Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance of a Borehole XRF Spectrometer for Planetary Exploration

We have designed and constructed a borehole XRF Spectrometer (XRFS) as part of the Mars Subsurface Access program. It will be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary performance metrics for the instrument are the lower limits of detection over a wide range of the periodic table. Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight parts-per-million for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

Kelliher, Warren C.↗

Performance of a Borehole X-ray Fluorescence Spectrometer for Planetary Exploration

We have designed and constructed a borehole X-ray Fluorescence Spectrometer (XRFS) as part of the Mars Subsurface Access program [1]. It can be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary requirements and performance metrics for the instrument are to obtain parts-per-million (ppm) lower limits of detection over a wide range of elements in the periodic table (Magnesium to Lead). Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight ppm for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

Kelliher, Warren C.↗

The NASA Meter Class Autonomous Telescope: Ascension Island

The Meter Class Autonomous Telescope (MCAT) is the newest optical sensor dedicated to NASA s mission to characterize the space debris environment. It is the successor to a series of optical telescopes developed and operated by the JSC Orbital Debris Program Office (ODPO) to monitor and assess the debris environment in (1) Low Earth Orbit (LEO), (2) Medium Earth Orbit (MEO), and (3) Geosynchronous Orbit (GEO), with emphasis on LEO and GEO altitudes. A joint NASA-Air Force Research Labs project, MCAT is a 1.3m optical telescope dedicated to debris research. Its optical path and sensor yield a large survey fence at the cutting edge of current detector performance. It has four primary operational observing modes, two of which were not computationally feasible a decade ago. Operations are supported by a sophisticated software suite that monitors clouds and weather conditions, and controls everything from data collection to dome rotation to processing tens of GB of imagery data nightly. With fainter detection limits, precision detection, acquisition and tracking of targets, multi-color photometry, precision astrometry, automated reacquisition capability, and the ability to process all data at the acquisition rate, MCAT is capable of producing and processing a volume and quality of data far in excess of any current (or prior) ODPO operations. This means higher fidelity population inputs and eliminating the multi-year backlog from acquisition-to-product typical of optical campaigns. All of this is possible given a suitable observing location. Originally planned for the island of Legan, part of the Kwajalein Atoll Islands, recent developments have led to a change in venue. Specifically, the Ground-based Electro-Optical Deep Space Surveillance, or GEODSS, System of telescopes is the United States major tracking system for deep space. This network consists of telescopes in Maui, Hawaii; Diego Garcia (Indian Ocean), and Socorro, New Mexico. A fourth optical telescope, though smaller in size, has been operating in conjunction with this effort until recently in M.ron, Spain. With the M.ron site closing, a significant gap in longitude exists between the New Mexico and Diego Garcia sites. This longitudinal gap is well covered by placing a telescope on Ascension Island (7degrees 58'20" S, 14degrees 24'4"W), in the Atlantic Ocean. Ascension Island offers the benefits of both location and weather. The near equatorial location affords the opportunity to access under-sampled low-inclination orbits and new GEO longitudes, while simultaneously filling in the GEODSS longitudinal gap. Ascension Island is a volcanic, desert island, receiving only 7" of rain per year on average. With consistent trade winds blowing from the SSE direction off Africa, the combination of an island location with consistent winds will create the smooth laminar flow sought after by all astronomical sites, which creates stable atmospheric ('seeing') conditions. Finally, this low population island has minimal lighting, resulting in very dark skies, ideal for an observatory.

Lederer, S. M.↗

The NASA Meter Class Autonomous Telescope: Ascension Island

The Meter Class Autonomous Telescope (MCAT) is the newest optical sensor dedicated to NASA's mission to characterize the space debris environment. It is the successor to a series of optical telescopes developed and operated by the JSC Orbital Debris Program Office (ODPO) to monitor and assess the debris environment in (1) Low Earth Orbit (LEO), (2) Medium Earth Orbit (MEO), and (3) Geosynchronous Orbit (GEO), with emphasis on LEO and GEO altitudes. A joint NASA - Air Force Research Labs project, MCAT is a 1.3m optical telescope dedicated to debris research. Its optical path and sensor yield a large survey fence at the cutting edge of current detector performance. It has four primary operational observing modes, two of which were not computationally feasible a decade ago. Operations are supported by a sophisticated software suite that monitors clouds and weather conditions, and controls everything from data collection to dome rotation to processing tens of gigabytes of image data nightly. With fainter detection limits, precision detection, acquisition and tracking of targets, multi-color photometry, precision astrometry, automated re-acquisition capability, and the ability to process all data at the acquisition rate, MCAT is capable of producing and processing a volume and quality of data far in excess of any current (or prior) ODPO operations. This means higher fidelity population inputs and eliminating the multi-year backlog from acquisition-to-product typical of optical campaigns. All of this is possible given a suitable observing location. Ascension Island offers numerous advantages. As a British overseas territory with a US Air Force base presence, the necessary infrastructure and support already exists. It is located mid-way between Brazil and Africa at 7.93S latitude and 14.37 W longitude. With the Ground-based Electro-Optical Deep Space Surveillance (GEODSS) asset in Moron, Spain shutting down, this presents access to the sky from a unique latitude/longitude for an optical telescope. Constant trade winds from the SSE, originating from Africa, give promise to a steady laminar airflow over an island, a trait sought after to create stable atmospheric and good astronomical 'seeing' conditions with very low annual rainfall values. This combination of attributes created the necessary compelling argument to redirect MCAT to its final destination: Ascension Island.

Lederer, S. M.↗

Application of Artificial Neural Networks to Reliable Nuclear Data for Nonproliferation Modeling and Simulation

Detection and identification of special nuclear materials (SNMs) are an essential part of the US nonproliferation effort. Modern cutting-edge SNM detection methodologies rely more and more on modeling and simulation techniques. Experiments with radiological samples in realistic configurations, is the ultimate tool that establishes the minimum detection limits of SNMs in a host of different geometries. Modern modeling and simulation approaches have the potential to significantly reduce the number of experiments with radioactive sources needed to determine these detection limits and reduce the financial barrier to SNM detection. Unreliable nuclear data is one of the principal causes of uncertainty in modeling and simulating nuclear systems. In particular, nuclear cross sections introduce a significant uncertainty in the nuclear data. The goal of this research is to develop a methodology that will autonomously extract the correct nuclear resonance characteristics of experimental data in a reliable way, a task previously left to expert judgement. Accurate nuclear data will in turn allow contemporary modeling and simulation to become far more reliable, de-escalating the extent of experimental testing. Modeling and simulation techniques reduce the use and distribution of radiological sources, while at the same time increase the reliability of the currently used methods for the detection and identification of SNMs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An Investigation of Hydrogen Depth Profiling Using ToF-SIMS

Hydrogen depth distributions in silicon, zinc oxide and glass are of great interest in material research and industry. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has been used for hydrogen depth profiling for many years. However, some critical information, such as optimal instrumental settings and detection limits, is not easily available from previous publications. In this work, optimal instrumental settings and detection limits of hydrogen in silicon, zinc oxide and common glass were investigated. The recommended experimental settings for hydrogen depth profiling using ToF-SIMS are: (1) keeping pressure in the analysis chamber as low as possible, (2) using a cesium beam for sputtering and monitoring the H{sup -} signal, (3) employing monatomic ion analysis beams with the highest currents, and (4) using interlace mode. In addition, monatomic secondary ions from a matrix are recommended as references to normalize the H{sup -} signal. Detection limits of hydrogen are limited by pressure of residual gases in the analysis chamber. The base pressure of the analysis chamber (with samples) is about 7 x 10{sup -10} mbar in this study, and the corresponding detection limits of hydrogen in silicon, zinc oxide, and common glass are 1.3 x 10{sup 18} atoms/cm{sup 3}, 1.8 x 10{sup 18} atoms/cm{sup 3}, and 5.6 x 10{sup 18} atoms/cm{sup 3}, respectively.

08 HYDROGEN↗

Limiter-discriminator detection performance of Manchester and NRZ coded FSK

The theory of limiter-discriminator detection of a frequency shift keyed (FSK) carrier is reviewed and this theory is used to predict the bit error probability performance of Manchester coded and nonreturn-to-zero (NRZ) coded data. A major result of the study is that the predetection time bandwidth product BT and the deviation ratio h needed to give optimum performance for Manchester coding are seen to be larger than optimum NRZ FSK. Specifically, BT of about 2 and h of about 1 will result in Manchester performance about 2 dB worse than optimum NRZ.

Cartier, D. E.↗

RESULTS FOR THE FOURTH QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 94}Nb, {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3. (3) There is an estimated concentration of trimethylbenzene (2.25 mg/L). This is not a WAC analyte, but it is the first time this organic compound has been detected in a quarterly WAC sample from Tank 50. (4) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC. (5) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: Initial test with elemental Hg

A portable optical emission spectroscopy-cavity ringdown spectroscopy (OES-CRDS) dual-mode plasma spectrometer is described. A compact, low-power, atmospheric argon microwave plasma torch (MPT) is utilized as the emission source when the spectrometer is operating in the OES mode. The same MPT serves as the atomization source for ringdown measurements in the CRDS mode. Initial demonstration of the instrument is carried out by observing OES of multiple elements including mercury (Hg) in the OES mode and by measuring absolute concentrations of Hg in the metastable state 6s6p {sup 3}P{sub 0} in the CRDS mode, in which a palm-size diode laser operating at a single wavelength 405 nm is incorporated in the spectrometer as the light source. In the OES mode, the detection limit for Hg is determined to be 44 parts per 10{sup 9} (ppb). A strong radiation trapping effect on emission measurements of Hg at 254 nm is observed when the Hg solution concentration is higher than 50 parts per 10{sup 6} (ppm). The radiation trapping effect suggests that two different transition lines of Hg at 253.65 nm and 365.01 nm be selected for emission measurements in lower (<50 ppm) and higher concentration ranges (>50 ppm), respectively. In the CRDS mode, the detection limit of Hg in the metastable state 6s6p {sup 3}P{sub 0} is achieved to be 2.24 parts per 10{sup 12} (ppt) when the plasma is operating at 150 W with sample gas flow rate of 480 mL min{sup -1}; the detection limit corresponds to 50 ppm in Hg sample solution. Advantage of this novel spectrometer has two-fold, it has a large measurement dynamic range, from a few ppt to hundreds ppm and the CRDS mode can serve as calibration for the OES mode as well as high sensitivity measurements. Measurements of seven other elements, As, Cd, Mn, Ni, P, Pb, and Sr, using the OES mode are also carried out with detection limits of 1100, 33, 30, 144, 576, 94, and 2 ppb, respectively. Matrix effect in the presence of other elements on Hg measurements has been found to increase the detection limit to 131 ppb. These elements in lower concentrations can also be measured in the CRDS mode when a compact laser source is available to be integrated into the spectrometer in the future. This exploratory study demonstrates a new instrument platform using an OES-CRDS dual-mode technique for potential field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Critical Surface Parameters Driving Lectin-Mediated Capture of Bacteria from Solution

Lectin-functional interfaces are useful for isolation of bacteria from solution because they are low-cost and allow nondestructive, reversible capture. This study provides a systematic investigation of physical and chemical surface parameters that influence bacteria capture over lectin-functionalized polymer interfaces and then applies these findings to construct surfaces with significantly enhanced bacteria capture. The designer block copolymer poly(glycidyl methacrylate)-block-poly(vinyldimethyl azlactone) was used as a lectin attachment layer, and lectin coupling into the polymer film through azlactone–lectin coupling reactions was first characterized. Here, experimental parameters including polymer areal chain density, lectin molecular weight, and lectin coupling buffer were systematically varied to identify parameters driving highest azlactone conversions and corresponding lectin surface densities. To introduce physical nanostructures into the attachment layer, nanopillar arrays (NPAs) of varied heights (300 and 2100 nm) were then used to provide an underlying surface template for the functional polymer layer. Capture of Escherichia coli on lectin–polymer surfaces coated over both flat and NPA surfaces was then investigated. For flat polymer interfaces, bacteria were detected on the surface after incubation at a solution concentration of 10 3 cfu/mL, and a corresponding detection limit of 1.7 × 10 3 cfu/mL was quantified. This detection limit was 1 order of magnitude lower than control lectin surfaces functionalized with standard, carbodiimide coupling chemistry. NPA surfaces containing 300 nm tall pillars further improved the detection limit to 2.1 × 10 2 cfu/mL, but also reduced the viability of captured cells. Finally, to investigate the impact of cell surface parameters on capture, we used Agrobacterium tumefaciens cells genetically modified to allow manipulation of exopolysaccharide adhesin production levels. Statistical analysis of surface capture levels revealed that lectin surface density was the primary factor driving capture, as opposed to exopolysaccharide adhesin expression. These findings emphasize the critical importance of the synthetic interface and the development of surfaces that combine high lectin densities with tailored physical features to drive high levels of capture. These insights will aid in design of biofunctional interfaces with physicochemical surface properties favorable for capture and isolation of bacteria cells from solutions.

59 BASIC BIOLOGICAL SCIENCES↗

Partial Least Squares Calibration Modeling Towards the Multivariate Limit of Detection for Enriched Isotopic Mixtures via Laser Ablation Molecular Isotopic Spectroscopy

The psuedo univariate limit of detection was calculated to compare to the multivariate interval. ompared with results from the psuedounivariate LOD, the multivariate LOD includes other factors (i.e. signal uncertainties) and the reveals the significance in creating models that not only use the analyte’s emission line but also its entire molecular spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of the Fluorine, Chlorine and Hydrogen Content of Apatites With the ChemCam LIBS Instrument

Determining the composition of apatites is important to understand the behavior of volatiles during planetary differentiation. Apatite is an ubiquitous magmatic mineral in the SNC meteorites. It is a significant reservoir of halogens in these meteorites and has been used to estimate the halogen budget of Mars. Apatites have been identified in sandstones and pebbles at Gale crater by ChemCam, a Laser-Induced Breakdown Spectroscometer (LIBS) instrument onboard the Curiosity rover. Their presence was inferred from correlations between calcium, fluorine (using the CaF molecular band centered near 603 nm, whose detection limit is much lower that atomic or ionic lines and, in some cases, phosphorus (whose detection limit is much larger). An initial quantification of fluorine, based on fluorite (CaF2)/basalt mixtures and obtained at the LANL laboratory, indicated that the excess of F/Ca (compared to the stoichiometry of pure fluorapatites) found on Mars in some cases could be explained by the presence of fluorite. Chlorine was not detected in these targets, at least above a detection limit of 0.6 wt% estimated from. Fluorapatite was later also detected by X-ray diffraction (with CheMin) at a level of approx.1wt% in the Windjana drill sample (Kimberley area), and several points analyzed by ChemCam in this area also revealed a correlation between Ca and F. The in situ detection of F-rich, Cl-poor apatites contrasts with the Cl-rich, F-poor compositions of apatites found in basaltic shergottites and in gabbroic clasts from the martian meteorite NWA 7034, which were also found to be more Cl-rich than apatites from basalts on Earth, the Moon, or Vesta. The in situ observations could call into question one of the few possible explanations brought forward to explain the SNC results, namely that Mars may be highly depleted in fluorine. The purpose of the present study is to refine the calibration of the F, Cl, OH and P signals measured by the ChemCam LIBS instrument, initiated for F, for Cl in soils, for P, and estimate their limit of detection. For this purpose, different types of apatites and mixtures of basalt powder and apatites were analyzed using ChemCam Engineering Qualification Model (EQM) at IRAP, Toulouse. The present abstract presents the initial results from the laboratory analyses. Differences between the response function of the EQM and the Flight Model of ChemCam are still to be refined to apply these new results to the Martian dataset.

Meslin, P.-Y.↗

Measurement of reactive and condensable gas permeation using a mass spectrometer

Permeation of water vapor, oxygen, nitrogen, and carbon dioxide through polymer films is measured by the programed valving mass spectrometry (PVMS) method. The results are calibrated with a standard permeation rate for each gas to determine the detection sensitivity. The calibrated lower detection limits are 1.90x10{sup -7} g/m{sup 2} day for water vapor, 2.81x10{sup -2} cm{sup 3}/m{sup 2} day for oxygen, 2.15x10{sup -2} cm{sup 3}/m{sup 2} day for nitrogen, and 3.29x10{sup -2} cm{sup 3}/m{sup 2} day for carbon dioxide. The lower detection limits presented here for water vapor, nitrogen, and carbon dioxide are more than two orders of magnitude lower than the corresponding values offered by the NIST-traceable standard techniques. In addition, the PVMS water vapor lower detection limit meets the sensitivity requirement for detecting 'ultrabarrier' water vapor permeation rates, while the oxygen lower detection limit is higher than that offered by the standard technique. However, the results suggest a modified measurement protocol and/or system modifications to overcome this limitation. Effusivity through a flow orifice was also examined using the PVMS method for the above gases. The effusion results from the flow orifice, combined with the permeation results from polymer samples, provide insight into the factors that may influence gas detection sensitivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial Beta-Gamma Nuclear Detector Background Study

Detection of underground nuclear explosions and, more recently, nuclear reactor events is of great national interest. These measurements are most often made by determining the concentration of radioactive noble gases in the atmosphere. Currently there are several ground-based systems capable of making radioxenon gas measurements. The measurement is often close to the detection limit, so understanding the parameters and features that limit the measurement is very important. A preliminary study of the detection limit has been performed using a -Quad detector designed at Pacific Northwest National Laboratory (PNNL). The initial study has concentrated on the measuring the ambient radioactive background. By making several background measurements while varying the detector, shielding it is possible to identify whether the ambient background is internal or external to the detector. Furthermore, internal background contributions can be potentially reduced by selecting alternative low-background materials, while external background can be reduced by increasing the active or passive shielding present. By reducing the background contributions, it is possible to improve the detection limit and therefore the likelihood of positively identifying a nuclear test.

Cooper, Matthew W.↗

Stream Chemistry, Synoptic Surveys, East Fork Poplar Creek Watershed, TN, USA; April 2023 to February 2025

Impacts of developed land cover on stream chemistry can be difficult to discern from natural variability, particularly in carbonate watersheds where weathering of urban infrastructure and lithology generate similar signatures. We evaluated how spatial patterns of stream chemistry varied across perennial and non-perennial tributaries spanning an urban-to-forested gradient in a mid-order, carbonate-dominated watershed. This data package contains a processed and compiled summary of stream chemistry and properties obtained from 12 synoptic surveys of 54 stream sites across the East Fork Poplar Creek watershed located near Oak Ridge, TN, United States. The sites include non-perennial tributaries, perennial tributaries, and the main stem and span forested to urban (highly developed) land cover gradients. The data package includes the processed and flagged chemical data (WaDE_SynopticSummary_FinalChemistry), metadata describing data flagging and analysis (WaDE_SynopticSummary_Metadata), information about each site and its contributing subcatchment (WaDE_SynopticSummary_SiteInformation), and a comparison of instrument and field detection limits used to determine method detection limits for the study (WaDE_SynopticSummary_DetectionLimitComparison). Stream chemistry includes stream parameters measured in situ using multiparameter probes (dissolved oxygen, pH, specific conductance, temperature) and solutes including nutrients (nitrate, ammonium, soluble reactive phosphorus), dissolved organic carbon, dissolved inorganic carbon, major cations (calcium, magnesium, potassium, sodium), major anions (chloride, sulfate), and a broad suite of minor and trace elements.

EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > SURFACE ↗

High sensitivity boron quantification in bulk silicon using the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be nuclear reaction

There is a great need to quantify sub-ppm levels of boron in bulk silicon. There are several methods to analyze B in Si: Nuclear Reaction Analysis using the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be reaction exhibits a quantification limit of some hundreds ppm of B in Si. Heavy Ion Elastic Recoil Detection Analysis offers a detection limit of 5 to 10 at. ppm. Secondary Ion Mass Spectrometry is the method of choice of the semiconductor industry for the analysis of B in Si. This work verifies the use of NRA to quantify B in Si, and the corresponding detection limits. Proton beam with 1.6 up to 2.6 MeV was used to obtain the cross-section of the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be nuclear reaction at 170 Degree-Sign scattering angle. The results show good agreementwith literature indicating that the quantification of boron in silicon can be achieved at 100 ppm level (high sensitivity) at LAMFI-IFUSP with about 16% uncertainty. Increasing the detection solid angle and the collected beam charge, can reduce the detection limit to less than 100 ppm meeting present technological needs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differential versus limiter-discriminator detection of narrow-band FM

The error probability performance of differential detection of narrow-band FM is determined and compared with the analogous results for limiter-discriminator detection of the same modulation. It is shown that over a large class of benign and hostile environments, e.g., Gaussian IF filter, AWGN, partial-band noise jamming, the differential detector offers no theoretical performance advantage over the limiter-discriminator receiver with integrate-and-dump postdetection filtering.

Simon, M. K.↗