Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Center Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simulation of the Infrared Astronomical Satellite /IRAS/ telescope system

The Infrared Astronomical Satellite (IRAS), a joint Dutch-British-U.S. project scheduled for launch in February 1981, will conduct the first all-sky infrared survey between 8 and 120 microns using a 60-cm aperture, cryogenically-cooled telescope. A computer simulation program has been developed at Ames Research Center to aid in the design of this complex telescope. The development and implementation of the IRAS Telescope Simulator (IRTS), its input data sources, and its output data products are described.

Henderson, E.↗

Exit Presentation

Skills Acquired: Tensile Testing: Prepare materials and setting up the tensile tests; Collect and interpret (messy) data. Outgassing Testing: Understand TML (Total Mass Loss) and CVCM (Collected Volatile Condensable Material); Collaboration with other NASA centers. Z2 (NASA's Prototype Space Suit Development) Support: Hands on building mockups of components; Analyze data; Work with others, understanding what both parties need in order to make a run successful. LCVG (Liquid Cooling and Ventilation Garment) Flush and Purge Console: Both formal design and design review process; How to determine which components to use - flow calculations, pressure ratings, size, etc.; Hazard Analysis; How to make design tradeoffs.

Melone, Kate↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infrared radiative properties of tropical cirrus clouds inferred with aircraft measurements

Longwave emissivities and the vertical profile of cooling rates of tropical cirrus clouds are determined using broadband hemispheric irradiance data. Additionally, a broadband mass absorption coefficient is defined and used to relate emissivity to water content. The data used were collected by the National Center for Atmospheric Research (NCAR) Sabreliner during the GARP Atlantic Tropical Experiment (GATE) in the summer of 1974. Three case studies are analyzed showing that these tropical cirrus clouds approached an emissivity of 1.0 within a vertical distance of 1.0 km. Broadband mass absorption coefficients ranging from 0.076 to 0.096 sq m per g are derived. A comparison of these results with other work suggests that tropical cirrus cloud emissivities may be significantly larger than heretofore believed. Ice water content of the clouds were deduced from data collected by a one-dimensional particle spectrometer. Analyses of the ice water content and the observed particle size distributions are presented.

Griffith, K. T.↗

Cryogenic Flow Boiling Parabolic Flight Experiment and Universal Correlations for Cryogens

Cryogenic fluids are employed in many industries and play crucial roles in space applications, including nuclear thermal propulsion systems, LOX/LCH4 ascent and descent stage feedlines, LOX/LH2 transfer lines for in-space fuel depots, and LHe transfer lines that cool space experiments. Due to the ultra-low boiling point of cryogens, phase change is inevitable in these systems, which leads to complex boiling behavior in reduced gravity. For cost-effective design and sizing of the aforementioned systems, accurate knowledge of two-phase parameters such as pressure drop, heat transfer coefficient (HTC), and critical heat flux (CHF) is desired. Since 2018, researchers from Purdue University and NASA Glenn Research Center (GRC) have been collaborating to investigate the effects of reduced gravity on cryogenic pool boiling, flow boiling ins tubes, and spray cooling. Using a variety of both terrestrial and parabolic flight experimental rigs, extensive LN2 data have been amassed and combined with cryogenic data from World literature to develop both ‘universal’ empirical correlations and CFD models, which are expected to serve as foundation for design of future space systems involving cryogenic fluids. This presentation will provide an overview of both the experimental work and predictive tools that have resulted from the joined Purdue-Glenn studies.

Flow Boiling↗

Infrared atlas charts of the eclipsed moon.

The objective of this atlas is to present the thermal response of the lunar surface observed during an eclipse of the moon with accurate position data. The observations were made at a wavelength of 11 microns with an angular resolution of 10 sec, equivalent to 17 km at the disk center. Over a thousand thermally anomalous regions (hot spots) were detected. They cool more slowly than their environs and remain warmer than their environs during the umbral phase. In addition to these very localized hot spots, some of the maria show thermal enhancements during the eclipse. Fourty four charts make up this atlas which are identical in coverage and projection to the Lunar Atlas Charts (LAC) series. The charts are in the form of digital images of a normalized temperature difference which is particularly useful for studying regions of small thermal enhancements. Each increase of intensity corresponds to a 4 K temperature increase.

Shorthill, R. W.↗

Conducting Research on the International Space Station Using the EXPRESS Rack Facilities

Conducting Research on the International Space Station using the EXPRESS Rack Facilities. Sean W. Thompson and Robert E. Lake. NASA Marshall Space Flight Center, Huntsville, AL, USA. Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling (500 W) for two locations, one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.

Thompson, Sean W.↗

Cataclysmic variable evolution - Clues from the underlying white dwarf

This paper presents an update of determinations of the CV white dwarf effective-temperature, T(eff), together with an initial exploration of the possible implications and constraints on the CV lifetimes and evolution based on the ensemble of white dwarf T(eff) values as a function of orbital period. The CV dwarf luminosities are derived by using the T(eff) data and adopting the masses of individual CV white dwarfs determined by Webbink (1990). The present ensemble of empirically determined white dwarf effective temperatures reveals a distribution centered near 16,000 K, implying a mean lower limit total cooling lifetime of 5 x 10 to the 8th yr for the majority of CV degenerates. The two coolest CV degenerates, VV Puppis and St LMi, were found among the strongly magnetic AM Her CVs.

Sion, Edward M.↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.↗

Projected Applications of a "Climate in a Box" Computing System at the NASA Short-Term Prediction Research and Transition (SPoRT) Center

The NASA Short-term Prediction Research and Transition (SPoRT) Center focuses on the transition of unique observations and research capabilities to the operational weather community, with a goal of improving short-term forecasts on a regional scale. Advances in research computing have lead to "Climate in a Box" systems, with hardware configurations capable of producing high resolution, near real-time weather forecasts, but with footprints, power, and cooling requirements that are comparable to desktop systems. The SPoRT Center has developed several capabilities for incorporating unique NASA research capabilities and observations with real-time weather forecasts. Planned utilization includes the development of a fully-cycled data assimilation system used to drive 36-48 hour forecasts produced by the NASA Unified version of the Weather Research and Forecasting (WRF) model (NU-WRF). The horsepower provided by the "Climate in a Box" system is expected to facilitate the assimilation of vertical profiles of temperature and moisture provided by the Atmospheric Infrared Sounder (AIRS) aboard the NASA Aqua satellite. In addition, the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments aboard NASA s Aqua and Terra satellites provide high-resolution sea surface temperatures and vegetation characteristics. The development of MODIS normalized difference vegetation index (NVDI) composites for use within the NASA Land Information System (LIS) will assist in the characterization of vegetation, and subsequently the surface albedo and processes related to soil moisture. Through application of satellite simulators, NASA satellite instruments can be used to examine forecast model errors in cloud cover and other characteristics. Through the aforementioned application of the "Climate in a Box" system and NU-WRF capabilities, an end goal is the establishment of a real-time forecast system that fully integrates modeling and analysis capabilities developed within the NASA SPoRT Center, with benefits provided to the operational forecasting community.

Jedlovec, Gary J.↗

ERDA/NASA-MSFC solar heating and cooling development and demonstration program

The role of the Manned Space Flight Center (MSFC) in the National Solar Heating and Cooling program is evaluated. The responsibilities of the MSFC within this program are (1) to manage the development and testing of solar heating and cooling systems leading to marketable products, (2) to develop data acquisition equipment supporting a national data program, and (3) to manage and collect data from commercial demonstration sites. MSFC test facilities and demonstration sites are described.

Price, J. M.↗

municipal recreation center is heated and cooled by solar energy

Major fraction of energy requirements for community building is ksupplied by Sun. The 238 flat plate solar collectors are roof mounted on single story structure enclosing gymnasium, locker area, and health care clinic; heat exchanger transfers collected energy to 6,000 gallon storage tank. Final report chronicles project from inception to completion, documenting performance, costs, operating modes, and data acquisition system. Appendix contains manufacturers' product literature and engineering drawings.

Source record↗

A 2 kiloparsec accretion disk (?) inside a 17 kiloparsec H-alpha bar in the cooling flow cluster 2A 0335+096

Observations of the central region of the galaxy cluster associated with 2A 0335+096, obtained in H-alpha, R, I, and b45 (4506 A with FWHM 355 A) using an 800 x 800-pixel CCD detector on the 4-m telescope at KPNO on December 27 and 30, 1986, are reported. The data are presented graphically and analyzed. Features discussed include a 17-kpc-long bar of H-alpha emission surrounded by filaments, a smaller elongated H-alpha structure (possibly an accretion disk) centered on the nucleus of the central galaxy, a secondary galaxy with a red H-alpha-bright nucleus located within the 17-kpc bar about 6 arcsec from the central-galaxy nucleus, and evidence for excess blue emission (indicating star formation at about 8 solar mass/yr in the cooling flow). From the presence of dust in the emission-line gas it is inferred that theoretical models based on preferential formation of low-mass stars may not be applicable to this object.

Romanishin, W.↗

Opportunities for Using the Industrial Assessment Center Database for Industrial Water Use Analysis

The manufacturing sector accounted for approximately 5–6% of total U.S. water use in 2015. Of that amount, 75–80% is self supplied withdrawal from surface-water and groundwater sources and the remainder is from public water supplies. Although manufacturing facilities commonly locate in water-scarce areas, water scarcity still poses a great risk to the manufacturing sector. Reliable water is necessary for any facility that relies on it for process and comfort cooling, cleaning, employee use, and steam generation. One of these barriers to water efficiency is the lack of reliable data on overall U.S. industrial water use—how it is used and the quantities required for each sector. If a facility cannot be easily compared with a facility of similar size and sector, knowing if it is effectively using water conservation best practices is difficult. One potential source of industrial water use data is the U.S. Department of Energy (DOE)–sponsored Industrial Assessment Centers (IACs). IACs are university-based organizations that provide free audits to small- and medium-sized manufacturing facilities to identify productivity improvement and waste and energy reduction opportunities. The IACs also maintain a database of all the audits conducted, which currently holds more than 19,267 assessments and 145,000 recommendations (as of July 24, 2020). This database also contains energy utility (electricity, natural gas, and other fuels) and water utility data, making it a potential data source for industrial water use. This report attempts to create regression models to predict a small- or medium-sized industrial facility’s annual water use or cost based on its industrial subsector and several possible relevant variables. Using data collected by IAC assessments, models for several industrial subsectors were generated via stepwise regression techniques to determine which variables (annual sales, number of employees, facility/plant area, annual production hours, and a water stress metric) are relevant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Satellite observations of upper atmosphere O3 and HNO3 from the Limb Infrared Monitor of the Stratosphere /LIMS/ experiment on Nimbus 7

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment, launched on-board the Nimbus satellite, was designed to measure both day and night limb radiance which is used to infer upper atmosphere temperature profiles and chemical compound concentrations important in the study of ozone chemistry. The LIMS instrument is a six channel, limb scanning, thermal radiometer which uses HgCdTe detectors, cooled to approximately 64 K. Measurements include ozone, water vapor, nitrogen dioxide, and nitric acid. The ozone and nitric acid channels are centered at approximately 9.6 microns and 11.3 microns, respectively. Results from the channels are described with an emphasis on data validation. The O3 and HNO3 channels have demonstrated high measurement precision.

Russell, J. M., III↗

A millimeter-wave anisotropy experiment (MAX) to search for anisotropy in the cosmic background radiation on medium angular scales

We report preliminary results from two balloon flights of a millimeter-wave telescope designed to measure anisotropy in the cosmic microwave background (CMB) on angular scales from 0.3 to 3 degrees. The receiver used in the first flight, in November 1989, was a dichroic, He-3-cooled bolometric photometer with passbands centered at 3, 6, 9, and 12/cm. The second flight, in July 1990, employed improved bolometric detectors. The 3/cm band was removed in order to increase the efficiency of the remaining bands. Preliminary analysis of the data gives a factor of 3 improvement in sensitivity over the first flight in the 6/cm band. Future plans include a new receiver to provide an additional factor of 5 improvement in sensitivity and a new balloon-borne telescope which is optimized for low-background bolometric detectors at millimeter wavelengths.

Fischer, M. L.↗

Development of computer models for correlating data of film cooling of nose cone under hypersonic flow

A 12.5 degree half cone with tangential slot injection at Mach 6.95 was studied to determine the heating rates to the surface of the body near and far downstream of the slot. The cone had a zero degree angle of attack. The heating rates were obtained using a computer program that was developed at NASA-Langley Research Center. The concentration of nitrogen from the slot into the boundary layer was also determined. The ratio of slot to freestream was varied to determine its effect on heating. The numerical heating rates were compared to other correlations obtained from experimental studies as well as theoretical laminar and turbulent results.

Sharpe, L., Jr.↗