Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data eye”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

How Eye Drift Adapts to the History of Eye Positions

Oculomotor behavior is a powerful tool to probe brain function and disease. Previous studies have shown how fixational drift velocities depend on eccentricity (Bertolini et al., 2013; Romano et al., 2017) and how fixational drift can adapt after prolonged eccentric fixation (Otero-Millan et al., 2019). Here, eighteen subjects completed two experiments where we measured drift velocity while fixating a briefly flashed target, to remove retinal slip cues. In the first experiment, we measured their baseline relationship between fixational drift velocity and eye position. In the second experiment, we investigated the adaptation of that relationship after prolonged fixation at a very eccentric position. This adaptation usually manifests by the presence of rebound nystagmus (RN) upon returning to central gaze. Our results replicate the finding that drift increases at central fixation in the direction consistent with rebound nystagmus, that is, towards the previously held eccentric position, highlighting that drift velocity depends on the history of eye positions. When examining the entire relationship between drift velocity and eye position we find a mostly linear relationship but with increased slope relative to the baseline condition. However, the adaptation of the integrator cannot be modeled by a simple change in leakiness, as that would not result in increased drift at central gaze. Other mechanisms of adaptation such as shifts in the position or velocity set-points for gaze holding could be present but are indistinguishable with the current data.

eye movement↗

Stabilization of gaze during circular locomotion in light. I. Compensatory head and eye nystagmus in the running monkey

1. A rhesus and cynomolgus monkey were trained to run around the perimeter of a circular platform in light. We call this "circular locomotion" because forward motion had an angular component. Head and body velocity in space were recorded with angular rate sensors and eye movements with electrooculography (EOG). From these measurements we derived signals related to the angular velocity of the eyes in the head (Eh), of the head on the body (Hb), of gaze on the body (Gb), of the body in space (Bs), of gaze in space (Gs), and of the gain of gaze (Gb/Bs). 2. The monkeys had continuous compensatory nystagmus of the head and eyes while running, which stabilized Gs during the slow phases. The eyes established and maintained compensatory gaze velocities at the beginning and end of the slow phases. The head contributed to gaze velocity during the middle of the slow phases. Slow phase Gb was as high as 250 degrees/s, and targets were fixed for gaze angles as large as 90-140 degrees. 3. Properties of the visual surround affected both the gain and strategy of gaze compensation in the one monkey tested. Gains of Eh ranged from 0.3 to 1.1 during compensatory gaze nystagmus. Gains of Hb varied around 0.3 (0.2-0.7), building to a maximum as Eh dropped while running past sectors of interest. Consistent with predictions, gaze gains varied from below to above unity, when translational and angular body movements with regard to the target were in opposite or the same directions, respectively. 4. Gaze moved in saccadic shifts in the direction of running during quick phases. Most head quick phases were small, and at times the head only paused during an eye quick phase. Eye quick phases were larger, ranging up to 60 degrees. This is larger than quick phases during passive rotation or saccades made with the head fixed. 5. These data indicate that head and eye nystagmus are natural phenomena that support gaze compensation during locomotion. Despite differential utilization of the head and eyes in various conditions, Gb compensated for Bs. There are various frames of reference in which an estimate of angular velocity that drives the head and eyes could be based. We infer that body in space velocity (Bs) is likely to be represented centrally to provide this signal.

Non-NASA Center↗

Pilot dynamics for instrument approach tasks: Full panel multiloop and flight director operations

Measurements and interpretations of single and mutiloop pilot response properties during simulated instrument approach are presented. Pilot subjects flew Category 2-like ILS approaches in a fixed base DC-8 simulaton. A conventional instrument panel and controls were used, with simulated vertical gust and glide slope beam bend forcing functions. Reduced and interpreted pilot describing functions and remmant are given for pitch attitude, flight director, and multiloop (longitudinal) control tasks. The response data are correlated with simultaneously recorded eye scanning statistics, previously reported in NASA CR-1535. The resulting combined response and scanning data and their interpretations provide a basis for validating and extending the theory of manual control displays.

Weir, D. H.↗

The SNS/HFIR Web Portal System for SANS

In a busy world, continuing with the status-quo, to do things the way we are already familiar, often seems to be the most efficient way to conduct our work. We look for the value-add to decide if investing in a new method is worth the effort. How shall we evaluate if we have reached this tipping point for change? For contemporary researchers, understanding the properties of the data is a good starting point. The new generation of neutron scattering instruments being built are higher resolution and produce one or more orders of magnitude larger data than the previous generation of instruments. For instance, we have grown out of being able to perform some important tasks with our laptops – the data are too big and the computations would simply take too long. These large datasets can be problematic as facility users now begin to grapple with many of the same issues faced by more established computing communities. These issues include data access, management, and movement, data format standards, distributed computing, and collaboration among others. The Neutron Science Portal has been architected, designed, and implemented to provide users with an easy-to-use interface for managing and processing data, while also keeping an eye on meeting modern cybersecurity requirements imposed on institutions. The cost of entry for users has been lowered by utilizing a web interface providing access to backend portal resources. Users can browse or search for data which they are allowed to see, data reduction applications can be run without having to load the software, sample activation calculations can be performed for SNS and HFIR beamlines, McStas simulations can be run on TeraGrid and ORNL computers, and advanced analysis applications such as those being produced by the DANSE project can be run. Behind the scenes is a “live cataloging” system which automatically catalogs and archives experiment data via the data management system, and provides proposal team members access to their experiment data. The complexity of data movement and utilizing distributed computing resources has been taken care on behalf of users. Collaboration is facilitated by providing users a read/writeable common area, shared across all experiment team members. To date, these shared areas are the fastest growing data spaces. The portal currently has over 370 registered users, almost 7TB of experiment and user data, approximately 1,000,000 files cataloged, and had almost 10,000 unique visits last year. Future directions for enhancing portal robustness include examining how to mirror data and portal services, better facilitation of collaborations via virtual organizations, enhancing disconnected service via “thick client” applications, and better inter-facility connectivity to support cross-cutting research. The portal has established itself in the SNS/HFIR user community, and the development team strives to continue to improve the quality of features and services provided in order to better serve the community.

data↗

NuSTAR AND MULTIFREQUENCY STUDY OF THE TWO HIGH-REDSHIFT BLAZARS S5 0836+710 AND PKS 2149–306

Powerful blazars are flat-spectrum radio quasars whose emission is dominated by a Compton component peaking between a few hundred keV and a few hundred MeV. We observed two bright blazars, PKS 2149–306 at redshift z = 2.345 and S5 0836+710 at z = 2.172, in the hard X-ray band with the Nuclear Spectroscopic Telescope Array satellite. Simultaneous soft-X-rays and UV–optical observations were performed with the Swift satellite, while near-infrared (near-IR) data were obtained with the Rapid Eye Mount telescope. To study their variability, we repeated these observations for both sources on a timescale of a few months. While no fast variability was detected during a single observation, both sources were variable in the X-ray band, up to 50%, between the two observations, with larger variability at higher energies. No variability was detected in the optical/NIR band. These data, together with Fermi-Large Area Telescope, Wide-field Infrared Survey Explorer, and other literature data, are then used to study the overall spectral energy distributions (SEDs) of these blazars. Although the jet nonthermal emission dominates the SED, it leaves the UV band unhidden, allowing us to detect the thermal emission of the disk and to estimate the black hole mass. The nonthermal emission is well reproduced by a one-zone leptonic model by the synchrotron, self-Compton, and external Compton processes. Our data are better reproduced if we assume that the location of the dissipation region of the jet, R{sub diss}, is in between the torus and the broad-line region. The observed variability is explained by changing a minimum number of model parameters by a very small amount.

79 ASTRONOMY AND ASTROPHYSICS↗

Wireless link and microelectronics design for retinal prostheses

This project focuses on delivering power and data to the artificial retinal implant inside the eye and the implant microstimulator electronics which delivers the current pulses to stimulate the retinal layer to elicit visual perception. Since the use of invasive means such as tethering wires to transmit power and data results in discomfort to the patients which could eventually cause infection due to the abrasion caused by the wire and contact of the internals of the eye to the external environment, a completely wireless approach is used to transfer both power and data. Power is required inside the eye for the microelectronic implant which uses a dual voltage supply scheme (positive and negative) to deliver biphasic (anodic and cathodic) current pulses. Data in the form of digital bits from the data transmitter external to the eye, carries information about the amplitude, phase width, interphase delay, stimulation sequence for each implant electrode. The data receiver unit decodes the digital stream and the microstimulator unit generates the appropriate current stimuli. Since the external unit consisting of the power transmitter can experience coupling a variation with the power receiver due to the patient’s movements, a closed loop approach is used which varies the transmitted power dynamically to automatically compensate for such movements. This report presents the salient features of this research activities and results.

42 ENGINEERING↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

User Directed Tools for Exploiting Expert Knowledge in an Immersive Segmentation and Visualization Environment

Volumetric data sets have become common in medicine and many sciences through technologies such as computed x-ray tomography (CT), magnetic resonance (MR), positron emission tomography (PET), confocal microscopy and 3D ultrasound. When presented with 2D images humans immediately and unconsciously begin a visual analysis of the scene. The viewer surveys the scene identifying significant landmarks and building an internal mental model of presented information. The identification of features is strongly influenced by the viewers expectations based upon their expert knowledge of what the image should contain. While not a conscious activity, the viewer makes a series of choices about how to interpret the scene. These choices occur in parallel with viewing the scene and effectively change the way the viewer sees the image. It is this interaction of viewing and choice which is the basis of many familiar visual illusions. This is especially important in the interpretation of medical images where it is the expert knowledge of the radiologist which interprets the image. For 3D data sets this interaction of view and choice is frustrated because choices must precede the visualization of the data set. It is not possible to visualize the data set with out making some initial choices which determine how the volume of data is presented to the eye. These choices include, view point orientation, region identification, color and opacity assignments. Further compounding the problem is the fact that these visualization choices are defined in terms of computer graphics as opposed to language of the experts knowledge. The long term goal of this project is to develop an environment where the user can interact with volumetric data sets using tools which promote the utilization of expert knowledge by incorporating visualization and choice into a tight computational loop. The tools will support activities involving the segmentation of structures, construction of surface meshes and local filtering of the data set. To conform to this environment tools should have several key attributes. First, they should be only rely on computations over a local neighborhood of the probe position. Second, they should operate iteratively over time converging towards a limit behavior. Third, they should adapt to user input modifying they operational parameters with time.

Senger, Steven O.↗

Three-dimensional ocular kinematics during eccentric rotations: evidence for functional rather than mechanical constraints

Previous studies have reported that the translational vestibuloocular reflex (TVOR) follows a three-dimensional (3D) kinematic behavior that is more similar to visually guided eye movements, like pursuit, rather than the rotational VOR (RVOR). Accordingly, TVOR rotation axes tilted with eye position toward an eye-fixed reference frame rather than staying relatively fixed in the head like in the RVOR. This difference arises because, contrary to the RVOR where peripheral image stability is functionally important, the TVOR like pursuit and saccades cares to stabilize images on the fovea. During most natural head and body movements, both VORs are simultaneously activated. In the present study, we have investigated in rhesus monkeys the 3D kinematics of the combined VOR during yaw rotation about eccentric axes. The experiments were motivated by and quantitatively compared with the predictions of two distinct hypotheses. According to the first (fixed-rule) hypothesis, an eye-position-dependent torsion is computed downstream of a site for RVOR/TVOR convergence, and the combined VOR axis would tilt through an angle that is proportional to gaze angle and independent of the relative RVOR/TVOR contributions to the total eye movement. This hypothesis would be consistent with the recently postulated mechanical constraints imposed by extraocular muscle pulleys. According to the second (image-stabilization) hypothesis, an eye-position-dependent torsion is computed separately for the RVOR and the TVOR components, implying a processing that takes place upstream of a site for RVOR/TVOR convergence. The latter hypothesis is based on the functional requirement that the 3D kinematics of the combined VOR should be governed by the need to keep images stable on the fovea with slip on the peripheral retina being dependent on the different functional goals of the two VORs. In contrast to the fixed-rule hypothesis, the data demonstrated a variable eye-position-dependent torsion for the combined VOR that was different for synergistic versus antagonistic RVOR/TVOR interactions. Furthermore, not only were the eye-velocity tilt slopes of the combined VOR as much as 10 times larger than what would be expected based on extraocular muscle pulley location, but also eye velocity during antagonistic RVOR/TVOR combinations often tilted opposite to gaze. These results are qualitatively and quantitatively consistent with the image-stabilization hypothesis, suggesting that the eye-position-dependent torsion is computed separately for the RVOR and the TVOR and that the 3D kinematics of the combined VOR are dependent on functional rather than mechanical constraints.

Non-NASA Center↗

Not Your Daddy's Data Link: Musings on Datalink Communications

Viewgraphs about musings on Datalink Communications are presented. Some of the topics include: 1) Keen Eye for a Straight Proposal (Next Gen Data Link); 2) So many datalinks so little funding!!!; 3) Brave New World; 4) Time marches on!; 5) Through the Looking Glass; 6) Dollars & Sense Cooking; 7) Economics 101; 8) The Missing Link(s); 9) Straight Shooting; and 10) All is not lost.

Branstetter, James↗

Distributed Storage Systems for Data Intensive Computing

In this chapter, the authors present an overview of the utility of distributed storage systems in supporting modern applications that are increasingly becoming data intensive. Their coverage of distributed storage systems is based on the requirements imposed by data intensive computing and not a mere summary of storage systems. To this end, they delve into several aspects of supporting data-intensive analysis, such as data staging, offloading, checkpointing, and end-user access to terabytes of data, and illustrate the use of novel techniques and methodologies for realizing distributed storage systems therein. The data deluge from scientific experiments, observations, and simulations is affecting all of the aforementioned day-to-day operations in data-intensive computing. Modern distributed storage systems employ techniques that can help improve application performance, alleviate I/O bandwidth bottleneck, mask failures, and improve data availability. They present key guiding principles involved in the construction of such storage systems, associated tradeoffs, design, and architecture, all with an eye toward addressing challenges of data-intensive scientific applications. They highlight the concepts involved using several case studies of state-of-the-art storage systems that are currently available in the data-intensive computing landscape.

99 GENERAL AND MISCELLANEOUS↗

Challenges in Eye Tracking for Dynamic User-Driven Workflows

This three-year Laboratory Directed Research and Development (LDRD) project aimed at developing a developed prototype data collection system and analysis techniques to enable the measurement and analysis of user-driven dynamic workflows. Over 3 years, our team developed software, algorithms, and analysis technique to explore the feasibility of capturing and automatically associating eye tracking data with geospatial content, in a user-directed, dynamic visual search task. Although this was a small LDRD, we demonstrated the feasibility of automatically capturing, associating, and expressing gaze events in terms of geospatial image coordinates, even as the human "analyst" is given complete freedom to manipulate the stimulus image during a visual search task. This report describes the problem under examination, our approach, the techniques and software we developed, key achievements, ideas that did not work as we had hoped, and unsolved problems we hope to tackle in future projects.

42 ENGINEERING↗

COMPARISON OF RADIO-FREQUENCY INTERFERENCE MITIGATION STRATEGIES FOR DISPERSED PULSE DETECTION

Impulsive radio-frequency signals from astronomical sources are dispersed by the frequency-dependent index of refraction of the interstellar media and so appear as chirped signals when they reach Earth. Searches for dispersed impulses have been limited by false detections due to radio-frequency interference (RFI) and, in some cases, artifacts of the instrumentation. Many authors have discussed techniques to excise or mitigate RFI in searches for fast transients, but comparisons between different approaches are lacking. This work develops RFI mitigation techniques for use in searches for dispersed pulses, employing data recorded in a 'Fly's Eye' mode of the Allen Telescope Array as a test case. We gauge the performance of several RFI mitigation techniques by adding dispersed signals to data containing RFI and comparing false alarm rates at the observed signal-to-noise ratios of the added signals. We find that Huber filtering is most effective at removing broadband interferers, while frequency centering is most effective at removing narrow frequency interferers. Neither of these methods is effective over a broad range of interferers. A method that combines Huber filtering and adaptive interference cancelation provides the lowest number of false positives over the interferers considered here. The methods developed here have application to other searches for dispersed pulses in incoherent spectra, especially those involving multiple beam systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Mesoscale Assimilation of TRMM Data with 4DVAR: Preliminary Results

Surface rainfall data, derived from the TRMM Microwave Image (TMI), are assimilated into the PSU/NCAR MM5 model using a 4DVAR technique. Preliminary experiments are performed to incorporate TRMM rainfall data into a hurricane initialization. It is found that the rainfall data assimilation is sensitive to the error characteristics of the data and the physics in the adjoint model. In addition, assimilating the rainfall data alone produces a more realistic eye and rain bands in the hurricane but cannot ensure improvements of hurricane intensity forecasts. Numerical results indicate that it is necessary to incorporate TRMM rainfall data together with other types of data such as wind data into the model, in which case the inclusion of the rainfall data will further improve the intensity forecast of the hurricane. This fact might imply that some proper constraints will be needed for the rainfall assimilation. Relevant results and issues will be presented.

Pu, Zhoa-Xia↗

One-Carbon Metabolism and SANS 2022 Update

Spaceflight Associated Neuro-ocular Syndrome, or SANS, affects a subset of astronauts (1, 2), and biochemical evidence has documented differences in those astronauts (3). Specifically, they had higher circulating concentrations of metabolites of the one-carbon metabolic pathway (1C), including homocysteine, and these concentrations were higher before flight (3). After ruling out many potential confounding factors in these otherwise healthy individuals (e.g., sex, kidney function, vitamin status, coffee consumption), a study of genetics was warranted. In an initial pilot effort, we documented a genetic predisposition to develop ophthalmic changes after long-duration space flight (4). That is, from a limited study of 5 single-nucleotide polymorphisms (SNPs), we found that the G allele for the MTRR A66G SNP was associated with a greater risk of choroidal folds and cotton-wool spots after flight, and the C allele for SHMT1 C1420T was protective against optic disc edema (4). These data provide a potential pathway for understanding why some individuals develop SANS, while others do not. The initial pilot study of 5 SNPs yielded striking findings, but the 1C pathway is far more complex. An effort was undertaken to examine more than 500 1C SNPs to see if a broader examination could help illuminate this association. That work is ongoing. The astronaut findings led us to advocate for the inclusion of 1C pathway genetic and biochemistry testing on other SANS-related projects, noting that genetics might help identify responders, non-responders, or outliers. The first such effort yielded evidence of an association of specific forms of the MTRR and SHMT-1 SNPs and vitamin B12 status with end-tidal CO2 after acute carbon dioxide exposure (5). The second such effort led to the identification that individuals exposed to strict head-down tilt and CO2 for 30-d who developed optic disc edema also had risk alleles for the two SNPs described above (6). Additionally, we identified a clinical population with many characteristics either attributed or purported to be involved in the ocular changes seen in affected astronauts: women with polycystic ovary syndrome (PCOS). PCOS is a condition of androgen excess and anovulatory menstrual cycles. The shared characteristics and clinical findings between SANS and PCOS generally include higher circulating homocysteine concentrations, increased retinal nerve fiber layer thickness, increased androgen concentrations (or responses), and altered carbohydrate metabolism. To our knowledge, no study has examined whether women with PCOS have asymptomatic ophthalmic anomalies observed in astronauts with SANS. While researchers have evaluated the one-carbon metabolism pathway polymorphisms of PCOS patients, and initial studies show an association with certain one-carbon polymorphisms, none have looked at the set of SNPs identified in our studies that are associated with ophthalmic changes in astronauts. Accordingly, we designed a study to evaluate the association of one-carbon pathway SNPs and ophthalmic findings in patients with PCOS and/or IIH compared to controls. Subjects provided blood samples for vitamin and one carbon biochemistry analyses, an extensive analysis of >500 SNPs associated with one carbon metabolism and had eye examinations and ocular imaging. Data analysis are underway. The data collected to date have shown associations between one carbon pathway biochemistry and genetics and incidence of SANS. The mechanisms for SANS has yet to be identified, although many hypotheses exist. Based on our data, we have developed (8, 9) and expanded (6) a multi-hit hypothesis for how these seemingly disparate findings could be linked. While intriguing, the hypothesis represents the starting point for further research. We aim to clarify the relationship between B-vitamin status and genetics with regard to the risk of SANS. Ultimately, understanding the mechanism(s) behind this will provide a means to predict, prevent, or treat these ophthalmologic pathologies in astronauts, and terrestrial populations.

S M Smith↗

Steady-state supercritical CO 2 and brine relative permeability in Berea sandstone at different temperature and pressure conditions

In this study, we measure steady-state two-phase supercritical CO 2 -brine relative permeabilities in a 61 cm-long Berea sandstone core at three different conditions (408C and 12.41 MPa, 408C and 8.27 MPa, and 608C and 12.41 MPa) under primary drainage. We use pressure taps to obtain pressure drops of individual sections of the core, and X-ray Computed Tomography (CT) to obtain in situ saturation profiles, which together help to mitigate the capillary end effect. We include previously measured relative permeabilities at 208C and 10.34 MPa, and compare all the data using both an eye-test and a statistical test. We find no appreciable temperature and pressure dependence of CO 2 relative permeability within 20–608C and 8.27–12.41 MPa. We find slight changes in the brine relative permeability between supercritical CO 2 conditions (40–608C and 8.27–12.41 MPa) and the liquid CO 2 condition (208C and 10.34 MPa). The temperature and pressure independence of CO 2 relative permeability has been previously recognized and reassured in this work using a capillary-effect-free method. This allows one to use a single CO 2 relative permeability curve in modeling two-phase CO 2 flow within 20–608C and 8.27–12.41 MPa.

58 GEOSCIENCES↗

Silicon photonic chip for 16-channel wavelength division (de-)multiplexing in the O-band

We experimentally demonstrate a silicon photonic chip-scale 16-channel wavelength division multiplexer (WDM) operating in the O-band. The silicon photonic chip consists of a common-input bus waveguide integrated with a sequence of 16 spectral add-drop filters implemented by 4-port contra-directional Bragg couplers and resonant cladding modulated perturbations. The combination of these features reduces the spectral bandwidth of the filters and improves the crosstalk. An apodization of the cladding modulated perturbations between the bus and the add/drop waveguides is used to optimize the strength of the coupling coefficient in the propagation direction to reduce the intra-channel crosstalk on adjacent channels. The fabricated chip was validated experimentally with a measured intra-channel crosstalk of ∼−18.9 dB for a channel spacing of 2.6 nm. The multiplexer/demultiplexer chip was also experimentally tested with a 10 Gbps data waveform. The resulting eye-pattern indicates that this approach is suitable for datacenter WDM-based interconnects in the O-band with large aggregate bandwidths.

Davis, Jordan A. (ORCID:0000000343483295)↗

Oculometric indices of simulator and aircraft motion

The effects on eye scan behavior of both simulator and aircraft motion and sensitivity of an oculometric measure to motion effects was demonstrated. It was found that fixation time is sensitive to motion effects. Differences between simulator motion and no motion conditions during a series of simulated ILS approaches were studied. The mean fixation time for the no motion condition was found to be significantly longer than for the motion conditions. Eye scan parameters based on data collected in flight, and in fixed base simulation were investigated. Motion effects were evident when the subject was viewing a display supplying attitude and flight path information. The nature of the information provided by motion was examined. The mean fixation times for the no motion condition were significantly longer than for either motion condition, while the two motion conditions did not differ. It is shown that motion serves an alerting function, providing a cue or clue to the pilot that something happened. It is suggested that simulation without motion cues may represent an understatement of the true capacity of the pilot.

Comstock, J. R.↗