Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Structural analysis of polymer thin films using GISAXS in the tender X-ray region: Concept and design of GISAXS experiments using the tender X-ray energy at BL-15A2 at the Photon Factory

If small angle X-ray scattering (SAXS) utilizing the soft X-ray region is available, advanced and unique experiments, which differ from traditional SAXS methods, can be realized. For example, grazing-incidence small angle X-ray scattering (GISAXS) using hard X-ray is a powerful tool for understanding the nanostructure in both vertical and lateral directions of thin films, while GISAXS utilizing the tender X-ray region (SX-GISAXS) enables depth-resolved analysis as well as a standard GISAXS analysis in thin films. Thus, at BL-15A2 at the Photon Factory, a dedicated diffractometer for SX-GISAXS (above 2.1 keV) was constructed. This diffractometer is composed of four vacuum chambers and can be converted into the vacuum state from the sample chamber in front of the detector surface. Diffractions are clearly observed until 12th peak when measuring collagen by SAXS with an X-ray energy of 2.40 keV and a camera length of 825 mm. Additionally, we conducted the model experiment using SX-GISAXS with an X-ray energy of 2.40 keV to confirm that a poly(methyl methacrylate)-poly(n-butyl acrylate) block copolymer thin film has a microphase-separated structure in the thin film, which is composed of lamellae aligned both parallel and perpendicular to the substrate surface. Similarly, in a polystyrene-poly(methyl methacrylate) block copolymer thin film, SX-GISAXS with 3.60 keV and 5.73 keV revealed that hexagonally packed cylinders are aligned parallel to the substrate surface. The incident angle dependence of the first order peak position of the q{sub z} direction obtained from experiments at various incident X-ray energies agrees very well with the theoretical one calculated from the distorted wave Born approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental setup combining in situ hard X-ray photoelectron spectroscopy and real-time surface X-ray diffraction for characterizing atomic and electronic structure evolution during complex oxide heterostructure growth

We describe the next-generation system for in situ characterization of a complex oxide thin film and heterostructure growth by pulsed laser deposition (PLD) using synchrotron hard X-rays. The system consists of a PLD chamber mounted on a diffractometer allowing both real-time surface X-ray diffraction (SXRD) and in situ hard X-ray photoelectron spectroscopy (HAXPES). HAXPES is performed in the incident X-ray energy range from 4 to 12 keV using a Scienta EW4000 electron energy analyzer mounted on the PLD chamber fixed parallel with the surface normal. In addition to the standard application mode of HAXPES for disentangling surface from bulk properties, the increased penetration depth of high energy photoelectrons is used for investigation of the electronic structure changes through thin films grown deliberately as variable thickness capping layers. Such heterostructures represent model systems for investigating a variety of critical thickness and dead layer phenomena observed at complex oxide interfaces. In this new mode of operation, in situ HAXPES is used to determine the electronic structure associated with unique structural features identified by real-time SXRD during thin film growth. The system is configured for using both laboratory excitation sources off-line and on-line operation at beamline 33-ID-D at the Advanced Photon Source. We illustrate the performance of the system by preliminary scattering and spectroscopic data on oxygen vacancy ordering induced perovskite-to-brownmillerite reversible phase transformation in La 2/3 Sr 1/3 MnO 3 films capped with oxygen deficient SrTiO 3–δ (100) layers of varying thickness.

47 OTHER INSTRUMENTATION↗

3D-printed B 4 C collimation for neutron pressure cells

A design for an incident-beam collimator for the Paris–Edinburgh pressure cell is described here. This design can be fabricated from reaction-bonded B 4 C but also through fast turnaround, inexpensive 3D-printing. 3D-printing thereby also offers the opportunity of composite collimators whereby the tip closest to the sample can exhibit even better neutronic characteristics. Here, we characterize four such collimators: one from reaction-bonded B 4 C, one 3D-printed and fully infiltrated with cyanoacrylate, a glue, one with a glue-free tip, and one with a tip made from enriched 10 B 4 C. The collimators are evaluated on the Spallation Neutrons and Pressure Diffractometer of the Spallation Neutron Source and the Wide-Angle Neutron Diffractometer at the High Flux Isotope Reactor, both at Oak Ridge National Laboratory. This work clearly shows that 3D-printed collimators perform well and also that composite collimators improve performance even further. Beyond use in the Paris–Edinburgh cell, these findings also open new avenues for collimator designs as clearly more complex shapes are possible through 3D printing. An example of such is shown here with a collimator made for single-crystal samples measured inside a diamond anvil cell. These developments are expected to be highly advantageous for future experimentation in high pressure and other extreme environments and even for the design and deployment of new neutron scattering instruments.

47 OTHER INSTRUMENTATION↗

A scanning CCD detector for powder diffraction measurements

Several different approaches have traditionally been used for detection of X-ray powder diffraction patterns, including area detectors, point detectors and position-sensitive detectors. Each has advantages. This paper discusses use of a low-cost CCD detector attached to a diffractometer arm, where line-by-line readout of the CCD is coupled to continuous motion of the arm. When this type of detector is used and where X-ray optics are employed to focus the source image onto the detector plane both high-resolution and rapid measurements can be performed, with data collection over a complete 2θ range. This is particularly advantageous for synchrotron applications but valuable also for Guinier diffractometer laboratory instruments. Peak resolutions are shown to be moderately better than what can be obtained with a position-sensitive detector and significantly better than with an area detector. Many samples have intrinsically broadened peak shapes for which little improvement in data quality could be obtained with an analyzer-crystal detector. With comparable numbers of modules, these CCD data collection speeds can be close to those with position-sensitive detectors, but without the low-angle asymmetry seen in the latter.

Toby, B. H.↗

Cryogenic Neutron Protein Crystallography: routine methods and potential benefits

The use of cryocooling in neutron diffraction has been hampered by several technical challenges such as the need for specialized equipment and techniques. Recently we have developed and deployed equipment and strategies that allow for routine neutron data collection on cryocooled crystals using off the shelf components. This system has several advantages, compared to a closed displex cooling system such as fast cooling coupled with easier crystal mounting and centering. The ability to routinely collect cryogenic neutron data for analysis will significantly broaden the range of scientific questions that can be examined by neutron protein crystallography. Cryogenic neutron data collection for macromolecules has recently become available at the new Biological Diffractometer BIODIFF at FRM II and the Macromolecular Diffractometer (MaNDi) at the Spallation Neutron Source, Oak Ridge National Laboratory. To evaluate the benefits of a cryocooled neutron structure we collected a full neutron data set on the BIODIFF instrument on a Toho-1 lactamase structure at 100K.

Weiss, Kevin L.↗

Event-based processing of neutron scattering data at the Spallation Neutron Source

Here, the Spallation Neutron Source at Oak Ridge National Laboratory, USA, ushered in a new era of neutron scattering experiments through the use of event-based data. Tagging each neutron event allows pump–probe experiments, measurements with a parameter asynchronous to the source, measurements with continuously varying parameters and novel ways of testing instrument components. This contribution will focus on a few examples. A pulsed magnet has been used to study diffraction under extreme fields. Continuous ramping of temperature is becoming standard on the POWGEN diffractometer. Battery degradation and phase transformations under heat and stress are often studied on the VULCAN diffractometer. Supercooled Al 2 O 3 was studied on NOMAD. A study of a metallic glass through its glass transition was performed on the ARCS spectrometer, and the effect of source variation on chopper stability was studied for the SEQUOIA spectrometer. Besides a summary of these examples, an overview is provided of the hardware and software advances to enable these and many other event-based measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MILK : a Python scripting interface to MAUD for automation of Rietveld analysis

Modern diffraction experiments ( e.g. in situ parametric studies) present scientists with many diffraction patterns to analyze. Interactive analyses via graphical user interfaces tend to slow down obtaining quantitative results such as lattice parameters and phase fractions. Furthermore, Rietveld refinement strategies ( i.e. the parameter turn-on-off sequences) tend to be instrument specific or even specific to a given dataset, such that selection of strategies can become a bottleneck for efficient data analysis. Managing multi-histogram datasets such as from multi-bank neutron diffractometers or caked 2D synchrotron data presents additional challenges due to the large number of histogram-specific parameters. To overcome these challenges in the Rietveld software Material Analysis Using Diffraction ( MAUD ), the MAUD Interface Language Kit ( MILK ) is developed along with an updated text batch interface for MAUD . The open-source software MILK is computer-platform independent and is packaged as a Python library that interfaces with MAUD . Using MILK , model selection ( e.g. various texture or peak-broadening models), Rietveld parameter manipulation and distributed parallel batch computing can be performed through a high-level Python interface. A high-level interface enables analysis workflows to be easily programmed, shared and applied to large datasets, and external tools to be integrated with MAUD . Through modification to the MAUD batch interface, plot and data exports have been improved. The resulting hierarchical folders from Rietveld refinements with MILK are compatible with Cinema: Debye–Scherrer , a tool for visualizing and inspecting the results of multi-parameter analyses of large quantities of diffraction data. In this manuscript, the combined Python scripting and visualization capability of MILK is demonstrated with a quantitative texture and phase analysis of data collected at the HIPPO neutron diffractometer.

97 MATHEMATICS AND COMPUTING↗

A preliminary neutron crystallographic study of thaumatin

Preliminary neutron crystallographic data from the sweet protein thaumatin have been recorded using the LADI-III diffractometer at the Institut Laue Langevin (ILL). The results illustrate the feasibility of a full neutron structural analysis aimed at further understanding the molecular basis of the perception of sweet taste. Such an analysis will exploit the use of perdeuterated thaumatin. A preliminary neutron crystallographic study of the sweet protein thaumatin is presented. Large hydrogenated crystals were prepared in deuterated crystallization buffer using the gel-acupuncture method. Data were collected to a resolution of 2 Å on the LADI-III diffractometer at the Institut Laue Langevin (ILL). The results demonstrate the feasibility of a full neutron crystallographic analysis of this structure aimed at providing relevant information on the location of H atoms, the distribution of charge on the protein surface and localized water in the structure. This information will be of interest for understanding the specificity of thaumatin–receptor interactions and will contribute to further understanding of the molecular mechanisms underlying the perception of taste.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of rapidly synthesized guest-filled porous complexes with synchrotron radiation: practical guidelines for the crystalline sponge method

This report describes complete practical guidelines and insights for the crystalline sponge method, which have been derived through the first use of synchrotron radiation on these systems, and includes a procedure for faster synthesis of the sponges. These guidelines will be applicable to crystal sponge data collected at synchrotrons or in-house facilities, and will allow researchers to obtain reliable high-quality data and construct chemically and physically sensible models for guest structural determination. A detailed set of synthetic and crystallographic guidelines for the crystalline sponge method based upon the analysis of expediently synthesized crystal sponges using third-generation synchrotron radiation are reported. The procedure for the synthesis of the zinc-based metal–organic framework used in initial crystal sponge reports has been modified to yield competent crystals in 3 days instead of 2 weeks. These crystal sponges were tested on some small molecules, with two being unexpectedly difficult cases for analysis with in-house diffractometers in regard to data quality and proper space-group determination. These issues were easily resolved by the use of synchrotron radiation using data-collection times of less than an hour. One of these guests induced a single-crystal-to-single-crystal transformation to create a larger unit cell with over 500 non-H atoms in the asymmetric unit. This led to a non-trivial refinement scenario that afforded the best Flack x absolute stereochemical determination parameter to date for these systems. The structures did not require the use of PLATON/SQUEEZE or other solvent-masking programs, and are the highest-quality crystalline sponge systems reported to date where the results are strongly supported by the data. A set of guidelines for the entire crystallographic process were developed through these studies. In particular, the refinement guidelines include strategies to refine the host framework, locate guests and determine occupancies, discussion of the proper use of geometric and anisotropic displacement parameter restraints and constraints, and whether to perform solvent squeezing/masking. The single-crystal-to-single-crystal transformation process for the crystal sponges is also discussed. The presented general guidelines will be invaluable for researchers interested in using the crystalline sponge method at in-house diffraction or synchrotron facilities, will facilitate the collection and analysis of reliable high-quality data, and will allow construction of chemically and physically sensible models for guest structural determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The interatomic vector's method, algorithms, and programs for the solution of atomic structure of nanoclusters in crystal

A calculation technique and corresponding algorithms have been developed using the formalism of Fourier transform of finite functions. A software package for obtaining distributions of cluster interatomic vectors from diffuse X-ray scattering has been written and debugged. The programs were checked on a 30-atom cluster [CdTb{sub 3}F{sub 26}]. The attempts to obtain experimental data on a single crystal with nanoclusters using an Xcalibur S diffractometer (Oxford Diffraction) with a coordinate CCD detector were no success. The standard diffractometer software contains errors that lead to incorrect results upon the reconstruction of the distribution of diffuse scattering from different runs. These errors are of little importance when Bragg peaks are processed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Unified User-Friendly Instrument Control and Data Acquisition System for the ORNL SANS Instrument Suite

In an effort to upgrade and provide a unified and improved instrument control and data acquisition system for the Oak Ridge National Laboratory (ORNL) small-angle neutron scattering (SANS) instrument suite—biological small-angle neutron scattering instrument (Bio-SANS), the extended q-range small-angle neutron scattering diffractometer (EQ-SANS), the general-purpose small-angle neutron scattering diffractometer (GP-SANS)—beamline scientists and developers teamed up and worked closely together to design and develop a new system. We began with an in-depth analysis of user needs and requirements, covering all perspectives of control and data acquisition based on previous usage data and user feedback. Our design and implementation were guided by the principles from the latest user experience and design research and based on effective practices from our previous projects. In this article, we share details of our design process as well as prominent features of the new instrument control and data acquisition system. The new system provides a sophisticated Q-Range Planner to help scientists and users plan and execute instrument configurations easily and efficiently. The system also provides different user operation interfaces, such as wizard-type tool Panel Scan, a Scripting Tool based on Python Language, and Table Scan, all of which are tailored to different user needs. The new system further captures all the metadata to enable post-experiment data reduction and possibly automatic reduction and provides users with enhanced live displays and additional feedback at the run time. We hope our results will serve as a good example for developing a user-friendly instrument control and data acquisition system at large user facilities.

47 OTHER INSTRUMENTATION↗

A Paris-Edinburgh Cell for High-Pressure and High-Temperature Structure Studies on Silicate Liquids Using Monochromatic Synchrotron Radiation

A Paris-Edinburgh press combined with a multi-channel collimator assembly has been commissioned at the GeoSoilEnviro Center for Advanced Radiation Sources (GSECARS) beamline for monochromatic X-ray scattering, with an emphasis on studying low-Z liquids, especially silicate liquids at high pressure. The Paris-Edinburgh press is mounted on a general-purpose diffractometer, with a pixel array detector mounted on the detector arm. The incident monochromatic undulator beam with energies up to 60 keV is focused both horizontally and vertically to a beam size about 30 × 30 µm. With this setup, background scattering from the surrounding pressure media is completely removed at 2θ angles above 10° for samples larger than 1.05 mm in diameter. Thirty minutes is typically sufficient to collect robust X-ray scattering signals from a 1.6 mm diameter amorphous silicate sample. Cell assemblies for the standard Paris-Edinburgh anvils have been developed and pressures and temperatures up to 7 GPa and 2300 K, respectively, have been maintained steadily over hours. We have also developed a cupped-toroidal Drickamer anvil to further increase pressure and temperature capabilities. The cupped-toroidal Drickamer anvil combines features of a modified Drickamer anvil and the traditional Paris-Edinburgh anvil. Pressures up to 12 GPa have been generated at temperatures up to 2100 K.

58 GEOSCIENCES↗

Reciprocal Space Mapping of Macromolecular Crystals in the Laboratory

The technique of reciprocal space mapping applied to the physical measurement of macromolecular crystals will be described. This technique uses a triple axis diffractometer setup whereby the monochromator is the first crystal, the sample is the second and the third crystal (of the same material as the monochromator) analyzes the diffracted beam. The geometry is such that it is possible to separate mosaic volume effects from lattice strain effects. The deconvolution of the instrument parameters will also be addressed. Results from measurements at Brookhaven National Synchrotron Radiation Source carried out on microgravity and ground-grown crystals will be presented. The required beam characteristics for reciprocal space mapping are also ideal for topographic studies and the first topographs ever recorded from microgravity protein crystal samples will be shown. We are now working on a system which will enable reciprocal space mapping, mosaicity and topography studies to be carried out in the home laboratory. This system uses a rotating anode X-ray source to provide an intense beam then a Bartels double crystal, four reflection monochromator to provide the spectral and geometric beam conditioning necessary such that the instrument characteristics do not mask the measurement. This is coupled to a high precision diffractometer and sensitive detector. Commissioning data and first results from the system will be presented.

Snell, Edward H.↗

Stability of cenospheres in lightweight cement composites in terms of alkali-silica reaction

This paper presents an experimental study on characteristics and stability of cenospheres used in lightweight cement composites. ASTM C227 and C1260 tests were used to evaluate if cenospheres are potentially deleterious due to alkali-silica reaction (ASR). Natural sand was used as control. Examination by scanning electron microscope with energy-dispersive X-ray spectroscopy and analyses by X-ray diffractometer and thermogravimetry were conducted on samples with cenospheres after 9-month C227 and C1260 tests to better understand the behavior of cenospheres exposed to high alkaline environments and higher temperatures in these tests. Results indicate that cenospheres are not potentially deleterious due to ASR. Expansion of the mortar specimens tested to ASTM C227 and C1260 seems to be affected by the pozzolanic reactivity of cenospheres. Fine cenospheres showed limited pozzolanic reactivity at 28-30 Degree-Sign C and 38 Degree-Sign C, but exhibited significant pozzolanic reactivity at 80 Degree-Sign C with aluminum tobermorite [Ca{sub 5}Si{sub 5}Al(OH)O{sub 17} Bullet-Operator 5H{sub 2}O] identified as the main reaction product.

36 MATERIALS SCIENCE↗

Synthesis of nanosized silicon particles by a rapid metathesis reaction

A solid-state rapid metathesis reaction was performed in a bed of sodium silicofluoride (Na{sub 2}SiF{sub 6}) and sodium azide (NaN{sub 3}) powders diluted with sodium fluoride (NaF), to produce silicon nanoparticles. After a local ignition of Na{sub 2}SiF{sub 6}+4NaN{sub 3}+kNaF mixture (here k is mole number of NaF), the reaction proceeded in a self-sustaining combustion mode developing high temperatures (950-1000 deg. C) on very short time scales (a few seconds). Silicon nanoparticles prepared by the combustion process was easily separated from the salt byproducts by simple washing with distilled water. The structural and morphological studies on the nanoparticles were carried out using X-ray diffractometer (XRD) and field emission scanning electron microscope (FESEM). The mean size of silicon particles calculated from the FESEM image was about 37.75 nm. FESEM analysis also shows that the final purified product contains a noticeable amount of silicon fibers, dendrites and blocks, along with nanoparticles. The mechanism of Si nanostructures formation is discussed and a simple model for interpretation of experimental results is proposed. - Graphical abstract: Silicon nanoparticles 37.75 nm in mean diameter was obtained by rapid metathesis reaction performed in Na{sub 2}SiF{sub 6}+4NaN{sub 3} powder bed diluted with NaF.

36 MATERIALS SCIENCE↗

Fabrication and Characterization of Elliptically-Curved, Laterally-Graded Multilayers for Focusing X-ray Polychromator Applications

We have developed a novel X-ray multilayer working as a focusing polychromator. A multilayer mirror enables independent designs of the focal length and the spectral dispersion, and much higher throughput than the curved crystal. Our ion beam sputtering deposition apparatus has a speed programmable shuttering system for control of the lateral thickness gradient. A SiC/C and three V/C multilayers were deposited on each 150 mm long Si wafers. Period thicknesses are tuned to the designed energy of 5-12 keV, 12-19 keV, 19-26 keV and 26-33 keV, respectively. Four multilayers were clamped to form a 600 mm long 5-33 keV range elliptic mirror on a shaped Cu base plate. The focal length is 700 mm, which is large enough for setups around the sample position. The energy calibration was performed at BL-15C of the Photon Factory based on absorption edges of metal foils, which was in good agreement with the period thickness measured by a laboratory X-ray diffractometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photoluminescent and Thermoluminescent Studies of Dy{sup 3+} and Eu{sup 3+} Doped Y{sub 2}O{sub 3} Phosphors

Eu{sup 3+} doped and Dy{sup 3+} codoped yttrium oxide (Y{sub 2}O{sub 3}) phosphors have been prepared using solid-state reaction technique (SSR). The prepared phosphors were characterized by X-ray diffractometer (XRD), energy dispersive X-ray (EDX) spectroscopy, scanning electron microscopy (SEM) and Fourier transforms infrared spectroscopy (FTIR) techniques. Photoluminescence (PL) and Thermoluminescence (TL) properties were studied in detail. PL emission spectra were recorded for prepared phosphors under excitation wavelength 254 nm, which show a high intense peak at 613 nm for Y{sub 2}O{sub 3}:Dy{sup 3+}, Eu{sup 3+} (1:1.5 mol %) phosphor. The correlated color temperature (CCT) and CIE analysis have been performed for the synthesized phosphors. TL glow curves were recorded for Eu{sup 3+}doped and Dy{sup 3+}codoped phosphors to study the heating rate effect and dose response. The kinetic parameters were calculated using peak shape method for UV and γ exposures through computerized glow curve deconvolution (CGCD) technique. The phosphors show second order kinetics and activation energies varying from 5.823 × 10{sup − 1} to 18.608 × 10{sup − 1} eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Environmentally Friendly Chitosan-g-poly(acrylic acid-co-acrylamide)/Ground Basalt Superabsorbent Composite for Agricultural Applications

This paper investigates on the preparation of a novel eco-friendly composite hydrogel, chitosan-g-poly(acrylic acid-co-acrylamide)/ground basalt and its potential application as a soil ameliorant. Synthesis was undergone using microwave irradiation. N,N′-methylene bisacrylamide MBA was used as a cross-linker, whereas potassium peroxydisulfate KPS and N,N,N′,N′-tetramethylene diamine TEMED were used as radical initiator and reaction accelerator, respectively. The incorporation of ground basaltic rocks into the hydrogel was very beneficial: (i) It lowers the cost of the final hydrogel, (ii) It enhances the mechanical strength of the hydrogel, (iii) It boosts the maximum water absorbency of the composite, 650 g/g versus 450 g/g for the hydrogel without basalt and (iv) It promotes the thermal stability of the composite in comparison with the hydrogel alone. The prepared composite hydrogel was characterized by FTIR, X-ray diffractometer and scanning electron microscope SEM. The effects of pH and ionic strength on water absorbency were also investigated. The role of the prepared composite as a soil conditioner is performed using eggplant (Solanum melongena) as a model.

77 NANOSCIENCE AND NANOTECHNOLOGY↗