At least 145 records · Page 8

Development of Short-Term Forecasting Models Using Plant Asset Data and Feature Selection

Nuclear power plants collect and store large volumes of heterogeneous data from various components and systems. With recent advances in machine learning (ML) techniques, these data can be leveraged to develop diagnostic and short-term forecasting models to better predict future equipment condition. Maintenance operations can then be planned in advance whenever degraded performance is predicted, thus resulting in fewer unplanned outages and the optimization of maintenance activities. This enables lower maintenance costs and improves the overall economics of nuclear power. This paper focuses on developing a short-term forecasting process that leverages a feature selection process to distill large volumes of heterogeneous data and predict specific equipment parameters. A variety of feature selection methods, including Shapley Additive Explanations (SHAP) and variance inflation factor (VIF), were used to select the optimal features as inputs for three ML methods: long short-term memory (LSTM) networks, support vector regression (SVR), and random forest (RF). Each combination of model and input features was used to predict a pump bearing temperature both 1 and 24 hours in advance, based on actual plant system data. The optimal inputs for the LSTM and SVR were selected using the SHAP values, while the optimal input for the RF consisted solely of the response variable itself. Each model produced similar 1-hour-ahead predictions, with root mean square errors (RMSEs) of roughly 0.006. For the 24-hour-ahead predictions, differences could be seen between LSTM, SVR, and RF, as reflected by model performances of 0.036 +- 0.014, 0.0026 +- 0, and 0.063 +- 0.004 RMSE, respectively. As big data and continuous online monitoring become more widely available, the proposed feature selection process can be used for many applications beyond the prediction of process parameters within nuclear infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An intelligent advisory system for pre-launch processing

The shuttle system of interest in this paper is the shuttle's data processing system (DPS). The DPS is composed of the following: (1) general purpose computers (GPC); (2) a multifunction CRT display system (MCDS); (3) mass memory units (MMU); and (4) a multiplexer/demultiplexer (MDM) and related software. In order to ensure the correct functioning of shuttle systems, some level of automatic error detection has been incorporated into all shuttle systems. For the DPS, error detection equipment has been incorporated into all of its subsystems. The automated diagnostic system, (MCDS) diagnostic tool, that aids in a more efficient processing of the DPS is described.

Engrand, Peter A.↗

Assessment of ProgPy - An Open-Source Condition Monitoring and Diagnostics Tool

Traditional maintenance programs, such as corrective and preventive strategies, may lead to high costs and operational inefficiencies. Condition Monitoring and Diagnostics (CM&D) aims to improve these maintenance strategies by enabling timely insights into equipment health and performance. However, implementation of CM&D can be challenging without a robust framework that manages data efficiently, supports interoperability and simplifies integration. To address these challenges ProgPy, an open-source Python-based prognostics tool developed by NASA Ames Research Center, offers a structured solution for broader Prognostics and Health Management (PHM) applications. Ongoing research is assessing the feasibility of implementing ProgPy as a Condition Monitoring and Diagnostics (CM&D) solution by comparing its framework to the guidelines for open CM&D systems recommended in the ISO 13374-2 standard. This evaluation aims to highlight ProgPy’s strengths and identify opportunities for improvement, thereby, contributing to its advancement as an effective tool for Prognostics and Health Management (PHM). This paper presents the results of an initial assessment of the ProgPy toolbox through a gearbox case study using open-source datasets.

Condition-Monitoring, Diagnostics, Failure, Gearbo↗

Revealing the three-dimensional structure of microbunched plasma-wakefield-accelerated electron beams

Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high- Z gas-target dopants or by uncontrolled laser–plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators.

43 PARTICLE ACCELERATORS↗

Early experiments in charged particle beams from the Space Shuttle

Characteristics of studies on board the Shuttle involving the interaction of particle beams with the atmosphere and the ionosphere, and the effects of the beams on the electrical potential of the platform, are discussed. Noting that the Shuttle allows greater weight and power demands by scientific payloads than previous satellite launches, the OSS-1 Vehicle Charging and Potential experiment and the Spacelab 1 Particle Accelerator and Phenomena Induced by Charged Particle Beams are described. Instrumentation details are provided, including charge and current probes, the Spherical Retarding Potential Analyzer, the Fast Pulse Electron Generator, and digital control and interface units. The SEPAC equipment, which comprises an electron beam accelerator, and MPD plasma jet, and diagnostic units are detailed, and operating procedures and experiment objectives are outlined.

Raitt, W. J.↗

ELF waves and ion resonances produced by an electron beam emitting rocket in the ionosphere

Results are reported from the ECHO-6 electron-beam-injection experiment, performed in the auroral-zone ionosphere on March 30, 1983 using a sounding rocket equipped with two electron guns and a free-flying plasma-diagnostics instrument package. The data are presented in extensive graphs and diagrams and characterized in detail. Large ELF wave variations, superposed on the strong beam-sector-directed quasi-dc component, are observed in the 100-eV beam-induced plasma when the beam is injected in a transverse spiral, but not when it is injected upward parallel to the magnetic-field line. ELF activity is found to be suppressed whenever the rocket passed through field lines with auroral activity, suggesting that the waves are produced by the interaction of the beam potentials, plasma currents, and return currents neutralizing the accelerator payload.

Winckler, J. R.↗

The Buffer Diagnostic Prototype: A fault isolation application using CLIPS

This paper describes problem domain characteristics and development experiences from using CLIPS 6.0 in a proof-of-concept troubleshooting application called the Buffer Diagnostic Prototype. The problem domain is a large digital communications subsystems called the real-time network (RTN), which was designed to upgrade the launch processing system used for shuttle support at KSC. The RTN enables up to 255 computers to share 50,000 data points with millisecond response times. The RTN's extensive built-in test capability but lack of any automatic fault isolation capability presents a unique opportunity for a diagnostic expert system application. The Buffer Diagnostic Prototype addresses RTN diagnosis with a multiple strategy approach. A novel technique called 'faulty causality' employs inexact qualitative models to process test results. Experimental knowledge provides a capability to recognize symptom-fault associations. The implementation utilizes rule-based and procedural programming techniques, including a goal-directed control structure and simple text-based generic user interface that may be reusable for other rapid prototyping applications. Although limited in scope, this project demonstrates a diagnostic approach that may be adapted to troubleshoot a broad range of equipment.

Porter, Ken↗

Reconstruction of tokamak plasma safety factor profile using deep learning

Abstract The motional Stark effect (MSE) diagnostic has been a standard measurement for the magnetic field line pitch angle in tokamaks that are equipped with neutral beams. However, the MSE data are not always available due to experimental constraints, especially in future devices without neutral beams. Here we develop a deep-learning based model (SGTC-QR) that can reconstruct the safety factor profile without the MSE diagnostic to mimic the traditional equilibrium reconstruction with the MSE constraint. The model demonstrates promising performance, and the sub-millisecond inference time is compatible with the real-time plasma control system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Smart Sensors Gather Information for Machine Diagnostics

Stennis Space Center was interested in using smart sensors to monitor components on test stands and avert equipment failures. Partnering with St. Paul, Minnesota-based Lion Precision through a Cooperative Agreement, the team developed a smart sensor and the associated communication protocols. The same sensor is now commercially available for manufacturing.

Source record↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Paranoia.Ada: A diagnostic program to evaluate Ada floating-point arithmetic

Many essential software functions in the mission critical computer resource application domain depend on floating point arithmetic. Numerically intensive functions associated with the Space Station project, such as emphemeris generation or the implementation of Kalman filters, are likely to employ the floating point facilities of Ada. Paranoia.Ada appears to be a valuabe program to insure that Ada environments and their underlying hardware exhibit the precision and correctness required to satisfy mission computational requirements. As a diagnostic tool, Paranoia.Ada reveals many essential characteristics of an Ada floating point implementation. Equipped with such knowledge, programmers need not tremble before the complex task of floating point computation.

Hjermstad, Chris↗

Dust-Tolerant Intelligent Electrical Connection System

Faults in wiring systems are a serious concern for the aerospace and aeronautic (commercial, military, and civilian) industries. Circuit failures and vehicle accidents have occurred and have been attributed to faulty wiring created by open and/or short circuits. Often, such circuit failures occur due to vibration during vehicle launch or operation. Therefore, developing non-intrusive fault-tolerant techniques is necessary to detect circuit faults and automatically route signals through alternate recovery paths while the vehicle or lunar surface systems equipment is in operation. Electrical connector concepts combining dust mitigation strategies and cable diagnostic technologies have significant application for lunar and Martian surface systems, as well as for dusty terrestrial applications. The dust-tolerant intelligent electrical connection system has several novel concepts and unique features. It combines intelligent cable diagnostics (health monitoring) and automatic circuit routing capabilities into a dust-tolerant electrical umbilical. It retrofits a clamshell protective dust cover to an existing connector for reduced gravity operation, and features a universal connector housing with three styles of dust protection: inverted cap, rotating cap, and clamshell. It uses a self-healing membrane as a dust barrier for electrical connectors where required, while also combining lotus leaf technology for applications where a dust-resistant coating providing low surface tension is needed to mitigate Van der Waals forces, thereby disallowing dust particle adhesion to connector surfaces. It also permits using a ruggedized iris mechanism with an embedded electrodynamic dust shield as a dust barrier for electrical connectors where required.

Lewis, Mark↗

Long and Winding Road to Higher Efficiency-The RTU Story: Preprint

Rooftop units (RTUs) and other packaged heating, ventilating, and air-conditioning (HVAC) equipment consume more than four quads of energy annually while conditioning more than 50% of the commercial building floor area in the United States. Historically, these systems have low operating efficiencies and receive infrequent maintenance. In addition, the market has a low first cost, run-to-failure, like-for-like replacement mentality and has been slow to adopt change. This paper explores the broad market transformation that has resulted in higher efficiencies and tremendous energy savings. Although there are many factors in this market transformation, this paper highlights: research behind advancements in components and controls; adoption of an operational efficiency metric; raising the bar for high efficiency with the RTU Challenge; market barriers overcome through the Advanced RTU Campaign; upstream and midstream incentive programs and HVAC distribution networks; alignment of the market efficiency drivers of ASHRAE Standard 90.1, federal minimum efficiency standards, the ENERGY STAR® program, and the Consortium for Energy Efficiency's (CEE's) efficiency tiers. Measures of the market transformation include more than 50% increase in RTU efficiencies, more than 1 billion kWh saved and 160,000 RTUs upgraded with high-efficiency measures by the Advanced RTU Campaign partners, large increases of high-efficiency RTUs purchased through incentive programs, and the largest energy savings from any federal minimum standards action. Although these results are impressive, the market transformation is just beginning, and there remain exciting opportunities for improvements in equipment efficiencies and improved operating performance with advanced controls and fault detection and diagnostics.

30 DIRECT ENERGY CONVERSION↗

Singleplex, multiplex and pooled sample real-time RT-PCR assays for detection of SARS-CoV-2 in an occupational medicine setting

Abstract For workplaces which cannot operate as telework or remotely, there is a critical need for routine occupational SARS-CoV-2 diagnostic testing. Although diagnostic tests including the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (CDC Diagnostic Panel) (EUA200001) were made available early in the pandemic, resource scarcity and high demand for reagents and equipment necessitated priority of symptomatic patients. There is a clearly defined need for flexible testing methodologies and strategies with rapid turnaround of results for (1) symptomatic, (2) asymptomatic with high-risk exposures and (3) asymptomatic populations without preexisting conditions for routine screening to address the needs of an on-site work force. We developed a distinct SARS-CoV-2 diagnostic assay based on the original CDC Diagnostic Panel (EUA200001), yet, with minimum overlap for currently employed reagents to eliminate direct competition for limited resources. As the pandemic progressed with testing loads increasing, we modified the assay to include 5-sample pooling and amplicon target multiplexing. Analytical sensitivity of the pooled and multiplexed assays was rigorously tested with contrived positive samples in realistic patient backgrounds. Assay performance was determined with clinical samples previously assessed with an FDA authorized assay. Throughout the pandemic we successfully tested symptomatic, known contact and travelers within our occupational population with a ~ 24–48-h turnaround time to limit the spread of COVID-19 in the workplace. Our singleplex assay had a detection limit of 31.25 copies per reaction. The three-color multiplexed assay maintained similar sensitivity to the singleplex assay, while tripling the throughput. The pooling assay further increased the throughput to five-fold the singleplex assay, albeit with a subtle loss of sensitivity. We subsequently developed a hybrid ‘multiplex-pooled’ strategy to testing to address the need for both rapid analysis of samples from personnel at high risk of COVID infection and routine screening. Herein, our SARS-CoV-2 assays specifically address the needs of occupational healthcare for both rapid analysis of personnel at high-risk of infection and routine screening that is essential for controlling COVID-19 disease transmission. In addition to SARS-CoV-2 and COVID-19, this work demonstrates successful flexible assays developments and deployments with implications for emerging highly transmissible diseases and future pandemics.

60 APPLIED LIFE SCIENCES↗

Photovoltaic test and demonstration project

The primary objectives of the Photovoltaic Test and Demonstration Project are: (1) to determine operating characteristics for different solar cell systems and subsystems, (2) to prove, through tests and demonstrations, that solar cell systems can satisfy the requirements of potentially attractive residential, commercial, industrial, and smaller terrestrial applications, (3) to devise and implement the methodology, techniques and equipment to make accurate and reproducible measurements of solar cell and array performance, and diagnostic measurements on solar cells, modules and arrays, and (4) to determine the endurance of solar cell modules, component parts, and materials under expected environmental conditions.

Forestieri, A. F.↗

Cooperating Expert Systems For Automated Monitoring And Diagnostics

Human operators freer to perform nonrepetitive tasks. Expert software system for monitoring multiple streams of sensory data from interacting equipment subsystems undergoing development. Organized hierarchically to monitor multiple equipment subsystems simultaneously. Each expert software subsystem responsible for one of equipment subsystems. Intended to assist human analysts in interpretation of telemetry data indicating operating statuses of subsystems of spacecraft, enables analysts to maintain desired mode(s) of operation, and helps to correct anomalies in subsystems or in overall spacecraft system. Other versions devised for industrial monitoring and analysis tasks similarly complicated.

Schwuttke, Ursula M.↗

A Fiber Optic Probe for Monitoring Protein Aggregation, Nucleation, and Crystallization

Protein crystals are experimentally grown in hanging drops in microgravity experiments on-board the Space Shuttle orbiter. The technique of dynamic light scattering (DLS) can be used to monitor crystal growth process in hanging droplets (approx. 30 (L)) in microgravity experiments, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. In this paper we demonstrate that such experiments are now feasible. We apply a newly developed fiber optic probe to various earth and space (micro- gravity) bound protein crystallization system configurations to test its capability. These include conventional batch (cuvette or capillary) systems, hanging drop method in a six-pack hanging drop vapor diffusion apparatus (HDVDA), a modified HDVDA for temperature- induced nucleation and aggregation studies, and a newly envisioned dynamically controlled vapor diffusion system (DCVDS) configuration. Our compact system exploits the principles of DLS and offers a fast (within a few seconds) means of quantitatively and non-invasively monitoring the various growth stages of protein crystallization. In addition to DLS capability, the probe can also be used for performing single-angle static light scattering measurements. It utilizes extremely low levels of laser power (approx. few (W)) without a need of having any optical alignment and vibration isolation. The compact probe is also equipped with a miniaturized microscope for visualization of macroscopic protein crystals. This new optical diagnostic system opens up enormous opportunity for exploring new ways to grow good quality crystals suitable for x-ray crystallographic analysis and may help develop a concrete scientific basis for understanding the process of crystallization.