Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Tank Farm Safety Programmable System Software Management Plan

This Software Management Plan (SMP) applies to the configurable programmable logic controller (PLC) software configured as the Tank Farms Safety Programmable System (TFSPS). The TFSPS is identified as a safety-significant (SS) system to prevent loss of the safety function of SS structures, systems, and components (SSC). The TFSPS software is classified as grade level A configurable safety software. The TFSPS consists of safety instrumented systems (SIS) and safety instrumented alarm (SIA) systems.The purpose of this management plan is to describe how Washington River Protection Solutions (WRPS) will configure and manage the TFSPS software and the associated software life cycle (SLC). TFSPS software shall be configured by Process and Control Systems Engineering (P&CSE) as grade level A safety software for use by Production Operations as the primary stakeholders.

97 MATHEMATICS AND COMPUTING↗

Communication devices for network-hopping communications and methods of network-hopping communications

Wireless communication devices include a software-defined radio coupled to processing circuitry. The system controller is configured to execute computer programming code. Storage media is coupled to the system controller and includes computer programming code configured to cause the system controller to configure and reconfigure the software-defined radio to operate on each of a plurality of communication networks according to a selected sequence. Methods for communicating with a wireless device and methods of wireless network-hopping are also disclosed.

97 MATHEMATICS AND COMPUTING↗

Closeout of CRADA JSA 2012S004: Chapter 5, Integrated Control System, of the document of the ESS Conceptual Design Report, publicly available at https://europeanspallationsource.se/accelerator-documents

The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED database management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Interleaved multi-channel, multi-level, multi-quadrant DC-DC converters

Direct-current-to-direct-current (DC-DC) power converters that include two or more multi-quadrant, multi-level, DC-DC, switching converter subcircuits, connected in parallel at respective input and output sides, so as to provide a multi-channel, multi-quadrant, multi-level configuration, are disclosed. The DC-DC power converters further include a control circuit configured to control the switching converter subcircuits so that corresponding switching semiconductors in each of the switching converter subcircuits are switched in an interleaved manner. In some embodiments, each of the switching converter subcircuits is a three-level, neutral-point-clamped, four-quadrant DC-DC converter circuit. In other embodiments, each of the switching converter subcircuits is a three-level, neutral-point-clamped, two-quadrant DC-DC converter circuit. In any of these embodiments, a filter capacitor may be connected between across a pair of output terminals at the output sides of the switching converter subcircuits.

Du, Yu↗

Measure Guideline: Condensing Boilers—Control Strategies for Optimizing Performance and Comfort in Residential Applications

The combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater has become a common option for high-efficiency residential space heating in cold climates. While there are many condensing boilers available on the market with rated efficiencies in the low to mid 90% efficient range, it is imperative to understand that if the control systems are not properly configured, these heaters will perform no better than their non-condensing counterparts. Based on previous research efforts, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency (Arena 2010). It was found that there is a significant lack of information for contractors on how to configure the control systems to optimize overall efficiency. For example, there is little advice on selecting the best settings for the boiler reset curve or how to measure and set flow rates in the system to ensure that the return temperatures are low enough to promote condensing. It has also been observed that recovery from setback can be extremely slow and, at times, not achieved. Recovery can be affected by the outdoor reset control, the differential setting on the boiler and over-sizing of the boiler itself. This guide is intended for designers and installers of hydronic heating systems interested in maximizing the overall system efficiency of condensing boilers when coupled with baseboard convectors. It is applicable to new and retrofit applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water heater control module

An advanced electric water heater control system that interfaces with a high temperature cut-off thermostat and an upper regulating thermostat. The system includes a control module that is electrically connected to the high-temperature cut-off thermostat and the upper regulating thermostat. The control module includes a switch to open or close the high-temperature cut-off thermostat and the upper regulating thermostat. The control module further includes circuitry configured to control said switch in response to a signal selected from the group of an autonomous signal, a communicated signal, and combinations thereof.

42 ENGINEERING↗

Incremental rotary rolling mill and method

A rolling mill system for Incremental rotary shaping of an elongated workpiece is provided that includes first and second workpiece holders. A support frame has a track with the first and second workpiece holders being movably associated with the track, the workpiece holders and an associated workpiece being movable in unison along the track. A radial chuck is mounted to the frame that includes a plurality of jaws that are movable radially inwardly and outwardly. Each jaw has a tool mounted thereto that is rotatable about an axis of rotation, with the axis of rotation of each tool being oriented at a skew angle relative to the longitudinal axis of a workpiece. A source of electric current and an electrically conductive flow path are provided for flowing electrical current through a workpiece. A controller is provided that is configured to control the operation of each of the first motor, second motor and third motor, and to control the flow of current flowing through the tools to the workpiece.

Zeng, Qiang↗

Internal combustion engine and method for control

In one exemplary embodiment of the invention an internal combustion engine includes a piston disposed in a cylinder, a valve configured to control flow of air into the cylinder and an actuator coupled to the valve to control a position of the valve. The internal combustion engine also includes a controller coupled to the actuator, wherein the controller is configured to close the valve when an uncontrolled condition for the internal engine is determined.

33 ADVANCED PROPULSION SYSTEMS↗

Cold start strategy and system for gasoline direct injection compression ignition engine

A method for starting a compression ignition engine having at least one cylinder with a reciprocating piston located therein, an intake valve configured to control the intake of air to an intake port of the cylinder and an exhaust valve configured to control the expulsion of gas from an exhaust port of the cylinder. The method includes the steps of: cranking the engine, conditioning intake air at the intake port of the cylinder to raise the temperature of air in the cylinder, controlling a valve timing the intake valve and/or the exhaust valve to allow the piston to compress the air within the cylinder, thereby increasing the temperature of the air within the cylinder, and injecting fuel into the cylinder when the air within the cylinder has been heated to a temperature sufficient to support compression ignition of a gasoline and air mixture within the cylinder.

Sellnau, Mark C.↗

Control mechanism for attenuation of thermal energy pulses using cold circulators in the cryogenic distribution system of fusion devices in tokamak configuration

Operation and control of superconducting (SC) magnets in the fusion devices having tokamak configuration opens up the domain of varying peak thermal energy environment as a function of time, commensurate with the plasma pulses. The varied thermal energy environment, thus propagated to upstream of the cooling system, is responsible for the system level instability of the overall cryogenic system. The cryogenic distribution system, the regime of first impact point, therefore, has to be tuned so as to stay at the nearly stable zone of operation. The configuration of the cryogenic distribution system, considered in the present study, involves a liquid helium (LHe) bath as a thermal buffer, LHe submerged heat exchangers and cold circulator apart from the valves for implementations of the precise controls. The cold circulator supplies the forced flow supercritical helium, used for the cooling of SC magnets. The transients of the thermal energy pulses can be attenuated in the cryogenic distribution system by various methodologies. One of the adopted methodologies in the present study is with the precise speed control of the cold circulators. The adopted methodology is applied to various configurations of arrangements of internal components in the distribution system for obtaining system responses with superior attenuation of energy pulses. The process simulation approach, assumptions, considered inputs and constraints, process modeling with different configuration as well as results to accomplish the control scheme for the attenuation of the thermal energy pulses are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

VARIABLE DC LINK CONVERTER AND TRANSFORMER FOR WIDE OUTPUT VOLTAGE RANGE APPLICATIONS

A variable direct current (DC) link power converter is described. In one example, the power converter includes a first converter stage configured to convert power from a power source to power at an intermediate link voltage and a second converter stage configured to convert the power at the intermediate link voltage to power for charging a battery. The power converter further includes a control system having an intermediate link voltage regulation control loop configured, in a first mode of operation, to regulate the intermediate link voltage through the first converter stage based on a voltage of the battery, and a ripple regulation control loop configured to sense a charging current for the battery and regulate a gain of the second converter stage based on the charging current to reduce ripple in the charging current. A new configuration of transformer suitable for use with the power converter is also described.

42 ENGINEERING↗

Basement rock hybrid drilling

A system for monitoring and controlling downhole pressure of a well borehole relative to a lithostatic pressure of rock surrounding the borehole is provided. The system can include a millimeter wave drilling apparatus including a gyrotron configured to inject millimeter wave radiation energy into a borehole of a well via a waveguide configured for insertion into the borehole. The borehole can be formed via the millimeter wave drilling apparatus and having a downhole pressure monitored at a bottom of the well. The system can also include a compressor fluidically coupled to the borehole and configured to control the downhole pressure via a gas supplied into and/or received from the borehole. The compressor can be configured to control the downhole pressure relative to a lithostatic pressure determined for rock surrounding the well at the bottom of the well.

Araque, Carlos↗

Process control monitoring systems, industrial plants, and process control monitoring methods

A system comprises a valve; a plurality of RFID sensor assemblies coupled to the valve to monitor a plurality of parameters associated with the valve; a control tag configured to wirelessly communicate with the respective tags that are coupled to the valve, the control tag being further configured to communicate with an RF reader; and an RF reader configured to selectively communicate with the control tag, the reader including an RF receiver. Other systems and methods are also provided.

Skorpik, James R↗

System and method for determining tow parameters

A system for determining one or more characteristics of a carbon fiber tow. The system including a first laser profilometer, a second laser profilometer, and a controller. The first laser profilometer is located on a first side of the carbon fiber tow. The second laser profilometer is located on a second side of the carbon fiber tow. The controller is configured to receive, from the first profilometer, a first profile of the first side of the carbon fiber tow, and receive, from the second profilometer, a second profile of the second side of the carbon fiber tow. The controller is further configured to determine at least one characteristic selected from a group consisting of a tow width of the carbon fiber tow, a tow fuzz of the carbon fiber tow, a tow thickness of the carbon fiber tow, and a tow angle of the carbon fiber tow, the at least one characteristic based on the first profile and the second profile. The controller further configured to output the at least one characteristic of the carbon fiber tow.

36 MATERIALS SCIENCE↗

Cyber Awareness Visualization And Event Action Tool

This tool allows the simplified and informed visualization of any data analytics tool with the ability to match the CAVEAT format. CAVEAT is capable of having any kind of control room configured with any arbitrary number of control surfaces.

Lehmer, JacobP.↗

Edge coating apparatus with movable roller applicator for solar cell substrates

A non-contact edge coating apparatus includes an applicator for applying a coating material on an edge of a solar cell substrate and a control system configured to drive the applicator. The control system may drive the applicator along an axis to maintain a distance with an edge of the substrate as the substrate is rotated to have the edge coated with a coating material. The applicator may include a recessed portion into which the edge of the substrate is received for edge coating. For example, the applicator may be a roller with a groove. Coating material may be introduced into the groove for application onto the edge of the substrate. A variety of coating materials may be employed with the apparatus including hot melt ink and UV curable plating resist.

42 ENGINEERING↗

Multi-phase AC/AC step-down converter for distribution systems

A step-down AC/AC converter for use in an electric distribution system includes at least one chopper circuit for each one of a plurality of phases of the AC power, each chopper circuit including a four-quadrant switch coupled in series between primary and secondary sides of the chopper circuit and a current-bidirectional two-quadrant switch coupled between the secondary side of the chopper circuit and a common node. Each current-bidirectional two-quadrant switch is oriented in the same direction, with respect to the secondary side of the corresponding chopper circuit and the common node. The converter further includes a control circuit configured to pulse-width-modulate control inputs of the switches, to convert a first multiphase AC voltage at the primary sides of the chopper circuits to a second multiphase AC voltage at the secondary sides of the chopper circuits, the second multiphase AC voltage being lower in voltage than the first multiphase AC voltage.

24 POWER TRANSMISSION AND DISTRIBUTION↗