Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Controlled Formation of Conduction Channels in Memristive Devices Observed by X–ray Multimodal Imaging

Neuromorphic computing provides a means for achieving faster and more energy efficient computations than conventional digital computers for artificial intelligence (AI). However, its current accuracy is generally less than the dominant software-based AI. The key to improving accuracy is to reduce the intrinsic randomness of memristive devices, emulating synapses in the brain for neuromorphic computing. Here using a planar device as a model system, the controlled formation of conduction channels is achieved with high oxygen vacancy concentrations through the design of sharp protrusions in the electrode gap, as observed by X-ray multimodal imaging of both oxygen stoichiometry and crystallinity. Classical molecular dynamics simulations confirm that the controlled formation of conduction channels arises from confinement of the electric field, yielding a reproducible spatial distribution of oxygen vacancies across switching cycles. Furthermore, this work demonstrates an effective route to control the otherwise random electroforming process by electrode design, facilitating the development of more accurate memristive devices for neuromorphic computing.

36 MATERIALS SCIENCE↗

IoT Devices and Applications for Wire-Based Hybrid Manufacturing Machine Tools

Hybrid manufacturing machine tools have the potential to be a disruptive technology as they can leverage the benefits of both additive and subtractive manufacturing by incorporating both processes on the same machine while limiting the downsides of the individual processes. Since these machines use two very disparate manufacturing processes and hybrid manufacturing is an emerging technology, it will be useful to monitor data coming from the machine and apply it to improve the manufacturing process, the operation of the machine, and to integrate the machine into the larger digital framework of Industrial Internet of Things (IoT). The present work discusses IoT devices that would be beneficial to add to a hybrid machine tool as well as applications for those devices. The proposed methods discussed in this work have not been experimentally implemented on a hybrid machine tool and so there are no performance data available yet. The hybrid machine tool used as a basis to generate these IoT applications is the Mazak VC-500A/5x AM Hot Wire Deposition, which is a 5-axis machine tool incorporated with a wire feedstock 4kW laser deposition system. Methodologies and applications will be outlined for machine health and process monitoring. Other areas covered include process benchmarking, secure networking options for the proposed IoT framework, and hybrid process improvement. Limitations of these methods and future work for new sensor devices and application areas is also discussed.

Thien, Austen↗

Frequency-domain computing using nonlinear acoustic-wave device on lithium niobate

Abstract Multiply-accumulation are crucial computing operations in signal processing, numerical simulations, and machine learning. In recent years, optical analog approaches have demonstrated higher computing performance and better power efficiency than their digital counterparts. However, analog computing chips usually need large areas and complex structures for parallel computing, as a single device element only executes one computing operation at a single time. Here, we demonstrate frequency-domain computing using the nonlinear acoustic-wave devices on lithium niobate, featuring a normalized external second-harmonic generation conversion efficiency of ~ 5.7 × 10-4 W-1. The second-order sum-frequency nonlinear process of lithium niobate enables multiplication of inputs encoded in the frequency domain. Compared to the analog schemes, our device features a notably simpler design, and nanofabrication requires only one lift-off. Using a single acoustic-wave device within an area of 0.03 mm2, we can simultaneously conduct over 130,000 multiply-accumulation operations. Our acoustic-wave device shows applications in real and complex vector convolutions and image processing. This demonstration sets the stage for experimental realizations into frequency-domain integrated nonlinear acoustic computing systems, potentially shaping future developments in acoustic neural networks and quantum computing.

chai, mingzhao (ORCID:0009000466226341)↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Cyber Protection of Grid-Connected Devices Through Embedded Online Security

Cybersecurity research regarding the electric power grid has primarily been focused on protecting the communication layer of grid-connected devices against cyber-attack threats. Although many developed methods have greatly reduced the effects of a cyber-attack on the vulnerabilities of grid-connected devices, discovering new vulnerabilities is inevitable and a constant threat. As a result, the overall reliability and security of network communications with regard to grid-connected devices is a concern. Here, this paper proposes a method that further secures a system by focusing on the control and hardware layer of grid-connected devices. The device’s controller firmware will be validated and authenticated using integrated device emulation resources prior to being activated to control the grid-connected device. This verification process is performed while the controller is online and actively controlling power flows related to the device. Therefore, an attack to the system through a malicious firmware patch would be detected by the online security and rejected while safely maintaining continuous and stable control of the device. This method integrates the concepts of firmware hot-patching, digital twins, and active monitoring into an overall cybersecurity protection system.

cybersecurity↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

A Radiation-Hard 8-Channel 15-Bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The custom design of a radiation-hardened, 8-channel, 40-MSPS, 15-bit resolution, 14.2-bit dynamic range, 11.4-ENOB ADC data acquisition ASIC fabricated in a commercial 65-nm triple-well CMOS technology is presented. The ADC is developed for and integrates seamlessly into the readout system for the ATLAS liquid argon (LAr) calorimeter in the high-luminosity large hadron collider (HLLHC) upgrade at CERN, which will require a total of 364 936 ADC channels. A three-stage MDAC+SAR pipelined ADC architecture was designed to meet the physics requirements and scientific goals of the ATLAS experiment. The ADC is a fully self-contained data acquisition system that includes foreground calibration, digital data processing, digital control, and supporting circuitry. The measured performance shows the ADC achieves a competitive dynamic range and SNDR, and it meets or exceeds the ATLAS analog requirements. Radiation tolerance and scalability design considerations were implemented at the device-, circuit-, and system-level. Radiation-hardening-by-design techniques used include redundancy for digital circuits, the use of MiM capacitors, and a hybrid RC-DAC for the ADC core. The ADC ASIC was demonstrated to be robust against the effects of the intense radiation expected in the HL-LHC experimental environment.

DAQ↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Large dynamic range digital delay with sub-picosecond precision

Abstract We report on the development and performance of a digitally controlled phase delay with a step of 280 femtoseconds and a dynamic range of 230 picoseconds. Details of the device design and the simulations as well as comparisons with laboratory measurements will be discussed. We describe how we have used this ASIC to stabilize a digital clock to a precision of less than one picosecond.

Instruments & Instrumentation↗

A Novel Laser 3D Printing Method for the Advanced Manufacturing of Protonic Ceramics

Protonic ceramics (PCs) with high proton conductivity at intermediate temperatures (300–600 °C) have attracted many applications in energy conversion and storage devices such as PC fuel/electrolysis cells, PC membrane reactors, hydrogen pump, hydrogen or water-permeable membranes, and gas sensors. One of the essential steps for fulfilling the practical utilization of these intermediate-temperature PC energy devices is the successful development of advanced manufacturing methods for cost-effectively and rapidly fabricating them with high energy density and efficiency in a customized demand. In this work, we developed a new laser 3D printing (L3DP) technique by integrating digital microextrusion-based 3D printing and precise and rapid laser processing (sintering, drying, cutting, and polishing), which showed the capability of manufacturing PCs with desired complex geometries, crystal structures, and microstructures. The L3DP method allowed the fabrication of PC parts such as pellets, cylinders, cones, films, straight/lobed tubes with sealed endings, microchannel membranes, and half cells for assembling PC energy devices. The preliminary measurement of the L3DP electrolyte film showed a high proton conductivity of ≈7 × 10−3 S/cm. This L3DP technique not only demonstrated the potential to bring the PCs into practical use but also made it possible for the rapid direct digital manufacturing of ceramic-based devices.

08 HYDROGEN↗

3D Printing of Functional Hydrogel Devices for Screenings of Membrane Permeability and Selectivity

Developing a fundamental understanding of the effects of varying ligand chemistries on mass transport rates is key to designing membranes with solute-specific selectivity. While permeation cells offer a robust method to characterize membrane performance, they are limited to assessing a single membrane chemistry or salt solution per test. As a result, investigating the effects of varying ligand chemistries on membrane performance can be a tedious process, involving both the preparation of multiple samples and numerous, time-consuming permeation tests. This study uses digital light processing (DLP) 3D printing to fabricate a millifluidic flow-based permeation device made from a hydrogel active ester network that can be easily functionalized with ion-selective ligands. Without the need for bonding or assembly steps, ligands can be introduced and tested in the permeation device by simply injecting a small volume of a ligand solution. Various salt concentrations and molecular species can be cycled through a single device by switching the solution feeding into the salt reservoir, thereby reducing the number of samples needed for permeability and selectivity screenings. This research sets the groundwork for formulation development and postprocessing methods to 3D-print functional millifluidic devices capable of assessing solute selectivity in membranes and polymer adsorbents for aqueous separations. In this work, comparable salt permeability trends were observed with both 3D-printed devices and traditional assays. Devices were functionalized with an imidazole ligand to investigate salt permeability and selectivity of monovalent and divalent salts. Measurements showed increasing permeability for monovalent salts (NaCl) relative to divalent salts (MgCl 2 , CuCl 2 ) in functionalized membranes, with higher monovalent/divalent selectivity at increasing imidazole grafting densities. Here, the methods and findings described here represent a step toward developing higher-throughput methods with 3D-printed devices for screening the effects of ligand chemistry on mass transport rates in membrane materials.

36 MATERIALS SCIENCE↗

Single-shot complete spatiotemporal measurement of terawatt laser pulses

In this work, we demonstrate, for the first time, a single-shot, complete spatiotemporal measurement of pulses from a terawatt-scale, multi-stage-amplified, low repetition-rate laser source. The ultrashort pulse electric field, E(x,y,z,t), is spatiotemporally complex due to distortions that accrue from multiple chirped-pulse amplifiers, which requires a complete characterization. Meanwhile, the instability of the laser source introduces field profiles that vary significantly from pulse to pulse, which, together with the low repetition-rate (15 shots/hour), requires the use of a single-shot measurement technique. To accomplish the measurements, we used a wavelength-multiplexed, digital-holographic technique called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, specially tailored to measure picosecond pulses at a wavelength of about 1 μm. Specifically, individual pulses from the compact multipulse terawatt laser were measured, with up to 0.3 J per shot of energy and ~2 ps pulse durations, at 1052 nm. With these measurements, we characterized several major spatiotemporal distortions that affect the peak intensity at the laser focus, as well as the pulse-shape instability on a shot-to-shot basis. Our technique allows detailed diagnosis of laser pulses (especially high-order spatiotemporal distortions) and provides straightforward four-dimensional animations of pulse propagation to a focus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Negative string tension of a higher-charge Schwinger model via digital quantum simulation

We study some properties of generalized global symmetry for the charge- q Schwinger model in the Hamiltonian formalism, which is the (1 + 1)D quantum electrodynamics with a charge- q Dirac fermion. This model has the |$\mathbb {Z}_q\, 1$| -form symmetry, which is a remnant of the electric |$U(1)\, 1$| -form symmetry in the pure Maxwell theory. It is known that, if we put the theory on closed space, then the Hilbert space is decomposed into q distinct sectors, called universes, and some states with higher energy density do not decay to the ground state due to the selection rule of the 1-form symmetry. Even with open boundaries, we can observe the stability of such states by seeing a negative string tension behavior, meaning that opposite charges repel each other. In order to see negative string tensions, the vacuum angle θ has to be large enough and the standard path-integral Monte Carlo method suffers from the sign problem. We develop a method based on the adiabatic state preparation to see this feature with digital quantum simulation and confirm it using a classical simulator of quantum devices. In particular, we measure the local energy density and see how it jumps between the inside and outside of the insertion of the probe charges. We explicitly see that the energy density inside is lower than that outside. This is a clear signature of the negative string tension.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Testing of Instrumentation and Control Sensors and Cables for Small Modular Reactors

As advanced reactor concepts like small modular reactors (SMRs) progress towards design maturity and commercial deployment, it is important to assess their instrumentation and control (I&C) system sensors and cables to assure their safe, reliable, and efficient operation throughout their service lifetimes. The I&C system of any nuclear power plant (NPP) is the central nervous system of the plant and is made up of field devices such as sensors which are connected via cables to analog and/or digital systems. These systems are responsible for control and/or protection of the plant. The performance of I&C sensors and cables is dependent on several factors, including plant operating conditions. In particular, the plant operation can affect the static (accuracy) and dynamic (response) performance of the sensor, whereas the surrounding ambient environment can impact the remaining useful life of the cables, connectors, and other associated components within I&C sensor circuits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗