time data requires a second model trained specifically on historical hurricane days to be able to capture the extreme day behavior of generation in particular, and load if applicable. A gradient boosted regression tree comprises an ensemble of additive models that map between the input of historical values (be it irradiance, temperature, or load) and their corresponding output forecasts of a given horizon such that the individual learner predictions are summed up over the total number of such learners in the ensemble to produce an aggregate forecast. A weighting mechanism is applied to the training data in each iteration, where actual and forecast values are compared to penalize incorrect forecasts by increasing the weight and reducing it to reward correct forecasts. The code's benefits are that it: (a) accounts for a contingency where communication loss renders newly measured real-time data unavailable for model tuning and snapshot updates; (b) presents blind forecasting that recursively determines the next time-step value in a horizon using the forecast of the same attribute from a prior step; and (c) employs lightweight models that, once trained, can reliably generalize for different horizons, which make them suitable for enhancing the resilience of field microgrids prone to extreme events that encounter disruptions to data availability.

Sundararajan, Aditya [Oak Ridge National Laborator↗

VOLTTRON/volttron-GS

PNNL grid related applications Object oriented design intended to facilitate reuse and extensibility of system features. The template enforces that needed structure and behaviors are available. Users may inherit and adapt these structures and behaviors to meet their specific requirements. Recognizes separation of the transactive system calculations into (1) scheduling of assets, (2) balancing of supply and demand, and (3) coordination among independent agents. This separation facilitates useful computation boundaries in which computations can be completed without requiring end-to-end communication for each update. The code provides fundamental market solutions for balancing. The code provides mechanisms for inter-agent coordination. Allows event-driven agent interactions; not limited to prescribed time intervals. Aggregates value and electricity at nodes and conveys opportunities up and down through the network.

Hammerstrom, Don↗

Enhancing I/O Throughput via Efficient Routing and Placement for Large-scale Parallel File Systems

As storage systems get larger to meet the demands of petascale systems, careful planning must be applied to avoid congestion points and extract the maximum performance. In addition, the large data sets generated by such systems makes it desirable for all compute resources to have common access to this data without needing to copy it to each machine. This paper describes a method of placing I/O close to the storage nodes to minimize contention on Cray s SeaStar2+ network, and extends it to a routed Lustre configuration to gain the same benefits when running against a center-wide file system. Our experiments using half of the resources of Spider the center-wide file system at the Oak Ridge Leadership Computing Facility show that I/O write bandwidth can be improved by up to 45% (from 71.9 to 104 GB/s) for a direct-attached configuration and by 137% (47.6 GB/s to 115 GB/s) for a routed configuration. We demonstrated up to 20.7% reduction in run-time for production scientific applications. With the full Spider system, we demonstrated over 240 GB/s of aggregate bandwidth using our techniques.

99 GENERAL AND MISCELLANEOUS↗

VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable multiscale modeling of platelets with 100 million particles

Here, we developed the core components of the AI-aided multiple time stepping algorithm for multiscale modeling of cell dynamics. This algorithm was implemented and analyzed on two supercomputer architectures with an application of simulating the aggregation of 250 platelets, or 102 million particles. To scale on these computers with complex memory and network architectures with GPUs, we devised a biomechanics-informed task mapping scheme to optimize load imbalance, communications, and memory utilization. Our simulations, scaling well up to 192 nodes on a Summit-like supercomputer with a peak speed of 11 petaflops, achieved a rate of 423 μs/day which is 500 times faster than the conventional algorithm using static time step and this has enabled studies of record size blood clots at record spatial–temporal resolutions. Additionally, we discovered the sensitive dependence of the scalability and execution time on the methods of decomposition, CPU–GPU coupling, and task mapping.

97 MATHEMATICS AND COMPUTING↗

HiCOO: Hierarchical cooperation for scalable communication in Global Address Space programming models on Cray XT systems

Global Address Space (GAS) programming models enable a convenient, shared-memory style addressing model. Typically this is realized through one-sided operations that can enable asynchronous communication and data movement. With the size of petascale systems reaching 10,000s of nodes and 100,000s of cores, the underlying runtime systems face critical challenges in (1) scalably managing resources (such as memory for communication buffers), and (2) gracefully handling unpredictable communication patterns and any associated contention. For any solution that addresses these resource scalability challenges, equally important is the need to maintain the performance of GAS programming models. In this paper, we describe a Hierarchical COOperation (HiCOO) architecture for scalable communication in GAS programming models. HiCOO formulates a cooperative communication architecture: with inter-node cooperation amongst multiple nodes (a.k.a multinode) and hierarchical cooperation among multinodes that are arranged in various virtual topologies. We have implemented HiCOO for a popular GAS runtime library, Aggregate Remote Memory Copy Interface (ARMCI). By extensively evaluating different virtual topologies in HiCOO in terms of their impact to memory scalability, network contention, and application performance, we identify MFCG as the most suitable virtual topology. The resulting HiCOO architecture is able to realize scalable resource management and achieve resilience to network contention, while at the same time maintaining or enhancing the performance of scientific applications. In one case, it reduces the total execution time of an NWChem application by 52%.

Computer Science↗