Search NASA⌕ Search

SEARCH · Search NASA

Results for “Depth sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Application of Low-Cost Fine Particulate Mass Monitors to Convert Satellite Aerosol Optical Depth Measurements to Surface Concentrations in North America and Africa

Low-cost particulate mass sensors provide opportunities to assess air quality at unprecedented spatial and temporal resolutions. Established traditional monitoring networks have limited spatial resolution and are simply absent in many major cities across sub-Saharan Africa (SSA). Satellites provide snapshots of regional air pollution but require ground-truthing. Low-cost monitors can supplement and extend data coverage from these sources worldwide, providing a better overall air quality picture. We investigate the utility of such a multi-source data integration approach using two case studies. First, in Pittsburgh, Pennsylvania, both traditional monitoring and dense low-cost sensor networks are compared with satellite aerosol optical depth (AOD) data from NASA's MODIS system, and a linear conversion factor is developed to convert AOD to surface fine particulate matter mass concentration (as PM2.5). With 10 or more ground monitors in Pittsburgh, there is a 2-fold reduction in surface PM2.5 estimation mean absolute error compared to using only a single ground monitor. Second, we assess the ability of combined regional-scale satellite retrievals and local-scale low-cost sensor measurements to improve surface PM2.5 estimation at several urban sites in SSA. In Rwanda, we find that combining local ground monitoring information with satellite data provides a 40 % improvement in surface PM2.5 estimation accuracy with respect to using low-cost ground monitoring data alone. A linear AOD-to-surface-PM2.5 conversion factor developed in Kigali, Rwanda, did not generalize well to other parts of SSA and varied seasonally for the same location, emphasizing the need for ongoing and localized ground-based monitoring, which can be facilitated by low-cost sensors. Overall, we find that combining ground-based low-cost sensor and satellite data, even without including additional meteorological or land use information, can improve and expand spatiotemporal air quality data coverage, especially in data-sparse regions.

AOD↗

Controlling Force and Depth in Friction Stir Welding

Feedback control of the penetration force applied to a pin tool in friction stir welding has been found to be a robust and reliable means for controlling the depth of penetration of the tool. This discovery has made it possible to simplify depth control and to weld with greater repeatability, even on workpieces with long weld joints. Prior to this discovery, depths of penetration in friction stir welding were controlled by hard-tooled roller assemblies or by depth actuators controlled by feedback from such external sensors as linear variable-differential transformers or laser-based devices. These means of control are limited: A hard-tooled roller assembly confines a pin tool to a preset depth that cannot be changed easily during the welding process. A measurement by an external sensor is only an indirect indicative of the depth of penetration, and computations to correlate such a measurement with a depth of penetration are vulnerable to error. The present force-feedback approach exploits the proportionality between the depth and the force of penetration Unlike a depth measurement taken by an external sensor, a force measurement can be direct because it can be taken by a sensor coupled directly to the pin tool. The reading can be processed through a modern electronic servo control system to control an actuator to keep the applied penetration force at the desired level. In comparison with the older depth-control methods described above, this method offers greater sensitivity to plasticizing of the workpiece metal and is less sensitive to process noise, resulting in a more consistent process. In an experiment, a tapered panel was friction stir welded while controlling the force of penetration according to this method. The figure is a plot of measurements taken during the experiment, showing that force was controlled with a variation of 200 lb (890 N), resulting in control of the depth of penetration with a variation of 0.004 in. (0.1 mm).

Adams, Glynn↗

Quantifying the Observational Requirements of a Space-borne LiDAR Snow Mission

This study quantifies the level of observational accuracy required from a spaceborne light detection and ranging (LiDAR) snow depth retrieval mission for enabling beneficial impacts for snow estimation. The study is conducted over a region in Western Colorado using a suite of observing system simulation experiments(OSSEs).The Joint UK Land Environment Simulator, version 5.0 (JULES v5.0) is employed to simulate a suite of idealized LiDAR observations, considering a range of LiDAR snow depth retrieval errors, different hypothetical sensor swath widths, and the impact of cloud cover on observability. These simulated observations are then assimilated into the Noah land surface modelwith multi-parameterization options, version 3.6 (Noah-MP v3.6) model. This data assimilation setup is used to systematically evaluate the potential utility of LiDAR observations for improving modeled snow water equivalent (SWE)estimates and water budget variables such as runoff. Results from the OSSE runsshow that, in general, assimilation of synthetic LiDAR observations provide beneficial impacts when theLiDAR snow depth retrieval error standard deviation (σerror) is below 60 cm.Based on comparisons between the realistic (i.e., swath-limited and cloud-attenuated) case and the idealized (i.e., infinite swath width in the absence of cloud cover) case,this study concludes that observations with a conservative error standard deviation threshold of 40 cm (i.e., upper limit of the snow depth retrieval error that adds value to the SWE estimates viaassimilation) are needed for improving modeled snow estimates. More than a 33% reduction in SWEroot mean square errors and more than a 15% increase in correlation coefficientsare achieved when σ error ≤ 40 cmusing a 170-km sensor swath width in the presence of cloud attenuation effects. Further, the integrated hydrologic response, as represented by total (surface and subsurface) runoff estimates during the snow ablation season, are also enhanced when assimilating synthetic LiDAR snow depth retrievals with errors below this level.

Yonghwan Kwon↗

2020 Wildfire Plumes Observed by Satellite and Ground Sensors at San Francisco Bay

The main purpose of this research is to study the spreading of the 2020 wildfire plumes in the San Francisco Bay Area. Last year’s fire plumes have caused severe impact on regional air quality and public health over large part of the west coast. We studied fire plumes with two datasets: aerosol optical depth (AOD) retrieved from MODIS sensor onboard two NASA satellites (Terra and Aqua), and surface PM2.5 measurements from US Environmental Protection Agency (EPA). Satellite can monitor fire plumes from a top-down view, including active fire location, emission amount, spreading of the fire plume in both horizontal and vertical directions. EPA records air quality using the ground network of in-situ sensors. In general, the two points of view are consistent with each other. But in the peak of the 2020 fire season, we found an episode where the AOD and PM2.5 are out-of-phase for two days, in addition data from NASA satellite AERONET was use to corroborate AOD information for the episode, yielding similar results. Thereafter, we explored the possible mechanism for this shift with available meteorological measurements, including both ground measurements and sounding data. By tracking the evolution of the sounding data, we concluded a heated near surface inversion layer might shield the region from aloft fire plumes for two days before they touch down and severely downgraded the air quality over the whole Bay area.

Hazem Mahmoud↗

2020 Wildfire Plumes Observed by Satellite and Ground Sensors in the San Francesco Bay Area

The main purpose of this research is to study the spreading of the 2020 wildfire plumes in the San Francisco Bay Area. Last year’s fire plumes have caused severe impact on regional air quality and public health over large part of the west coast. We studied fire plumes with two datasets: aerosol optical depth (AOD) retrieved from MODIS sensor onboard two NASA satellites (Terra and Aqua), and surface PM2.5 measurements from US EPA. Satellite can monitor fire plumes from a top-down view, including active fire location, emission amount, spreading of the fire plume in both horizontal and vertical directions. EPA records air quality using the ground network of in-situ sensors. In general the two points of view are consistent with each other. But in the peak of the 2020 fire season, we found an episode where the AOD and PM2.5 are out-of-phase for two days. We explored the possible mechanism for this shift with available meteorological measurements, including both ground measurements and sounding data. By tracking the evolution of the sounding data, we concluded a heated near surface inversion layer might shield the region from aloft fire plumes for two days before they touch down and severely downgraded the air quality over the whole Bay area.

Hazem Mahmoud↗

An optimal sensing strategy of a proximity sensor system for recognition and localization of polyhedral objects

An algorithm is presented for the recognition and localization of thre-dimensional polyhedral objects based on an optical proximity sensor system capable of measuring the depth and orientation of a local area of an object surface. Emphasis is given to the determination of an optimal sensor trajectory or an optimal probing, for efficient discrimination among all the possible interpretations. The determination of an optimal sensor trajectory for the next probing consists of the selection of optimal beam orientations based on the surface normal vector distribution of the multiple interpretation image (MII) and the selection of an optimal probing plane by projecting the MII onto the projection plane perpendicular to a selected beam orientation and deriving the optimal path on the projection plane. The selection of optimal beam orientation and probing plane is based on the measure of discrimination power of a cluster of surfaces of an MII. Simulation results are shown.

Lee, Sukhan↗

Fuel Cycle Research & Development, Technical Monthly - February 2012

Topics discussed in this monthly report are: (1) MPACT Campaign management and integration; (2) Accounting and control technologies - microcalorimetry, electrochemical sensor, fast neutron multiplicity analysis, lead slowing down spectrometer; (3) MPACT analysis tools - modeling and simulation for analysis of safeguards performance (electrochemical), material control including process monitoring (pattern recognition, sensors), sensor for measuring density and depth of molten electrolyte, MPACT system integration and technical support.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An operational multispectral scanner for bathymetric surveys - The ABS NORDA scanner

The Naval Ocean Research and Development Activity (NORDA) is developing the Airborne Bathymetric Survey (ABS) system, which will take shallow water depth soundings from a Navy P-3 aircraft. The system combines active and passive sensors to obtain optical measurements of water depth. The ABS NORDA Scanner is the systems passive multispectral scanner whose design goal is to provide 100 percent coverage of the seafloor, to depths of 20 m in average coastal waters. The ABS NORDA Scanner hardware and operational environment is discussed in detail. The optical model providing the basis for depth extraction is reviewed and the proposed data processing routine discussed.

Haimbach, Stephen P.↗

Structure Deformation Calculation Program Based on Displacement Theory for Shape Predictions

Separated programs were written in C/C++ to validate the Displacement Transfer Functions. The Structure Deformation Calculation Program was written to combine all of the programs to calculate deformed shapes of a structure using surface strain data and structural geometrical parameters. Users do not need to know the material properties, nor the complex internal structures geometry because the Displacement Theory is purely geometrical in nature. Users only need to know the structure types as defined in this report and information such as the structure length, depth factors, number of strain sensors, and the surface strains measured at the strain-sensing stations installed on the structures. Depending on the structure type, an applicable Displacement Transfer Function will be used. This program requires two input files created by users; the recorded strain data file in comma-separated values format and the structure geometry data file in text format. The program will output the out-of-plane deflections, slopes, cross-sectional twist angles, and depth factors if applicable. All output files are created in comma-separated values format. A section in this report describes step-by-step procedures on how to use the Structure Deformation Calculation Program for structure deformed shape calculations.

Displacement theory↗

Monitoring of ground water table depth and soil moisture at the Point Reyes field site

Ground water table (GWT) depth and soil moisture (SM) have been monitored at several locations at the Point Reyes field site (Californian coastal grassland) from 2021 to 2024. Monitoring is still on-going and data may be added to this archive at later time. The SM data have been acquired using Teros 12 Meter soil moisture sensors placed at 10, 30, 60 and 90 cm depth at 5 locations along a small hillslope. These sensors also collect soil temperature and bulk conductance. In addition, some collocated sensors provide pore pressure and Photochemical Reflectance Index (PRI). The GWT depth has been inferred from various type of Onset pressure transducers. The pressure measurements have been corrected for atmospheric pressure variations and sensor position relative to the ground surface to infer GWT depth, as well as with RTK GPS data to infer GWT elevation. The GWT data have been acquired at 5 distinct locations from 2020 to 2024 with the sensors placed at about 4 m depth. In addition, GWT data has been acquired for the 2023-2024 period with sensors located in 1 m deep shallow wells installed near each deeper well. This data is intended to evaluate possibly different dynamic in shallow (perched) and deep aquifer. The datasets are all provided in csv format. Please note that the interpretation of the GWT data needs to be done with consideration of environmental and well characteristics at the site and uncertainty in various variables. For more information on GWT and SM data, please contact the author.

54 ENVIRONMENTAL SCIENCES↗

Depth-dependent Vertical-to-Horizontal (V/H) Ratios of Free-Field Ground Motion Response Spectra for Deeply Embedded Nuclear Structures

This report documents the results of a study to determine the depth-dependent V/H ratios of ground motion response spectra in the free field. The V/H ratios reported herein were developed from a worldwide database of surface and downhole acceleration recordings obtained from 45 vertical array stations. This database was specifically compiled for this project, and includes information from a diversity of active tectonic regions (California, Alaska, Taiwan, Japan), site conditions (rock to soft soil), ground motion intensity levels (PGAs between 0.01 g and 0.50 g), magnitudes (between ML 2.78 and JMA 8.1), epicentral distances (between 3.2 km and 812 km), and source depths (between 1.2 km and 112 km), as well as sensors at surface and at a wide range of depths relevant to the project. To study the significance of the depth effect, V/H ratios from all the records were sorted into a number of depth bins relevant to the project, and statistics (average, standard deviation, coefficient of variation, 16th, 50th, and 84th percentiles) of the V/H ratios within each bin were computed. Similar analyses were repeated, controlling for different site conditions, ground motion intensity levels, array locations, and source depths, to study their relative effect on the V/H ratios. Our findings confirm the importance of the depth effect on the V/H ratios. The research findings in this report can be used to provide guidance on the significance of the depth effect, and the extent to which this effect should be considered in the seismic design of deeply embedded SMR structures and NPP structures in general.

42 ENGINEERING↗

Fiber Optic Thermal Health Monitoring of Aerospace Structures and Materials

A new technique is presented for thermographic detection of flaws in materials and structures by performing temperature measurements with fiber Bragg gratings. Individual optical fibers with multiple Bragg gratings employed as surface temperature sensors were bonded to the surfaces of structures with subsurface defects or thickness variations. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The investigated structures included a 10-ply composite specimen with subsurface delaminations of various sizes and depths. The data obtained from grating sensors were further analyzed with thermal modeling to reveal particular characteristics of the interested areas. These results were found to be consistent with those from conventional thermography techniques. Limitations of the technique were investigated using both experimental and numerical simulation techniques. Methods for performing in-situ structural health monitoring are discussed.

Wu, Meng-Chou↗

Comparison of Surface and Column Variations of CO2 Over Urban Areas for Future Active Remote CO2 Sensors

High resolution in-situ CO2 measurements were recorded onboard the NASA P-3B during the DISCOVER-AQ (Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality) Field Campaign, to investigate the ability of space-based observations to accurately assess near surface conditions related to air quality. This campaign includes, Washington DC/Baltimore, MD (July 2011), San Joaquin Valley, CA (January - February 2013), Houston, TX (September 2013), and Denver, CO (July-August 2014). Each of these campaigns consisted of missed approaches and approximately two hundred vertical soundings of CO2 within the lower troposphere (surface to about 5 km). In this study, surface (0 - 1 km) and column-averaged (0 - 3.5 km) CO2 mixing ratio values from the vertical soundings in the four geographically different urban areas are used to investigate the temporal and spatial variability of CO2 within the different urban atmospheric emission environments. Tracers such as CO, CH2O, NOx, and NMHCs are used to identify the source of CO2 variations in the urban sites. Additionally, we apply nominal CO2 column weighting functions for potential future active remote CO2 sensors operating in the 1.57-microns and 2.05-microns measurement regions to convert the in situ CO2 vertical mixing ratio profiles to variations in CO2 column optical depths, which is what the active remote sensors actually measure. Using statistics calculated from the optical depths at each urban site measured during the DISCOVER-AQ field campaign and for each nominal weighting function, we investigate the natural variability of CO2 columns in the lower troposphere; relate the CO2 column variability to the urban surface emissions; and show the measurement requirements for the future ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons) in the continental U.S. urban areas.

Choi, Yonghoon↗

Microwave Treatment for Cardiac Arrhythmias

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Transcatheter Antenna For Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

In Vivo Simulator for Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoresistive cantilever force-clamp system

We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗