Search NASA⌕ Search

SEARCH · Search NASA

Results for “Construction & building technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Building the Efficiency Workforce: Preprint

Demand for high-performance homes and buildings is growing due to their marketability, environmental benefits, and increasing affordability. Growth for energy efficient technologies and building upgrades has driven expansion across many traditional industries including construction trades (which added almost 21,000 jobs) and professional services (which added 35,000 employees) in 2018, according to the 2019 U.S. Energy Employment Report (USEER). As buildings become more automated, digitized and interconnected, the workforce that supports the design, build, operations and maintenance of these buildings must evolve. The U.S. Department of Energy’s Building Technologies Office (BTO) has engaged NREL to provide a framework upon which BTO can develop their next generation workforce development strategy. The strategy will be designed to increase quantity of workers with the skills to adequately design, install, maintain and operate high- performance buildings across all building sectors (residential, commercial, industrial). This paper will summarize past BTO workforce development efforts, identify current skills gaps and hiring challenges, and present anticipated future workforce needs based on new technologies currently being developed by labs and industry. Through a literature review and a series of industry and academic workshops, NREL will present a framework that includes multiple options to best prepare the next generation workforce.

buildings↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opaque Envelopes: Pathway to Building Energy Efficiency and Demand Flexibility: Key to a Low-Carbon, Sustainable Future

The opaque envelope - the barrier that helps maintain comfortable indoor conditions regardless of prevailing outdoor conditions - is the single largest contributor to primary energy use in residential and commercial buildings. Residential and commercial buildings comprise 39% of total U.S. primary energy use [1]. The opaque envelope affects 25% of building energy use, or 10% of total U.S. primary energy use [2]. High-performance opaque envelope technologies, therefore, have substantial potential to reduce energy use in both new construction and existing buildings. Retrofits are particularly crucial to realizing the energy savings potential of the opaque envelope because nearly 85% of residential and 55% of commercial buildings that exist today will still exist in 2050 [1]. Building envelope performance is also important for occupant comfort, productivity, health, and well-being. Improving the energy performance of the opaque envelope in U.S. buildings is critical to achieving aggressive cli- mate goals that support a clean energy economy and an equitable energy future for all Americans. By reducing total building energy use and improving energy efficiency, envelope research and development (R&D) will have a significant impact on how low-carbon buildings can mitigate climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Building Stock Characterization Study: A National Typology for Decarbonizing U.S. Buildings

To support the U.S. Department of Energy's (DOE's) Advanced Building Construction (ABC) Collaborative, the National Renewable Energy Laboratory (NREL) has been tasked with characterizing the U.S. building stock and developing a national typology of buildings. The potential use cases of such a typology are flexible and evolving, but in this initial phase, the primary intention is to help identify technology requirements and engineering solutions for moving the U.S. building stock toward a zero-carbon future by mid-century. This typology will also support the development of appropriate ABC research goals for existing buildings, such as cost targets for new technology development, and in a later phase, the typology can be used to support the implementation of ABC solutions by informing market aggregation and business model development. The ABC Initiative invests in new technologies that enable high building performance, can be deployed quickly with minimal onsite construction time, and are affordable and appealing to building owners, investors, and occupants. Funding awardees use many innovations, including new building materials, 3D printing, offsite manufacturing, robotics, and digital art-to-part. Although the goals of ABC cover a broad range of objectives around energy, comfort, and health, the primary ABC-related application of this national building characterization study is the development of retrofit packages that can be applied to reduce thermal loads in buildings. Retrofit packages will be determined collaboratively by the DOE and the ABC Collaborative. We anticipate a range of upgrade measures covering envelope-, HVAC-, and water-heating-related loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opening the Door to Grid-Interactive Efficient Buildings with Energy Codes

Building codes represent standard design practice in the construction industry and must continually evolve to account for advancing technologies and innovative practices. Energy codes have historically focused on energy efficiency within buildings and across their systems. However, many of tomorrow's technologies go beyond efficiency and target increased flexibility. These demand flexibility (DF) measures can postpone or reduce building electric load based on price or other grid signals, and include smart appliances, connected lighting, and connected mechanical systems. Expanding codes to enable such grid-interactive efficient building (GEB) has the potential to influence their realization at scale, which will support renewable-energy grid-integration and building-sector decarbonization. However, considering DF measures in code development creates a new set of challenges for codes and the practices contained therein. This paper considers the role of building energy codes in enabling GEB. Specifically, it reviews the status of demand flexibility (DF) measures in current commercial building energy code. It examines the national model code development process and identifies components barring the consideration and inclusion of DF measures - including code scope, characterization and analysis of proposed new prescriptive measures, and accounting for time-of-day and geographic differences in their benefits. The paper presents findings from code development analyses that indicate the cost benefit of DF measures and the limitations associated with current code development conventions. To encourage building flexibility and improved energy resilience moving forward, recommendations are made for removing code development barriers and sanctioning DF measure consideration in future model codes.

Building Energy Codes and Standards, Grid-Interact↗

Novel, Simplified Air Delivery System Design Gets Commercialized

Typical air delivery systems require contractors to design systems that are complex, difficult to integrate into the framing and structural components of a home, and often do not meet the optimization demands of newer energy-efficient homes. This complex process can be a burden to already strained construction labor costs. However, a new technology simplifies duct system design to improve comfort and eliminate sources of installation error for residential air delivery systems.

Building America↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Driven Commercial Building Energy Code Compliance and Technology Inventory for New York City

Building Performance Standards (BPS) are gaining national traction. A BPS will require new processes in the design, construction, and operation of buildings that take the occupants into account and enable predictive analysis to ensure compliance with current and future GHG emissions caps. In New York City, most buildings over 25,000 square feet will be regulated by a BPS starting in 2024, regardless of whether it is new construction permitted under current energy codes or an existing building. This research is one of the first to begin the evaluation of a long-term series of building policies in the context of an open data ecosystem, in cooperation with city agencies. Existing building policies enacted in NYC have ranged from building energy benchmarking and labeling to energy audits to the regulation of GHG emission in buildings. Through the development of a dataset related to building technologies and energy consumption, this project can help to evaluate if meaningful conclusions can be drawn for the data that has been largely self-reported in compliance with city regulations. This project will also provide lessons learned from a deep dive into these types of datasets to provide best practices for municipalities or states seeking to embark on policies like those enacted in NYC. In addition, a Building Automation System (BAS) Stretch Standard of Care (SSOC) for owners, designers, and building operators will enable the measurement and predictive analysis of energy consumption and GHG emissions at the plant, system, or component level, in anticipation of regulated GHG limits on buildings based on energy use. The SSOC is expected to be suitable for use on a national level. The primary feature of an SSOC is a standardized format for a set of BAS points that can be used to control and to gather data from individual plants, systems, or components that are related to building energy consumption. This project examined how measurements compare to prescriptive or simulation-based energy code targets, finding little correlation between predictive 8760-hour energy modeling and actual energy consumption for a small sample (n=27) of buildings constructed after 2015. Other analysis found that, while large multifamily housing (MFH) buildings showed a general trend similar to predicted reductions in energy use from the implementation of model commercial energy codes, this trend was not evident in the office, K-12 school, and hotel use groups in NYC. No upward or downward trends in energy consumption were found when buildings were grouped by size. Energy audit data were analyzed and it appears that there is bias by audit company on measures recommended to clients. Further research should be performed to cross-analyze this with other attributes, such as building size, vintage, and number of stories. Analysis found that for 281 buildings that were permitted and completed after 2015 and had submitted benchmarking data in 2022, between 81% and 96% (by use group) were found to be in compliance with the 2024 to 2029 NYC BPS emission caps, and between 55% and 89% were in compliance with the 2030-2034 caps. This work is beneficial to the public in helping policymakers and building stakeholders better understand the wide-ranging implications of a BPS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Sizing of Resilience Solutions for the U.S. Army Reserve

Power or water outages in buildings threaten the ability of the military to support surrounding communities during natural disasters. Outages can last for days, weeks or months. Typical solutions include very expensive batteries and onsite generation that are sized based on historical power needs. The U.S. Army Reserve (USAR) has teamed up with the Pacific Northwest National Laboratory (PNNL) to develop a simulation framework that optimizes future power needs to reduce the cost of resilience solutions. The approach starts with the building. Power needs during an emergency event are simulated at the building end-use level, then loads are reduced through the selection of life cycle cost-effective building-level technology improvements. These new optimized loads are then fed into a microgrid sizing tool that dynamically constructs many different combinations of solar photovoltaic, battery storage, and generator resources to meet the load for hundreds of statistically generated outage scenarios. Six site assessments completed by USAR and PNNL in 2019 have resulted in a 1-14% reduction in overall investment when optimizing the buildings first before determining the generation requirements. This approach helps the Army secure critical missions and provide a 14 day-minimum supply of necessary energy and water in the most efficient manner.

buidlings, efficiency, resilience, FEDS, MCOR↗

Experiences with Mobile Units for Liquid RAW Management in Slovak and Czech Nuclear Power Plants - 20089

In Nuclear Power Plants VVER 440, Russian type of reactor there was designed auxiliary building where according to basic design all operational liquid radioactive waste (RAW) should be stored in large capacity tanks during the whole operational period. That's why there are in the auxiliary building several types of large storage tanks with different internal volume from 110 m{sup 3}, 460 m{sup 3} to 550 m{sup 3}. Storage tanks are usually situated in rooms with limited access and minimal handling space. Operational waste was here transported by the system of pipes from the reactor building. There is possibility to handle with the waste and set the pipeline in to the chosen storage tanks. Nobody takes care about the quality of waste in the storage tanks and waste waits for the period of decommissioning when it should be treated. The storage capacity was designed for the whole lifetime of nuclear power plant. Currently the life time of Nuclear Power Plant's (NPP) is extended and there is necessity to retrieve and treat the RAW in advance. Another reason why the stakeholder, who operates the NPPs, decides to treat the operational RAW during the operational period of NPP, is that there are still new requirements from safety point of view which need to have free available space for example because of potential accident. So treating the operational RAW during the life time of NPP is present issue. Because in basic design nobody cares how the RAW will be retrieved and treated in the future, there is usually no technology for that in existing NPP. Some of the NPPs build an additional building with suitable technologies for treatment or hire the company which offer mobile technology for retrieving the waste from the storage tanks. Wood Nuclear Slovakia PLC provides all activities within liquid RAW management projects by its own staff including management, design, construction and deployment of equipment, engineering support, as well as all RAW retrieval and solidification activities. We offer RAW management as a service without any significant changes in existing NPP's buildings and technology. It is always a technical challenge to conduct successful retrieval, pumping and treatment of RAW. The complex RAW retrieval system can be designed as tailored solution for any RAW storage according to known boundary conditions and specific needs. These systems are based on years of experience with RAW manipulation, processing and treatment and the whole RAW management knowledge by Wood Nuclear Slovakia LTD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Validation of Smart Building Technology Modules for Academic and Professional Education (Final Technical Report)

Smart building technologies can improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both college curricula and building professionals’ continuing education, there is a lack of systematic instruction on smart building technologies. Slipstream, partnering with Texas A&M University (TAMU), the Society of Building Science Educators (SBSE), and the National Institute of Building Sciences (NIBS), developed a semester-long smart building curriculum for college students and 16 training videos for building professionals and the general public. The education and training cover the drivers and benefits of smart building technologies, key building energy systems, the latest sensor technologies and IoT devices, and focus on topics related to smart building controls (i.e., energy management information systems, smart building control platforms, cybersecurity, grid-interactive-efficient buildings [GEBs], smart building control methods, and occupant-centric control). The smart building curriculum for college students was taught at TAMU in the Spring semester of 2024 as part of the validation process. Student feedback was collected and summarized in a validation report by TAMU. The curriculum material was also reviewed by SBSE faculty who are interested in teaching smart building technology-related courses. Suggestions on revisions and better adoption of the materials by other faculty across the architectural, engineering, and construction (AEC) domains were compiled in a distinct validation report by SBSE. The SBSE validation report was used to create structured subsets of the curriculum material for adoption at different levels in different sub-disciplines. These subsets are categorized and offered on the SBSE website (https://www.sbse.org/courses/Smart-Building-Technologies). The 16 training videos for building professionals and the general public were previewed by 17 industry experts, and feedback and suggested changes were incorporated into the final version of these videos. The videos are organized into a smart building technology training course and published on the Whole Building Design Guide website (https://www.wbdg.org/ce/doe/bto/sbtt), which is hosted by the National Institute of Building Sciences (NIBS). Project team members created marketing materials to promote the awareness of these free, publicly available education and training resources. Outreach and marketing activities included creating short promotional videos, building project webpages, making project announcements on social media, conducting an email campaign, and directly reaching out to faculties and building professionals. This report describes the project approach, provides outlines of the training materials, along with links to resources, and identifies lessons learned in creating the content. We also suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies in the real world.

99 GENERAL AND MISCELLANEOUS↗

Seismic Isolation of Major Advanced Reactor Systems for Economic Improvement and Safety Assurance

Advanced reactor concepts currently under development in the United States [e.g., the High-Temperature Gas Reactor (HTGR) of X-Energy and the Molten Chloride Fast Reactor (MCFR) of TerraPower] are striving to improve the economics of nuclear power primarily by using passively and ‘walk-away’ safe technologies in the reactor. The recently published report, ‘Future of Nuclear Energy in a Carbon-Constrained World’ by the Massachusetts Institute of Technology Energy Institute (MIT EI) has shown that a significant contributor to the capital cost of NPPs is the ‘civil works’ i.e., the construction of the balance of plant (BoP: all SSCs except those involved in power generation, e.g., reactor vessel) such as the buildings, containment dome, foundation, etc., which amount to almost half of the overnight capital cost. The report suggests that using advanced construction technologies such as seismic isolation and high-performance concrete to significantly reduce the capital costs of advanced reactors. This report demonstrates the application of two cost-cutting solutions on advanced reactor designs that are currently under development. These solutions include, (1) seismic base isolation, and (2) risk- and cost-based seismic design optimization including seismic isolation of individual components.

42 ENGINEERING↗