Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

NMPC for Mode-Switching Operation of Reversible Solid Oxide Cell Systems

Solid oxide cells (SOCs) are a promising dual-mode technology that generates hydrogen through high-temperature water electrolysis and generates power through a fuel cell reaction that consumes hydrogen. Reversible operation of SOCs requires a transition between these two modes for hydrogen production setpoints as the demand and price of electricity fluctuate. Moreover, a well-functioning control system is important to avoid cell degradation during mode-switching operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional integral (PI) control strategies, while ramping between the modes of hydrogen and power production. While both control methods provide similar performance in many metrics, NMPC significantly reduces cell thermal gradients and curvatures (mixed spatial-temporal partial derivatives) during mode switching. A dynamic process flowsheet of the reversible SOC system was developed in the open-source, equation-based IDAES modeling framework. Our IDAES dynamic simulation results show that NMPC can ramp the SOC system between hydrogen and power production targets within short mode-switching times. Moreover, NMPC can comply with operating limits in the SOC system more effectively than PI, and only NMPC can directly enforce user-specified limits for mixed spatial-temporal partial derivatives of temperature. This allows for management of the trade-off be-tween operating efficiency and cell degradation, which is dependent on these temperature curvatures.

Li, Mingrui↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators: Preprint

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Safe Operations at Roadway Junctions - Design Principles from Automated Guideway Transit

Herein this paper describes a system-level view of a fully automated transit system comprising a fleet of automated vehicles (AVs) in driverless operation, each with an SAE level 4 Automated Driving System, along with its related safety infrastructure and other system equipment. This AV system-level control is compared to the automatic train control system used in automated guideway transit technology, particularly that of communications-based train control (CBTC). Drawing from the safety principles, analysis methods, and risk assessments of CBTC systems, comparable functional subsystem definitions are proposed for AV fleets in driverless operation. With the prospect of multiple AV fleets operating within a single automated mobility district, the criticality of protecting roadway junctions requires an approach like that of automated fixed-guideway transit systems, in which a guideway switch zone "interlocking" at each junction location deconflicts railway traffic, affirming safe passage. The analogous AV protection safety subsystem is defined as fail-safe equipment that monitors roadway intersections and junctions, communicates traffic signal status, perceives and communicates alerts and signals to AV connected vehicles concerning potential unsafe conditions, and performs related primary safety functions. Conclusions are drawn that the AV protection roadway intersection functions must be performed by local roadside equipment dedicated to protecting each roadway intersection and junction. Further, it is concluded that the communications technology connecting the infrastructure with the vehicle to perform this vital, fail-safe protection should meet specific functional and performance criteria.

33 ADVANCED PROPULSION SYSTEMS↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

An Advanced Microscopic Energy Consumption Model for Automated Vehicle:Development, Calibration, Verification

The automated vehicle (AV) equipped with the Adaptive Cruise Control (ACC) system is expected to reduce the fuel consumption for the intelligent transportation system. This paper presents the Advanced ACC-Micro (AA-Micro) model, a new energy consumption model based on micro trajectory data, calibrated and verified by empirical data. Utilizing a commercial AV equipped with the ACC system as the test platform, experiments were conducted at the Columbus 151 Speedway, capturing data from multiple ACC and Human-Driven (HV) test runs. The calibrated AA-Micro model integrates features from traditional energy consumption models and demonstrates superior goodness of fit, achieving an impressive 90% accuracy in predicting ACC system energy consumption without overfitting. A comprehensive statistical evaluation of the AA-Micro model's applicability and adaptability in predicting energy consumption and vehicle trajectories indicated strong model consistency and reliability for ACC vehicles, evidenced by minimal variance in RMSE values and uniform RSS distributions. Conversely, significant discrepancies were observed when applying the model to HV data, underscoring the necessity for specialized models to accurately predict energy consumption for HV and ACC systems, potentially due to their distinct energy consumption characteristics.

Ma, Ke↗

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Object-Oriented Controllable High-Resolution Residential Energy (OCHRE) (TM) Model

This presentation describes the OCHRE model as part of NREL's Powered By webinar series. OCHRE is a building energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, electric vehicles, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Integration of Utility Distributed Energy Resource Management System and Aggregators for Evolving Distribution System Operators

With the rapid integration of distributed energy resources (DERs), distribution utilities are faced with new and unprecedented issues. New challenges introduced by high penetration of DERs range from poor observability to overload and reverse power flow problems, under-over-voltages, maloperation of legacy protection systems, and requirements for new planning procedures. Distribution utility personnel are not adequately trained, and legacy control centers are not properly equipped to cope with these issues. Fortunately, distribution energy resource management systems (DERMSs) are emerging software technologies aimed to provide distribution system operators (DSOs) with a specialized set of tools to enable them to overcome the issues caused by DERs and to maximize the benefits of the presence of high penetration of these novel resources. However, as DERMS technology is still emerging, its definition is vague and can refer to very different levels of software hierarchies, spanning from decentralized virtual power plants to DER aggregators and fully centralized enterprise systems (called utility DERMS). Although they are all frequently simply called DERMS, these software technologies have different sets of tools and aim to provide different services to different stakeholders. This paper explores how these different software technologies can complement each other, and how they can provide significant benefits to DSOs in enabling them to successfully manage evolving distribution networks with high penetration of DERs when they are integrated together into the control centers of distribution utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVSE DERMS Controls [SWR-26-010]

An MQTT (Message Queuing Telemetry Transport) and OCPP (Open Charge Point Protocol) based remote smart charging controller framework for AC Electric Vehicle Supply Equipments (EVSEs). The code in this repo allows for the National Laboratory of the Rockies (NLR) controls to interface with the real Distributed Energy Resource Management System (DERMS) and EVSEs in NLR's ESIF Optimization and Control Laboratory (OCL). Different charge management algorithms can be tested to determine which power allocation method is most effective with the overall goal of demonstrating clear and well documented test results as well as providing functional control algorithms which could be utilized to provide effective smart charge management (SCM) at EV charging stations. Different power allocation methods are programmed in lab_demo_controller.py and include allocation based on first come first served, equal sharing, state of charge (SOC), priority factors, and behind the meter control methods.

Panossian, Nadia [National Laboratory of the Rocki↗

Simulation of Mechanical Fractionation of Chopped Whole-Plant Corn (WPC) Using Discrete Element Method (DEM)

Fractionating whole-plant corn (WPC) in a single-pass harvesting system requires studies on the WPC-to-equipment interaction for improved property control, as well as mechanical and air-driven separation processes compared to the traditional multi-pass grain and stover harvesting system. The discrete element method (DEM) technique has the potential to simulate WPC mechanical fractionation and support simulation-based design of WPC separation processes. In this study, methods to develop DEM particle models of WPC (kernel, cob, stalk, and husk) and their material properties for simulating mass fractionation using the ASABE standard mechanical shaker were proposed. Measurement was done on the axial dimensions (major, intermediate, and minor) and mass of each WPC type (mean sample size is 56), sampled from single-pass harvesting. Applying gaussian multivariate regression and bootstrapping re-sampling techniques, a DEM particle approximate to each WPC was developed. Sensitivity analysis of the DEM Young‘s modulus, Poisson‘s ratio, and interaction parameters of coefficient of restitution, coefficient of rolling friction, and coefficient of static friction on mass fraction was performed after 156 ASABE sieve-shaking DEM simulation runs, generated using Latin Hypercube Design (LHD) design of experiment (DOE) from 19 DEM material parameters. DEM simulation using Hertz-Mindlin with flexible bond contact laws and DOE optimized material properties successfully reproduced the mass fractions retained in ASABE sieves at 9.8% mean relative error and a coefficient of determination of R2 = 0.87. Here, the DEM methodology developed for mechanical WPC mass fractionation could be deployed to perform virtual design of feedstock handling equipment and performance analysis of mechanical fraction systems.

09 BIOMASS FUELS↗

Evaluation of Curtailment Associated with PV System Design Considerations

Distributed photovoltaic (PV) systems equipped with advanced inverters can control real and reactive power output based on grid and atmospheric conditions. The Volt-Var control method allows inverters to regulate local grid voltages by producing or consuming reactive power. Based on their power ratings, the inverters may need to curtail real power to meet the reactive power requirements, which decreases their total energy production. To evaluate the expected curtailment associated with Volt-Var control, yearlong quasi-static time-series (QSTS) simulations were conducted on a realistic distribution feeder under a variety of PV system design considerations. Overall, this paper found that the amount of curtailed energy is low (<; 0.55%) compared to the total PV energy production in a year but is affected by several PV system design considerations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Validation of the Fault Ride-Through Response of a Generic EMT Inverter Model by Laboratory Testing

This paper presents the validation of the fault ride-through response of a large-scale inverter model using laboratory testing of a commercial inverter. First, we present the generic inverter model specifications. The generic inverter control is developed based on the fault ride-through response performance requirements of IEEE Std 2800-2022 for inverter-based resources. Next, we present laboratory tests that emulate voltages at the inverter terminal resulting from balanced and unbalanced faults on the transmission system. The tests are performed on a commercia12.2 MVA battery storage inverter at the U.S. National Renewable Energy Laboratory. Comparisons of the model's response to the laboratory measurements show the generic model presented can predict the controlled response of the commercial equipment. The differences between the model's response and the laboratory measurements during the initial transient at fault inception are discussed.

fault ride-through↗

Cobalt-Free Cathodes for Next Generation Li-Ion Batteries

In this U.S. Department of Energy sponsored project Nexceris, in collaboration with project partners; The Ohio State University and Navitas Advanced Systems have advanced the technical maturity of a non-cobalt containing cathode for next-generation Li-ion batteries. The cathode is based on the lithium manganese nickel-titanium oxide, LiNi 0.5 Mn 1.5 TiO 4 (LNMTO) high voltage spinel. To address limitations with poor cycle and calendar life an microstucturally hierarchical LNMO/LNMTO core-shell cathode powder has been developed that enables the formation of a solid-electrolyte interface that effectively passivates the cathode surface. The microstructural enhancements of the cathode material focus on preferentially enriching the surface with titanium. In parallel, new, optimized binder and electrolyte chemistries have been incorporated to address degradation mechanisms associated with high-voltage systems. Single-layer pouch cell and large-format 2-Ah cell testing have shown that an optimized LNMO/LNMTO core-shell powder significantly improves initial cell capacity and cycle life compared to homogeneous LNMO powder. To support development and the fabrication of 2-Ah cells a novel Hybrid Alternative Wet-Chemical Synthesis (HAWCS) process have been developed. This low-cost, synthesis approach enables the excellent compositional and particle morphology control achieved with co-precipitation without the strict process controls and associated expensive process equipment.

25 ENERGY STORAGE↗

Flexible Fuel Electric Hybrid Glass Furnace Demonstration

The furnace contractor completed General Arrangement (GA) layouts and Piping and Instrumentation Diagrams (P&ID) for both furnaces during this reporting period. Preliminary equipment lists accompanied this work. Control system architecture in progress. Key furnace design elements and deliverables on track to be complete by end of phase. The facilities design and integration contractor completed a 3D scan and modeling of the facility. The work during this period focused on preliminary design with a focus on overall project scope and feasibility. This key work supports the overall project deliverables for 30% preliminary engineering and Preliminary Design Report (PDR) which are on track to be complete by the end of the phase. These deliverables are approximately 50% complete through the end of this reporting period. The batch house operations design contractor continues development of site plan and General Arrangement (GA) layout to support the 30% preliminary engineering and design package. This work is 60% complete by the end of this reporting period and is on track to be complete by the end of the phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online characterization of primary and secondary emissions of particulate matter and acidic molecules from a modern fleet of city buses

The potential impact of transitioning from conventional fossil fuel to a non-fossil-fuel vehicle fleet was investigated by measuring primary emissions via extractive sampling of bus plumes and assessing secondary mass formation using the Gothenburg Potential Aerosol Mass (Go:PAM) reactor from 76 in-use transit buses. Online chemical characterization of gaseous and particulate emissions from these buses was conducted using chemical ionization mass spectrometry (CIMS) with acetate as the reagent ion, coupled with the Filter Inlet for Gases and AEROsols (FIGAERO). Acetate reagent ion chemistry selectively ionizes acidic compounds, including organic and inorganic acids, as well as nitrated and sulfated organics. A significant reduction (48 %–98 %) in fresh particle emissions was observed in buses utilizing compressed natural gas (CNG), biodiesels like rapeseed methyl ester (RME) and hydrotreated vegetable oil (HVO), and hybrid-electric HVO (HVO HEV ) compared to diesel (DSL). However, secondary particle formation from photooxidation of emissions was substantial across all the fuel types. The median ratio of particle mass emission factors of aged to fresh emissions increased in the following order: DSL buses at 4.0, HVO buses at 6.7, HVO HEV buses at 10.5, RME buses at 10.8, and CNG buses at 84. Of the compounds that can be identified by CIMS, fresh gaseous emissions from all Euro V/EEV (Enhanced Environmentally friendly Vehicle) buses, regardless of fuel type, were dominated by nitrogen-containing compounds such as nitrous acid (HONO), nitric acid (HNO 3 ), and isocyanic acid (HNCO), alongside small monoacids (C 1 –C 3 ). Notably, the emission of nitrogen-containing compounds was lower in Euro VI buses equipped with more advanced emission control technologies. Secondary gaseous organic acids correlated strongly with gaseous HNO 3 signals (R 2 =0.85–0.99) in Go:PAM, but their moderate to weak correlations with post-photooxidation secondary particle mass suggest that they are not reliable tracers of secondary organic aerosol formation from bus exhaust. Our study highlights that non-regulated compounds and secondary pollutant formation, not currently addressed in legislation, are crucial considerations in the evaluation of environmental impacts of future fuel and engine technology shifts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗